{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,21]],"date-time":"2026-01-21T12:25:33Z","timestamp":1768998333926,"version":"3.49.0"},"reference-count":26,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2021,2,1]],"date-time":"2021-02-01T00:00:00Z","timestamp":1612137600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,2,1]],"date-time":"2021-02-01T00:00:00Z","timestamp":1612137600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2022,2,17]],"date-time":"2022-02-17T00:00:00Z","timestamp":1645056000000},"content-version":"am","delay-in-days":381,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["annalsofvascularsurgery.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Annals of Vascular Surgery"],"published-print":{"date-parts":[[2021,2]]},"DOI":"10.1016\/j.avsg.2020.08.136","type":"journal-article","created":{"date-parts":[[2020,9,11]],"date-time":"2020-09-11T02:41:27Z","timestamp":1599792087000},"page":"48-55","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"special_numbering":"C","title":["Prevention of Retrograde Ascending Aortic Dissection by Cardiac Pacing During Hybrid Surgery for Zone 0 Aortic Arch Repair"],"prefix":"10.1016","volume":"71","author":[{"given":"Lucien","family":"Chassin-Trubert","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Baris Ata","family":"Ozdemir","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arnaud","family":"Roussel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gr\u00e9gory","family":"Dessertenne","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yves","family":"Castier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Canaud","family":"Ludovic","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pierre","family":"Alric","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.avsg.2020.08.136_bib1","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1016\/j.athoracsur.2008.05.011","article-title":"Improving results of open arch replacement","volume":"86","author":"Sundt","year":"2008","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.avsg.2020.08.136_bib2","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.jtcvs.2012.11.044","article-title":"Hybrid approaches in the treatment of aortic arch aneurysm: postoperative and midterm outcomes","volume":"145","author":"Bavaria","year":"2013","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.avsg.2020.08.136_bib3","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.jtcvs.2009.09.022","article-title":"Endovascular repair of aortic arch lesions in high-risk patients or after previous aortic surgery: midterm results","volume":"140","author":"Canaud","year":"2010","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.avsg.2020.08.136_bib4","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1016\/j.jvs.2010.10.053","article-title":"Complications after aortic arch hybrid repair","volume":"53","author":"Geisb\u00fcsch","year":"2011","journal-title":"J Vasc Surg"},{"issue":"11 Suppl","key":"10.1016\/j.avsg.2020.08.136_bib5","first-page":"276","article-title":"European Registry on Endovascular Aortic Repair Complications. Retrograde ascending aortic dissection during or after thoracic aortic stent graft placement: insight from the European registry on endovascular aortic repair complications","volume":"120","author":"Eggebrecht","year":"2009","journal-title":"Circulation"},{"key":"10.1016\/j.avsg.2020.08.136_bib6","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1016\/j.jvs.2011.08.042","article-title":"Hybrid repair of thoracic aortic lesions for zone 0 and 1 in high-risk patients","volume":"55","author":"Vallejo","year":"2012","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.avsg.2020.08.136_bib7","doi-asserted-by":"crossref","first-page":"e004649","DOI":"10.1161\/JAHA.116.004649","article-title":"Retrograde type A aortic dissection after thoracic endovascular aortic repair: a systematic review and meta-analysis","volume":"6","author":"Yanqing","year":"2017","journal-title":"J Am Heart Assoc"},{"key":"10.1016\/j.avsg.2020.08.136_bib8","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.avsg.2010.02.045","article-title":"Retrograde type A dissection after endovascular repair of a \"zone 0\" nondissectiong aortic arch aneurysm","volume":"24","author":"Tshomba","year":"2010","journal-title":"Ann Vasc Surg"},{"key":"10.1016\/j.avsg.2020.08.136_bib9","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1161\/CIRCULATIONAHA.107.759076","article-title":"Retrograde type A aortic dissection after endovascular stent graft placement for treatment of type B dissection","volume":"119","author":"Dong","year":"2009","journal-title":"Circulation"},{"key":"10.1016\/j.avsg.2020.08.136_bib10","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1016\/j.jvs.2009.01.045","article-title":"Proximal aortic perforation after endovascular repair of a type B dissection in a patient with Marfan syndrome","volume":"50","author":"Van Keulen","year":"2009","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.avsg.2020.08.136_bib11","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1016\/j.jvs.2009.05.056","article-title":"Endovascular management of chronic aortic dissection in patients with Marfan syndrome","volume":"50","author":"Nordon","year":"2009","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.avsg.2020.08.136_bib12","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1583\/07-2286.1","article-title":"Thoracic aortic endografting in patients with connective tissue diseases","volume":"15","author":"Geisb\u00fcsch","year":"2008","journal-title":"J Endovasc Ther"},{"key":"10.1016\/j.avsg.2020.08.136_bib13","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1115\/1.1574332","article-title":"Effects of wall motion and compliance on flow patterns in the ascending aorta","volume":"125","author":"Jin","year":"2003","journal-title":"J Biomech Eng"},{"key":"10.1016\/j.avsg.2020.08.136_bib14","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1532\/HSF98.20081032","volume":"11","author":"Ketenci","year":"2008","journal-title":"Heart Surg Forum"},{"key":"10.1016\/j.avsg.2020.08.136_bib15","doi-asserted-by":"crossref","first-page":"1290","DOI":"10.1016\/j.jtcvs.2008.10.006","article-title":"Aortic dissection type A after supra-aortic debranching and implantation of an endovascular stent-graft for type B dissection: a word of caution","volume":"137","author":"Akhyari","year":"2009","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.avsg.2020.08.136_bib16","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1016\/j.jvs.2007.08.055","article-title":"The use of right ventricular pacing to facilitate stent graft deployment in the distal aortic arch: a case report","volume":"47","author":"Moon","year":"2008","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.avsg.2020.08.136_bib17","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/j.athoracsur.2006.01.081","article-title":"Rapid ventricular pacing to lower blood pressure during endograft deployment in the thoracic aorta","volume":"81","author":"Pornratanarangsi","year":"2006","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.avsg.2020.08.136_bib18","doi-asserted-by":"crossref","first-page":"1196","DOI":"10.1016\/j.jvs.2011.10.003","article-title":"A novel approach using pulmonary artery catheter-directed rapid right ventricular pacing to facilitate precise deployment of endografts in the thoracic aorta","volume":"55","author":"Ricotta","year":"2012","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.avsg.2020.08.136_bib19","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1177\/152660280701400411","article-title":"Rapid pacing for better placing: comparison of techniques for precise deployment of endografts in the thoracic aorta","volume":"14","author":"Nienaber","year":"2007","journal-title":"J Endovasc Ther"},{"key":"10.1016\/j.avsg.2020.08.136_bib20","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/j.ijcard.2006.03.058","article-title":"Cardiac pacing in balloon aortic valvuloplasty","volume":"116","author":"David","year":"2007","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.avsg.2020.08.136_bib21","first-page":"199","article-title":"Rapid pacing to facilitate transcatheter prosthetic heart valve implantation","volume":"68","author":"Webb","year":"2006","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.avsg.2020.08.136_bib22","doi-asserted-by":"crossref","first-page":"790","DOI":"10.1067\/mva.2000.103794","article-title":"Nitroglycerin to control blood pressure during endovascular stent-grafting of descending thoracic aortic aneurysms","volume":"31","author":"Bernard","year":"2000","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.avsg.2020.08.136_bib23","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1583\/1074-6218(1996)003<0270:AITCAE>2.0.CO;2","article-title":"Adenosine-induced transient cardiac asystole enhances precise deployment of stent-grafts in the thoracic or abdominal aorta","volume":"3","author":"Dorros","year":"1996","journal-title":"J Endovasc Surg"},{"key":"10.1016\/j.avsg.2020.08.136_bib24","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1177\/152660280000700406","article-title":"Safety and efficacy of high-dose adenosine-induced asystole during endovascular AAA repair","volume":"7","author":"Kahn","year":"2000","journal-title":"J Endovasc Ther"},{"key":"10.1016\/j.avsg.2020.08.136_bib25","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1097\/00000542-199802000-00036","article-title":"Induction of ventricular fibrillation to facilitate endovascular stent graft repair of thoracic aortic aneurysms","volume":"88","author":"Kahn","year":"1998","journal-title":"Anesthesiology"},{"key":"10.1016\/j.avsg.2020.08.136_bib26","doi-asserted-by":"crossref","first-page":"594","DOI":"10.1148\/radiology.215.2.r00ap19594","article-title":"Endovascular stent-graft deployment: temporary vena caval occlusion with balloons to control aortic blood flow-experimental canine study and initial clinical experience","volume":"215","author":"Ishiguchi","year":"2000","journal-title":"Radiology"}],"container-title":["Annals of Vascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0890509620308220?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0890509620308220?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:01:01Z","timestamp":1760187661000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0890509620308220"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2]]},"references-count":26,"alternative-id":["S0890509620308220"],"URL":"https:\/\/doi.org\/10.1016\/j.avsg.2020.08.136","relation":{},"ISSN":["0890-5096"],"issn-type":[{"value":"0890-5096","type":"print"}],"subject":[],"published":{"date-parts":[[2021,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Prevention of Retrograde Ascending Aortic Dissection by Cardiac Pacing During Hybrid Surgery for Zone 0 Aortic Arch Repair","name":"articletitle","label":"Article Title"},{"value":"Annals of Vascular Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.avsg.2020.08.136","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}