{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T14:53:05Z","timestamp":1762008785724,"version":"build-2065373602"},"reference-count":28,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2019,4,1]],"date-time":"2019-04-01T00:00:00Z","timestamp":1554076800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,4,1]],"date-time":"2019-04-01T00:00:00Z","timestamp":1554076800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2018,11,29]],"date-time":"2018-11-29T00:00:00Z","timestamp":1543449600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology"],"published-print":{"date-parts":[[2019,4]]},"DOI":"10.1016\/j.asmart.2018.11.006","type":"journal-article","created":{"date-parts":[[2018,12,14]],"date-time":"2018-12-14T13:39:48Z","timestamp":1544794788000},"page":"30-35","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":5,"special_numbering":"C","title":["Subacromial bone erosion due to suture-knots in arthroscopic rotator cuff repair: A report of two cases"],"prefix":"10.1016","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8924-4527","authenticated-orcid":false,"given":"Akihiro","family":"Uchida","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7306-5479","authenticated-orcid":false,"given":"Teruhisa","family":"Mihata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masashi","family":"Neo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.asmart.2018.11.006_bib1","doi-asserted-by":"crossref","first-page":"2091","DOI":"10.1177\/0363546511415660","article-title":"Functional and structural outcomes of single-row versus double-row versus combined double-row and suture-bridge repair for rotator cuff tears","volume":"39","author":"Mihata","year":"2011","journal-title":"Am J Sports Med"},{"key":"10.1016\/j.asmart.2018.11.006_bib2","first-page":"43","article-title":"Functional and anatomical results after rotator cuff repair","author":"Gazielly","year":"1994","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.asmart.2018.11.006_bib3","doi-asserted-by":"crossref","first-page":"953","DOI":"10.2106\/JBJS.F.00512","article-title":"Repair integrity and functional outcome after arthroscopic double-row rotator cuff repair. A prospective outcome study","volume":"89","author":"Sugaya","year":"2007","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.asmart.2018.11.006_bib4","doi-asserted-by":"crossref","first-page":"627","DOI":"10.2106\/JBJS.L.00255","article-title":"Clinical and radiographic outcomes of failed repairs of large or massive rotator cuff tears: minimum ten-year follow-up","volume":"95","author":"Paxton","year":"2013","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.asmart.2018.11.006_bib5","doi-asserted-by":"crossref","first-page":"989","DOI":"10.1007\/s00264-015-3012-3","article-title":"Primary stability of rotator cuff repair: can more suture materials yield more strength?","volume":"40","author":"Gulecyuz","year":"2016","journal-title":"Int Orthop"},{"key":"10.1016\/j.asmart.2018.11.006_bib6","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1007\/s00776-013-0504-0","article-title":"Biomechanical characteristics of the horizontal mattress stitch: implication for double-row and suture-bridge rotator cuff repair","volume":"19","author":"Tamboli","year":"2014","journal-title":"J\u00a0Orthop Sci"},{"key":"10.1016\/j.asmart.2018.11.006_bib7","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1177\/0363546505281238","article-title":"Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair","volume":"34","author":"Kim","year":"2006","journal-title":"Am J Sports Med"},{"key":"10.1016\/j.asmart.2018.11.006_bib8","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1177\/0363546510388152","article-title":"Effect of shoulder abduction angle on biomechanical properties of the repaired rotator cuff tendons with 3 types of double-row technique","volume":"39","author":"Mihata","year":"2011","journal-title":"Am J Sports Med"},{"key":"10.1016\/j.asmart.2018.11.006_bib9","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1016\/j.jse.2013.09.025","article-title":"Role of the superior shoulder capsule in passive stability of the glenohumeral joint","volume":"23","author":"Ishihara","year":"2014","journal-title":"J\u00a0Shoulder Elbow Surg"},{"key":"10.1016\/j.asmart.2018.11.006_bib10","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1177\/0363546513505425","article-title":"Arthroscopic repair of large U-shaped rotator cuff tears without margin convergence versus repair of crescent- or L-shaped tears","volume":"42","author":"Park","year":"2014","journal-title":"Am J Sports Med"},{"key":"10.1016\/j.asmart.2018.11.006_bib11","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1016\/j.arthro.2012.09.008","article-title":"Clinical and ultrasonographic outcomes of arthroscopic suture bridge repair for massive rotator cuff tear","volume":"29","author":"Park","year":"2013","journal-title":"Arthroscopy"},{"key":"10.1016\/j.asmart.2018.11.006_bib12","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1016\/j.jse.2006.09.010","article-title":"Part I: footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique","volume":"16","author":"Park","year":"2007","journal-title":"J\u00a0Shoulder Elbow Surg"},{"key":"10.1016\/j.asmart.2018.11.006_bib13","doi-asserted-by":"crossref","DOI":"10.1016\/j.arthro.2006.07.017","article-title":"Transosseous-equivalent\" rotator cuff repair technique","volume":"22","author":"Park","year":"2006","journal-title":"Arthroscopy"},{"key":"10.1016\/j.asmart.2018.11.006_bib14","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1016\/j.jse.2006.09.011","article-title":"Part II: biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique","volume":"16","author":"Park","year":"2007","journal-title":"J\u00a0Shoulder Elbow Surg"},{"key":"10.1016\/j.asmart.2018.11.006_bib15","doi-asserted-by":"crossref","first-page":"1249","DOI":"10.2106\/JBJS.K.00999","article-title":"A\u00a0multicenter randomized controlled trial comparing single-row with double-row fixation in arthroscopic rotator cuff repair","volume":"94","author":"Lapner","year":"2012","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.asmart.2018.11.006_bib16","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.arthro.2011.07.003","article-title":"Clinical outcome and imaging of arthroscopic single-row and double-row rotator cuff repair: a prospective randomized trial","volume":"28","author":"Ma","year":"2012","journal-title":"Arthroscopy"},{"key":"10.1016\/j.asmart.2018.11.006_bib17","doi-asserted-by":"crossref","first-page":"1544","DOI":"10.1016\/j.jse.2015.03.015","article-title":"Functional and structural comparisons of the arthroscopic knotless double-row suture bridge and single-row repair for anterosuperior rotator cuff tears","volume":"24","author":"Ide","year":"2015","journal-title":"J\u00a0Shoulder Elbow Surg"},{"key":"10.1016\/j.asmart.2018.11.006_bib18","doi-asserted-by":"crossref","first-page":"2440","DOI":"10.1177\/0363546512459170","article-title":"Arthroscopic rotator cuff repair using modified Mason-Allen medial row stitch: knotless versus knot-tying suture bridge technique","volume":"40","author":"Rhee","year":"2012","journal-title":"Am J Sports Med"},{"key":"10.1016\/j.asmart.2018.11.006_bib19","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.arthro.2015.07.004","article-title":"Footprint contact area and interface pressure comparison between the knotless and knot-tying transosseous-equivalent technique for rotator cuff repair","volume":"32","author":"Kim","year":"2016","journal-title":"Arthroscopy"},{"key":"10.1016\/j.asmart.2018.11.006_bib20","doi-asserted-by":"crossref","first-page":"e48","DOI":"10.2106\/JBJS.K.00158","article-title":"Repair integrity and functional outcomes after arthroscopic suture-bridge rotator cuff repair","volume":"94","author":"Kim","year":"2012","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.asmart.2018.11.006_bib21","doi-asserted-by":"crossref","first-page":"1482","DOI":"10.2106\/JBJS.L.01193","article-title":"Arthroscopic repair of massive contracted rotator cuff tears: aggressive release with anterior and posterior interval slides do not improve cuff healing and integrity","volume":"95","author":"Kim","year":"2013","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.asmart.2018.11.006_bib22","doi-asserted-by":"crossref","first-page":"1251","DOI":"10.1016\/j.arthro.2008.07.009","article-title":"Deformities associated with the suture-bridge technique for full-thickness rotator cuff tears","volume":"24","author":"Kim","year":"2008","journal-title":"Arthroscopy"},{"key":"10.1016\/j.asmart.2018.11.006_bib23","doi-asserted-by":"crossref","first-page":"562 e561","DOI":"10.1016\/j.arthro.2007.03.009","article-title":"A\u00a0modified suture-bridge technique for a marginal dog-ear deformity caused during rotator cuff repair","volume":"23","author":"Kim","year":"2007","journal-title":"Arthroscopy"},{"key":"10.1016\/j.asmart.2018.11.006_bib24","doi-asserted-by":"crossref","first-page":"1055","DOI":"10.1016\/j.arthro.2014.04.091","article-title":"Knot impingement after rotator cuff repair: is it real?","volume":"30","author":"Park","year":"2014","journal-title":"Arthroscopy"},{"key":"10.1016\/j.asmart.2018.11.006_bib25","doi-asserted-by":"crossref","first-page":"e17","DOI":"10.1016\/j.jse.2010.07.002","article-title":"Osteolysis of the inferior surface of the acromion caused by knots of the suture thread after rotator cuff repair surgery: knot impingement after rotator cuff repair","volume":"19","author":"Hotta","year":"2010","journal-title":"J\u00a0Shoulder Elbow Surg"},{"key":"10.1016\/j.asmart.2018.11.006_bib26","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1097\/01.phm.0000179518.85484.53","article-title":"Shoulder impingement syndrome: relationships between clinical, functional, and radiologic findings","volume":"85","author":"Ardic","year":"2006","journal-title":"Am J Phys Med Rehabil"},{"key":"10.1016\/j.asmart.2018.11.006_bib27","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/j.arthro.2006.12.012","article-title":"Arthroscopic repair of massive rotator cuff tears with stage 3 and 4 fatty degeneration","volume":"23","author":"Burkhart","year":"2007","journal-title":"Arthroscopy"},{"key":"10.1016\/j.asmart.2018.11.006_bib28","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1016\/j.arthro.2012.10.022","article-title":"Clinical results of arthroscopic superior capsule reconstruction for irreparable rotator cuff tears","volume":"29","author":"Mihata","year":"2013","journal-title":"Arthroscopy"}],"container-title":["Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2214687318301742?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2214687318301742?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T14:49:45Z","timestamp":1762008585000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2214687318301742"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,4]]},"references-count":28,"alternative-id":["S2214687318301742"],"URL":"https:\/\/doi.org\/10.1016\/j.asmart.2018.11.006","relation":{},"ISSN":["2214-6873"],"issn-type":[{"type":"print","value":"2214-6873"}],"subject":[],"published":{"date-parts":[[2019,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Subacromial bone erosion due to suture-knots in arthroscopic rotator cuff repair: A report of two cases","name":"articletitle","label":"Article Title"},{"value":"Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.asmart.2018.11.006","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Asia Pacific Knee, Arthroscopy and Sports Medicine Society. Published by Elsevier (Singapore) Pte Ltd.","name":"copyright","label":"Copyright"}]}}