{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,16]],"date-time":"2025-09-16T18:17:51Z","timestamp":1758046671293,"version":"3.44.0"},"reference-count":18,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2008,12,1]],"date-time":"2008-12-01T00:00:00Z","timestamp":1228089600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2008,12,1]],"date-time":"2008-12-01T00:00:00Z","timestamp":1228089600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["annalsthoracicsurgery.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Annals of Thoracic Surgery"],"published-print":{"date-parts":[[2008,12]]},"DOI":"10.1016\/j.athoracsur.2008.08.019","type":"journal-article","created":{"date-parts":[[2008,11,26]],"date-time":"2008-11-26T09:14:18Z","timestamp":1227690858000},"page":"1799-1803","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"title":["Hemodynamic Evaluation and Midterm Outcome of Aortic Valve Replacement With Size 19 Perimount Prosthetic Valve"],"prefix":"10.1016","volume":"86","author":[{"given":"Pradeep","family":"Narayan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Barnaby C.","family":"Reeves","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Syad I.A.","family":"Rizvi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kayvan","family":"Shokrollahi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Huda","family":"Ismail","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gianni D.","family":"Angelini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Angus","family":"Nightingale","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Massimo","family":"Caputo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.athoracsur.2008.08.019_bib1","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1016\/j.athoracsur.2005.10.013","article-title":"Prevalence and avoidance of patient-prosthesis mismatch in aortic valve replacement in small adults","volume":"81","author":"Sakamoto","year":"2006","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2008.08.019_bib2","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1161\/01.CIR.0000085167.67105.32","article-title":"Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement","volume":"108","author":"Blais","year":"2003","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2008.08.019_bib3","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1136\/hrt.2005.067363","article-title":"Prosthesis-patient mismatch: definition, clinical impact and prevention","volume":"92","author":"Pibarot","year":"2006","journal-title":"Heart"},{"key":"10.1016\/j.athoracsur.2008.08.019_bib4","doi-asserted-by":"crossref","first-page":"1657","DOI":"10.1016\/S0003-4975(99)00717-1","article-title":"Patient prosthesis mismatch is negligible with modern small size aortic valve prosthesis","volume":"68","author":"Izzat","year":"1999","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2008.08.019_bib5","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1016\/S0022-5223(19)35899-4","article-title":"In vitro hemodynamic characteristics of tissue bioprostheses in the aortic position","volume":"92","author":"Yoganathan","year":"1986","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.athoracsur.2008.08.019_bib6","doi-asserted-by":"crossref","first-page":"1056","DOI":"10.1016\/j.jtcvs.2004.08.028","article-title":"Exercise hemodynamics of bovine versus porcine bioprostheses: a prospective randomized comparison of the mosaic and perimount aortic valves","volume":"129","author":"Eichinger","year":"2005","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.athoracsur.2008.08.019_bib7","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.athoracsur.2007.07.058","article-title":"Enlargement of the small aortic root during aortic valve replacement: is there a benefit?","volume":"85","author":"Kulik","year":"2008","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2008.08.019_bib8","series-title":"Cardiac surgery in the adult","first-page":"857","article-title":"Bioprosthetic aortic valve replacement: stented pericardial and porcine valves","author":"Desai","year":"2007"},{"key":"10.1016\/j.athoracsur.2008.08.019_bib9","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1016\/S1010-7940(02)00071-4","article-title":"Comparison of exercise and dobutamine echocardiography in the haemodynamic assessment of small size mechanical aortic valve prosthesis","volume":"21","author":"Kadir","year":"2002","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.athoracsur.2008.08.019_bib10","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1016\/S0003-4975(99)01389-2","article-title":"Regression of hypertrophy after Carpentier-Edwards pericardial aortic valve replacement","volume":"69","author":"Khan","year":"2000","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2008.08.019_bib11","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1016\/S0022-5223(19)38785-9","article-title":"In vivo hemodynamic comparison of porcine and pericardial valves","volume":"89","author":"Cosgrove","year":"1985","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"19 Suppl 3","key":"10.1016\/j.athoracsur.2008.08.019_bib12","first-page":"III5","article-title":"Prosthesis-patient mismatch affects survival after aortic valve replacement","volume":"102","author":"Rao","year":"2000","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2008.08.019_bib13","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1161\/CIRCULATIONAHA.105.587022","article-title":"Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis","volume":"113","author":"Tasca","year":"2006","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2008.08.019_bib14","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1016\/S0022-5223(00)70091-2","article-title":"Aortic valve replacement: is valve size important?","volume":"119","author":"Medalion","year":"2000","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.athoracsur.2008.08.019_bib15","doi-asserted-by":"crossref","first-page":"1822","DOI":"10.1016\/S0003-4975(02)03582-8","article-title":"Patient prosthesis mismatch is rare after aortic valve replacement: valve size may be irrelevant","volume":"73","author":"Hanayama","year":"2002","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2008.08.019_bib16","doi-asserted-by":"crossref","first-page":"1608","DOI":"10.1016\/S0003-4975(97)00127-6","article-title":"Aortic valve replacement with patch enlargement of the aortic annulus","volume":"63","author":"Sommers","year":"1997","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2008.08.019_bib17","doi-asserted-by":"crossref","first-page":"2054","DOI":"10.1016\/j.jacc.2005.03.039","article-title":"Haemodynamic comparison of bioprosthesis for complete supra-annular position in patients with small aortic root annulus","volume":"45","author":"Botzenhardt","year":"2005","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.athoracsur.2008.08.019_bib18","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/S0003-4975(01)02508-5","article-title":"Experience with the 19-mm Carpentier-Edwards pericardial bioprosthesis in the elderly","volume":"71","author":"Carrier","year":"2001","journal-title":"Ann Thorac Surg"}],"container-title":["The Annals of Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003497508017979?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003497508017979?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,13]],"date-time":"2025-09-13T00:47:09Z","timestamp":1757724429000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0003497508017979"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,12]]},"references-count":18,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2008,12]]}},"alternative-id":["S0003497508017979"],"URL":"https:\/\/doi.org\/10.1016\/j.athoracsur.2008.08.019","relation":{},"ISSN":["0003-4975"],"issn-type":[{"type":"print","value":"0003-4975"}],"subject":[],"published":{"date-parts":[[2008,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Hemodynamic Evaluation and Midterm Outcome of Aortic Valve Replacement With Size 19 Perimount Prosthetic Valve","name":"articletitle","label":"Article Title"},{"value":"The Annals of Thoracic Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.athoracsur.2008.08.019","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2008 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}