{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T19:08:24Z","timestamp":1790708904445,"version":"4.1.0"},"reference-count":82,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T00:00:00Z","timestamp":1764547200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T00:00:00Z","timestamp":1764547200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,7,21]],"date-time":"2025-07-21T00:00:00Z","timestamp":1753056000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/100012492","name":"Beijing Municipal Outstanding Young Talents","doi-asserted-by":"publisher","award":["JWZQ20240101016"],"award-info":[{"award-number":["JWZQ20240101016"]}],"id":[{"id":"10.13039\/100012492","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["52231010"],"award-info":[{"award-number":["52231010"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100006579","name":"Ministry of Industry and Information Technology of the People&apos;s Republic of China","doi-asserted-by":"publisher","award":["2023.09\\u20132026.09"],"award-info":[{"award-number":["2023.09\\u20132026.09"]}],"id":[{"id":"10.13039\/501100006579","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Bioactive Materials"],"published-print":{"date-parts":[[2025,12]]},"DOI":"10.1016\/j.bioactmat.2025.07.036","type":"journal-article","created":{"date-parts":[[2025,9,7]],"date-time":"2025-09-07T17:34:14Z","timestamp":1757266454000},"page":"666-685","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"special_numbering":"C","title":["A long-term quasi-equivalent in vitro study of high-strength Zn alloy interference screws for anterior cruciate ligament reconstruction"],"prefix":"10.1016","volume":"54","author":[{"given":"Bo-Yao","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhang-Zhi","family":"Shi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiang-Min","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiao-Long","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4048-0603","authenticated-orcid":false,"given":"Yu","family":"Yan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lu-Ning","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.bioactmat.2025.07.036_bib1","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1007\/s00167-010-1255-5","article-title":"The fixation strength of a novel ACL soft-tissue graft fixation device compared with conventional interference screws: a biomechanical study In Vitro","volume":"19","author":"Halewood","year":"2011","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib2","first-page":"637","article-title":"Biology and biomechanics of the anterior cruciate ligament, Clin","volume":"12","author":"Smith","year":"1993","journal-title":"Sports Med."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib3","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/S0749-8063(96)90218-2","article-title":"Interference screw divergence in endoscopic anterior cruciate ligament reconstruction","volume":"12","author":"Dworsky","year":"1996","journal-title":"Arthroscopy"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib4","doi-asserted-by":"crossref","first-page":"572","DOI":"10.2106\/JBJS.J.00269","article-title":"A comparison of the results of anterior cruciate ligament reconstruction using bioabsorbable versus metal interference screws: a meta-analysis","volume":"93","author":"Emond","year":"2011","journal-title":"J. Bone Joint Surg."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib5","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1177\/03635465020300041001","article-title":"How four weeks of implantation affect the strength and stiffness of a tendon graft in a bone tunnel: a study of two fixation devices in an extraarticular model in ovine","volume":"30","author":"Singhatat","year":"2002","journal-title":"Am. J. Sports Med."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib6","doi-asserted-by":"crossref","first-page":"3117","DOI":"10.2147\/DDDT.S165440","article-title":"Current development of biodegradable polymeric materials for biomedical applications, drug","volume":"12","author":"Song","year":"2018","journal-title":"Des. Dev. Ther."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib7","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1002\/polb.22259","article-title":"Biomedical applications of biodegradable polymers","volume":"49","author":"Ulery","year":"2011","journal-title":"J. Polym. Sci., Polym. Phys. Ed."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib8","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1007\/s00167-001-0254-y","article-title":"Secondary intra-articular dislocation of a broken bioabsorbable interference screw after anterior cruciate ligament reconstruction","volume":"10","author":"Werner","year":"2002","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib9","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1007\/s00167-006-0049-2","article-title":"Intraarticular migration of a broken biodegradable interference screw after anterior cruciate ligament reconstruction","volume":"14","author":"Baums","year":"2006","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib10","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1007\/s00402-006-0101-1","article-title":"The migration of a BioScrew\u00ae as a differential diagnosis of knee pain, locking after ACL reconstruction: a report of two cases","volume":"126","author":"Krappel","year":"2006","journal-title":"Arch. Orthop. Trauma. Surg."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib11","first-page":"1","article-title":"Zinc-based alloys for degradable vascular stent applications, acta","volume":"71","author":"Mostaed","year":"2018","journal-title":"Biomater."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib12","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1016\/j.biomaterials.2016.10.017","article-title":"Current status on clinical applications of magnesium-based orthopaedic implants: a review from clinical translational perspective","volume":"112","author":"Zhao","year":"2017","journal-title":"Biomaterials"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib13","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/j.mattod.2018.05.018","article-title":"Current status and outlook on the clinical translation of biodegradable metals","volume":"23","author":"Han","year":"2019","journal-title":"Mater. Today"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib14","first-page":"485","article-title":"Development of a high-strength Zn-Mn-Mg alloy for ligament reconstruction fixation, acta","volume":"119","author":"Sun","year":"2021","journal-title":"Biomaterials"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib15","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/j.jmst.2022.08.015","article-title":"300 MPa grade biodegradable high-strength ductile low-alloy (BHSDLA) Zn-Mn-Mg alloys: an in vitro study","volume":"138","author":"Shi","year":"2023","journal-title":"J. Mater. Sci. Technol."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib16","doi-asserted-by":"crossref","first-page":"887","DOI":"10.1007\/s12613-024-2889-5","article-title":"In Vitro performance of a biodegradable zinc alloy adjustable-loop cortical suspension fixation for anterior cruciate ligament reconstruction","volume":"31","author":"Wang","year":"2024","journal-title":"Int. J. Min. Met. Mater."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib17","first-page":"306","article-title":"Structural and temporal dynamics analysis of zinc-based biomaterials: history, research hotspots and emerging trends","volume":"35","author":"Yuan","year":"2024","journal-title":"Bioact. Mater."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib18","doi-asserted-by":"crossref","first-page":"2084","DOI":"10.1016\/j.biomaterials.2009.11.111","article-title":"A biodegradable polymer-based coating to control the performance of magnesium alloy orthopaedic implants","volume":"31","author":"Wong","year":"2010","journal-title":"Biomaterials"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib19","doi-asserted-by":"crossref","first-page":"821","DOI":"10.1016\/j.arthro.2009.12.026","article-title":"Material properties and composition of soft-tissue fixation","volume":"26","author":"Suchenski","year":"2010","journal-title":"Arthroscopy"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib20","first-page":"15","article-title":"Biodegradable magnesium fixation screw for barrier membranes used in guided bone regeneration","volume":"14","author":"Ka\u010darevi\u0107","year":"2022","journal-title":"Bioact. Mater."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib21","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1590\/1413-785220182605199995","article-title":"Bone tunnel enlargement with non-metallic interference screws in acl reconstruction","volume":"26","author":"de Padua","year":"2018","journal-title":"Acta Ortop\u00e9dica Bras."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib22","doi-asserted-by":"crossref","DOI":"10.1088\/1748-6041\/10\/4\/045015","article-title":"Analysis of metallic traces from the biodegradation of endomedullary AZ31 alloy temporary implants in rat organs after long implantation times","volume":"10","author":"Bodel\u00f3n","year":"2015","journal-title":"Biomed. Mater."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib23","first-page":"369","article-title":"In vivo evaluation of a magnesium-based degradable intramedullary nailing system in a sheep model, acta","volume":"25","author":"R\u00f6ssig","year":"2015","journal-title":"Biomaterials"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib24","first-page":"550","article-title":"Highly plastic Zn-0.3Ca alloy for guided bone regeneration membrane: breaking the trade-off between antibacterial ability and biocompatibility","volume":"42","author":"Li","year":"2024","journal-title":"Bioact. Mater."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib25","article-title":"Strengthening mechanism and biocompatibility of degradable Zn-Mn alloy with different Mn content","volume":"31","author":"Zhu","year":"2022","journal-title":"Mater. Today Commun."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib26","doi-asserted-by":"crossref","DOI":"10.1016\/j.matdes.2021.110289","article-title":"Long-term In Vitro corrosion behavior of Zn-3Ag and Zn-3Ag-0.5Mg alloys considered for biodegradable implant applications","volume":"213","author":"W\u0105troba","year":"2022","journal-title":"Mater. Des."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib27","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1016\/S1875-5372(15)30046-1","article-title":"Crevice corrosion behavior of CP Ti, Ti-6Al-4V alloy and Ti-Ni shape memory alloy in artificial body fluids","volume":"44","author":"Chenghao","year":"2015","journal-title":"Rare Met. Mater. Eng."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib28","first-page":"1230","article-title":"Magnesium alloys for temporary implants in osteosynthesis: in Vivo studies of their degradation and interaction with bone, acta","volume":"8","author":"Kraus","year":"2012","journal-title":"Biomaterials"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib29","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1002\/jbm.820150611","article-title":"Crevice and fretting corrosion of stainless-steel plates and screws","volume":"15","author":"Brown","year":"1981","journal-title":"J. Biomed. Mater. Res."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib30","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1016\/j.actbio.2020.07.052","article-title":"In Vitro fretting crevice corrosion damage of CoCrMo alloys in phosphate buffered saline: debris generation, chemistry and distribution","volume":"114","author":"Zhu","year":"2020","journal-title":"Acta Biomater."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib31","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1007\/s00784-023-05444-x","article-title":"The influence of truncated-conical implant length on primary stability in maxillary and mandibular regions: an in vitro study using polyurethane blocks","volume":"28","author":"Romasco","year":"2023","journal-title":"Clin. Oral Invest."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib32","doi-asserted-by":"crossref","DOI":"10.1007\/s40883-024-00381-x","article-title":"3D-Printed polyurethane scaffolds for bone tissue engineering: techniques and emerging applications, regen","author":"Shanno","year":"2025","journal-title":"Eng. Transl. Med"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib33","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1016\/j.actbio.2019.03.055","article-title":"Enhanced cytocompatibility and antibacterial property of zinc phosphate coating on biodegradable zinc materials","volume":"98","author":"Su","year":"2019","journal-title":"Acta Biomater."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib34","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.corsci.2011.12.039","article-title":"Corrosion behaviour of niobium in phosphate buffered saline solutions with different concentrations of bovine serum albumin","volume":"57","author":"Wang","year":"2012","journal-title":"Corros. Sci."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib35","first-page":"995","article-title":"Electronic structure investigations of \u03b3-Tial","volume":"2","author":"Bailey","year":"1997","journal-title":"Microsc. Microanal."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib36","doi-asserted-by":"crossref","DOI":"10.1016\/j.msea.2019.138626","article-title":"Microstructure evolution of a high-strength low-alloy zn\u2013mn\u2013ca alloy through casting, hot extrusion and warm caliber rolling","volume":"771","author":"Shi","year":"2020","journal-title":"Mater. Sci. Eng. A."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib37","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.corsci.2017.08.005","article-title":"In situ monitoring of crevice corrosion morphology of type 316L stainless steel and repassivation behavior induced by sulfate ions","volume":"127","author":"Aoyama","year":"2017","journal-title":"Corros. Sci."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib38","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1186\/s12938-023-01067-1","article-title":"Calcium-to-phosphorus releasing ratio affects osteoinductivity and osteoconductivity of calcium phosphate bioceramics in bone tissue engineering","volume":"22","author":"Jin","year":"2023","journal-title":"Biomed. Eng. Online"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib39","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1016\/j.jmst.2020.10.076","article-title":"Hierarchical microstructure and two-stage corrosion behavior of a high-performance near-eutectic Zn-Li alloy","volume":"80","author":"Shi","year":"2021","journal-title":"J. Mater. Sci. Technol."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib40","doi-asserted-by":"crossref","first-page":"1795","DOI":"10.1016\/S0584-8539(96)01726-6","article-title":"Effects of pH and metal ions on the conformation of bovine serum albumin in aqueous solution an attenuated total reflection (ATR) FTIR spectroscopic study","volume":"52","author":"Qing","year":"1996","journal-title":"Spectrochim. Acta A."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib41","first-page":"641","article-title":"Mechanical properties, corrosion and degradation behaviors, and In Vitro cytocompatibility of a biodegradable Zn\u20135La alloy for bone-implant applications, acta","volume":"169","author":"Tong","year":"2023","journal-title":"Biomaterials"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib42","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.actbio.2019.01.035","article-title":"The influence of alloying and fabrication techniques on the mechanical properties, biodegradability and biocompatibility of zinc: a comprehensive review","volume":"87","author":"Venezuela","year":"2019","journal-title":"Acta Biomater."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib43","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1016\/j.corsci.2012.08.037","article-title":"The effect of Zn concentration on the corrosion behavior of Mg\u2013xZn alloys","volume":"65","author":"Song","year":"2012","journal-title":"Corros. Sci."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib44","doi-asserted-by":"crossref","DOI":"10.1016\/j.corsci.2021.109520","article-title":"Influence of model environment complexity on corrosion mechanism of biodegradable zinc alloys","volume":"187","author":"Hybasek","year":"2021","journal-title":"Corros. Sci."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib45","article-title":"Biodegradable magnesium screws accelerate fibrous tissue mineralization at the tendon-bone insertion in anterior cruciate ligament reconstruction model of rabbit","volume":"7","author":"Wang","year":"2017","journal-title":"Sci. Rep."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib46","doi-asserted-by":"crossref","DOI":"10.1002\/adma.202207570","article-title":"Surface-roughness-induced plasticity in a biodegradable Zn alloy","volume":"35","author":"Shi","year":"2023","journal-title":"Adv. Mater."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib47","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.jmst.2022.08.002","article-title":"Zn-0.8Mn alloy for degradable structural applications: hot compression behaviors, four dynamic recrystallization mechanisms, and better elevated-temperature strength","volume":"137","author":"Li","year":"2023","journal-title":"J. Mater. Sci. Technol."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib48","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1039\/D1MH01831K","article-title":"Estimating the lower-limit of fracture toughness from ideal-strength calculations","volume":"9","author":"Borgsmiller","year":"2022","journal-title":"Mater. Horiz."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib49","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/j.ijfatigue.2007.02.020","article-title":"Characterization of pitting damage and prediction of remaining fatigue life","volume":"30","author":"van der Walde","year":"2008","journal-title":"Int. J. Fatig."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib50","first-page":"584","article-title":"380 MPa-30% grade biodegradable zn-mn-mg-ca alloy: bimodal grain structure, large work-hardening strain, and enhanced biocompatibility, acta","volume":"193","author":"Li","year":"2025","journal-title":"Biomaterials"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib51","doi-asserted-by":"crossref","first-page":"1008","DOI":"10.1016\/j.jmst.2017.11.026","article-title":"Fabrication and characterization of novel biodegradable Zn-Mn-Cu alloys","volume":"34","author":"Shi","year":"2018","journal-title":"J. Mater. Sci. Technol."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib52","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1016\/j.matdes.2018.02.049","article-title":"Microalloyed Zn-Mn alloys: from extremely brittle to extraordinarily ductile at room temperature","volume":"144","author":"Shi","year":"2018","journal-title":"Mater. Des."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib53","doi-asserted-by":"crossref","DOI":"10.1016\/j.msea.2019.138626","article-title":"Microstructure evolution of a high-strength low-alloy Zn-Mn-Ca alloy through casting, hot extrusion and warm caliber rolling","volume":"771","author":"Shi","year":"2020","journal-title":"Mater. Sci. Eng. A."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib54","doi-asserted-by":"crossref","DOI":"10.1016\/j.msea.2019.138543","article-title":"Microstructure and mechanical properties of extruded and caliber rolled biodegradable Zn-0.8Mn-0.4Ag alloy with high ductility","volume":"770","author":"Chen","year":"2020","journal-title":"Mater. Sci. Eng. A."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib55","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1016\/j.msec.2019.02.044","article-title":"Effects of Ag, Cu or ca addition on microstructure and comprehensive properties of biodegradable Zn-0.8Mn alloy","volume":"99","author":"Shi","year":"2019","journal-title":"Mater. Sci. Eng. C."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib56","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.matdes.2018.11.057","article-title":"Zn13 phase and its core-shell structure in novel biodegradable Zn-Mn-Fe alloys","volume":"162","author":"Shi","year":"2019","journal-title":"Mater. Des."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib57","article-title":"Biodegradable magnesium-based implants in orthopedics\u2014A general review and perspectives","volume":"7","author":"Wang","year":"2020","journal-title":"Adv. Sci."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib58","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.biomaterials.2015.12.005","article-title":"High-purity magnesium interference screws promote fibrocartilaginous entheses regeneration in the anterior cruciate ligament reconstruction rabbit model via accumulation of BMP-2 and VEGF","volume":"81","author":"Cheng","year":"2016","journal-title":"Biomaterials"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib59","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1002\/polb.22259","article-title":"Biomedical applications of biodegradable polymers","volume":"49","author":"Ulery","year":"2011","journal-title":"J. Polym. Sci., Polym. Phys. Ed."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib60","doi-asserted-by":"crossref","DOI":"10.1016\/j.engfailanal.2024.107974","article-title":"Corrosion behavior and failure mechanism of V150 drill pipe in HPHT and ultra-deep drilling process","volume":"158","author":"Chen","year":"2024","journal-title":"Eng. Fail. Anal."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib61","first-page":"4607","article-title":"Zinc alloy-based bone internal fixation screw with antibacterial and anti-osteolytic properties","volume":"6","author":"Qu","year":"2021","journal-title":"Bioact. Mater."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib62","first-page":"358","article-title":"In Vitro and In Vivo studies of Zn-Mn biodegradable metals designed for orthopedic applications, acta","volume":"108","author":"Jia","year":"2020","journal-title":"Biomaterials"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib63","doi-asserted-by":"crossref","first-page":"1728","DOI":"10.1007\/s10853-018-2905-0","article-title":"Influence of solution heat treatment on microstructure and hardness of as-cast biodegradable Zn-Mn alloys","volume":"54","author":"Shi","year":"2019","journal-title":"J. Mater. Sci."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib64","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.matchar.2018.01.021","article-title":"Twinning in MnZn13 intermetallic compound with base-centered monoclinic structure in Zn-0.75Mn alloy","volume":"137","author":"Shi","year":"2018","journal-title":"Mater. Char."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib65","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1007\/s10856-021-06567-x","article-title":"Influence of bovine serum albumin on corrosion behaviour of pure Zn in phosphate buffered saline","volume":"32","author":"Liu","year":"2021","journal-title":"J. Mater. Sci. Mater. Med."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib66","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/j.jmst.2022.09.017","article-title":"Biodegradable Zn-0.5Li alloy rib plate: processing procedure development and In Vitro performance evaluation","volume":"141","author":"Sun","year":"2023","journal-title":"J. Mater. Sci. Technol."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib67","doi-asserted-by":"crossref","first-page":"4957","DOI":"10.1039\/D4BM00965G","article-title":"Crevice corrosion behavior of a biodegradable zn-mn-mg alloy in simulated body fluid","volume":"12","author":"Wang","year":"2024","journal-title":"Biomater. Sci."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib68","doi-asserted-by":"crossref","first-page":"2584","DOI":"10.1016\/j.jmrt.2022.10.059","article-title":"Effect of crevice gap on crevice corrosion initiation and development of 2205 duplex stainless steel in NaCl solution","volume":"21","author":"Luo","year":"2022","journal-title":"J. Mater. Res. Technol."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib69","doi-asserted-by":"crossref","first-page":"8243","DOI":"10.1039\/D2SC01818G","article-title":"Towards the practical application of Zn metal anodes for mild aqueous rechargeable Zn batteries","volume":"13","author":"Dong","year":"2022","journal-title":"Chem. Sci."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib70","doi-asserted-by":"crossref","first-page":"4065","DOI":"10.1016\/j.corsci.2011.08.012","article-title":"The crevice corrosion behaviour of stainless steel in sodium chloride solution","volume":"53","author":"Hu","year":"2011","journal-title":"Corros. Sci."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib71","doi-asserted-by":"crossref","first-page":"2987","DOI":"10.1016\/j.corsci.2005.05.051","article-title":"Computational modeling of cathodic limitations on localized corrosion of wetted SS 316L at room temperature","volume":"47","author":"Cui","year":"2005","journal-title":"Corros. Sci."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib72","first-page":"506","article-title":"A biodegradable Fe\/Zn-3Cu composite with requisite properties for orthopedic applications, acta","volume":"146","author":"Tong","year":"2022","journal-title":"Biomaterials"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib73","doi-asserted-by":"crossref","first-page":"3380","DOI":"10.1016\/j.jma.2021.05.013","article-title":"Evaluation on the corrosion resistance, antibacterial property and osteogenic activity of biodegradable Mg-Ca and Mg-Ca-Zn-Ag alloys","volume":"10","author":"Chen","year":"2022","journal-title":"J. Magnesium Alloys"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib74","doi-asserted-by":"crossref","first-page":"1147","DOI":"10.1128\/AEM.03294-14","article-title":"Mycofumigation by the volatile organic compound-producing fungus Muscodor albus induces bacterial cell death through DNA damage","volume":"81","author":"Alpha","year":"2015","journal-title":"Appl. Environ. Microbiol."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib75","doi-asserted-by":"crossref","first-page":"3038","DOI":"10.1016\/j.jma.2023.08.018","article-title":"Antibacterial mechanism with consequent cytotoxicity of different reinforcements in biodegradable magnesium and zinc alloys: a review","volume":"11","author":"Shahed","year":"2023","journal-title":"J. Magnesium Alloys"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib76","first-page":"61","article-title":"Effects of zinc on the mineralization of bone nodules from human osteoblast-like cells, biol. Trace","volume":"116","author":"Cerovic","year":"2007","journal-title":"Elem. Rese."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib77","doi-asserted-by":"crossref","DOI":"10.1016\/j.jallcom.2024.174669","article-title":"Research status and future prospects of biodegradable Zn-Mg alloys","volume":"993","author":"Ji","year":"2024","journal-title":"J. Alloys Compd."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib78","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1016\/j.cell.2024.11.025","article-title":"The human zinc-binding cysteine proteome","volume":"188","author":"Burger","year":"2025","journal-title":"Cell"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib79","doi-asserted-by":"crossref","first-page":"10945","DOI":"10.1021\/acsomega.3c10344","article-title":"Osteogenesis or apoptosis-twofold effects of Zn2+ on bone marrow mesenchymal stem cells: an in vitro and in vivo study","volume":"9","author":"Liu","year":"2024","journal-title":"ACS Omega"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib80","doi-asserted-by":"crossref","first-page":"2885","DOI":"10.1038\/s41467-021-23005-2","article-title":"TRPM7 kinase-mediated immunomodulation in macrophage plays a central role in magnesium ion-induced bone regeneration","volume":"12","author":"Qiao","year":"2021","journal-title":"Nat. Commun."},{"key":"10.1016\/j.bioactmat.2025.07.036_bib81","first-page":"403","article-title":"Additive manufacturing of Zn-Mg alloy porous scaffolds with enhanced osseointegration: in Vitro and In Vivo studies, acta","volume":"145","author":"Qin","year":"2022","journal-title":"Biomaterials"},{"key":"10.1016\/j.bioactmat.2025.07.036_bib82","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1016\/j.msea.2019.01.089","article-title":"Ultra-fine-grained Zn-0.5Mn alloy processed by multi-pass hot extrusion: grain refinement mechanism and room-temperature superplasticity","volume":"748","author":"Guo","year":"2019","journal-title":"Mater. Sci. Eng. A."}],"container-title":["Bioactive Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2452199X25003299?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2452199X25003299?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,3,7]],"date-time":"2026-03-07T19:43:33Z","timestamp":1772912613000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2452199X25003299"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12]]},"references-count":82,"alternative-id":["S2452199X25003299"],"URL":"https:\/\/doi.org\/10.1016\/j.bioactmat.2025.07.036","relation":{},"ISSN":["2452-199X"],"issn-type":[{"value":"2452-199X","type":"print"}],"subject":[],"published":{"date-parts":[[2025,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A long-term quasi-equivalent in vitro study of high-strength Zn alloy interference screws for anterior cruciate ligament reconstruction","name":"articletitle","label":"Article Title"},{"value":"Bioactive Materials","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.bioactmat.2025.07.036","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Authors. Publishing services by Elsevier B.V. on behalf of KeAi Communications Co. Ltd.","name":"copyright","label":"Copyright"}]}}