{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T16:40:48Z","timestamp":1786984848669,"version":"build-2736575974"},"reference-count":25,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2006,4,1]],"date-time":"2006-04-01T00:00:00Z","timestamp":1143849600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2006,4,1]],"date-time":"2006-04-01T00:00:00Z","timestamp":1143849600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["annalsthoracicsurgery.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Annals of Thoracic Surgery"],"published-print":{"date-parts":[[2006,4]]},"DOI":"10.1016\/j.athoracsur.2005.09.045","type":"journal-article","created":{"date-parts":[[2006,3,25]],"date-time":"2006-03-25T07:16:45Z","timestamp":1143271005000},"page":"1291-1296","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":18,"title":["Hemolysis in Mechanical Bileaflet Prostheses: Experience With the Bicarbon Valve"],"prefix":"10.1016","volume":"81","author":[{"given":"Miguel","family":"Josa","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manuel","family":"Castell\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carles","family":"Par\u00e9","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9 L.","family":"Bedini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ram\u00f3n","family":"Carta\u00f1\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carles A.","family":"Mestres","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9 L.","family":"Pomar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaume","family":"Mulet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.athoracsur.2005.09.045_bib1","first-page":"376","article-title":"Prosthesis-induced hemolysis","volume":"7","author":"Ellis","year":"1998","journal-title":"J Heart Valve Dis"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib2","first-page":"312","article-title":"Leakage flow at mechanical heart valve prostheses","volume":"8","author":"Steegers","year":"1999","journal-title":"J Heart Valve Dis"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib3","doi-asserted-by":"crossref","first-page":"M600","DOI":"10.1097\/00002480-199207000-00107","article-title":"Pivot design in bileaflet valves","volume":"38","author":"Vallana","year":"1992","journal-title":"ASAIO Trans"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib4","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1177\/039139889401700506","article-title":"Relationship between some design characteristics and wear in the Bicarbon heart valve prosthesis","volume":"17","author":"Arru","year":"1994","journal-title":"Int J Artif Organs"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib5","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/S1010-7940(02)00658-9","article-title":"Sorin Bicarbon bileaflet valve","volume":"23","author":"Borman","year":"2003","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib6","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1016\/S0894-7317(97)70026-9","article-title":"Normal echocardiographic characteristics of the Sorin Bicarbon bileaflet prosthetic heart valve in the mitral and aortic positions","volume":"10","author":"Badano","year":"1997","journal-title":"J Am Soc Echocardiogr"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib7","first-page":"410","article-title":"The Bicarbon heart valve prosthesis","volume":"6","author":"Casselman","year":"1997","journal-title":"J Heart Valve Dis"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib8","doi-asserted-by":"crossref","first-page":"1069","DOI":"10.1016\/S0002-9149(99)00017-X","article-title":"Evaluation of the Sorin Bicarbon bileaflet valve in 488 patients (519 prostheses)","volume":"83","author":"Goldsmith","year":"1999","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib9","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1016\/S0003-4975(96)00531-0","article-title":"Guidelines for reporting morbidity and mortality after cardiac valvular operations","volume":"62","author":"Edmunds","year":"1996","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib10","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1016\/0002-9149(93)90516-F","article-title":"Frequency and severity of intravascular hemolysis after left sided cardiac valve replacement with Medtronic Hall and St. Jude Medical prostheses, and influence of prosthetic type, position, size and number","volume":"71","author":"Skoularigis","year":"1993","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib11","series-title":"Heart valve consultant","author":"Horstkotte","year":"1991"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib12","series-title":"Clinical chemistry. Principles and techniques","first-page":"815","article-title":"Enzymes","author":"Demetriou","year":"1974"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib13","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1016\/S0735-1097(86)80480-6","article-title":"Doppler echocardiographic evaluation of Hancock and Bjork-Shiley prosthetic valves","volume":"7","author":"Sagar","year":"1986","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib14","doi-asserted-by":"crossref","first-page":"810","DOI":"10.1161\/01.CIR.72.4.810","article-title":"Non-invasive estimation of valve area in patients with aortic stenosis by Doppler ultrasound and two-dimensional echocardiography","volume":"72","author":"Skajaerpe","year":"1985","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib15","doi-asserted-by":"crossref","first-page":"1459","DOI":"10.1016\/S0003-4975(00)01191-7","article-title":"Standard aortic St. Jude valve at 18 years","volume":"69","author":"Lund","year":"2000","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib16","first-page":"45","article-title":"An international experience with the CarboMedics prosthetic heart valve","volume":"4","author":"Copeland","year":"1995","journal-title":"J Heart Valve Dis"},{"issue":"Suppl 1","key":"10.1016\/j.athoracsur.2005.09.045_bib17","doi-asserted-by":"crossref","first-page":"S113","DOI":"10.1093\/ejcts\/6.Supplement_1.S113","article-title":"In vitro pulsatile hemodynamics of five mechanical aortic heart valve prostheses","volume":"69","author":"Walker","year":"1992","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib18","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/0002-9149(91)90104-S","article-title":"Blood rheology after cardiac valve replacement with mechanical prostheses or bioprostheses","volume":"67","author":"Koppensteiner","year":"1991","journal-title":"Am J Cardiol"},{"issue":"Suppl I","key":"10.1016\/j.athoracsur.2005.09.045_bib19","first-page":"S8","article-title":"An in-vitro investigation of prosthetic heart valve cavitation in blood","volume":"3","author":"Garrison","year":"1994","journal-title":"J Heart Valve Dis"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib20","first-page":"142","article-title":"Examination of hemolytic potential with the on-X prosthetic heart valve","volume":"9","author":"Birnbaum","year":"2000","journal-title":"J Heart Valve Dis"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib21","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/S0003-4975(10)65860-2","article-title":"Intractable hemolysis caused by perivalvular leakage following mitral valve replacement with the St. Jude Medical prosthesis","volume":"46","author":"Okita","year":"1988","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib22","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/1010-7940(94)90126-0","article-title":"The St. Jude Medical prosthesis in the mitral position","volume":"8","author":"Isomura","year":"1994","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib23","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1161\/01.CIR.85.1.323","article-title":"Color Doppler regurgitant characteristics of normal mechanical mitral valve prostheses in vitro","volume":"85","author":"Baumgatner","year":"1992","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib24","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1016\/S0167-5273(99)00024-8","article-title":"Intravascular hemolysis after mitral and aortic valve replacement with different types of mechanical prostheses","volume":"69","author":"Ismeno","year":"1999","journal-title":"Intern J Cardiol"},{"key":"10.1016\/j.athoracsur.2005.09.045_bib25","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1067\/mtc.2002.120337","article-title":"Intravascular hemolysis in patients with new-generation prosthetic heart valves","volume":"123","author":"Mecozzi","year":"2002","journal-title":"J Thorac Cardiovasc Surg"}],"container-title":["The Annals of Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003497505017583?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003497505017583?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,13]],"date-time":"2025-09-13T00:35:37Z","timestamp":1757723737000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0003497505017583"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,4]]},"references-count":25,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2006,4]]}},"alternative-id":["S0003497505017583"],"URL":"https:\/\/doi.org\/10.1016\/j.athoracsur.2005.09.045","relation":{},"ISSN":["0003-4975"],"issn-type":[{"value":"0003-4975","type":"print"}],"subject":[],"published":{"date-parts":[[2006,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Hemolysis in Mechanical Bileaflet Prostheses: Experience With the Bicarbon Valve","name":"articletitle","label":"Article Title"},{"value":"The Annals of Thoracic Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.athoracsur.2005.09.045","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2006 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}