{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T10:29:22Z","timestamp":1773570562004,"version":"3.50.1"},"reference-count":28,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2020,10,15]],"date-time":"2020-10-15T00:00:00Z","timestamp":1602720000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2020,10,15]],"date-time":"2020-10-15T00:00:00Z","timestamp":1602720000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2020,10,15]],"date-time":"2020-10-15T00:00:00Z","timestamp":1602720000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,10,15]],"date-time":"2020-10-15T00:00:00Z","timestamp":1602720000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2020,8,3]],"date-time":"2020-08-03T00:00:00Z","timestamp":1596412800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["arthroscopysportsmedicineandrehabilitation.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy, Sports Medicine, and Rehabil."],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To compare the biomechanical properties of high\u2010tensile strength tape and a high\u2010tensile strength suture in subpectoral biceps tenodesis using a suture anchor in a porcine tendon model.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A total of 24 artificial composite (polymer and glass fiber) humeri and porcine flexor profundus tendons were used. Two types of suture materials, high\u2010tensile strength sutures (group S) and high\u2010tensile strength tapes (group T), were evaluated. After we inserted metallic suture anchors with either 2 sutures or tapes 5 cm from the superomedial corner of the greater tuberosity, a Krackow suture technique was used to secure the tendons. After a preload of 5 N for 2 minutes, a cyclic loading test from 5 to 70 N was conducted for 500 cycles. Finally, the specimen was loaded to failure at a rate of 1 mm\/s.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      There were no significant between\u2010group differences in elongation after cyclic loading and elongation at failure load for group S and group T (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0= .977 and .630, respectively). The ultimate failure loads in group T (278.2 \u00b1 54 N) were significantly greater than those in group S (249.4 \u00b1 32 N) (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0= .028). In contrast, the stiffness values in group T (28.5 \u00b1 4.0 N\/mm) were significantly lower than those in group S (32.3 \u00b1 4.5 N) (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0= .028). Ten specimens in group S and 8 specimens in group T failed, with tendons being cut through by the sutures, whereas the other 2 specimens in group S and 4 specimens in group T failed due to suture breakage.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Using high\u2010tensile strength tapes in subpectoral biceps tenodesis using a suture anchor leads to significantly greater ultimate failure load as compared with using high\u2010tensile strength sutures in a porcine model. Although lower levels of stiffness were found in high\u2010tensile strength tape group, the difference in the means were not large between 2 groups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Relevance<\/jats:title>\n                    <jats:p>A strong suture\u2013tendon structure may prevent clinical failure of a subpectoral biceps tenodesis using a suture anchor.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.asmr.2020.07.018","type":"journal-article","created":{"date-parts":[[2020,10,15]],"date-time":"2020-10-15T03:58:14Z","timestamp":1602734294000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["High\u2010Tensile Strength Tapes Show Greater Ultimate Failure Load and Less Stiffness Than High\u2010Tensile Strength Sutures in a Subpectoral Biceps Tenodesis Porcine Model"],"prefix":"10.1002","volume":"2","author":[{"given":"Chih\u2010Kai","family":"Hong","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery National Cheng Kung University Hospital College of Medicine National Cheng Kung University Tainan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei\u2010Ren","family":"Su","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery National Cheng Kung University Hospital College of Medicine National Cheng Kung University Tainan"},{"name":"Skeleton Materials and Bio\u2010compatibility Core Lab Research Center of Clinical Medicine National Cheng Kung University Hospital College of Medicine National Cheng Kung University Tainan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fa\u2010Chuan","family":"Kuan","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery National Cheng Kung University Hospital College of Medicine National Cheng Kung University Tainan"},{"name":"Department of Biomedical Engineering National Cheng Kung University Tainan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yueh","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Sin Lau Hospital Tainan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chen\u2010Hao","family":"Chiang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Chiayi Christian Hospital Chiayi Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kai\u2010Lan","family":"Hsu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery National Cheng Kung University Hospital College of Medicine National Cheng Kung University Tainan"},{"name":"Department of Biomedical Engineering National Cheng Kung University Tainan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2020,10,15]]},"reference":[{"key":"e_1_2_3_2_2","doi-asserted-by":"publisher","DOI":"10.5435\/00124635-201011000-00002"},{"key":"e_1_2_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2013.11.013"},{"key":"e_1_2_3_4_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-014-3383-9"},{"key":"e_1_2_3_5_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-012-1918-5"},{"key":"e_1_2_3_6_2","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-019-1096-y"},{"key":"e_1_2_3_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-013-2587-8"},{"key":"e_1_2_3_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/os.12536"},{"key":"e_1_2_3_9_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546514560155"},{"key":"e_1_2_3_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11420-017-9575-3"},{"key":"e_1_2_3_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2017.06.019"},{"key":"e_1_2_3_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2015.07.009"},{"key":"e_1_2_3_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2010.01.024"},{"key":"e_1_2_3_14_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546516667577"},{"key":"e_1_2_3_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.01.026"},{"key":"e_1_2_3_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2016.05.019"},{"key":"e_1_2_3_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.11.097"},{"key":"e_1_2_3_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2014.11.043"},{"key":"e_1_2_3_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.03.053"},{"key":"e_1_2_3_20_2","doi-asserted-by":"publisher","DOI":"10.5435\/00124635-201402000-00006"},{"key":"e_1_2_3_21_2","doi-asserted-by":"publisher","DOI":"10.1177\/0954411911423346"},{"key":"e_1_2_3_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2008.05.005"},{"key":"e_1_2_3_23_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-016-2529-2"},{"key":"e_1_2_3_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2017.03.024"},{"key":"e_1_2_3_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2016.01.016"},{"key":"e_1_2_3_26_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-018-2927-8"},{"key":"e_1_2_3_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2018.01.007"},{"key":"e_1_2_3_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2013.06.013"},{"key":"e_1_2_3_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2018.03.004"}],"container-title":["Arthroscopy, Sports Medicine, and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666061X20300997?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666061X20300997?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.asmr.2020.07.018","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.asmr.2020.07.018","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.asmr.2020.07.018","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T09:10:18Z","timestamp":1773565818000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.asmr.2020.07.018"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,15]]},"references-count":28,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["10.1016\/j.asmr.2020.07.018"],"URL":"https:\/\/doi.org\/10.1016\/j.asmr.2020.07.018","archive":["Portico"],"relation":{},"ISSN":["2666-061X","2666-061X"],"issn-type":[{"value":"2666-061X","type":"print"},{"value":"2666-061X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,10,15]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"High-Tensile Strength Tapes Show Greater Ultimate Failure Load and Less Stiffness Than High-Tensile Strength Sutures in a Subpectoral Biceps Tenodesis Porcine Model","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy, Sports Medicine, and Rehabilitation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.asmr.2020.07.018","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 The Authors. Published by Elsevier Inc. on behalf of the Arthroscopy Association of North America.","name":"copyright","label":"Copyright"}]}}