{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T08:10:53Z","timestamp":1790755853204,"version":"4.1.0"},"reference-count":136,"publisher":"Elsevier BV","issue":"10","license":[{"start":{"date-parts":[[2021,10,1]],"date-time":"2021-10-01T00:00:00Z","timestamp":1633046400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,10,1]],"date-time":"2021-10-01T00:00:00Z","timestamp":1633046400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2021,2,26]],"date-time":"2021-02-26T00:00:00Z","timestamp":1614297600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003453","name":"Natural Science Foundation of Guangdong Province","doi-asserted-by":"publisher","award":["2019A1515011404"],"award-info":[{"award-number":["2019A1515011404"]}],"id":[{"id":"10.13039\/501100003453","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100015956","name":"Special Project for Research and Development in Key areas of Guangdong Province","doi-asserted-by":"publisher","award":["2020B090924004"],"award-info":[{"award-number":["2020B090924004"]}],"id":[{"id":"10.13039\/501100015956","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100015956","name":"Special Project for Research and Development in Key areas of Guangdong Province","doi-asserted-by":"publisher","award":["T13-402\/17-N"],"award-info":[{"award-number":["T13-402\/17-N"]}],"id":[{"id":"10.13039\/501100015956","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81702165"],"award-info":[{"award-number":["81702165"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Bioactive Materials"],"published-print":{"date-parts":[[2021,10]]},"DOI":"10.1016\/j.bioactmat.2021.02.032","type":"journal-article","created":{"date-parts":[[2021,3,14]],"date-time":"2021-03-14T03:30:11Z","timestamp":1615692611000},"page":"3231-3243","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":34,"title":["Clinical translation and challenges of biodegradable magnesium-based interference screws in ACL reconstruction"],"prefix":"10.1016","volume":"6","author":[{"given":"Ying","family":"Luo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chao","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jue","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fangfei","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kelvin Wingho","family":"Chau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ling","family":"Qin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiali","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"19","key":"10.1016\/j.bioactmat.2021.02.032_bib1","doi-asserted-by":"crossref","first-page":"1751","DOI":"10.2106\/JBJS.L.01705","article-title":"Societal and economic impact of anterior cruciate ligament tears","volume":"95","author":"Mather","year":"2013","journal-title":"J. Bone Joint Surg. Am."},{"issue":"9","key":"10.1016\/j.bioactmat.2021.02.032_bib2","doi-asserted-by":"crossref","DOI":"10.1177\/2325967116666039","article-title":"Predictors of revision surgery after primary anterior cruciate ligament reconstruction","volume":"4","author":"Yabroudi","year":"2016","journal-title":"Orthop. J. Sports Med."},{"issue":"9","key":"10.1016\/j.bioactmat.2021.02.032_bib3","doi-asserted-by":"crossref","first-page":"2242","DOI":"10.1177\/0363546513508376","article-title":"Anterior cruciate ligament injury and radiologic progression of knee osteoarthritis: a systematic review and meta-analysis","volume":"42","author":"Ajuied","year":"2014","journal-title":"Am. J. Sports Med."},{"issue":"Suppl 4","key":"10.1016\/j.bioactmat.2021.02.032_bib4","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/S0020-1383(00)80015-7","article-title":"Stainless steel in bone surgery","volume":"31","author":"Disegi","year":"2000","journal-title":"Injury"},{"issue":"7","key":"10.1016\/j.bioactmat.2021.02.032_bib5","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1016\/j.arthro.2008.02.011","article-title":"Bioabsorbable versus titanium interference screws with hamstring autograft in anterior cruciate ligament reconstruction: a prospective randomized trial with 2-year follow-up","volume":"24","author":"Myers","year":"2008","journal-title":"Arthrosc. J. Arthrosc. Relat. Surg."},{"issue":"1","key":"10.1016\/j.bioactmat.2021.02.032_bib6","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1016\/j.actbio.2010.08.020","article-title":"Bone-implant interface strength and osseointegration: biodegradable magnesium alloy versus standard titanium control","volume":"7","author":"Castellani","year":"2011","journal-title":"Acta Biomater."},{"issue":"5","key":"10.1016\/j.bioactmat.2021.02.032_bib7","doi-asserted-by":"crossref","first-page":"280","DOI":"10.5435\/00124635-200109000-00001","article-title":"Bioabsorbable implants in orthopaedics: new developments and clinical applications","volume":"9","author":"Ciccone","year":"2001","journal-title":"J. Am. Acad. Orthop. Surg."},{"issue":"4","key":"10.1016\/j.bioactmat.2021.02.032_bib8","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1016\/j.arth.2003.12.081","article-title":"The long-term clinical relevance of calcar atrophy caused by stress shielding in total hip arthroplasty: a 10-year, prospective, randomized study","volume":"19","author":"Karachalios","year":"2004","journal-title":"J. Arthroplasty"},{"issue":"10","key":"10.1016\/j.bioactmat.2021.02.032_bib9","doi-asserted-by":"crossref","first-page":"2633","DOI":"10.1002\/jor.24037","article-title":"Improvement of bone-tendon fixation by porous titanium interference screw: a rabbit animal model","volume":"36","author":"Tsai","year":"2018","journal-title":"J. Orthop. Res."},{"issue":"59","key":"10.1016\/j.bioactmat.2021.02.032_bib10","doi-asserted-by":"crossref","first-page":"36058","DOI":"10.1039\/D0RA04857G","article-title":"Recent advances in additive manufacturing of engineering thermoplastics: challenges and opportunities","volume":"10","author":"Picard","year":"2020","journal-title":"RSC Adv."},{"issue":"12","key":"10.1016\/j.bioactmat.2021.02.032_bib11","doi-asserted-by":"crossref","first-page":"1481","DOI":"10.1016\/j.medengphy.2016.09.018","article-title":"Stress shielding in periprosthetic bone following a total knee replacement: effects of implant material, design and alignment","volume":"38","author":"Zhang","year":"2016","journal-title":"Med. Eng. Phys."},{"issue":"12","key":"10.1016\/j.bioactmat.2021.02.032_bib12","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1002\/polb.22259","article-title":"Biomedical applications of biodegradable polymers","volume":"49","author":"Ulery","year":"2011","journal-title":"J. Polym. Sci. B Polym. Phys."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib13","doi-asserted-by":"crossref","first-page":"3117","DOI":"10.2147\/DDDT.S165440","article-title":"Current development of biodegradable polymeric materials for biomedical applications","volume":"12","author":"Song","year":"2018","journal-title":"Drug Des. Dev. Ther."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib14","series-title":"Product Classification","author":"Fda","year":"2019"},{"issue":"10","key":"10.1016\/j.bioactmat.2021.02.032_bib15","doi-asserted-by":"crossref","first-page":"2386","DOI":"10.1177\/0363546519861530","article-title":"A randomized controlled trial of PEEK versus titanium interference screws for anterior cruciate ligament reconstruction with 2-year follow-up","volume":"47","author":"S","year":"2019","journal-title":"Am. J. Sports Med."},{"issue":"27","key":"10.1016\/j.bioactmat.2021.02.032_bib16","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1098\/rsif.2008.0151","article-title":"Biomaterials in orthopaedics","volume":"5","author":"Navarro","year":"2008","journal-title":"J. R. Soc. Interface"},{"key":"10.1016\/j.bioactmat.2021.02.032_bib17","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.biomaterials.2015.01.060","article-title":"Biodegradable poly-lactic acid based-composite reinforced unidirectionally with high-strength magnesium alloy wires","volume":"49","author":"Li","year":"2015","journal-title":"Biomaterials"},{"key":"10.1016\/j.bioactmat.2021.02.032_bib18","series-title":"Materials for Bone Disorders","first-page":"349","article-title":"Polymers and composites for orthopedic applications","author":"Gohil","year":"2017"},{"issue":"1","key":"10.1016\/j.bioactmat.2021.02.032_bib19","article-title":"Biodegradable materials for bone defect repair","volume":"7","author":"Wei","year":"2020","journal-title":"Mil. Med. Res."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.actbio.2017.01.076","article-title":"Biphasic calcium phosphate ceramics for bone reconstruction: a review of biological response","volume":"53","author":"Bouler","year":"2017","journal-title":"Acta Biomater."},{"issue":"1","key":"10.1016\/j.bioactmat.2021.02.032_bib21","article-title":"Alloying design of biodegradable zinc as promising bone implants for load-bearing applications","volume":"11","author":"Yang","year":"2020","journal-title":"Nat. Commun."},{"issue":"2","key":"10.1016\/j.bioactmat.2021.02.032_bib22","first-page":"410","article-title":"Serum zinc levels and multiple health outcomes: implications for zinc-based biomaterials","volume":"5","author":"Qu","year":"2020","journal-title":"Bioact. Mater."},{"issue":"1","key":"10.1016\/j.bioactmat.2021.02.032_bib23","article-title":"Development of a novel biodegradable porous iron-based implant for bone replacement","volume":"10","author":"Wegener","year":"2020","journal-title":"Sci. Rep. (U.K.)"},{"issue":"8","key":"10.1016\/j.bioactmat.2021.02.032_bib24","doi-asserted-by":"crossref","DOI":"10.3390\/ma10080884","article-title":"Metallic biomaterials: current challenges and opportunities","volume":"10","author":"Prasad","year":"2017","journal-title":"Materials"},{"key":"10.1016\/j.bioactmat.2021.02.032_bib25","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1016\/j.biomaterials.2016.10.017","article-title":"Current status on clinical applications of magnesium-based orthopaedic implants: a review from clinical translational perspective","volume":"112","author":"Zhao","year":"2017","journal-title":"Biomaterials"},{"issue":"10","key":"10.1016\/j.bioactmat.2021.02.032_bib26","doi-asserted-by":"crossref","first-page":"1160","DOI":"10.1038\/nm.4162","article-title":"Implant-derived magnesium induces local neuronal production of CGRP to improve bone-fracture healing in rats","volume":"22","author":"Zhang","year":"2016","journal-title":"Nat. Med."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib27","first-page":"32","article-title":"Biomechanical comparison of pure magnesium interference screw and polylactic acid polymer interference screw in anterior cruciate ligament reconstruction-A cadaveric experimental study","volume":"8","author":"Song","year":"2017","journal-title":"J. Orthop. Transl."},{"issue":"4","key":"10.1016\/j.bioactmat.2021.02.032_bib28","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1016\/j.mattod.2017.10.005","article-title":"Engineering vascularized and innervated bone biomaterials for improved skeletal tissue regeneration","volume":"21","author":"Marrella","year":"2018","journal-title":"Mater. Today"},{"key":"10.1016\/j.bioactmat.2021.02.032_bib29","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/j.mattod.2018.05.018","article-title":"Current status and outlook on the clinical translation of biodegradable metals","volume":"23","author":"Han","year":"2019","journal-title":"Mater. Today"},{"issue":"10","key":"10.1016\/j.bioactmat.2021.02.032_bib30","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/S1369-7021(09)70273-1","article-title":"Revolutionizing biodegradable metals","volume":"12","author":"Yun","year":"2009","journal-title":"Mater. Today"},{"key":"10.1016\/j.bioactmat.2021.02.032_bib31","doi-asserted-by":"crossref","DOI":"10.1186\/1475-925X-12-62","article-title":"Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot study","volume":"12","author":"Windhagen","year":"2013","journal-title":"Biomed. Eng. Online"},{"key":"10.1016\/j.bioactmat.2021.02.032_bib32","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1016\/j.biomaterials.2015.11.038","article-title":"Vascularized bone grafting fixed by biodegradable magnesium screw for treating osteonecrosis of the femoral head","volume":"81","author":"Zhao","year":"2016","journal-title":"Biomaterials"},{"issue":"8","key":"10.1016\/j.bioactmat.2021.02.032_bib33","doi-asserted-by":"crossref","first-page":"1902443","DOI":"10.1002\/advs.201902443","article-title":"Biodegradable magnesium-based implants in orthopedics-A general review and perspectives","volume":"7","author":"Wang","year":"2020","journal-title":"Adv. Sci."},{"issue":"3","key":"10.1016\/j.bioactmat.2021.02.032_bib34","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1073\/pnas.1518238113","article-title":"Long-term clinical study and multiscale analysis of in vivo biodegradation mechanism of Mg alloy","volume":"113","author":"Lee","year":"2016","journal-title":"Proc. Natl. Acad. Sci. U.S.A."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib35","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.biomaterials.2015.12.005","article-title":"High-purity magnesium interference screws promote fibrocartilaginous entheses regeneration in the anterior cruciate ligament reconstruction rabbit model via accumulation of BMP-2 and VEGF","volume":"81","author":"Cheng","year":"2016","journal-title":"Biomaterials"},{"key":"10.1016\/j.bioactmat.2021.02.032_bib36","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/j.biomaterials.2017.12.007","article-title":"Magnesium alloy based interference screw developed for ACL reconstruction attenuates peri-tunnel bone loss in rabbits","volume":"157","author":"Wang","year":"2018","journal-title":"Biomaterials"},{"key":"10.1016\/j.bioactmat.2021.02.032_bib37","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1016\/j.actbio.2017.09.018","article-title":"Magnesium (Mg) based interference screws developed for promoting tendon graft incorporation in bone tunnel in rabbits","volume":"63","author":"Wang","year":"2017","journal-title":"Acta Biomater."},{"issue":"3","key":"10.1016\/j.bioactmat.2021.02.032_bib38","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1080\/000164700317411870","article-title":"Semitendinosus tendon graft ingrowth in tibial tunnel following ACL reconstruction: a histological study of 2 patients with different types of early graft failure","volume":"71","author":"Eriksson","year":"2000","journal-title":"Acta Orthop. Scand."},{"issue":"10","key":"10.1016\/j.bioactmat.2021.02.032_bib39","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1007\/s00167-008-0584-0","article-title":"Graft healing in anterior cruciate ligament reconstruction","volume":"16","author":"Ekdahl","year":"2008","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"issue":"4","key":"10.1016\/j.bioactmat.2021.02.032_bib40","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1016\/j.arthro.2004.01.005","article-title":"Failure of osteointegration of hamstring tendon autograft after anterior cruciate ligament reconstruction","volume":"20","author":"Song","year":"2004","journal-title":"Arthroscopy"},{"issue":"21","key":"10.1016\/j.bioactmat.2021.02.032_bib41","first-page":"2956","article-title":"ACL reconstruction with hamstrings: how different technique and fixation devices influence bone tunnel enlargement","volume":"17","author":"Iorio","year":"2013","journal-title":"Eur. Rev. Med. Pharmacol. Sci."},{"issue":"5","key":"10.1016\/j.bioactmat.2021.02.032_bib42","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1590\/1413-785220182605199995","article-title":"Bone tunnel enlargement with NON-metallic interference screws IN ACL reconstruction","volume":"26","author":"de Padua","year":"2018","journal-title":"Acta Ortop\u00e9dica Bras."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib43","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.mser.2014.01.001","article-title":"Biodegradable metals","volume":"77","author":"Zheng","year":"2014","journal-title":"Mater. Sci. Eng. R Rep."},{"issue":"6","key":"10.1016\/j.bioactmat.2021.02.032_bib44","doi-asserted-by":"crossref","first-page":"2834","DOI":"10.1016\/j.actbio.2014.02.002","article-title":"Magnesium ion stimulation of bone marrow stromal cells enhances osteogenic activity, simulating the effect of magnesium alloy degradation","volume":"10","author":"Yoshizawa","year":"2014","journal-title":"Acta Biomater."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib45","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1016\/j.actbio.2019.06.001","article-title":"The role of magnesium ions in bone regeneration involves the canonical Wnt signaling pathway","volume":"98","author":"Hung","year":"2019","journal-title":"Acta Biomater."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib46","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1016\/j.actbio.2018.04.032","article-title":"In vivo quantification of hydrogen gas concentration in bone marrow surrounding magnesium fracture fixation hardware using an electrochemical hydrogen gas sensor","volume":"73","author":"Zhao","year":"2018","journal-title":"Acta Biomater."},{"issue":"10","key":"10.1016\/j.bioactmat.2021.02.032_bib47","doi-asserted-by":"crossref","first-page":"8714","DOI":"10.1016\/j.actbio.2012.10.008","article-title":"Fast escape of hydrogen from gas cavities around corroding magnesium implants","volume":"9","author":"Kuhlmann","year":"2013","journal-title":"Acta Biomater."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib48","doi-asserted-by":"crossref","DOI":"10.1155\/2015\/943603","article-title":"The biocompatibility of degradable magnesium interference screws: an experimental study with sheep","volume":"2015","author":"Thormann","year":"2015","journal-title":"BioMed Res. Int."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib49","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/j.pmatsci.2017.04.011","article-title":"Fundamentals and advances in magnesium alloy corrosion","volume":"89","author":"Esmaily","year":"2017","journal-title":"Prog. Mater. Sci."},{"issue":"2","key":"10.1016\/j.bioactmat.2021.02.032_bib50","first-page":"174","article-title":"Magnesium degradation under physiological conditions - best practice","volume":"3","author":"Gonzalez","year":"2018","journal-title":"Bioact. Mater."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib51","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/j.corsci.2014.05.006","article-title":"Corrosion of magnesium alloy AZ31: the influence of bicarbonate, sulphate, hydrogen phosphate and dihydrogen phosphate ions in saline solution","volume":"86","author":"Zeng","year":"2014","journal-title":"Corrosion Sci."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib52","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1016\/j.jcis.2012.10.047","article-title":"A study on the interfacial chemistry of magnesium hydroxide surfaces in aqueous phosphate solutions: influence of Ca2+, Cl- and protein","volume":"393","author":"Gray-Munro","year":"2013","journal-title":"J. Colloid Interface Sci."},{"issue":"5","key":"10.1016\/j.bioactmat.2021.02.032_bib53","doi-asserted-by":"crossref","first-page":"1559","DOI":"10.1016\/j.msec.2008.12.015","article-title":"Effect of inorganic salts, amino acids and proteins on the degradation of pure magnesium in vitro","volume":"29","author":"Yamamoto","year":"2009","journal-title":"Mater. Sci. Eng. C Biomim. Supramol. Syst."},{"issue":"2","key":"10.1016\/j.bioactmat.2021.02.032_bib54","first-page":"318","article-title":"In vitro degradation of pure magnesium-the synergetic influences of glucose and albumin","volume":"5","author":"Yan","year":"2020","journal-title":"Bioact. Mater."},{"issue":"1\u20132","key":"10.1016\/j.bioactmat.2021.02.032_bib55","doi-asserted-by":"crossref","first-page":"500","DOI":"10.1016\/j.jallcom.2010.02.088","article-title":"Influence of chloride, sulfate and bicarbonate anions on the corrosion behavior of AZ31 magnesium alloy","volume":"496","author":"Wang","year":"2010","journal-title":"J. Alloys Compd."},{"issue":"10","key":"10.1016\/j.bioactmat.2021.02.032_bib56","doi-asserted-by":"crossref","first-page":"8761","DOI":"10.1016\/j.actbio.2013.03.026","article-title":"Effect of biologically relevant ions on the corrosion products formed on alloy AZ31B: an improved understanding of magnesium corrosion","volume":"9","author":"Jang","year":"2013","journal-title":"Acta Biomater."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib57","doi-asserted-by":"crossref","first-page":"13026","DOI":"10.1038\/srep13026","article-title":"In vitro degradation of pure Mg in response to glucose","volume":"5","author":"Zeng","year":"2015","journal-title":"Sci. Rep."},{"issue":"3","key":"10.1016\/j.bioactmat.2021.02.032_bib58","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1007\/s11706-017-0391-y","article-title":"In vitro corrosion of Mg-Ca alloy - the influence of glucose content","volume":"11","author":"Cui","year":"2017","journal-title":"Front. Mater. Sci."},{"issue":"1","key":"10.1016\/j.bioactmat.2021.02.032_bib59","doi-asserted-by":"crossref","first-page":"14335","DOI":"10.1038\/s41598-017-14479-6","article-title":"The effects of serum proteins on magnesium alloy degradation in vitro","volume":"7","author":"Johnson","year":"2017","journal-title":"Sci. Rep."},{"issue":"10","key":"10.1016\/j.bioactmat.2021.02.032_bib60","doi-asserted-by":"crossref","first-page":"3341","DOI":"10.1016\/j.corsci.2010.06.003","article-title":"In vitro corrosion degradation behaviour of Mg\u2013Ca alloy in the presence of albumin","volume":"52","author":"Liu","year":"2010","journal-title":"Corrosion Sci."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib61","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1016\/j.actbio.2019.02.013","article-title":"Different effects of single protein vs. protein mixtures on magnesium degradation under cell culture conditions","volume":"98","author":"Hou","year":"2019","journal-title":"Acta Biomater."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib62","doi-asserted-by":"crossref","first-page":"943603","DOI":"10.1155\/2015\/943603","article-title":"The biocompatibility of degradable magnesium interference screws: an experimental study with sheep","volume":"2015","author":"Thormann","year":"2015","journal-title":"BioMed Res. Int."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib63","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1016\/j.actbio.2017.09.018","article-title":"Magnesium (Mg) based interference screws developed for promoting tendon graft incorporation in bone tunnel in rabbits","volume":"63","author":"Wang","year":"2017","journal-title":"Acta Biomater."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib64","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1016\/j.compstruct.2016.01.091","article-title":"Experimental response of additively manufactured metallic pentamode materials confined between stiffening plates","volume":"142","author":"Amendola","year":"2016","journal-title":"Compos. Struct."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib65","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.jmbbm.2018.07.022","article-title":"Mechanical properties of magnesium alloys for medical application: a review","volume":"87","author":"Chen","year":"2018","journal-title":"J. Mech. Behav. Biomed. Mater."},{"issue":"11","key":"10.1016\/j.bioactmat.2021.02.032_bib66","doi-asserted-by":"crossref","first-page":"2757","DOI":"10.1016\/S1875-5372(17)30035-8","article-title":"Effect of Zn on microstructures and properties of Mg-Zn alloys prepared by powder metallurgy method","volume":"45","author":"Yu","year":"2016","journal-title":"Rare Met. Mater. Eng."},{"issue":"10","key":"10.1016\/j.bioactmat.2021.02.032_bib67","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1016\/j.biomaterials.2007.12.021","article-title":"The development of binary Mg-Ca alloys for use as biodegradable materials within bone","volume":"29","author":"Li","year":"2008","journal-title":"Biomaterials"},{"issue":"6","key":"10.1016\/j.bioactmat.2021.02.032_bib68","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1002\/maco.201206903","article-title":"In vitro mechanical and corrosion properties of biodegradable Mg-Ag alloys","volume":"65","author":"Tie","year":"2014","journal-title":"Mater. Corros."},{"issue":"14","key":"10.1016\/j.bioactmat.2021.02.032_bib69","doi-asserted-by":"crossref","first-page":"1912","DOI":"10.1039\/C3TB21746A","article-title":"Effects of alloying elements on the corrosion behavior and biocompatibility of biodegradable magnesium alloys: a review","volume":"2","author":"Ding","year":"2014","journal-title":"J. Mater. Chem. B"},{"issue":"8","key":"10.1016\/j.bioactmat.2021.02.032_bib70","doi-asserted-by":"crossref","first-page":"1667","DOI":"10.1016\/j.msec.2011.07.015","article-title":"Mechanical properties, degradation performance and cytotoxicity of Mg-Zn-Ca biomedical alloys with different compositions","volume":"31","author":"Zhang","year":"2011","journal-title":"Mater. Sci. Eng. C"},{"issue":"2","key":"10.1016\/j.bioactmat.2021.02.032_bib71","first-page":"275","article-title":"In vitro and in vivo degradation behavior of Mg-2Sr-Ca and Mg-2Sr-Zn alloys","volume":"5","author":"Chen","year":"2020","journal-title":"Bioact. Mater."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib72","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1016\/j.msea.2006.07.109","article-title":"Microstructure and corrosion behavior of Mg-Zn-Ag alloys","volume":"435","author":"Ben-Hamu","year":"2006","journal-title":"Mater. Sci. Eng. Struct."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib73","doi-asserted-by":"crossref","DOI":"10.1016\/j.matdes.2020.108980","article-title":"Microstructure-corrosion behaviour relationship of micro-alloyed Mg-0.5Zn alloy with the addition of Ca, Sr, Ag, in and Cu","volume":"195","author":"Jin","year":"2020","journal-title":"Mater. Des."},{"issue":"6","key":"10.1016\/j.bioactmat.2021.02.032_bib74","doi-asserted-by":"crossref","first-page":"2612","DOI":"10.1016\/j.corsci.2006.12.011","article-title":"The effects of heat treatment and zirconium on the corrosion behaviour of Mg-3Nd-0.2Zn-0.4Zr (wt.%) alloy","volume":"49","author":"Chang","year":"2007","journal-title":"Corrosion Sci."},{"issue":"17","key":"10.1016\/j.bioactmat.2021.02.032_bib75","doi-asserted-by":"crossref","first-page":"3557","DOI":"10.1016\/j.biomaterials.2004.09.049","article-title":"In vivo corrosion of four magnesium alloys and the associated bone response","volume":"26","author":"Witte","year":"2005","journal-title":"Biomaterials"},{"key":"10.1016\/j.bioactmat.2021.02.032_bib76","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1016\/j.actbio.2016.08.002","article-title":"Biocompatibility and degradation of LAE442-based magnesium alloys after implantation of up to 3.5 years in a rabbit model","volume":"44","author":"Angrisani","year":"2016","journal-title":"Acta Biomater."},{"issue":"4","key":"10.1016\/j.bioactmat.2021.02.032_bib77","doi-asserted-by":"crossref","DOI":"10.1088\/1748-6041\/10\/4\/045015","article-title":"Analysis of metallic traces from the biodegradation of endomedullary AZ31 alloy temporary implants in rat organs after long implantation times","volume":"10","author":"Bodelon","year":"2015","journal-title":"Biomed. Mater."},{"issue":"1","key":"10.1016\/j.bioactmat.2021.02.032_bib78","first-page":"72","article-title":"A review of magnesium\/magnesium alloys corrosion","volume":"1","author":"Guo","year":"2011","journal-title":"Recent Pat. Corros. Sci."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib79","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1016\/j.actbio.2019.12.001","article-title":"Mechanical, corrosion, and biocompatibility properties of Mg-Zr-Sr-Sc alloys for biodegradable implant applications","volume":"102","author":"Munir","year":"2020","journal-title":"Acta Biomater."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib80","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/j.corsci.2015.01.049","article-title":"Improvement of corrosion resistance and biocompatibility of rare-earth WE43 magnesium alloy by neodymium self-ion implantation","volume":"94","author":"Jin","year":"2015","journal-title":"Corrosion Sci."},{"issue":"6","key":"10.1016\/j.bioactmat.2021.02.032_bib81","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1016\/j.biomaterials.2009.11.015","article-title":"Corrosion of, and cellular responses to Mg-Zn-Ca bulk metallic glasses","volume":"31","author":"Gu","year":"2010","journal-title":"Biomaterials"},{"issue":"11","key":"10.1016\/j.bioactmat.2021.02.032_bib82","doi-asserted-by":"crossref","first-page":"887","DOI":"10.1038\/nmat2542","article-title":"MgZnCa glasses without clinically observable hydrogen evolution for biodegradable implants","volume":"8","author":"Zberg","year":"2009","journal-title":"Nat. Mater."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib83","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.actbio.2016.03.047","article-title":"Recent advances in bulk metallic glasses for biomedical applications","volume":"36","author":"Li","year":"2016","journal-title":"Acta Biomater."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib84","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1016\/j.actbio.2015.07.025","article-title":"In vivo evaluation of a magnesium-based degradable intramedullary nailing system in a sheep model","volume":"25","author":"Rossig","year":"2015","journal-title":"Acta Biomater."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib85","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1016\/j.actbio.2016.03.041","article-title":"Intramedullary Mg2Ag nails augment callus formation during fracture healing in mice","volume":"36","author":"Jahn","year":"2016","journal-title":"Acta Biomater."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib86","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/j.actbio.2018.08.030","article-title":"Advances in functionalized polymer coatings on biodegradable magnesium alloys - a review","volume":"79","author":"Li","year":"2018","journal-title":"Acta Biomater."},{"issue":"6","key":"10.1016\/j.bioactmat.2021.02.032_bib87","doi-asserted-by":"crossref","first-page":"1691","DOI":"10.1002\/jbm.b.32707","article-title":"Surface modification of magnesium alloys developed for bioabsorbable orthopedic implants: a general review","volume":"100","author":"Wang","year":"2012","journal-title":"J. Biomed. Mater. Res. B Appl. Biomater."},{"issue":"7","key":"10.1016\/j.bioactmat.2021.02.032_bib88","doi-asserted-by":"crossref","first-page":"2790","DOI":"10.1016\/j.actbio.2009.01.048","article-title":"A study on alkaline heat treated Mg-Ca alloy for the control of the biocorrosion rate","volume":"5","author":"Gu","year":"2009","journal-title":"Acta Biomater."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib89","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.surfin.2018.11.007","article-title":"Effect of fluoride coatings on the corrosion behavior of Mg-Zn-Er alloys","volume":"14","author":"Panemangalore","year":"2019","journal-title":"Surf. Interfaces"},{"issue":"1","key":"10.1016\/j.bioactmat.2021.02.032_bib90","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1002\/jbm.a.32205","article-title":"Influence of surface modification on the in vitro corrosion rate of magnesium alloy AZ31","volume":"91a","author":"Gray-Munro","year":"2009","journal-title":"J. Biomed. Mater. Res."},{"issue":"51","key":"10.1016\/j.bioactmat.2021.02.032_bib91","doi-asserted-by":"crossref","first-page":"35033","DOI":"10.1021\/acsami.6b12974","article-title":"Enhanced corrosion resistance and biocompatibility of magnesium alloy by Mg-Al-layered double hydroxide","volume":"8","author":"Peng","year":"2016","journal-title":"ACS Appl. Mater. Interfaces"},{"issue":"9","key":"10.1016\/j.bioactmat.2021.02.032_bib92","doi-asserted-by":"crossref","first-page":"908","DOI":"10.1080\/02670844.2019.1661145","article-title":"Electrophoretic deposition of hydroxyapatite coating on biodegradable Mg-4Zn-4Sn-0.6Ca-0.5Mn alloy","volume":"36","author":"Saadati","year":"2020","journal-title":"Surf. Eng."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib93","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1016\/j.corsci.2016.08.013","article-title":"Influence of surface pre-treatment on the deposition and corrosion properties of hydrophobic coatings on a magnesium alloy","volume":"112","author":"Zhang","year":"2016","journal-title":"Corrosion Sci."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib94","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1016\/j.colsurfb.2013.12.011","article-title":"Surface microstructure and in vitro analysis of nanostructured akermanite (Ca2MgSi2O7) coating on biodegradable magnesium alloy for biomedical applications","volume":"117","author":"Razavi","year":"2014","journal-title":"Colloids Surf. B Biointerfaces"},{"issue":"6","key":"10.1016\/j.bioactmat.2021.02.032_bib95","doi-asserted-by":"crossref","first-page":"1691","DOI":"10.1002\/jbm.b.32707","article-title":"Surface modification of magnesium alloys developed for bioabsorbable orthopedic implants: a general review","volume":"100B","author":"Wang","year":"2012","journal-title":"J. Biomed. Mater. Res. B"},{"key":"10.1016\/j.bioactmat.2021.02.032_bib96","doi-asserted-by":"crossref","first-page":"103584","DOI":"10.1016\/j.jmbbm.2019.103584","article-title":"Strength retention, corrosion control and biocompatibility of Mg-Zn-Si\/HA nanocomposites","volume":"103","author":"Parande","year":"2020","journal-title":"J. Mech. Behav. Biomed. Mater."},{"issue":"8","key":"10.1016\/j.bioactmat.2021.02.032_bib97","doi-asserted-by":"crossref","first-page":"2084","DOI":"10.1016\/j.biomaterials.2009.11.111","article-title":"A biodegradable polymer-based coating to control the performance of magnesium alloy orthopaedic implants","volume":"31","author":"Wong","year":"2010","journal-title":"Biomaterials"},{"key":"10.1016\/j.bioactmat.2021.02.032_bib98","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1016\/j.apsusc.2015.07.053","article-title":"In vitro study of polycaprolactone\/bioactive glass composite coatings on corrosion and bioactivity of pure Mg","volume":"355","author":"Yang","year":"2015","journal-title":"Appl. Surf. Sci."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib99","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1016\/j.matdes.2015.07.039","article-title":"Surface nano-crystallization of AZ91D magnesium alloy induced by laser shock processing","volume":"86","author":"Ren","year":"2015","journal-title":"Mater. Des."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib100","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/j.matdes.2013.12.069","article-title":"Corrosion behaviour of laser surface melted magnesium alloy AZ91D","volume":"57","author":"Taltavull","year":"2014","journal-title":"Mater. Des."},{"issue":"7652","key":"10.1016\/j.bioactmat.2021.02.032_bib101","doi-asserted-by":"crossref","DOI":"10.1038\/nature21691","article-title":"Dual-phase nanostructuring as a route to high-strength magnesium alloys","volume":"545","author":"Wu","year":"2017","journal-title":"Nature"},{"key":"10.1016\/j.bioactmat.2021.02.032_bib102","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1016\/j.msea.2017.09.094","article-title":"The deformation behavior of AZ31 Mg alloy with surface mechanical attrition treatment","volume":"707","author":"Meng","year":"2017","journal-title":"Mater. Sci. Eng. Struct."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib103","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1016\/j.msec.2013.11.010","article-title":"Effect of surface mechanical attrition treatment on biodegradable Mg-1Ca alloy","volume":"35","author":"Li","year":"2014","journal-title":"Mater. Sci. Eng. C Mater. Biol. Appl."},{"issue":"1","key":"10.1016\/j.bioactmat.2021.02.032_bib104","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1007\/s42235-020-0007-6","article-title":"Magnesium\/Nano-hydroxyapatite composite for bone reconstruction: the effect of processing method","volume":"17","author":"Khodaei","year":"2020","journal-title":"J. Bionic Eng."},{"issue":"1","key":"10.1016\/j.bioactmat.2021.02.032_bib105","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.jma.2018.11.001","article-title":"Magnesium matrix composites for biomedical applications: a review","volume":"7","author":"Bommala","year":"2019","journal-title":"J. Magnesium Alloys"},{"issue":"7\u20138","key":"10.1016\/j.bioactmat.2021.02.032_bib106","doi-asserted-by":"crossref","first-page":"1193","DOI":"10.1016\/j.compscitech.2009.02.020","article-title":"Improved processing of carbon nanotube\/magnesium alloy composites","volume":"69","author":"Li","year":"2009","journal-title":"Compos. Sci. Technol."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib107","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/j.matlet.2012.01.134","article-title":"Novel PLLA\/magnesium composite for orthopedic applications: a proof of concept","volume":"74","author":"Cifuentes","year":"2012","journal-title":"Mater. Lett."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib108","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1016\/j.actbio.2017.09.018","article-title":"Magnesium (Mg) based interference screws developed for promoting tendon graft incorporation in bone tunnel in rabbits","volume":"63","author":"J","year":"2017","journal-title":"Acta Biomater."},{"issue":"2","key":"10.1016\/j.bioactmat.2021.02.032_bib109","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1093\/rb\/rbw003","article-title":"Opportunities and challenges for the biodegradable magnesium alloys as next-generation biomaterials","volume":"3","author":"Ding","year":"2016","journal-title":"Regen. Biomater."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib110","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1016\/j.colsurfb.2016.04.021","article-title":"Influence of biodegradable polymer coatings on corrosion, cytocompatibility and cell functionality of Mg-2.0Zn-0.98Mn magnesium alloy","volume":"144","author":"Witecka","year":"2016","journal-title":"Colloids Surf., B"},{"issue":"5","key":"10.1016\/j.bioactmat.2021.02.032_bib111","doi-asserted-by":"crossref","first-page":"1333","DOI":"10.1002\/pat.4563","article-title":"Improved antibacterial properties of an Mg-Zn-Ca alloy coated with chitosan nanofibers incorporating silver sulfadiazine multiwall carbon nanotubes for bone implants","volume":"30","author":"Bakhsheshi-Rad","year":"2019","journal-title":"Polym. Adv. Technol."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib112","doi-asserted-by":"crossref","DOI":"10.1016\/j.surfcoat.2019.124898","article-title":"Coating biodegradable magnesium alloys with electrospun poly-L-lactic acid-akermanite-doxycycline nanofibers for enhanced biocompatibility, antibacterial activity, and corrosion resistance","volume":"377","author":"Bakhsheshi-Rad","year":"2019","journal-title":"Surf. Coating. Technol."},{"issue":"2","key":"10.1016\/j.bioactmat.2021.02.032_bib113","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1002\/jbm.a.34718","article-title":"Hydroxyapatite-coated magnesium implants with improved in vitro and in vivo biocorrosion, biocompatibility, and bone response","volume":"102","author":"Kim","year":"2014","journal-title":"J. Biomed. Mater. Res."},{"issue":"8","key":"10.1016\/j.bioactmat.2021.02.032_bib114","doi-asserted-by":"crossref","first-page":"2304","DOI":"10.1016\/j.corsci.2008.05.016","article-title":"Characterization and corrosion studies of ceria thin film based on fluorinated AZ91D magnesium alloy","volume":"50","author":"Zhong","year":"2008","journal-title":"Corrosion Sci."},{"issue":"16","key":"10.1016\/j.bioactmat.2021.02.032_bib115","doi-asserted-by":"crossref","DOI":"10.1002\/admi.202000531","article-title":"Iron ion-doped tricalcium phosphate coatings improve the properties of biodegradable magnesium alloys for biomedical implant application","volume":"7","author":"Antoniac","year":"2020","journal-title":"Adv. Mater. Interfaces"},{"key":"10.1016\/j.bioactmat.2021.02.032_bib116","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/j.corsci.2012.11.037","article-title":"Effects of silicon plasma ion implantation on electrochemical corrosion behavior of biodegradable Mg-Y-RE Alloy","volume":"69","author":"Jamesh","year":"2013","journal-title":"Corrosion Sci."},{"issue":"20","key":"10.1016\/j.bioactmat.2021.02.032_bib117","doi-asserted-by":"crossref","first-page":"7422","DOI":"10.1016\/j.apsusc.2005.08.095","article-title":"Characterization of ceramic PVD thin films on AZ31 magnesium alloys","volume":"252","author":"Wu","year":"2006","journal-title":"Appl. Surf. Sci."},{"issue":"3","key":"10.1016\/j.bioactmat.2021.02.032_bib118","doi-asserted-by":"crossref","first-page":"1046","DOI":"10.1021\/acsbiomaterials.8b00020","article-title":"Regulating degradation behavior by incorporating mesoporous silica for Mg bone implants","volume":"4","author":"Yang","year":"2018","journal-title":"ACS Biomater. Sci. Eng."},{"issue":"33","key":"10.1016\/j.bioactmat.2021.02.032_bib119","doi-asserted-by":"crossref","first-page":"29667","DOI":"10.1021\/acsami.9b11073","article-title":"In vitro osteocompatibility and enhanced biocorrosion resistance of diammonium hydrogen phosphate-pretreated\/poly(ether imide) coatings on magnesium for orthopedic application","volume":"11","author":"Yang","year":"2019","journal-title":"ACS Appl. Mater. Interfaces"},{"issue":"19","key":"10.1016\/j.bioactmat.2021.02.032_bib120","doi-asserted-by":"crossref","DOI":"10.1002\/advs.202001480","article-title":"Nano-dual-phase metallic glass film enhances strength and ductility of a gradient nanograined magnesium alloy","volume":"7","author":"Liu","year":"2020","journal-title":"Adv. Sci."},{"issue":"12","key":"10.1016\/j.bioactmat.2021.02.032_bib121","doi-asserted-by":"crossref","first-page":"3976","DOI":"10.1007\/s00167-014-3325-6","article-title":"Biomechanical characteristics of bioabsorbable magnesium-based (MgYREZr-alloy) interference screws with different threads","volume":"24","author":"Ezechieli","year":"2016","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib122","first-page":"25","article-title":"Design of a new magnesium-based anterior cruciate ligament interference screw using finite element analysis","volume":"20","author":"Mau","year":"2020","journal-title":"J. Orthop. Transl."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib123","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/j.biomaterials.2017.12.007","article-title":"Magnesium alloy based interference screw developed for ACL reconstruction attenuates peri-tunnel bone loss in rabbits","volume":"157","author":"Wang","year":"2018","journal-title":"Biomaterials"},{"key":"10.1016\/j.bioactmat.2021.02.032_bib124","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1016\/j.biomaterials.2018.07.018","article-title":"An innovative Mg\/Ti hybrid fixation system developed for fracture fixation and healing enhancement at load-bearing skeletal site","volume":"180","author":"Tian","year":"2018","journal-title":"Biomaterials"},{"key":"10.1016\/j.bioactmat.2021.02.032_bib125","first-page":"1","article-title":"Hybrid fracture fixation systems developed for orthopaedic applications: a general review","volume":"16","author":"Tian","year":"2019","journal-title":"J. Orthop. Transl."},{"issue":"8","key":"10.1016\/j.bioactmat.2021.02.032_bib126","doi-asserted-by":"crossref","DOI":"10.1002\/advs.201902443","article-title":"Biodegradable magnesium-based implants in orthopedics-A general review and perspectives","volume":"7","author":"Wang","year":"2020","journal-title":"Adv. Sci."},{"key":"10.1016\/j.bioactmat.2021.02.032_bib127","series-title":"Biologically Responsive Biomaterials for Tissue Engineering","first-page":"107","article-title":"Development of bioabsorbable interference screws: how biomaterials composition and clinical and retrieval studies influence the innovative screw design and manufacturing processes","author":"Antoniac","year":"2012"},{"issue":"6","key":"10.1016\/j.bioactmat.2021.02.032_bib128","doi-asserted-by":"crossref","first-page":"535","DOI":"10.2174\/1574888X10666150528153025","article-title":"Mesenchymal stem cells for enhancing biologic healing after anterior cruciate ligament injuries","volume":"10","author":"Jang","year":"2015","journal-title":"Curr. Stem Cell Res. Ther."},{"issue":"6","key":"10.1016\/j.bioactmat.2021.02.032_bib129","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.1016\/j.joca.2015.12.018","article-title":"Not single but periodic injections of synovial mesenchymal stem cells maintain viable cells in knees and inhibit osteoarthritis progression in rats","volume":"24","author":"Ozeki","year":"2016","journal-title":"Osteoarthritis Cartilage"},{"issue":"7","key":"10.1016\/j.bioactmat.2021.02.032_bib130","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1038\/nm.1979","article-title":"TGF-beta1-induced migration of bone mesenchymal stem cells couples bone resorption with formation","volume":"15","author":"Tang","year":"2009","journal-title":"Nat. Med."},{"issue":"9","key":"10.1016\/j.bioactmat.2021.02.032_bib131","doi-asserted-by":"crossref","first-page":"804","DOI":"10.1007\/s00167-006-0051-8","article-title":"Expression of vascular endothelial growth factor and angiogenesis in patellar tendon grafts in the early phase after anterior cruciate ligament reconstruction","volume":"14","author":"Yoshikawa","year":"2006","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"issue":"12","key":"10.1016\/j.bioactmat.2021.02.032_bib132","doi-asserted-by":"crossref","first-page":"2905","DOI":"10.1177\/0363546518787507","article-title":"Bioactive tape with BMP-2 binding peptides captures endogenous growth factors and accelerates healing after anterior cruciate ligament reconstruction","volume":"46","author":"Crispim","year":"2018","journal-title":"Am. J. Sports Med."},{"issue":"5","key":"10.1016\/j.bioactmat.2021.02.032_bib133","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1016\/j.arthro.2006.12.031","article-title":"Tendon-bone healing enhancement using injectable tricalcium phosphate in a dog anterior cruciate ligament reconstruction model","volume":"23","author":"Huangfu","year":"2007","journal-title":"Arthroscopy"},{"issue":"7","key":"10.1016\/j.bioactmat.2021.02.032_bib134","doi-asserted-by":"crossref","first-page":"1290","DOI":"10.1177\/0363546508314396","article-title":"Augmentation of tendon-to-bone healing with a magnesium-based bone adhesive","volume":"36","author":"Gulotta","year":"2008","journal-title":"Am. J. Sports Med."},{"issue":"3","key":"10.1016\/j.bioactmat.2021.02.032_bib135","doi-asserted-by":"crossref","DOI":"10.1177\/2325967114526687","article-title":"Systematic review of biological modulation of healing in anterior cruciate ligament reconstruction","volume":"2","author":"Fu","year":"2014","journal-title":"Orthop. J. Sports Med."},{"issue":"2","key":"10.1016\/j.bioactmat.2021.02.032_bib136","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1002\/jbm.a.35225","article-title":"The crosslinking degree controls the mechanical, rheological, and swelling properties of hyaluronic acid microparticles","volume":"103","author":"Shimojo","year":"2015","journal-title":"J. Biomed. Mater. Res."}],"container-title":["Bioactive Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2452199X2100092X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2452199X2100092X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T15:58:20Z","timestamp":1762531100000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2452199X2100092X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10]]},"references-count":136,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2021,10]]}},"alternative-id":["S2452199X2100092X"],"URL":"https:\/\/doi.org\/10.1016\/j.bioactmat.2021.02.032","relation":{},"ISSN":["2452-199X"],"issn-type":[{"value":"2452-199X","type":"print"}],"subject":[],"published":{"date-parts":[[2021,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Clinical translation and challenges of biodegradable magnesium-based interference screws in ACL reconstruction","name":"articletitle","label":"Article Title"},{"value":"Bioactive Materials","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.bioactmat.2021.02.032","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 The Authors. Publishing services by Elsevier B.V. on behalf of KeAi Communications Co. Ltd.","name":"copyright","label":"Copyright"}]}}