{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T09:55:57Z","timestamp":1773568557377,"version":"3.50.1"},"reference-count":20,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2023,9,17]],"date-time":"2023-09-17T00:00:00Z","timestamp":1694908800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2023,9,17]],"date-time":"2023-09-17T00:00:00Z","timestamp":1694908800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2023,9,17]],"date-time":"2023-09-17T00:00:00Z","timestamp":1694908800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,9,17]],"date-time":"2023-09-17T00:00:00Z","timestamp":1694908800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,8,23]],"date-time":"2023-08-23T00:00:00Z","timestamp":1692748800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["arthroscopysportsmedicineandrehabilitation.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy, Sports Medicine, and Rehabil."],"published-print":{"date-parts":[[2023,10]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To report the clinical outcomes of quadriceps tendon repair using adjustable cortical fixation devices at a minimum 2\u2010year follow\u2010up.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A retrospective chart review identified patients who underwent quadriceps tendon repair using adjustable cortical fixation devices between January 2017 and March 2020. Patients with a partial tendon rupture were excluded. Demographic and injury\u2010specific variables were gathered preoperatively and postoperatively from the electronic medical record and patient\u2010reported outcomes (Lysholm Knee Questionnaire, Lower Extremity Functional Scale, and SF\u201012) were collected via telephone at a minimum of 2 years postoperatively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Fourteen quadriceps tendon repairs were included in a total of 13 patients. The average time to follow\u2010up was 3.5 \u00b1 1.2 years with a range of 1.9 to 5.7 years. The mean age of this cohort was 55.7 \u00b1 11.6 years, and the mean body mass index was 32.9 \u00b1 6.0. Ten injuries (71.4%) were sustained by mechanical fall, 2 patients (14.3%) suffered a direct blow to the knee, and 2 patients (14.3%) reported a noncontact injury mechanism. Thirteen quadriceps ruptures (13\/14, 92.9%) underwent surgery within 10 days of their injury. One knee (7.1%) had a postoperative extensor lag of 5\u00b0, whereas another knee (7.1%) required a reoperation for manipulation under anesthesia and arthroscopic lysis of adhesions at 3 months\u2019 postoperatively. None of the included patients (0.0%) developed a tendon re\u2010rupture, venous thromboembolism, delayed wound healing, surgical\u2010site infection, neuropraxia or nerve injury, hardware irritation, patella fracture, or heterotopic ossification.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>In this study, adjustable cortical fixation was a safe and effective surgical technique for quadriceps tendon repair, with adequate restoration of quadriceps function and a low rate of adverse events at 2 years postoperatively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence<\/jats:title>\n                    <jats:p>Level IV, therapeutic case series.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.asmr.2023.100796","type":"journal-article","created":{"date-parts":[[2023,9,17]],"date-time":"2023-09-17T11:37:18Z","timestamp":1694950638000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Adjustable Cortical Fixation Repair Is a Safe and Effective Technique for Quadriceps Tendon Rupture"],"prefix":"10.1002","volume":"5","author":[{"given":"Heath P.","family":"Gould","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery MedStar Orthopaedic Institute Baltimore Maryland U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Griffith G.","family":"Gosnell","sequence":"additional","affiliation":[{"name":"Georgetown University School of Medicine Washington DC U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joseph M.","family":"Bano","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Summa Health Akron City Hospital Akron Ohio U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"suffix":"IV","given":"William R.","family":"Rate","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Miami \/ Jackson Health System Miami Florida U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sean B.","family":"Sequeira","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery MedStar Orthopaedic Institute Baltimore Maryland U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"suffix":"Jr.","given":"Milford H.","family":"Marchant","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery MedStar Orthopaedic Institute Baltimore Maryland U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2023,9,17]]},"reference":[{"key":"e_1_2_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2012.08.044"},{"key":"e_1_2_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2020.10.020"},{"key":"e_1_2_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2017.10.013"},{"key":"e_1_2_2_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0000000000001720"},{"key":"e_1_2_2_6_2","doi-asserted-by":"publisher","DOI":"10.1177\/03635465990270030601"},{"key":"e_1_2_2_7_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546507308192"},{"key":"e_1_2_2_8_2","doi-asserted-by":"publisher","DOI":"10.3109\/17453678508994366"},{"key":"e_1_2_2_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-198612000-00018"},{"key":"e_1_2_2_10_2","first-page":"146","article-title":"Functional results after surgical repair of quadriceps tendon rupture","volume":"68","author":"De Baere T.","year":"2002","journal-title":"Acta Orthop Belg"},{"key":"e_1_2_2_11_2","doi-asserted-by":"publisher","DOI":"10.1177\/2325967120974393"},{"key":"e_1_2_2_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0000000000001559"},{"key":"e_1_2_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.01.051"},{"key":"e_1_2_2_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00590-017-2095-5"},{"issue":"22","key":"e_1_2_2_15_2","article-title":"Successful surgical repair of acute quadriceps tendon rupture utilizing cortical button fixation: A case report","volume":"23","author":"Bae A.S.","year":"2021","journal-title":"Am J Case Rep"},{"key":"e_1_2_2_16_2","first-page":"336","article-title":"Repair of acute patellar tendon rupture augmented with strong sutures","volume":"30","author":"Otsubo H.","year":"2017","journal-title":"J\u00a0Knee Surg"},{"key":"e_1_2_2_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-198509000-00007"},{"key":"e_1_2_2_18_2","first-page":"509","article-title":"Complete quadriceps tendon ruptures","volume":"19","author":"Rougraff B.T.","year":"1996","journal-title":"Orthopedics"},{"key":"e_1_2_2_19_2","volume-title":"StatPearls. Treasure Island (FL)","author":"Weir C.B.","year":"2023"},{"key":"e_1_2_2_20_2","first-page":"6","article-title":"Knee range of motion inversely correlated with body mass index and blood glucose in sedentary adults","volume":"7","author":"Fairservice A.","year":"2018","journal-title":"Int J Prev Treat"},{"key":"e_1_2_2_21_2","first-page":"168","article-title":"Relationship between knee symptoms and biological features in recreational runners","volume":"56","author":"Ribeiro P.P.A.","year":"2021","journal-title":"Rev Bras Ortop (Sao Paulo)"}],"container-title":["Arthroscopy, Sports Medicine, and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666061X23001475?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666061X23001475?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.asmr.2023.100796","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.asmr.2023.100796","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.asmr.2023.100796","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T08:51:56Z","timestamp":1773564716000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.asmr.2023.100796"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,17]]},"references-count":20,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2023,10]]}},"alternative-id":["10.1016\/j.asmr.2023.100796"],"URL":"https:\/\/doi.org\/10.1016\/j.asmr.2023.100796","archive":["Portico"],"relation":{},"ISSN":["2666-061X","2666-061X"],"issn-type":[{"value":"2666-061X","type":"print"},{"value":"2666-061X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,17]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Adjustable Cortical Fixation Repair Is a Safe and Effective Technique for Quadriceps Tendon Rupture","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy, Sports Medicine, and Rehabilitation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.asmr.2023.100796","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Authors. Published by Elsevier Inc. on behalf of the Arthroscopy Association of North America.","name":"copyright","label":"Copyright"}],"article-number":"100796"}}