{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T05:39:22Z","timestamp":1783489162065,"version":"3.55.0"},"reference-count":23,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2025,9,18]],"date-time":"2025-09-18T00:00:00Z","timestamp":1758153600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2025,9,18]],"date-time":"2025-09-18T00:00:00Z","timestamp":1758153600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2025,9,18]],"date-time":"2025-09-18T00:00:00Z","timestamp":1758153600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,9,18]],"date-time":"2025-09-18T00:00:00Z","timestamp":1758153600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,9,14]],"date-time":"2025-09-14T00:00:00Z","timestamp":1757808000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["arthroscopysportsmedicineandrehabilitation.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy, Sports Medicine, and Rehabil."],"published-print":{"date-parts":[[2025,12]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate short\u2010term patient\u2010reported outcomes (PROs), complications, and reoperations after all\u2010inside meniscus repair using an all\u2010suture implant.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A review of a prospectively maintained database was performed to identify patients who underwent all\u2010inside meniscus repair using a knotless, tensionable, all\u2010suture implant by the senior author between November 2019 and December 2023. PROs (including Knee Single Assessment Numerical Evaluation, pain visual analog scale, and Patient\u2010Reported Outcomes Measurement Information System scores, as well as Knee Injury and Osteoarthritis Outcome Score [KOOS] subscales), and charts were analyzed to monitor change over time. Mixed linear regression, analysis of variance, and estimated marginal means were used to determine factors associated with improved or worsening outcomes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Sixty\u2010three patients were deemed eligible for inclusion. The minimum length of follow\u2010up was 7.33 months (mean, 16.32 months; range, 7.33\u201043.82 months). All assessed PROs at 6 months postoperatively and final follow\u2010up were significantly improved compared with the preoperative values (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .001 for all measures). Significant improvements between scores at 6 months postoperatively and final follow\u2010up were also observed in the Patient\u2010Reported Outcomes Measurement Information System\u2013Physical Function score (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .001) and the KOOS Sports and Recreation (\n                      <jats:italic>P<\/jats:italic>\n                      = .02) and Quality of Life (\n                      <jats:italic>P<\/jats:italic>\n                      = .02) subscales. There were no complications related to the implant, with zero cases of hardware irritation or hardware removal. There were 4 retears, with 2 patients undergoing subsequent partial meniscectomy. Five patients, who had undergone concomitant procedures, experienced arthrofibrosis and underwent further surgical intervention.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Patients undergoing meniscus repair with knotless, tensionable, all\u2010suture implants showed significantly improved PROs at 6 months after surgery that were maintained through final follow\u2010up, with a 6.35% failure rate. There were zero cases of hardware\u2010related complications, suggesting that knotless, tensionable, all\u2010suture implants are safe and reliable for all\u2010inside meniscus tear repair.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence<\/jats:title>\n                    <jats:p>Level IV, retrospective therapeutic case series.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.asmr.2025.101265","type":"journal-article","created":{"date-parts":[[2025,9,23]],"date-time":"2025-09-23T09:16:44Z","timestamp":1758619004000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["All\u2010Suture, All\u2010Inside Meniscus Repair Is Safe and Provides Favorable Short\u2010Term Clinical Outcomes"],"prefix":"10.1002","volume":"7","author":[{"given":"Miranda G.","family":"Manfre","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery University of Colorado School of Medicine Aurora Colorado U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bryce","family":"Hall","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Colorado School of Medicine Aurora Colorado U.S.A."},{"name":"Department of Orthopaedic Surgery Rocky Vista University Colorado Englewood Colorado U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel J.","family":"Stokes","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Colorado School of Medicine Aurora Colorado U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"Jr.","given":"Charles P.","family":"Nolte","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Colorado School of Medicine Aurora Colorado U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carson L.","family":"Keeter","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Colorado School of Medicine Aurora Colorado U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicholas","family":"Bertha","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Colorado School of Medicine Aurora Colorado U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P. Austin","family":"Serbin","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Colorado School of Medicine Aurora Colorado U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rachel M.","family":"Frank","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Colorado School of Medicine Aurora Colorado U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,9,18]]},"reference":[{"key":"e_1_2_3_2_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00590-018-2317-5"},{"key":"e_1_2_3_3_1","volume-title":"StatPearls","author":"Raj M.A.","year":"2024"},{"key":"e_1_2_3_4_1","doi-asserted-by":"publisher","DOI":"10.2519\/jospt.2013.4295"},{"key":"e_1_2_3_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2013.07.006"},{"key":"e_1_2_3_6_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12178-022-09764-5"},{"key":"e_1_2_3_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2024.01.021"},{"key":"e_1_2_3_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2022.12.017"},{"key":"e_1_2_3_9_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12178-022-09766-3"},{"key":"e_1_2_3_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2020.12.005"},{"key":"e_1_2_3_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2016.03.006"},{"key":"e_1_2_3_12_1","doi-asserted-by":"publisher","DOI":"10.1177\/03635465221107086"},{"key":"e_1_2_3_13_1","doi-asserted-by":"publisher","DOI":"10.1177\/23259671241245127"},{"key":"e_1_2_3_14_1","doi-asserted-by":"publisher","DOI":"10.1002\/jeo2.12110"},{"key":"e_1_2_3_15_1","volume-title":"R: A language and environment for statistical computing. Version 4.3.2","author":"R Core Team","year":"2024"},{"key":"e_1_2_3_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2017.05.025"},{"key":"e_1_2_3_17_1","doi-asserted-by":"publisher","DOI":"10.1177\/03635465231158385"},{"key":"e_1_2_3_18_1","doi-asserted-by":"publisher","DOI":"10.1002\/ksa.12485"},{"key":"e_1_2_3_19_1","first-page":"e56413","article-title":"All\u2010inside arthroscopic meniscus repair for patients over 40 years of age: Is forty the new twenty?","volume":"16","author":"Ciapini G.","year":"2024","journal-title":"Cureus"},{"key":"e_1_2_3_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2023.103681"},{"key":"e_1_2_3_21_1","doi-asserted-by":"publisher","DOI":"10.1007\/s43465-024-01135-1"},{"key":"e_1_2_3_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2022.11.027"},{"key":"e_1_2_3_23_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-020-03464-w"},{"key":"e_1_2_3_24_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-019-05389-3"}],"container-title":["Arthroscopy, Sports Medicine, and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666061X25001919?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666061X25001919?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.asmr.2025.101265","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.asmr.2025.101265","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.asmr.2025.101265","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T12:05:36Z","timestamp":1778155536000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.asmr.2025.101265"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,18]]},"references-count":23,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025,12]]}},"alternative-id":["10.1016\/j.asmr.2025.101265"],"URL":"https:\/\/doi.org\/10.1016\/j.asmr.2025.101265","archive":["Portico"],"relation":{},"ISSN":["2666-061X","2666-061X"],"issn-type":[{"value":"2666-061X","type":"print"},{"value":"2666-061X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,18]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"All-Suture, All-Inside Meniscus Repair Is Safe and Provides Favorable Short-Term Clinical Outcomes","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy, Sports Medicine, and Rehabilitation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.asmr.2025.101265","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Authors. Published by Elsevier Inc. on behalf of the Arthroscopy Association of North America\u00e9","name":"copyright","label":"Copyright"}],"article-number":"101265"}}