{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T06:07:50Z","timestamp":1789625270414,"version":"build-2803163510"},"reference-count":31,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2009,12,1]],"date-time":"2009-12-01T00:00:00Z","timestamp":1259625600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2009,12,1]],"date-time":"2009-12-01T00:00:00Z","timestamp":1259625600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["annalsthoracicsurgery.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Annals of Thoracic Surgery"],"published-print":{"date-parts":[[2009,12]]},"DOI":"10.1016\/j.athoracsur.2009.08.025","type":"journal-article","created":{"date-parts":[[2009,11,21]],"date-time":"2009-11-21T04:33:58Z","timestamp":1258778038000},"page":"1857-1863","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":46,"title":["Energy Loss Due to Paravalvular Leak With Transcatheter Aortic Valve Implantation"],"prefix":"10.1016","volume":"88","author":[{"given":"Ali N.","family":"Azadani","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicolas","family":"Jaussaud","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter B.","family":"Matthews","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liang","family":"Ge","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T. Sloane","family":"Guy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timothy A.M.","family":"Chuter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elaine E.","family":"Tseng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.athoracsur.2009.08.025_bib1","doi-asserted-by":"crossref","first-page":"1829","DOI":"10.1016\/j.jacc.2008.11.059","article-title":"Outcomes and safety of percutaneous aortic valve replacement","volume":"53","author":"Zajarias","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib2","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1016\/j.jacc.2003.11.026","article-title":"Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis","volume":"43","author":"Cribier","year":"2004","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib3","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.jacc.2007.04.047","article-title":"Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome","volume":"50","author":"Grube","year":"2007","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib4","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1161\/CIRCULATIONAHA.107.698258","article-title":"Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis","volume":"116","author":"Webb","year":"2007","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib5","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/j.ahj.2008.10.003","article-title":"Percutaneous transcatheter aortic valve implantation: Evolution of the technology","volume":"157","author":"Chiam","year":"2009","journal-title":"Am Heart J"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib6","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1161\/CIRCULATIONAHA.106.632927","article-title":"Transapical transcatheter aortic valve implantation in humans: initial clinical experience","volume":"114","author":"Lichtenstein","year":"2006","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib7","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.athoracsur.2008.04.049","article-title":"United States feasibility study of transcatheter insertion of a stented aortic valve by the left ventricular apex","volume":"86","author":"Svensson","year":"2008","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib8","doi-asserted-by":"crossref","first-page":"1214","DOI":"10.1016\/j.jacc.2006.01.049","article-title":"Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience","volume":"47","author":"Cribier","year":"2006","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib9","doi-asserted-by":"crossref","first-page":"193","DOI":"10.4244\/EIJV4I2A36","volume":"4","author":"Vahanian","year":"2008","journal-title":"EuroIntervention"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib10","doi-asserted-by":"crossref","first-page":"1316","DOI":"10.1136\/heart.89.11.1316","article-title":"Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transoesophageal echocardiography","volume":"89","author":"Ionescu","year":"2003","journal-title":"Heart"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib11","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1038\/ncpcardio1112","article-title":"Surgery Insight: percutaneous treatment of prosthetic paravalvular leaks","volume":"5","author":"Bhindi","year":"2008","journal-title":"Nat Clin Pract Cardiovasc Med"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib12","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1002\/clc.4960210604","article-title":"Evaluation of hemolysis in patients with prosthetic heart valves","volume":"21","author":"Maraj","year":"1998","journal-title":"Clin Cardiol"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib13","doi-asserted-by":"crossref","first-page":"1883","DOI":"10.1016\/j.jacc.2009.01.060","article-title":"Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis","volume":"53","author":"Clavel","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib14","doi-asserted-by":"crossref","first-page":"1892","DOI":"10.1016\/j.jacc.2009.02.016","article-title":"Hemodynamic evaluation of heart valve prostheses paradigm shift for transcatheter valves?","volume":"53","author":"Walther","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib15","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1016\/j.jtcvs.2007.12.059","article-title":"Energy loss for evaluating heart valve performance","volume":"136","author":"Akins","year":"2008","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib16","first-page":"367","article-title":"Aortic valve-in-valve implantation: impact of transcatheter-bioprosthesis size mismatch","volume":"18","author":"Azadani","year":"2009","journal-title":"J Heart Valve Disease"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib17","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1053\/j.semtcvs.2006.08.002","article-title":"Transcatheter aortic valve replacement in patients with critical aortic stenosis: rationale, device descriptions, early clinical experiences, and perspectives","volume":"18","author":"Leon","year":"2006","journal-title":"Semin Thorac Cardiovasc Surg"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib18","unstructured":"Cardiovascular implants - Cardiac valve prostheses. ISO 5840:2005."},{"key":"10.1016\/j.athoracsur.2009.08.025_bib19","first-page":"1","article-title":"Draft replacement heart valve guidance, version 4.1","year":"1994"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib20","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1007\/BF02684181","article-title":"Experimental analysis of fluid mechanical energy losses in aortic valve stenosis: importance of pressure recovery","volume":"24","author":"Heinrich","year":"1996","journal-title":"Ann Biomed Eng"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib21","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1148\/radiology.167.2.3357951","article-title":"Mitral or aortic regurgitation: quantification of regurgitant volumes with cine MR imaging","volume":"167","author":"Sechtem","year":"1988","journal-title":"Radiology"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib22","doi-asserted-by":"crossref","first-page":"1240","DOI":"10.1016\/j.amjcard.2008.06.061","article-title":"Feasibility and initial results of percutaneous aortic valve implantation including selection of the transfemoral or transapical approach in patients with severe aortic stenosis","volume":"102","author":"Rod\u00e9s-Cabau","year":"2008","journal-title":"Am J Cardiol"},{"issue":"11 suppl","key":"10.1016\/j.athoracsur.2009.08.025_bib23","first-page":"I240","article-title":"Transapical minimally invasive aortic valve implantation: multicenter experience","volume":"116","author":"Walther","year":"2007","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib24","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1161\/01.CIR.101.7.765","article-title":"Assessment of aortic valve stenosis severity: A new index based on the energy loss concept","volume":"101","author":"Garcia","year":"2000","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib25","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/S0735-1097(02)02627-X","article-title":"Clinical efficacy of Doppler-echocardiographic indices of aortic valve stenosis: a comparative test-based analysis of outcome","volume":"41","author":"Bermejo","year":"2003","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib26","first-page":"142","article-title":"Left ventricular longitudinal shortening in patients with aortic stenosis: relationship with symptomatic status","volume":"12","author":"Tongue","year":"2003","journal-title":"J Heart Valve Dis"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib27","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1016\/S1010-7940(05)80127-7","article-title":"Comparative study of the hydrodynamic function of six size 19 mm bileaflet heart valves","volume":"9","author":"Fisher","year":"1995","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib28","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1055\/s-2005-865689","article-title":"Different tilting disc valves show similar rotation-dependent impairment in hemodynamic performance under a tilted implantation position","volume":"53","author":"Hartrumpf","year":"2005","journal-title":"Thorac Cardiovasc Surg"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib29","doi-asserted-by":"crossref","first-page":"1935","DOI":"10.1016\/j.jbiomech.2009.05.020","article-title":"A method for the measurement of left ventricular overload for aortic valve insufficiency","volume":"42","author":"Travis","year":"2009","journal-title":"J Biomech"},{"issue":"5 suppl","key":"10.1016\/j.athoracsur.2009.08.025_bib30","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1111\/j.1445-5994.1992.tb00473.x","article-title":"Left ventricular energy in mitral regurgitation: a preliminary report","volume":"22","author":"MacIsaac","year":"1992","journal-title":"Aust N Z J Med"},{"key":"10.1016\/j.athoracsur.2009.08.025_bib31","first-page":"613","article-title":"Left ventricular stroke work in mitral regurgitation: an animal experimental study","volume":"6","author":"Teien","year":"1997","journal-title":"J Heart Valve Dis"}],"container-title":["The Annals of Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003497509017329?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003497509017329?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,13]],"date-time":"2025-09-13T00:53:42Z","timestamp":1757724822000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0003497509017329"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,12]]},"references-count":31,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2009,12]]}},"alternative-id":["S0003497509017329"],"URL":"https:\/\/doi.org\/10.1016\/j.athoracsur.2009.08.025","relation":{},"ISSN":["0003-4975"],"issn-type":[{"value":"0003-4975","type":"print"}],"subject":[],"published":{"date-parts":[[2009,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Energy Loss Due to Paravalvular Leak With Transcatheter Aortic Valve Implantation","name":"articletitle","label":"Article Title"},{"value":"The Annals of Thoracic Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.athoracsur.2009.08.025","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2009 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}