{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,28]],"date-time":"2025-11-28T12:27:48Z","timestamp":1764332868166,"version":"build-2065373602"},"reference-count":7,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2020,7,1]],"date-time":"2020-07-01T00:00:00Z","timestamp":1593561600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,7,1]],"date-time":"2020-07-01T00:00:00Z","timestamp":1593561600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["annalsofvascularsurgery.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Annals of Vascular Surgery"],"published-print":{"date-parts":[[2020,7]]},"DOI":"10.1016\/j.avsg.2020.05.011","type":"journal-article","created":{"date-parts":[[2020,5,15]],"date-time":"2020-05-15T14:29:07Z","timestamp":1589552947000},"page":"18-23","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":18,"special_numbering":"C","title":["Endovascular Treatment of a Ruptured Pararenal Abdominal Aortic Aneurysm in a Patient With Coronavirus Disease-2019: Suggestions and Case Report"],"prefix":"10.1016","volume":"66","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9545-4897","authenticated-orcid":false,"given":"Luigi Federico","family":"Rinaldi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giulia","family":"Marazzi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Enrico Maria","family":"Marone","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.avsg.2020.05.011_bib1","doi-asserted-by":"crossref","first-page":"104371","DOI":"10.1016\/j.jcv.2020.104371","article-title":"Prevalence and severity of corona virus disease 2019 (COVID-19): a systematic review and meta-analysis","volume":"127","author":"Hu","year":"2020","journal-title":"J Clin Virol"},{"key":"10.1016\/j.avsg.2020.05.011_bib2","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1583\/1545-1550-20.2.159","article-title":"Comparison of outcomes with open, fenestrated, and chimney graft repair of juxtarenal aneurysms: are we ready for a paradigm shift?","volume":"20","author":"Katsargyris","year":"2013","journal-title":"J Endovasc Ther"},{"key":"10.1016\/j.avsg.2020.05.011_bib3","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1016\/j.jvs.2015.09.023","article-title":"Outcome of visceral chimney grafts after urgent endovascular repair of complex aortic lesions","volume":"63","author":"Bin Jabr","year":"2016","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.avsg.2020.05.011_bib4","doi-asserted-by":"crossref","first-page":"2061","DOI":"10.1093\/eurheartj\/ehv125","article-title":"Endovascular strategy or open repair for ruptured abdominal aortic aneurysm: one-year outcomes from the IMPROVE randomized trial","volume":"36","year":"2015","journal-title":"Eur Heart J"},{"key":"10.1016\/j.avsg.2020.05.011_bib5","doi-asserted-by":"crossref","first-page":"1557","DOI":"10.1002\/bjs.9274","article-title":"Systematic review of chimney and periscope grafts for endovascular aneurysm repair","volume":"100","author":"Wilson","year":"2013","journal-title":"Br J Surg"},{"key":"10.1016\/j.avsg.2020.05.011_bib6","doi-asserted-by":"crossref","DOI":"10.1016\/j.jvsv.2020.04.004","article-title":"Upsurge of deep venous thrombosis in patients affected by COVID-19: preliminary data and possible explanations","author":"Marone","year":"2020","journal-title":"J Vasc Surg Venous Lymphat Disord"},{"key":"10.1016\/j.avsg.2020.05.011_bib7","doi-asserted-by":"crossref","DOI":"10.1055\/s-0040-1710019","article-title":"Prevention and treatment of venous thromboembolism associated with coronavirus disease 2019 infection: a consensus statement before guidelines","author":"Zhai","year":"2020","journal-title":"Thromb Haemost"}],"container-title":["Annals of Vascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0890509620304015?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0890509620304015?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:58:36Z","timestamp":1760187516000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0890509620304015"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7]]},"references-count":7,"alternative-id":["S0890509620304015"],"URL":"https:\/\/doi.org\/10.1016\/j.avsg.2020.05.011","relation":{},"ISSN":["0890-5096"],"issn-type":[{"type":"print","value":"0890-5096"}],"subject":[],"published":{"date-parts":[[2020,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Endovascular Treatment of a Ruptured Pararenal Abdominal Aortic Aneurysm in a Patient With Coronavirus Disease-2019: Suggestions and Case Report","name":"articletitle","label":"Article Title"},{"value":"Annals of Vascular Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.avsg.2020.05.011","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}