{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T18:07:42Z","timestamp":1776449262569,"version":"3.51.2"},"reference-count":29,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2006,11,1]],"date-time":"2006-11-01T00:00:00Z","timestamp":1162339200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2006,11,1]],"date-time":"2006-11-01T00:00:00Z","timestamp":1162339200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["annalsthoracicsurgery.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Annals of Thoracic Surgery"],"published-print":{"date-parts":[[2006,11]]},"DOI":"10.1016\/j.athoracsur.2006.05.079","type":"journal-article","created":{"date-parts":[[2006,10,24]],"date-time":"2006-10-24T13:57:34Z","timestamp":1161698254000},"page":"1774-1778","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":28,"title":["Does Continuous Flow Left Ventricular Assist Device Technology Have a Positive Impact on Outcome Pretransplant and Posttransplant?"],"prefix":"10.1016","volume":"82","author":[{"given":"Stefan","family":"Klotz","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joerg","family":"Stypmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Henryk","family":"Welp","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christof","family":"Schmid","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gabriele","family":"Drees","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Rukosujew","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hans H.","family":"Scheld","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.athoracsur.2006.05.079_bib1","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1007\/s00059-002-2400-9","article-title":"[Heart assist systems--current status]","volume":"27","author":"Hetzer","year":"2002","journal-title":"Herz"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib2","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1016\/S0003-4975(99)00530-5","article-title":"A miniature implantable axial flow ventricular assist device","volume":"68","author":"DeBakey","year":"1999","journal-title":"Ann Thorac Surg"},{"issue":"suppl 1","key":"10.1016\/j.athoracsur.2006.05.079_bib3","first-page":"II272","article-title":"Worldwide experience with the MicroMed DeBakey ventricular assist device as a bridge to transplantation","volume":"108","author":"Goldstein","year":"2003","journal-title":"Circulation"},{"issue":"suppl 3","key":"10.1016\/j.athoracsur.2006.05.079_bib4","first-page":"III183","article-title":"Pulsatile flow in patients with a novel nonpulsatile implantable ventricular assist device","volume":"102","author":"Potapov","year":"2000","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib5","doi-asserted-by":"crossref","first-page":"1188","DOI":"10.1016\/j.healun.2004.08.024","article-title":"First clinical experience with the Incor left ventricular assist device","volume":"24","author":"Schmid","year":"2005","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib6","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1016\/S0003-4975(96)00437-7","article-title":"Improved left ventricular function after chronic left ventricular unloading","volume":"62","author":"Frazier","year":"1996","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib7","doi-asserted-by":"crossref","first-page":"742","DOI":"10.1016\/S0003-4975(99)00542-1","article-title":"Cardiac recovery in dilated cardiomyopathy by unloading with a left ventricular assist device","volume":"68","author":"Hetzer","year":"1999","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib8","doi-asserted-by":"crossref","first-page":"2717","DOI":"10.1161\/01.CIR.91.11.2717","article-title":"Reversal of chronic ventricular dilation in patients with end-stage cardiomyopathy by prolonged mechanical unloading","volume":"91","author":"Levin","year":"1995","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib9","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1161\/01.CIR.96.2.542","article-title":"Weaning from mechanical cardiac support in patients with idiopathic dilated cardiomyopathy","volume":"96","author":"Muller","year":"1997","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib10","doi-asserted-by":"crossref","first-page":"1178","DOI":"10.1161\/01.CIR.98.12.1178","article-title":"Comparison of exercise performance in patients with chronic severe heart failure versus left ventricular assist devices","volume":"98","author":"Mancini","year":"1998","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib11","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/S0003-4975(03)01336-5","article-title":"Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support","volume":"77","author":"Klotz","year":"2004","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib12","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1111\/j.1432-2277.2005.00234.x","article-title":"Waiting for a thoracic transplant in Eurotransplant","volume":"19","author":"Smits","year":"2006","journal-title":"Transpl Int"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib13","doi-asserted-by":"crossref","first-page":"1710","DOI":"10.1016\/j.healun.2005.03.019","article-title":"Revision of the 1990 working formulation for the standardization of nomenclature in the diagnosis of heart rejection","volume":"24","author":"Stewart","year":"2005","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib14","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1007\/s10047-005-0322-z","article-title":"Role of ventricular assist devices in the German heart allocation system","volume":"9","author":"Komoda","year":"2006","journal-title":"J Artif Organs"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib15","doi-asserted-by":"crossref","first-page":"2383","DOI":"10.1161\/01.CIR.98.22.2383","article-title":"Low incidence of myocardial recovery after left ventricular assist device implantation in patients with chronic heart failure","volume":"98","author":"Mancini","year":"1998","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib16","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.healun.2005.07.014","article-title":"Effect of mechanical circulatory support on outcomes after heart transplantation","volume":"25","author":"Drakos","year":"2006","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib17","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1046\/j.1525-1594.2000.06621.x","article-title":"Morbidity and outcome after mechanical ventricular support using Thoratec, Novacor, and HeartMate for bridging to heart transplantation","volume":"24","author":"Minami","year":"2000","journal-title":"Artif Organs"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib18","doi-asserted-by":"crossref","first-page":"1054","DOI":"10.1016\/S1053-2498(02)01179-8","article-title":"Outcome of patients surviving to heart transplantation after being mechanically bridged for more than 100 days","volume":"22","author":"Schmid","year":"2003","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib19","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1097\/00002480-200105000-00023","article-title":"Inflammatory response after implantation of a left ventricular assist device: comparison between the axial flow MicroMed DeBakey VAD and the pulsatile Novacor device","volume":"47","author":"Loebe","year":"2001","journal-title":"ASAIO J"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib20","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1016\/S1053-2498(01)00351-5","article-title":"Postoperative course of S-100B protein and neuron-specific enolase in patients after implantation of continuous and pulsatile flow LVADs","volume":"20","author":"Potapov","year":"2001","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib21","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1016\/j.healun.2004.02.017","article-title":"Cellular and hemodynamics responses of failing myocardium to continuous flow mechanical circulatory support using the DeBakey-Noon left ventricular assist device: a comparative analysis with pulsatile-type devices","volume":"24","author":"Thohan","year":"2005","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib22","doi-asserted-by":"crossref","first-page":"971","DOI":"10.1016\/j.ejcts.2004.01.052","article-title":"Implantable left ventricular assist device for treatment of pulmonary hypertension in candidates for orthotopic heart transplantation-a preliminary study","volume":"25","author":"Martin","year":"2004","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib23","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1016\/j.ejcts.2004.11.001","article-title":"Normalization of high pulmonary vascular resistance with LVAD support in heart transplantation candidates","volume":"27","author":"Salzberg","year":"2005","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib24","doi-asserted-by":"crossref","first-page":"2054","DOI":"10.1016\/j.healun.2005.06.028","article-title":"Impact of left ventricular assist device (LVAD)-mediated humoral sensitization on posttransplant outcomes","volume":"24","author":"Joyce","year":"2005","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib25","doi-asserted-by":"crossref","first-page":"1120","DOI":"10.1016\/S0003-4975(97)00807-2","article-title":"Factors influencing HLA sensitization in implantable LVAD recipients","volume":"64","author":"Massad","year":"1997","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib26","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1016\/j.healun.2003.12.008","article-title":"Relationship between bridging with ventricular assist device on rejection after heart transplantation","volume":"24","author":"Pamboukian","year":"2005","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib27","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1097\/00000658-200009000-00002","article-title":"Impact of current management practices on early and late death in more than 500 consecutive cardiac transplant recipients","volume":"232","author":"John","year":"2000","journal-title":"Ann Surg"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib28","doi-asserted-by":"crossref","first-page":"945","DOI":"10.1016\/j.athoracsur.2005.03.096","article-title":"Human leukocyte antigen sensitization in ventricular assist device recipients: a lesser risk with the DeBakey axial pump","volume":"80","author":"Grinda","year":"2005","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2006.05.079_bib29","first-page":"1024","article-title":"Emergency versus elective\/urgent left ventricular assist device implantation","volume":"17","author":"Schmid","year":"1998","journal-title":"J Heart Lung Transplant"}],"container-title":["The Annals of Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003497506010897?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003497506010897?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,13]],"date-time":"2025-09-13T00:39:37Z","timestamp":1757723977000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0003497506010897"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,11]]},"references-count":29,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2006,11]]}},"alternative-id":["S0003497506010897"],"URL":"https:\/\/doi.org\/10.1016\/j.athoracsur.2006.05.079","relation":{},"ISSN":["0003-4975"],"issn-type":[{"value":"0003-4975","type":"print"}],"subject":[],"published":{"date-parts":[[2006,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Does Continuous Flow Left Ventricular Assist Device Technology Have a Positive Impact on Outcome Pretransplant and Posttransplant?","name":"articletitle","label":"Article Title"},{"value":"The Annals of Thoracic Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.athoracsur.2006.05.079","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2006 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}