{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T22:22:42Z","timestamp":1761862962313,"version":"3.44.0"},"reference-count":29,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2011,1,1]],"date-time":"2011-01-01T00:00:00Z","timestamp":1293840000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2011,1,1]],"date-time":"2011-01-01T00:00:00Z","timestamp":1293840000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["annalsthoracicsurgery.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Annals of Thoracic Surgery"],"published-print":{"date-parts":[[2011,1]]},"DOI":"10.1016\/j.athoracsur.2010.08.036","type":"journal-article","created":{"date-parts":[[2010,12,19]],"date-time":"2010-12-19T04:06:15Z","timestamp":1292731575000},"page":"71-77","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":21,"title":["Aortic Valve Replacement With 17-mm Mechanical Prostheses: Is Patient\u2013Prosthesis Mismatch a Relevant Phenomenon?"],"prefix":"10.1016","volume":"91","author":[{"given":"Andrea","family":"Garatti","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francesca","family":"Mori","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francesco","family":"Innocente","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alberto","family":"Canziani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Piervincenzo","family":"Gagliardotto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eugenio","family":"Mossuto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tiberio","family":"Santoro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vincenzo","family":"Montericcio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alessandro","family":"Frigiola","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lorenzo","family":"Menicanti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.athoracsur.2010.08.036_bib1","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1161\/01.CIR.58.1.20","article-title":"The problem of valve prosthesis-patient mismatch","volume":"58","author":"Rahimtoola","year":"1978","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib2","first-page":"211","article-title":"Impact of prosthesis-patient mismatch on hemodynamic and symptomatic status, morbidity and mortality after aortic valve replacement with a bioprosthetic heart valve","volume":"7","author":"Pibarot","year":"1998","journal-title":"J Heart Valve Dis"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib3","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1161\/01.CIR.0000085167.67105.32","article-title":"Impact of valve prosthesis-patient mismatch on early mortality after aortic valve replacement","volume":"108","author":"Blais","year":"2003","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib4","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1016\/S0022-5223(03)00591-9","article-title":"Prosthesis size and long-term survival after aortic valve replacement","volume":"126","author":"Blackstone","year":"2003","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib5","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/S0003-4975(02)03680-9","article-title":"Routine enlargement of the small aortic root: a preventive strategy to minimize mismatch","volume":"74","author":"Castro","year":"2002","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib6","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1016\/s1010-7940(02)00815-1","article-title":"Performance of stentless versus stented aortic valve bioprostheses in the elderly patient: a prospective randomized trial","volume":"23","author":"Doss","year":"2003","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib7","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1067\/mtc.2001.116205","article-title":"Clinical evaluation of St Jude Medical Hemodynamic Plus versus standard aortic valve prostheses: the Italian multicenter, prospective, randomized study","volume":"122","author":"Vitale","year":"2001","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib8","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1161\/01.CIR.55.4.613","article-title":"Echocardiographic determination of left ventricular mass in man: anatomic validation of the method","volume":"55","author":"Devereux","year":"1977","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib9","doi-asserted-by":"crossref","first-page":"1490","DOI":"10.1016\/j.athoracsur.2007.12.082","article-title":"Guidelines for reporting mortality and morbidity after cardiac valve interventions","volume":"85","author":"Akins","year":"2008","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib10","first-page":"216","article-title":"Aortic valve replacement with 19-mm bileaflet prostheses in the elderly: left ventricular mass regression and quality of life","volume":"17","author":"Vicchio","year":"2008","journal-title":"J Heart Valve Dis"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib11","doi-asserted-by":"crossref","first-page":"1303","DOI":"10.1016\/j.athoracsur.2007.12.031","article-title":"Long-term results of aortic valve replacement with a small St. Jude medical valve in Japanese patients","volume":"85","author":"Yoshikawa","year":"2008","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib12","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1016\/j.jtcvs.2004.07.007","article-title":"Left ventricular mass regression after aortic valve replacement with 17-mm St Jude Medical mechanical prostheses in isolated aortic stenosis","volume":"129","author":"Amarelli","year":"2005","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib13","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.athoracsur.2008.09.051","article-title":"The 17-mm St. Jude Medical Regent valve is a valid option for patients with a small aortic annulus","volume":"87","author":"Okamura","year":"2009","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib14","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1177\/021849230801600306","article-title":"Echocardiographic follow-up after implanting 17-mm Regent mechanical prostheses","volume":"16","author":"Casali","year":"2008","journal-title":"Asian Cardiovasc Thorac Ann"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib15","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1016\/S0003-4975(00)02326-2","article-title":"Aortic valve replacement in geriatric patients: determinants of in-hospital mortality","volume":"71","author":"Bloomstein","year":"2001","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib16","doi-asserted-by":"crossref","first-page":"1379","DOI":"10.1016\/j.athoracsur.2006.05.021","article-title":"Root replacement using stentless valves in the small aortic root: a propensity score analysis","volume":"82","author":"Kunihara","year":"2006","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib17","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.athoracsur.2007.07.058","article-title":"Enlargement of the small aortic root during aortic valve replacement: is there a benefit?","volume":"85","author":"Kulik","year":"2008","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib18","doi-asserted-by":"crossref","first-page":"1914","DOI":"10.1016\/j.athoracsur.2009.01.054","article-title":"Sutureless aortic valve replacement with the 3f Enable aortic bioprosthesis","volume":"87","author":"Martens","year":"2009","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib19","first-page":"698","article-title":"Sutureless Perceval S aortic valve replacement: a multicenter, prospective pilot trial","volume":"18","author":"Shrestha","year":"2009","journal-title":"J Heart Valve Dis"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib20","first-page":"e84","article-title":"ACC\/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology\/American Heart Association","volume":"114","author":"Bonow","year":"2006","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib21","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1016\/S1010-7940(97)00306-0","article-title":"Mechanical versus biological isolated aortic valvular replacement after the age of 70: equivalent long-term results","volume":"13","author":"Ninet","year":"1998","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib22","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1177\/021849230601400304","article-title":"Late mortality and morbidity in elderly patients with mechanical heart valves","volume":"14","author":"Sawaki","year":"2006","journal-title":"Asian Cardiovasc Thorac Ann"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib23","doi-asserted-by":"crossref","first-page":"1296","DOI":"10.1016\/j.athoracsur.2007.12.018","article-title":"Aortic valve replacement in octogenarians: is biologic valve the unique solution?","volume":"85","author":"De Vincentiis","year":"2008","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib24","doi-asserted-by":"crossref","first-page":"2050","DOI":"10.1016\/j.athoracsur.2007.01.044","article-title":"Aortic valve replacement with 17-mm St. Jude Medical prostheses for a small aortic root in elderly patients","volume":"83","author":"Takaseya","year":"2007","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib25","doi-asserted-by":"crossref","first-page":"1131","DOI":"10.1016\/S0735-1097(00)00859-7","article-title":"Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention","volume":"36","author":"Pibarot","year":"2000","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib26","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1161\/CIRCULATIONAHA.105.587022","article-title":"Impact of prosthesis-patient mismatch on short term on cardiac events and mid-term mortality after aortic valve replacement in patients with pure aortic stenosis","volume":"113","author":"Tasca","year":"2006","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib27","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1161\/01.CIR.0000085167.67105.32","article-title":"Patient prosthesis mismatch affects short- and long-term outcome after aortic valve replacement","volume":"108","author":"Walther","year":"2003","journal-title":"Circulation"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib28","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.ejcts.2006.03.046","article-title":"Patient-prosthesis mismatch does not affect survival following aortic valve replacement","volume":"30","author":"Howell","year":"2006","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.athoracsur.2010.08.036_bib29","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.jacc.2008.09.022","article-title":"Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: influence of age, obesity and left ventricular dysfunction","volume":"53","author":"Mohty","year":"2009","journal-title":"J Am Coll Cardiol"}],"container-title":["The Annals of Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003497510018886?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003497510018886?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,13]],"date-time":"2025-09-13T00:57:37Z","timestamp":1757725057000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0003497510018886"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,1]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2011,1]]}},"alternative-id":["S0003497510018886"],"URL":"https:\/\/doi.org\/10.1016\/j.athoracsur.2010.08.036","relation":{},"ISSN":["0003-4975"],"issn-type":[{"type":"print","value":"0003-4975"}],"subject":[],"published":{"date-parts":[[2011,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Aortic Valve Replacement With 17-mm Mechanical Prostheses: Is Patient\u2013Prosthesis Mismatch a Relevant Phenomenon?","name":"articletitle","label":"Article Title"},{"value":"The Annals of Thoracic Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.athoracsur.2010.08.036","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}