{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T03:15:30Z","timestamp":1789614930403,"version":"build-2803163510"},"reference-count":58,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,7,10]],"date-time":"2023-07-10T00:00:00Z","timestamp":1688947200000},"content-version":"vor","delay-in-days":190,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Brain and Spine"],"published-print":{"date-parts":[[2023]]},"DOI":"10.1016\/j.bas.2023.101780","type":"journal-article","created":{"date-parts":[[2023,7,11]],"date-time":"2023-07-11T12:07:46Z","timestamp":1689077266000},"page":"101780","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":17,"special_numbering":"C","title":["Implications of navigation in thoracolumbar pedicle screw placement on screw accuracy and screw diameter\/pedicle width ratio"],"prefix":"10.1016","volume":"3","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7337-2783","authenticated-orcid":false,"given":"Eric","family":"Mandelka","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3955-0339","authenticated-orcid":false,"given":"Jula","family":"Gierse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Felix","family":"Zimmermann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul A.","family":"Gruetzner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jochen","family":"Franke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sven Y.","family":"Vetter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.bas.2023.101780_bib1","doi-asserted-by":"crossref","first-page":"664","DOI":"10.3171\/2010.11.SPINE10177","article-title":"Pedicle screw insertion in the thoracolumbar spine: comparison of 4 guidance techniques in the intact cadaveric spine","volume":"14","author":"Alhabib","year":"2011","journal-title":"J. Neurosurg. Spine"},{"key":"10.1016\/j.bas.2023.101780_bib2","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-022-16709-y","article-title":"Comparison of three imaging and navigation systems regarding accuracy of pedicle screw placement in a sawbone model","volume":"12","author":"Beisemann","year":"2022","journal-title":"Sci. Rep."},{"key":"10.1016\/j.bas.2023.101780_bib3","doi-asserted-by":"crossref","first-page":"E178","DOI":"10.1097\/BSD.0b013e31825dd542","article-title":"Bicortical versus unicortical pedicle screws in direct vertebral rotation: an in vitro experimental study","volume":"25","author":"Bezer","year":"2012","journal-title":"J. Spinal Disord. Tech."},{"key":"10.1016\/j.bas.2023.101780_bib4","doi-asserted-by":"crossref","DOI":"10.1097\/BSD.0000000000000151","article-title":"Minimizing pedicle screw pullout risks: a detailed biomechanical analysis of screw design and placement","volume":"30","author":"Bianco","year":"2017","journal-title":"Clin Spine Surg"},{"key":"10.1016\/j.bas.2023.101780_bib5","doi-asserted-by":"crossref","first-page":"E332","DOI":"10.1097\/BRS.0b013e3181ba0b0c","article-title":"The influence of the insertion technique on the pullout force of pedicle screws: an experimental study","volume":"35","author":"Chatzistergos","year":"2010","journal-title":"Spine (Phila Pa 1976"},{"key":"10.1016\/j.bas.2023.101780_bib6","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.1302\/0301-620X.92B8.24237","article-title":"The biomechanics of pedicle screw-based instrumentation","volume":"92","author":"Cho","year":"2010","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.bas.2023.101780_bib7","doi-asserted-by":"crossref","first-page":"936","DOI":"10.31616\/asj.2018.0276","article-title":"The optimal screw length of lumbar pedicle screws during minimally invasive surgery fixation: a computed tomography-guided evaluation of 771 screws","volume":"13","author":"Chua","year":"2019","journal-title":"Asian Spine J"},{"key":"10.1016\/j.bas.2023.101780_bib8","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1016\/j.spinee.2003.11.010","article-title":"Biomechanical study of pedicle screw fixation in severely osteoporotic bone","volume":"4","author":"Cook","year":"2004","journal-title":"Spine J."},{"key":"10.1016\/j.bas.2023.101780_bib9","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1097\/BRS.0b013e318074d604","article-title":"Complications of thoracic pedicle screws in scoliosis treatment","volume":"32","author":"Di Silvestre","year":"2007","journal-title":"Spine (Phila Pa 1976"},{"key":"10.1016\/j.bas.2023.101780_bib10","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1186\/s12893-022-01814-6","article-title":"Size selection and placement of pedicle screws using robot-assisted versus fluoroscopy-guided techniques for thoracolumbar fractures: possible implications for the screw loosening rate","volume":"22","author":"Du","year":"2022","journal-title":"BMC Surg."},{"key":"10.1016\/j.bas.2023.101780_bib11","doi-asserted-by":"crossref","first-page":"e175","DOI":"10.1016\/j.wneu.2018.06.148","article-title":"Prospective comparative study in spine surgery between O-arm and airo systems: efficacy and radiation exposure","volume":"118","author":"Farah","year":"2018","journal-title":"World Neurosurg"},{"key":"10.1016\/j.bas.2023.101780_bib12","doi-asserted-by":"crossref","first-page":"e24","DOI":"10.1016\/j.wneu.2017.09.091","article-title":"Revision rate of misplaced pedicle screws of the thoracolumbar spine-comparison of three-dimensional fluoroscopy navigation with freehand placement: a systematic analysis and review of the literature","volume":"109","author":"Fichtner","year":"2018","journal-title":"World Neurosurg"},{"key":"10.1016\/j.bas.2023.101780_bib13","first-page":"181","article-title":"Hole preparation techniques for transpedicle screws. Effect on pull-out strength from human cadaveric vertebrae","volume":"16","author":"George","year":"1991","journal-title":"Spine (Phila Pa 1976"},{"key":"10.1016\/j.bas.2023.101780_bib14","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","article-title":"Accuracy of pedicular screw placement in vivo","volume":"15","author":"Gertzbein","year":"1990","journal-title":"Spine"},{"key":"10.1016\/j.bas.2023.101780_bib15","doi-asserted-by":"crossref","first-page":"1771","DOI":"10.1007\/s00586-011-1908-1","article-title":"Inter- and intraobserver reliability assessment of computed tomographic 3D measurement of pedicles in scoliosis and size matching with pedicle screws","volume":"20","author":"Gstoettner","year":"2011","journal-title":"Eur. Spine J."},{"key":"10.1016\/j.bas.2023.101780_bib16","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1097\/BRS.0000000000002173","article-title":"Intraoperative computed tomography versus 3D C-arm imaging for navigated spinal instrumentation","volume":"43","author":"Hecht","year":"2018","journal-title":"Spine (Phila Pa 1976"},{"key":"10.1016\/j.bas.2023.101780_bib17","doi-asserted-by":"crossref","first-page":"957","DOI":"10.1016\/j.spinee.2013.03.012","article-title":"Tapping insertional torque allows prediction for better pedicle screw fixation and optimal screw size selection","volume":"13","author":"Helgeson","year":"2013","journal-title":"Spine J."},{"key":"10.1016\/j.bas.2023.101780_bib18","doi-asserted-by":"crossref","first-page":"2504","DOI":"10.1097\/00007632-199711010-00007","article-title":"Structural characteristics of the pedicle and its role in screw stability","volume":"22","author":"Hirano","year":"1997","journal-title":"Spine (Phila Pa 1976"},{"key":"10.1016\/j.bas.2023.101780_bib19","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1016\/j.orthres.2004.11.002","article-title":"Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses","volume":"23","author":"Hsu","year":"2005","journal-title":"J. Orthop. Res."},{"key":"10.1016\/j.bas.2023.101780_bib20","doi-asserted-by":"crossref","DOI":"10.1007\/s11701-022-01493-8","article-title":"Robotic-assisted spine surgery allows for increased pedicle screw sizes while still improving safety as indicated by elevated triggered electromyographic thresholds","author":"Kanaly","year":"2022","journal-title":"J Robot Surg"},{"key":"10.1016\/j.bas.2023.101780_bib21","doi-asserted-by":"crossref","first-page":"E133","DOI":"10.1097\/BSD.0000000000000178","article-title":"Biomechanical evaluation of the pedicle screw insertion depth effect on screw stability under cyclic loading and subsequent pullout","volume":"28","author":"Karami","year":"2015","journal-title":"J. Spinal Disord. Tech."},{"key":"10.1016\/j.bas.2023.101780_bib22","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1016\/j.aott.2018.03.002","article-title":"Quantitative comparison of a laterally misplaced pedicle screw with a re-directed screw. How much pull-out strength is lost?","volume":"52","author":"Korkmaz","year":"2018","journal-title":"Acta Orthop. Traumatol. Turcica"},{"key":"10.1016\/j.bas.2023.101780_bib23","doi-asserted-by":"crossref","first-page":"E111","DOI":"10.1097\/01.brs.0000254048.79024.8b","article-title":"Pedicle screw placement accuracy: a meta-analysis","volume":"32","author":"Kosmopoulos","year":"2007","journal-title":"Spine (Phila Pa 1976"},{"key":"10.1016\/j.bas.2023.101780_bib24","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1007\/s00276-021-02865-9","article-title":"Morphometric analysis of the lumbar vertebrae and intervertebral discs in relation to abdominal aorta: CT-based study","volume":"44","author":"Kot","year":"2022","journal-title":"Surg. Radiol. Anat."},{"key":"10.1016\/j.bas.2023.101780_bib25","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1097\/00002517-198800140-00002","article-title":"Depth of insertion of transpedicular vertebral screws into human vertebrae: effect upon screw-vertebra interface strength","volume":"1","author":"Krag","year":"1988","journal-title":"J. Spinal Disord."},{"key":"10.1016\/j.bas.2023.101780_bib26","doi-asserted-by":"crossref","first-page":"2058","DOI":"10.1097\/01.BRS.0000087743.57439.4F","article-title":"Straight-forward versus anatomic trajectory technique of thoracic pedicle screw fixation: a biomechanical analysis","volume":"28","author":"Lehman","year":"2003","journal-title":"Spine (Phila Pa 1976"},{"key":"10.1016\/j.bas.2023.101780_bib27","doi-asserted-by":"crossref","first-page":"2438","DOI":"10.1097\/01.brs.0000144355.50660.65","article-title":"Accurate determination of isthmus of lumbar pedicle: a morphometric study using reformatted computed tomographic images","volume":"29","author":"Li","year":"2004","journal-title":"Spine (Phila Pa 1976"},{"key":"10.1016\/j.bas.2023.101780_bib28","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1186\/s13018-020-02111-9","article-title":"Effects of pedicle screw number and insertion depth on radiographic and functional outcomes in lumbar vertebral fracture","volume":"15","author":"Liu","year":"2020","journal-title":"J. Orthop. Surg. Res."},{"key":"10.1016\/j.bas.2023.101780_bib29","first-page":"81","article-title":"Complications associated with pedicle screws","author":"Lonstein","year":"1999","journal-title":"JBJS"},{"key":"10.1016\/j.bas.2023.101780_bib30","doi-asserted-by":"crossref","first-page":"E298","DOI":"10.1097\/BSD.0b013e31828af33e","article-title":"Comparison of navigated versus non-navigated pedicle screw placement in 260 patients and 1434 screws: screw accuracy, screw size, and the complexity of surgery","volume":"28","author":"Luther","year":"2015","journal-title":"J. Spinal Disord. Tech."},{"key":"10.1016\/j.bas.2023.101780_bib31","doi-asserted-by":"crossref","first-page":"1516","DOI":"10.1007\/s00586-012-2199-x","article-title":"Analysis of lumbar pedicle morphology in degenerative spines using multiplanar reconstruction computed tomography: what can be the reliable index for optimal pedicle screw diameter?","volume":"21","author":"Makino","year":"2012","journal-title":"Eur. Spine J."},{"key":"10.1016\/j.bas.2023.101780_bib32","doi-asserted-by":"crossref","DOI":"10.3390\/medicina58081111","article-title":"First clinical experience with a novel 3D C-Arm-Based system for navigated percutaneous thoracolumbar pedicle screw placement","volume":"58","author":"Mandelka","year":"2022","journal-title":"Medicina"},{"key":"10.1016\/j.bas.2023.101780_bib33","doi-asserted-by":"crossref","first-page":"471","DOI":"10.3171\/2015.1.SPINE141103","article-title":"Biomechanical evaluation of the fixation strength of lumbar pedicle screws using cortical bone trajectory: a finite element study","volume":"23","author":"Matsukawa","year":"2015","journal-title":"J. Neurosurg. Spine"},{"key":"10.1016\/j.bas.2023.101780_bib34","doi-asserted-by":"crossref","first-page":"566","DOI":"10.31616\/asj.2020.0353","article-title":"Impact of screw diameter and length on pedicle screw fixation strength in osteoporotic vertebrae: a finite element analysis","volume":"15","author":"Matsukawa","year":"2021","journal-title":"Asian Spine J"},{"key":"10.1016\/j.bas.2023.101780_bib35","article-title":"Influence of pedicle screw insertion depth on posterior lumbar interbody fusion: radiological significance of deeper screw placement","author":"Matsukawa","year":"2022","journal-title":"Global Spine J."},{"key":"10.1016\/j.bas.2023.101780_bib36","doi-asserted-by":"crossref","first-page":"38","DOI":"10.14444\/3038","article-title":"Reliability of the planned pedicle screw trajectory versus the actual pedicle screw trajectory using intra-operative 3D CT and image guidance","volume":"10","author":"Miller","year":"2016","journal-title":"Internet J. Spine Surg."},{"key":"10.1016\/j.bas.2023.101780_bib37","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1097\/00007632-198904000-00004","article-title":"Anatomic analysis of pedicle cortical and cancellous diameter as related to screw size","volume":"14","author":"Misenhimer","year":"1989","journal-title":"Spine (Phila Pa 1976"},{"key":"10.1016\/j.bas.2023.101780_bib38","doi-asserted-by":"crossref","first-page":"469","DOI":"10.3171\/2010.4.SPINE09764","article-title":"Evaluation of pullout strength and failure mechanism of posterior instrumentation in normal and osteopenic thoracic vertebrae","volume":"13","author":"Paxinos","year":"2010","journal-title":"J. Neurosurg. Spine"},{"key":"10.1016\/j.bas.2023.101780_bib39","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1016\/j.wneu.2019.02.217","article-title":"Accuracy of current techniques for placement of pedicle screws in the spine: a comprehensive systematic review and meta-analysis of 51,161 screws","volume":"126","author":"Perdomo-Pantoja","year":"2019","journal-title":"World Neurosurgery"},{"key":"10.1016\/j.bas.2023.101780_bib40","doi-asserted-by":"crossref","DOI":"10.2106\/JBJS.RVW.20.00177","article-title":"Alternatives to traditional pedicle screws for posterior fixation of the degenerative lumbar spine","volume":"9","author":"Rosinski","year":"2021","journal-title":"JBJS Rev"},{"key":"10.1016\/j.bas.2023.101780_bib41","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1016\/j.spinee.2008.07.008","article-title":"Cortical bone trajectory for lumbar pedicle screws","volume":"9","author":"Santoni","year":"2009","journal-title":"Spine J."},{"key":"10.1016\/j.bas.2023.101780_bib42","doi-asserted-by":"crossref","first-page":"397","DOI":"10.3171\/2018.1.SPINE17927","article-title":"Use of the Airo mobile intraoperative CT system versus the O-arm for transpedicular screw fixation in the thoracic and lumbar spine: a retrospective cohort study of 263 patients","volume":"29","author":"Scarone","year":"2018","journal-title":"J. Neurosurg. Spine"},{"key":"10.1016\/j.bas.2023.101780_bib43","doi-asserted-by":"crossref","first-page":"E4","DOI":"10.3171\/2021.10.FOCUS21526","article-title":"Does robot-assisted navigation influence pedicle screw selection and accuracy in minimally invasive spine surgery?","volume":"52","author":"Shafi","year":"2022","journal-title":"Neurosurg. Focus"},{"key":"10.1016\/j.bas.2023.101780_bib44","doi-asserted-by":"crossref","DOI":"10.1155\/2014\/748393","article-title":"Designs and techniques that improve the pullout strength of pedicle screws in osteoporotic vertebrae: current status","volume":"2014","author":"Shea","year":"2014","journal-title":"BioMed Res. Int."},{"key":"10.1016\/j.bas.2023.101780_bib45","doi-asserted-by":"crossref","first-page":"113","DOI":"10.3171\/2012.5.SPINE11399","article-title":"Pedicle screw navigation: a systematic review and meta-analysis of perforation risk for computer-navigated versus freehand insertion","volume":"17","author":"Shin","year":"2012","journal-title":"J. Neurosurg. Spine"},{"key":"10.1016\/j.bas.2023.101780_bib46","doi-asserted-by":"crossref","first-page":"132","DOI":"10.14444\/6018","article-title":"Currently adopted criteria for pedicle screw diameter selection","volume":"13","author":"Solitro","year":"2019","journal-title":"Internet J. Spine Surg."},{"key":"10.1016\/j.bas.2023.101780_bib47","article-title":"How to optimize pedicle screw parameters for the thoracic spine? A biomechanical and finite element method study","author":"Solitro","year":"2022","journal-title":"Global Spine J."},{"key":"10.1016\/j.bas.2023.101780_bib48","doi-asserted-by":"crossref","first-page":"2049","DOI":"10.1097\/00007632-200109150-00022","article-title":"Thoracic pedicle screw fixation in spinal deformities: are they really safe?","volume":"26","author":"Suk","year":"2001","journal-title":"Spine (Phila Pa 1976"},{"key":"10.1016\/j.bas.2023.101780_bib49","doi-asserted-by":"crossref","first-page":"e87","DOI":"10.1016\/j.wneu.2020.07.205","article-title":"Pedicle screw insertion: is O-Arm-Based navigation superior to the conventional freehand technique? A systematic review and meta-analysis","volume":"144","author":"Sun","year":"2020","journal-title":"World Neurosurg"},{"key":"10.1016\/j.bas.2023.101780_bib50","doi-asserted-by":"crossref","first-page":"798","DOI":"10.1097\/BRS.0b013e3181895c36","article-title":"Diameter, length, and direction of pedicle screws for scoliotic spine: analysis by multiplanar reconstruction of computed tomography","volume":"34","author":"Takeshita","year":"2009","journal-title":"Spine (Phila Pa 1976"},{"key":"10.1016\/j.bas.2023.101780_bib51","first-page":"1","article-title":"The comparative accuracy and safety of fluoroscopic and navigation-based techniques in cervical pedicle screw fixation: systematic review and meta-analysis","author":"Tarawneh","year":"2021","journal-title":"J. Neurosurg. Spine"},{"key":"10.1016\/j.bas.2023.101780_bib52","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1007\/s00586-019-06242-4","article-title":"Navigated percutaneous versus open pedicle screw implantation using intraoperative CT and robotic cone-beam CT imaging","volume":"29","author":"Tkatschenko","year":"2020","journal-title":"Eur. Spine J."},{"key":"10.1016\/j.bas.2023.101780_bib53","doi-asserted-by":"crossref","first-page":"1200","DOI":"10.2106\/00004623-199508000-00009","article-title":"Placement of pedicle screws in the thoracic spine. Part II: an anatomical and radiographic assessment","volume":"77","author":"Vaccaro","year":"1995","journal-title":"JBJS"},{"key":"10.1016\/j.bas.2023.101780_bib54","doi-asserted-by":"crossref","first-page":"357","DOI":"10.5435\/JAAOS-D-14-00378","article-title":"Emerging techniques for posterior fixation of the lumbar spine","volume":"24","author":"Verma","year":"2016","journal-title":"J. Am. Acad. Orthop. Surg."},{"key":"10.1016\/j.bas.2023.101780_bib55","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1080\/02688697.2016.1206179","article-title":"O-arm with navigation versus C-arm: a review of screw placement over 3 years at a major trauma center","volume":"30","author":"Verma","year":"2016","journal-title":"Br. J. Neurosurg."},{"key":"10.1016\/j.bas.2023.101780_bib56","doi-asserted-by":"crossref","first-page":"1004","DOI":"10.1097\/BRS.0000000000000351","article-title":"Radiation exposure to the surgeon and the patient during posterior lumbar spinal instrumentation: a prospective randomized comparison of navigated versus non-navigated freehand techniques","volume":"39","author":"Villard","year":"2014","journal-title":"Spine (Phila Pa 1976"},{"key":"10.1016\/j.bas.2023.101780_bib57","first-page":"34","article-title":"Anatomic and technical considerations of pedicle screw fixation","author":"Weinstein","year":"1992","journal-title":"Clin. Orthop. Relat. Res."},{"key":"10.1016\/j.bas.2023.101780_bib58","series-title":"Screw Pull-Out Strength after Pedicle Screw Reposition: a Finite Element Analysis","first-page":"2022","author":"Ye","year":"1976"}],"container-title":["Brain and Spine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2772529423000681?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2772529423000681?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,9]],"date-time":"2025-09-09T11:20:24Z","timestamp":1757416824000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2772529423000681"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023]]},"references-count":58,"alternative-id":["S2772529423000681"],"URL":"https:\/\/doi.org\/10.1016\/j.bas.2023.101780","relation":{},"ISSN":["2772-5294"],"issn-type":[{"value":"2772-5294","type":"print"}],"subject":[],"published":{"date-parts":[[2023]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Implications of navigation in thoracolumbar pedicle screw placement on screw accuracy and screw diameter\/pedicle width ratio","name":"articletitle","label":"Article Title"},{"value":"Brain and Spine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.bas.2023.101780","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Authors. Published by Elsevier B.V. on behalf of EUROSPINE, the Spine Society of Europe, EANS, the European Association of Neurosurgical Societies.","name":"copyright","label":"Copyright"}],"article-number":"101780"}}