{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T03:33:57Z","timestamp":1790134437606,"version":"4.0.1"},"reference-count":21,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2022,10,18]],"date-time":"2022-10-18T00:00:00Z","timestamp":1666051200000},"content-version":"am","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2022,10,18]],"date-time":"2022-10-18T00:00:00Z","timestamp":1666051200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2022,10,18]],"date-time":"2022-10-18T00:00:00Z","timestamp":1666051200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2022,10,18]],"date-time":"2022-10-18T00:00:00Z","timestamp":1666051200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,10,18]],"date-time":"2022-10-18T00:00:00Z","timestamp":1666051200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2022,9,23]],"date-time":"2022-09-23T00:00:00Z","timestamp":1663891200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/100012416","name":"Inova Health System","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100012416","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000005","name":"U.S. Department of Defense","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000005","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100006229","name":"Oak Ridge Institute for Science and Education","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006229","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100006225","name":"Oak Ridge Associated Universities","doi-asserted-by":"publisher","award":["DE-20 SC0014664"],"award-info":[{"award-number":["DE-20 SC0014664"]}],"id":[{"id":"10.13039\/100006225","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100006229","name":"Oak Ridge Institute for Science and Education","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006229","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000005","name":"U.S. Department of Defense","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000005","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100007188","name":"Uniformed Services University of the Health Sciences","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007188","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100007307","name":"Arthrex","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007307","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000015","name":"U.S. Department of Energy","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000015","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["arthroscopysportsmedicineandrehabilitation.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy, Sports Medicine, and Rehabil."],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate the maximal load at failure, cyclic displacement, and stiffness of onlay subpectoral biceps tenodesis (BT) with an intramedullary unicortical metal button (MB) versus a unicortical all\u2010suture button (ASB).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Eighteen matched paired human cadaveric proximal humeri were randomly allocated for subpectoral BT with either ASB or MB using a high\u2010strength suture. Specimens were tested on a servohydraulic mechanical testing apparatus under cyclic load for 1,000 cycles and then loaded to failure. The clamp was then adjusted to isolate the suture\u2013anchor point interface and loaded to failure. Maximal load to failure, displacement, and stiffness were compared.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      There was no significant difference between groups in stiffness, displacement, or yield load. The maximal load to failure for the MB was greater than the ASB (347.6 \u00b1 74.1N vs 266.5 \u00b1 69.3N,\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0= .047). Eight specimens in each group failed by suture pull\u2010through on the tendon. When the suture\u2013anchor point interface was isolated, there was no significant difference in maximal load at failure (MB 586.5 \u00b1 215.8N vs ASB 579.6 \u00b1 255.9N,\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0=\u00a0.957).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>This study demonstrates that the MB and ASB have similar biomechanical performance when used in subpectoral BT. Although the MB showed statistically significant greater maximal load to failure, there was no difference between the MB and ASB when the suture\u2013tendon interface was eliminated. Suture pull\u2010through was the most common mode of failure for both implants, underscoring the importance of the suture\u2013tendon interface.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical\u00a0Relevance<\/jats:title>\n                    <jats:p>Fixation techniques for the treatment of long head of the biceps brachii tenodesis continue to evolve. The use of an all\u2010suture suspensory button has advantages, but it is important to understand if this implant is a biomechanically suitable alternative to a metal suspensory button.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.asmr.2022.09.004","type":"journal-article","created":{"date-parts":[[2022,10,18]],"date-time":"2022-10-18T03:35:13Z","timestamp":1666064113000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"title":["All\u2010Suture Suspensory Button Has Similar Biomechanical Performance to Metal Suspensory Button for Onlay Subpectoral Biceps Tenodesis"],"prefix":"10.1002","volume":"4","author":[{"given":"Donald F.","family":"Colantonio","sequence":"first","affiliation":[{"name":"Department of Orthopaedics Walter Reed National Military Medical Center Bethesda Maryland"},{"name":"Walter Reed National Military Medical Center Department of Surgery Uniformed Services University of the Health Sciences Bethesda Maryland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher J.","family":"Tucker","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics Walter Reed National Military Medical Center Bethesda Maryland"},{"name":"Walter Reed National Military Medical Center Department of Surgery Uniformed Services University of the Health Sciences Bethesda Maryland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timothy P.","family":"Murphy","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics Walter Reed National Military Medical Center Bethesda Maryland"},{"name":"Walter Reed National Military Medical Center Department of Surgery Uniformed Services University of the Health Sciences Bethesda Maryland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick K.","family":"Mescher","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics Walter Reed National Military Medical Center Bethesda Maryland"},{"name":"Walter Reed National Military Medical Center Department of Surgery Uniformed Services University of the Health Sciences Bethesda Maryland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony H.","family":"Le","sequence":"additional","affiliation":[{"name":"Department of Defense\u2013Veterans Affairs Extremity Trauma and Amputation Center of Excellence USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert M.","family":"Putko","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics Walter Reed National Military Medical Center Bethesda Maryland"},{"name":"Walter Reed National Military Medical Center Department of Surgery Uniformed Services University of the Health Sciences Bethesda Maryland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erik R.","family":"Holm","sequence":"additional","affiliation":[{"name":"Walter Reed National Military Medical Center Department of Surgery Uniformed Services University of the Health Sciences Bethesda Maryland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Weishar","sequence":"additional","affiliation":[{"name":"Walter Reed National Military Medical Center Department of Surgery Uniformed Services University of the Health Sciences Bethesda Maryland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tarun K.","family":"Vippa","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Inova Health System Fairfax Virginia USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Theodore N.","family":"Rudic","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Inova Health System Fairfax Virginia USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edward S.","family":"Chang","sequence":"additional","affiliation":[{"name":"Walter Reed National Military Medical Center Department of Surgery Uniformed Services University of the Health Sciences Bethesda Maryland"},{"name":"Department of Orthopaedic Surgery Inova Health System Fairfax Virginia USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2022,10,18]]},"reference":[{"key":"e_1_2_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2005.04.002"},{"key":"e_1_2_2_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/JSA.0b013e3181824edf"},{"key":"e_1_2_2_4_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546516667577"},{"issue":"10","key":"e_1_2_2_5_2","article-title":"Biomechanical comparison of subpectoral biceps tenodesis onlay techniques","volume":"7","author":"Lacheta L.","year":"2019","journal-title":"Orthop J Sports Med"},{"key":"e_1_2_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2011.02.020"},{"key":"e_1_2_2_7_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.17.00797"},{"key":"e_1_2_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.01.026"},{"key":"e_1_2_2_9_2","volume-title":"FiberTak\u00ae Button vs Proximal Tenodesis Button: A Performance Comparison. Data on file (APT\u201004066)","author":"Arthrex Research and Development","year":"2020"},{"key":"e_1_2_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2005.08.008"},{"key":"e_1_2_2_11_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546506294854"},{"key":"e_1_2_2_12_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546519860489"},{"key":"e_1_2_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2011.01.022"},{"key":"e_1_2_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2016.01.016"},{"key":"e_1_2_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2005.05.002"},{"key":"e_1_2_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2005.03.020"},{"key":"e_1_2_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2021.06.036"},{"key":"e_1_2_2_18_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-014-3348-z"},{"key":"e_1_2_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2014.11.043"},{"key":"e_1_2_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2013.12.036"},{"key":"e_1_2_2_21_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-013-2760-0"},{"key":"e_1_2_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jseint.2020.08.004"}],"container-title":["Arthroscopy, Sports Medicine, and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666061X2200150X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666061X2200150X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.asmr.2022.09.004","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.asmr.2022.09.004","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.asmr.2022.09.004","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.asmr.2022.09.004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T09:07:52Z","timestamp":1773565672000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.asmr.2022.09.004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,18]]},"references-count":21,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["10.1016\/j.asmr.2022.09.004"],"URL":"https:\/\/doi.org\/10.1016\/j.asmr.2022.09.004","archive":["Portico"],"relation":{},"ISSN":["2666-061X","2666-061X"],"issn-type":[{"value":"2666-061X","type":"print"},{"value":"2666-061X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,18]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"All-Suture Suspensory Button Has Similar Biomechanical Performance to Metal Suspensory Button for Onlay Subpectoral Biceps Tenodesis","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy, Sports Medicine, and Rehabilitation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.asmr.2022.09.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Published by Elsevier Inc. on behalf of the Arthroscopy Association of North America.","name":"copyright","label":"Copyright"}]}}