{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T11:39:41Z","timestamp":1781350781387,"version":"3.54.1"},"reference-count":23,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2024,5,29]],"date-time":"2024-05-29T00:00:00Z","timestamp":1716940800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2024,5,29]],"date-time":"2024-05-29T00:00:00Z","timestamp":1716940800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2024,5,29]],"date-time":"2024-05-29T00:00:00Z","timestamp":1716940800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,5,29]],"date-time":"2024-05-29T00:00:00Z","timestamp":1716940800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,12,22]],"date-time":"2023-12-22T00:00:00Z","timestamp":1703203200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/100008426","name":"DePuy Mitek Inc","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008426","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["arthroscopysportsmedicineandrehabilitation.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy, Sports Medicine, and Rehabil."],"published-print":{"date-parts":[[2024,8]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To compare the biomechanical performance of a suture with proposed dynamic self\u2010tensioning properties with that of commonly used high\u2010tensile sutures by evaluating suture loop length changes, responses to cyclic loading, and failure testing with intermittent saline soaks.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Six knots each of 4 different sutures were studied: 3 high\u2010tensile sutures (ORTHOCORD, FiberWire, and ETHIBOND), and a dynamically self\u2010tensioning suture (DYNACORD). After we measured loop length, knots were soaked in 37\u00b0C saline for 24 hours. Loop lengths were remeasured and tensile testing was performed. Cyclic elongation, first\u2010cycle excursion, and elongation amplitude were recorded. Knots were then resoaked and retested. Finally, knots were pulled to failure, and peak load and stiffness were measured. Values were compared using nonparametric statistical tests.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      DYNACORD loop length decreased by 27% after the first soak (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0= .002), whereas the other sutures demonstrated no length change (\n                      <jats:italic>P<\/jats:italic>\n                      &gt; .05). Although DYNACORD loop length increased during cyclic load testing (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0= .009), it was still significantly reduced after the second saline soak compared with\u00a0its initial length (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0= .002), whereas all other suture loops had elongated. ETHIBOND (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0= .004) and ORTHOCORD (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0= .002) had significantly less cyclic elongation from cycle I to cycle II testing compared with the other sutures. ETHIBOND had the lowest peak load at failure (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0= .002). FiberWire had the greatest stiffness (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0= .006).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Compared with other suture types, the self\u2010tensioning suture showed dynamic properties, demonstrating a decrease in loop length when soaked in a saline bath. This length was maintained after a second soak despite increased loop length during interval cyclic loading.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Relevance<\/jats:title>\n                    <jats:p>Knot and loop security are of paramount importance to arthroscopic soft\u2010tissue procedures. The ability for a suture to self\u2010tension has implications for how it may interact with tissues in\u00a0vivo to increase construct stability after arthroscopic soft tissue repair procedures.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.asmr.2023.100872","type":"journal-article","created":{"date-parts":[[2024,5,29]],"date-time":"2024-05-29T05:10:18Z","timestamp":1716959418000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"title":["A Dynamic, Self\u2010Tensioning Suture Contracts in Saline to Counteract Changes in Loop Length From Cyclic Loading"],"prefix":"10.1002","volume":"6","author":[{"given":"Nabil","family":"Mehta","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery Rush University Medical Center Chicago Illinois U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth","family":"Shewman","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Rush University Medical Center Chicago Illinois U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sachin","family":"Allahabadi","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Rush University Medical Center Chicago Illinois U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stanley","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Rush University Medical Center Chicago Illinois U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Niraj V.","family":"Lawande","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Rush University Medical Center Chicago Illinois U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Burton","family":"Dunlap","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Rush University Medical Center Chicago Illinois U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jorge","family":"Chahla","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Rush University Medical Center Chicago Illinois U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory P.","family":"Nicholson","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Rush University Medical Center Chicago Illinois U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Grant E.","family":"Garrigues","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Rush University Medical Center Chicago Illinois U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2024,5,29]]},"reference":[{"key":"e_1_2_3_2_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546515594449"},{"key":"e_1_2_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.08.048"},{"key":"e_1_2_3_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2021.05.010"},{"key":"e_1_2_3_5_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546513499228"},{"key":"e_1_2_3_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2008.09.010"},{"key":"e_1_2_3_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2019.10.008"},{"key":"e_1_2_3_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(98)70110-0"},{"key":"e_1_2_3_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2018.05.043"},{"key":"e_1_2_3_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.asmr.2021.07.014"},{"key":"e_1_2_3_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2004.03.005"},{"key":"e_1_2_3_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2006.04.106"},{"key":"e_1_2_3_13_2","article-title":"DYNACORDTM suture: A summary of the in vivo preclinical evidence. Global Orthopaedic & MedTech Summit","author":"Spenciner D.B.","year":"2021","journal-title":"Virtual"},{"key":"e_1_2_3_14_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546508323745"},{"key":"e_1_2_3_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2004.12.010"},{"key":"e_1_2_3_16_2","doi-asserted-by":"publisher","DOI":"10.3758\/BF03193146"},{"key":"e_1_2_3_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.03.053"},{"key":"e_1_2_3_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.asmr.2021.01.029"},{"key":"e_1_2_3_19_2","first-page":"84","article-title":"Material properties of common suture materials in orthopaedic surgery","volume":"30","author":"Najibi S.","year":"2010","journal-title":"Iowa Orthop J"},{"key":"e_1_2_3_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2019.02.028"},{"key":"e_1_2_3_21_2","doi-asserted-by":"publisher","DOI":"10.4103\/0973-6042.140115"},{"key":"e_1_2_3_22_2","first-page":"162","article-title":"Evaluation of the effect of 4 types of knots on the mechanical properties of 4 types of suture material used in small animal practice","volume":"80","author":"Avoine X.","year":"2016","journal-title":"Can J Vet Res"},{"key":"e_1_2_3_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.joms.2016.02.004"},{"key":"e_1_2_3_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jsurg.2010.06.007"}],"container-title":["Arthroscopy, Sports Medicine, and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666061X23002237?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666061X23002237?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.asmr.2023.100872","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.asmr.2023.100872","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.asmr.2023.100872","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T09:24:56Z","timestamp":1773566696000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.asmr.2023.100872"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,29]]},"references-count":23,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024,8]]}},"alternative-id":["10.1016\/j.asmr.2023.100872"],"URL":"https:\/\/doi.org\/10.1016\/j.asmr.2023.100872","archive":["Portico"],"relation":{},"ISSN":["2666-061X","2666-061X"],"issn-type":[{"value":"2666-061X","type":"print"},{"value":"2666-061X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,29]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A Dynamic, Self-Tensioning Suture Contracts in Saline to Counteract Changes in Loop Length From Cyclic Loading","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy, Sports Medicine, and Rehabilitation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.asmr.2023.100872","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier Inc. on behalf of the Arthroscopy Association of North America.","name":"copyright","label":"Copyright"}],"article-number":"100872"}}