{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T10:58:23Z","timestamp":1773572303226,"version":"3.50.1"},"reference-count":21,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2024,12,16]],"date-time":"2024-12-16T00:00:00Z","timestamp":1734307200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2024,12,16]],"date-time":"2024-12-16T00:00:00Z","timestamp":1734307200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2024,12,16]],"date-time":"2024-12-16T00:00:00Z","timestamp":1734307200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,12,16]],"date-time":"2024-12-16T00:00:00Z","timestamp":1734307200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,12,10]],"date-time":"2024-12-10T00:00:00Z","timestamp":1733788800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["arthroscopysportsmedicineandrehabilitation.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy, Sports Medicine, and Rehabil."],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To compare the stiffness, laxity, and failure rate of ultra\u2010high molecular weight polyethylene (UHMWPE) suture to suture tape measuring 0.15\u00a0\u00d7 1 mm used in 2 vertical inside\u2010out suture points for the treatment of longitudinal meniscal lesions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Twenty\u2010eight porcine knees were selected for this controlled biomechanical evaluation in a laboratory setting. The knees were divided into 2 groups: group S (vertical inside\u2010out meniscal sutures using UHMWPE suture) and group T (vertical inside\u2010out meniscal sutures using UHMWPE tape). A 1.5\u2010cm longitudinal lesion was created in the lateral meniscus, followed by 2 vertical sutures on the femoral surface of the meniscus. Biomechanical analyses were performed using a testing machine, including cyclic loading tests and load\u2010to\u2010failure tests.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Stiffness at the 5th cycle was 21.1 \u00b1 1.8 N\/mm for group T and 19.2 \u00b1 2.0 N\/mm for group S (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0= .013). At the 30th cycle, stiffness was 26.1 \u00b1 2.5 N\/mm for group T and 23.1 \u00b1 2.4 N\/mm for group S (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0= .003). At ultimate load to failure, stiffness was 26.5 \u00b1 1.6 N\/mm for group CS and 25.0 \u00b1 1.6 N\/mm for group T (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0= .918). The results showed no significant difference in lesion widening after cyclic testing or in load\u2010to\u2010failure between the 2 groups.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Both the meniscal suture tape and the ultra\u2010high strength suture exhibit similar biomechanical behaviors under radial loads, making both viable options for meniscal repair. The suture tape demonstrated significantly greater stiffness during the test cycles, which can offer more stable initial fixation. However, the actual differences were small, which limits the clinical relevance of the findings.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Relevance<\/jats:title>\n                    <jats:p>The findings of this study provide evidence that, compared with UHMWPE suture, suture tape may offer superior initial stability, which is crucial for the healing process of meniscal tissue.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.asmr.2024.101071","type":"journal-article","created":{"date-parts":[[2024,12,16]],"date-time":"2024-12-16T03:17:03Z","timestamp":1734319023000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Ultra\u2010High Molecular Weight Polyethylene Suture and Tape Show Similar Biomechanical Properties in Inside\u2010Out Repair of Lateral Meniscus Tears in a Porcine Model"],"prefix":"10.1002","volume":"7","author":[{"given":"Jos\u00e9 Leonardo","family":"Rocha de Faria","sequence":"first","affiliation":[{"name":"Knee Surgery Center National Institute of Traumatology and Orthopedics (INTO) Rio de Janeiro RJ \u2013 Brazil"},{"name":"School of Medicine from University of S\u00e3o Paulo \u2013 USP Ribeir\u00e3o Preto SP \u2013 Brazil"},{"name":"Research Division \u2010 National Institute of Traumatology and Orthopedics (INTO) Rio de Janeiro RJ \u2013 Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Igor Farias","family":"de Ara\u00fajo","sequence":"additional","affiliation":[{"name":"Knee Surgery Center National Institute of Traumatology and Orthopedics (INTO) Rio de Janeiro RJ \u2013 Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arthur Paiva Grimaldi","family":"Santos","sequence":"additional","affiliation":[{"name":"Biomechanical Engineering Laboratory of Federal University of Santa Catarina SC \u2013 Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mariana","family":"Radulski","sequence":"additional","affiliation":[{"name":"Medical School of Federal University of Santa Catarina SC \u2013 Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Douglas Mello","family":"Pav\u00e3o","sequence":"additional","affiliation":[{"name":"Knee Surgery Center National Institute of Traumatology and Orthopedics (INTO) Rio de Janeiro RJ \u2013 Brazil"},{"name":"School of Medicine from University of S\u00e3o Paulo \u2013 USP Ribeir\u00e3o Preto SP \u2013 Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ari Digiacomo Ocampo","family":"More","sequence":"additional","affiliation":[{"name":"Biomechanical Engineering Laboratory of Federal University of Santa Catarina SC \u2013 Brazil"},{"name":"Medical School of Federal University of Santa Catarina SC \u2013 Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alan de Paula","family":"Mozella","sequence":"additional","affiliation":[{"name":"Knee Surgery Center National Institute of Traumatology and Orthopedics (INTO) Rio de Janeiro RJ \u2013 Brazil"},{"name":"School of Medicine from University of S\u00e3o Paulo \u2013 USP Ribeir\u00e3o Preto SP \u2013 Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Geraldo da Rocha","family":"Motta Filho","sequence":"additional","affiliation":[{"name":"Research Division \u2010 National Institute of Traumatology and Orthopedics (INTO) Rio de Janeiro RJ \u2013 Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jo\u00e3o Antonio Matheus","family":"Guimar\u00e3es","sequence":"additional","affiliation":[{"name":"Research Division \u2010 National Institute of Traumatology and Orthopedics (INTO) Rio de Janeiro RJ \u2013 Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rodrigo","family":"Salim","sequence":"additional","affiliation":[{"name":"School of Medicine from University of S\u00e3o Paulo \u2013 USP Ribeir\u00e3o Preto SP \u2013 Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlos Rodrigo de Mello","family":"Roesler","sequence":"additional","affiliation":[{"name":"Biomechanical Engineering Laboratory of Federal University of Santa Catarina SC \u2013 Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2024,12,16]]},"reference":[{"key":"e_1_2_3_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2006.01.005"},{"key":"e_1_2_3_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-197211000-00028"},{"key":"e_1_2_3_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2011.06.037"},{"key":"e_1_2_3_5_2","doi-asserted-by":"publisher","DOI":"10.1177\/036354658901700205"},{"key":"e_1_2_3_6_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100140515"},{"key":"e_1_2_3_7_2","first-page":"34","article-title":"Anisotropic viscoelastic shear properties of bovine meniscus","volume":"306","author":"Zhu W.","year":"1994","journal-title":"Clin Orthop"},{"key":"e_1_2_3_8_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.25021"},{"key":"e_1_2_3_9_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546517737991"},{"key":"e_1_2_3_10_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546513502464"},{"key":"e_1_2_3_11_2","doi-asserted-by":"publisher","DOI":"10.1186\/s43019-020-00053-4"},{"key":"e_1_2_3_12_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546515615565"},{"key":"e_1_2_3_13_2","doi-asserted-by":"publisher","DOI":"10.1177\/23259671231209951"},{"key":"e_1_2_3_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2010.04.075"},{"key":"e_1_2_3_15_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546508314793"},{"key":"e_1_2_3_16_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.D.02887"},{"key":"e_1_2_3_17_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200406000-00013"},{"key":"e_1_2_3_18_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40634-017-0075-7"},{"key":"e_1_2_3_19_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40634-017-0114-4"},{"key":"e_1_2_3_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2018.11.040"},{"key":"e_1_2_3_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.asmart.2020.01.001"},{"key":"e_1_2_3_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2019.02.007"}],"container-title":["Arthroscopy, Sports Medicine, and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666061X24002141?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666061X24002141?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.asmr.2024.101071","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.asmr.2024.101071","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.asmr.2024.101071","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T09:26:56Z","timestamp":1773566816000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.asmr.2024.101071"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,16]]},"references-count":21,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025,4]]}},"alternative-id":["10.1016\/j.asmr.2024.101071"],"URL":"https:\/\/doi.org\/10.1016\/j.asmr.2024.101071","archive":["Portico"],"relation":{},"ISSN":["2666-061X","2666-061X"],"issn-type":[{"value":"2666-061X","type":"print"},{"value":"2666-061X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,16]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Ultra-High Molecular Weight Polyethylene Suture and Tape Show Similar Biomechanical Properties in Inside-Out Repair of Lateral Meniscus Tears in a Porcine Model","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy, Sports Medicine, and Rehabilitation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.asmr.2024.101071","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier Inc. on behalf of the Arthroscopy Association of North America.","name":"copyright","label":"Copyright"}],"article-number":"101071"}}