{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T15:37:36Z","timestamp":1790005056112,"version":"4.0.1"},"reference-count":19,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2023,2,4]],"date-time":"2023-02-04T00:00:00Z","timestamp":1675468800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2023,2,4]],"date-time":"2023-02-04T00:00:00Z","timestamp":1675468800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2023,2,4]],"date-time":"2023-02-04T00:00:00Z","timestamp":1675468800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,2,4]],"date-time":"2023-02-04T00:00:00Z","timestamp":1675468800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2022,11,22]],"date-time":"2022-11-22T00:00:00Z","timestamp":1669075200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["arthroscopysportsmedicineandrehabilitation.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy, Sports Medicine, and Rehabil."],"published-print":{"date-parts":[[2023,4]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate the clinical outcomes for arthroscopic treatment of acute posterior cruciate ligament (PCL) avulsion fractures with adjustable\u2010loop cortical button fixation device.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Patients with PCL tibial avulsion fractures treated with an adjustable\u2010loop cortical button fixation device between October 2019 and October 2020 were retrospectively identified. Patients with type 1 were treated using plaster fixation as a conservative treatment, whereas patients with type 2 and 3 with displacement were treated using an arthroscopic adjustable\u2010loop cortical button. Operating time, incision recovery, complications, and postoperative fracture healing time were monitored. All patient follow\u2010up was done at 12 months\u2019 postoperatively. Lysholm Knee Score and the International Knee Documentation Committee score were used to assess knee function.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>A total of 30 patients were included in the study (20 male\/10 female; mean age 45.5 years, range 35\u201068 years). The mean operative time was 67.5 minutes (range: 50\u201090 minutes). The postoperative incision healed at stage A without complications, such as medically induced vascular nerve injury, intra\u2010articular hematoma, or infection. All 30 patients were tracked postoperatively for 12 to 14 months, with a mean follow\u2010up period of 12.6 months. The Lysholm knee function score was 45.93 \u00b1 6.15 before surgery and 87.10 \u00b1 3.71 at 12 months after surgery, and the International Knee Documentation Committee score was 19.27 \u00b1 4.40 before surgery and 95.47 \u00b1 1.87 at 12 months after surgery, with a statistically significant difference.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The treatment of PCL avulsion fractures with arthroscopic adjustable\u2010loop cortical button fixation is easy to perform and shows good clinical results in our study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence<\/jats:title>\n                    <jats:p>IV, therapeutic case series.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.asmr.2022.11.012","type":"journal-article","created":{"date-parts":[[2023,2,4]],"date-time":"2023-02-04T00:43:18Z","timestamp":1675471398000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":10,"title":["Adjustable\u2010Loop Cortical Button Fixation Results in Good Clinical Outcomes for Acute Tibial Avulsion Fracture of the Posterior Cruciate Ligament"],"prefix":"10.1002","volume":"5","author":[{"given":"YiRan","family":"Zhu","sequence":"first","affiliation":[{"name":"Sir Run Run Hospital of Nanjing Medical University Nanjing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"TangBo","family":"Yuan","sequence":"additional","affiliation":[{"name":"Sir Run Run Hospital of Nanjing Medical University Nanjing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dawei","family":"Cai","sequence":"additional","affiliation":[{"name":"Sir Run Run Hospital of Nanjing Medical University Nanjing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiachun","family":"Tao","sequence":"additional","affiliation":[{"name":"Sir Run Run Hospital of Nanjing Medical University Nanjing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiachun","family":"Dong","sequence":"additional","affiliation":[{"name":"Sir Run Run Hospital of Nanjing Medical University Nanjing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bo","family":"Hu","sequence":"additional","affiliation":[{"name":"Sir Run Run Hospital of Nanjing Medical University Nanjing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jian","family":"Qin","sequence":"additional","affiliation":[{"name":"Sir Run Run Hospital of Nanjing Medical University Nanjing China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2023,2,4]]},"reference":[{"key":"e_1_2_2_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-011-1618-6"},{"key":"e_1_2_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amsu.2019.10.022"},{"key":"e_1_2_2_4_2","doi-asserted-by":"publisher","DOI":"10.5792\/ksrr.17.073"},{"key":"e_1_2_2_5_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546517701911"},{"key":"e_1_2_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2015.06.014"},{"key":"e_1_2_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2022.02.002"},{"key":"e_1_2_2_8_2","first-page":"101","article-title":"All\u2010suture anchors versus metal suture anchors in the arthroscopic treatment of traumatic anterior shoulder instability: A comparison of mid\u2010term outcomes","volume":"32","author":"Uluyard\u0131mc\u0131 E.","year":"2021","journal-title":"Joint Dis Relat Surg"},{"key":"e_1_2_2_9_2","doi-asserted-by":"publisher","DOI":"10.1155\/2021\/3626276"},{"key":"e_1_2_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2020.102798"},{"key":"e_1_2_2_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/os.13401"},{"key":"e_1_2_2_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-009-0937-3"},{"key":"e_1_2_2_13_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10140-013-1121-0"},{"key":"e_1_2_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2021.01.044"},{"key":"e_1_2_2_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199005000-00031"},{"key":"e_1_2_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2015.10.013"},{"key":"e_1_2_2_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-198812000-00029"},{"key":"e_1_2_2_18_2","first-page":"787","article-title":"The killer turn in the posterior cruciate ligament reconstruction: mechanism and improvement","volume":"34","author":"Lin Y.","year":"2020","journal-title":"Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi"},{"key":"e_1_2_2_19_2","first-page":"829","article-title":"Comparison of arthroscopic suture bridge technique and conventional double tunnel\u00a0suture technique in the treatment of avulsion\u00a0fracture of posterior cruciate ligament","volume":"35","author":"Shi Chunwu","year":"2021","journal-title":"Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi"},{"key":"e_1_2_2_20_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-013-1835-3"}],"container-title":["Arthroscopy, Sports Medicine, and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666061X22001845?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666061X22001845?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.asmr.2022.11.012","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.asmr.2022.11.012","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.asmr.2022.11.012","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T08:37:27Z","timestamp":1773563847000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.asmr.2022.11.012"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,4]]},"references-count":19,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2023,4]]}},"alternative-id":["10.1016\/j.asmr.2022.11.012"],"URL":"https:\/\/doi.org\/10.1016\/j.asmr.2022.11.012","archive":["Portico"],"relation":{},"ISSN":["2666-061X","2666-061X"],"issn-type":[{"value":"2666-061X","type":"print"},{"value":"2666-061X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,2,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Adjustable-Loop Cortical Button Fixation Results in Good Clinical Outcomes for Acute Tibial Avulsion Fracture of the Posterior Cruciate Ligament","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy, Sports Medicine, and Rehabilitation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.asmr.2022.11.012","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 Published by Elsevier Inc. on behalf of the Arthroscopy Association of North America.","name":"copyright","label":"Copyright"}]}}