{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T12:36:50Z","timestamp":1793450210813,"version":"4.5.0"},"reference-count":60,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,8,1]],"date-time":"2024-08-01T00:00:00Z","timestamp":1722470400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,8,1]],"date-time":"2024-08-01T00:00:00Z","timestamp":1722470400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,8,1]],"date-time":"2024-08-01T00:00:00Z","timestamp":1722470400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2024,8,1]],"date-time":"2024-08-01T00:00:00Z","timestamp":1722470400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2024,8,1]],"date-time":"2024-08-01T00:00:00Z","timestamp":1722470400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2024,8,1]],"date-time":"2024-08-01T00:00:00Z","timestamp":1722470400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2024,8,1]],"date-time":"2024-08-01T00:00:00Z","timestamp":1722470400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"funder":[{"DOI":"10.13039\/501100014824","name":"Department of Pharmaceuticals, Ministry of Chemicals and Fertilizers, India","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100014824","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100020582","name":"National Institute of Pharmaceutical Education and Research, Raebareli","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100020582","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Bioelectrochemistry"],"published-print":{"date-parts":[[2024,8]]},"DOI":"10.1016\/j.bioelechem.2024.108681","type":"journal-article","created":{"date-parts":[[2024,3,14]],"date-time":"2024-03-14T08:08:47Z","timestamp":1710403727000},"page":"108681","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":11,"special_numbering":"C","title":["Label-Free detection of Poly-Cystic Ovarian Syndrome using a highly conductive 2-D rGO\/MoS2\/PANI nanocomposite based immunosensor"],"prefix":"10.1016","volume":"158","author":[{"given":"Gourang","family":"Hari Gupta","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keerthana","family":"Mohan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sumanta","family":"Ghosh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Srivalliputtur","family":"Sarath Babu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ravichandiran","family":"Velyutham","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Govinda","family":"Kapusetti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.bioelechem.2024.108681_b0005","doi-asserted-by":"crossref","first-page":"e1071","DOI":"10.1210\/clinem\/dgaa839","article-title":"Update on PCOS: consequences, challenges, and guiding treatment","volume":"106","author":"Hoeger","year":"2021","journal-title":"J. Clin. Endocrinol. Metab."},{"key":"10.1016\/j.bioelechem.2024.108681_b0010","doi-asserted-by":"crossref","unstructured":"H.J. Teede, C.T. Tay, J.J.E. Laven, A. Dokras, L.J. Moran, T.T. Piltonen, M.F. Costello, J. Boivin, L.M. Redman, J.A. Boyle, Recommendations from the 2023 international evidence-based guideline for the assessment and management of polycystic ovary syndrome, Eur. J. Endocrinol. 189 (2023) G43\u2013G64.","DOI":"10.1210\/clinem\/dgad463"},{"key":"10.1016\/j.bioelechem.2024.108681_b0015","doi-asserted-by":"crossref","first-page":"e0203129","DOI":"10.1371\/journal.pone.0203129","article-title":"Threshold value of anti-mullerian hormone for the diagnosis of polycystic ovary syndrome in chinese women","volume":"13","author":"Yue","year":"2018","journal-title":"PLoS One"},{"key":"10.1016\/j.bioelechem.2024.108681_b0020","doi-asserted-by":"crossref","first-page":"333","DOI":"10.4103\/ijmr.IJMR_1937_17","article-title":"Epidemiology, pathogenesis, genetics & management of polycystic ovary syndrome in India","volume":"150","author":"Ganie","year":"2019","journal-title":"Indian J. Med. Res."},{"key":"10.1016\/j.bioelechem.2024.108681_b0025","doi-asserted-by":"crossref","first-page":"124","DOI":"10.3389\/fphys.2016.00124","article-title":"Poly cystic ovarian syndrome: an updated overview","volume":"7","author":"El Hayek","year":"2016","journal-title":"Front. Physiol."},{"key":"10.1016\/j.bioelechem.2024.108681_b0030","first-page":"145","article-title":"Interactions between androgens","volume":"21","author":"Dewailly","year":"2019","journal-title":"FSH, Anti-Mullerian Hormone and Estradiol during Folliculogenesis in the Human Normal and Polycystic Ovary, M\u00e9decine La Reprod."},{"key":"10.1016\/j.bioelechem.2024.108681_b0035","doi-asserted-by":"crossref","first-page":"941","DOI":"10.1210\/jc.2005-2076","article-title":"Serum anti-mullerian hormone as a surrogate for antral follicle count for definition of the polycystic ovary syndrome","volume":"91","author":"Pigny","year":"2006","journal-title":"J. Clin. Endocrinol. Metab."},{"key":"10.1016\/j.bioelechem.2024.108681_b0040","doi-asserted-by":"crossref","first-page":"1029","DOI":"10.1016\/j.bios.2016.09.074","article-title":"A novel electrochemical sensor based on au@ PANI composites film modified glassy carbon electrode binding molecular imprinting technique for the determination of melamine","volume":"87","author":"Rao","year":"2017","journal-title":"Biosens. Bioelectron."},{"key":"10.1016\/j.bioelechem.2024.108681_b0045","doi-asserted-by":"crossref","first-page":"3332","DOI":"10.1210\/jc.2013-1393","article-title":"Can anti-m\u00fcllerian hormone predict the diagnosis of polycystic ovary syndrome? a systematic review and meta-analysis of extracted data","volume":"98","author":"Iliodromiti","year":"2013","journal-title":"J. Clin. Endocrinol. Metab."},{"key":"10.1016\/j.bioelechem.2024.108681_b0050","doi-asserted-by":"crossref","first-page":"104","DOI":"10.4103\/jhrs.JHRS_149_18","article-title":"Establishing an anti-m\u00fcllerian hormone cutoff for diagnosis of polycystic ovarian syndrome in women of reproductive age-bearing indian ethnicity using the automated anti-m\u00fcllerian hormone assay","volume":"12","author":"Mahajan","year":"2019","journal-title":"J. Hum. Reprod. Sci."},{"key":"10.1016\/j.bioelechem.2024.108681_b0055","doi-asserted-by":"crossref","first-page":"1369","DOI":"10.1111\/aogs.12247","article-title":"Elevated serum levels of anti-m\u00fcllerian hormone can be introduced as a new diagnostic marker for polycystic ovary syndrome","volume":"92","author":"Sahmay","year":"2013","journal-title":"Acta Obstet. Gynecol. Scand."},{"key":"10.1016\/j.bioelechem.2024.108681_b0060","first-page":"1866","article-title":"Anti mullerian hormone: a potential marker for recruited non growing follicle of ovarian pool in women with polycystic ovarian syndrome","volume":"7","author":"Saikumar","year":"2013","journal-title":"J. Clin. Diagnostic Res. JCDR"},{"key":"10.1016\/j.bioelechem.2024.108681_b0065","doi-asserted-by":"crossref","first-page":"3795","DOI":"10.1038\/s41598-018-22176-1","article-title":"Salivary and serum androgens with anti-m\u00fcllerian hormone measurement for the diagnosis of polycystic ovary syndrome","volume":"8","author":"Sathyapalan","year":"2018","journal-title":"Sci. Rep."},{"key":"10.1016\/j.bioelechem.2024.108681_b0070","doi-asserted-by":"crossref","DOI":"10.1155\/2013\/959487","article-title":"How much does AMH really vary in normal women?","volume":"2013","author":"La Marca","year":"2013","journal-title":"Int. J. Endocrinol."},{"key":"10.1016\/j.bioelechem.2024.108681_b0075","doi-asserted-by":"crossref","first-page":"1063","DOI":"10.1016\/j.fertnstert.2015.12.023","article-title":"Comparative assessment of five serum antim\u00fcllerian hormone assays for the diagnosis of polycystic ovary syndrome","volume":"105","author":"Pigny","year":"2016","journal-title":"Fertil. Steril."},{"key":"10.1016\/j.bioelechem.2024.108681_b0080","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1016\/j.rbmo.2015.06.015","article-title":"Assessing ovarian response: antral follicle count versus anti-m\u00fcllerian hormone","volume":"31","author":"Fleming","year":"2015","journal-title":"Reprod. Biomed. Online"},{"key":"10.1016\/j.bioelechem.2024.108681_b0085","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1016\/j.cca.2017.06.009","article-title":"New biomarkers for diagnosis and management of polycystic ovary syndrome","volume":"471","author":"Karakas","year":"2017","journal-title":"Clin. Chim. Acta"},{"key":"10.1016\/j.bioelechem.2024.108681_b0090","doi-asserted-by":"crossref","first-page":"6423","DOI":"10.3390\/s130506423","article-title":"Biosensors in clinical practice: focus on oncohematology","volume":"13","author":"Fracchiolla","year":"2013","journal-title":"Sensors"},{"key":"10.1016\/j.bioelechem.2024.108681_b0095","article-title":"An insight into the state of nanotechnology-based electrochemical biosensors for PCOS detection: mini review","volume":"115412","author":"Chauhan","year":"2023","journal-title":"Anal. Biochem."},{"key":"10.1016\/j.bioelechem.2024.108681_b0100","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1038\/s44222-023-00032-w","article-title":"Device integration of electrochemical biosensors","volume":"1","author":"Wu","year":"2023","journal-title":"Nat. Rev. Bioeng."},{"key":"10.1016\/j.bioelechem.2024.108681_b0105","doi-asserted-by":"crossref","DOI":"10.1016\/j.bioelechem.2022.108155","article-title":"Screen-printed carbon electrode modified with de-bundled single-walled carbon nanotubes for voltammetric determination of norepinephrine in ex vivo rat tissue","volume":"146","author":"Rajarathinam","year":"2022","journal-title":"Bioelectrochemistry"},{"key":"10.1016\/j.bioelechem.2024.108681_b0110","doi-asserted-by":"crossref","first-page":"894","DOI":"10.1016\/j.talanta.2016.08.084","article-title":"Recent trends in electrochemical sensors for multianalyte detection\u2013a review","volume":"161","author":"Jadon","year":"2016","journal-title":"Talanta"},{"key":"10.1016\/j.bioelechem.2024.108681_b0115","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/j.bios.2017.12.031","article-title":"Electrochemical sensor and biosensor platforms based on advanced nanomaterials for biological and biomedical applications","volume":"103","author":"Maduraiveeran","year":"2018","journal-title":"Biosens. Bioelectron."},{"key":"10.1016\/j.bioelechem.2024.108681_b0120","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1016\/j.snb.2018.10.131","article-title":"Electrochemical functionalization of polypyrrole nanowires for the development of ultrasensitive biosensors for detecting microRNA","volume":"281","author":"Wang","year":"2019","journal-title":"Sensors Actuators B Chem."},{"key":"10.1016\/j.bioelechem.2024.108681_b0125","doi-asserted-by":"crossref","first-page":"439","DOI":"10.3390\/bios11110439","article-title":"Robust nanozyme-enzyme nanosheets-based lactate biosensor for diagnosing bacterial infection in olive flounder (Paralichthys olivaceus)","volume":"11","author":"Rajarathinam","year":"2021","journal-title":"Biosensors"},{"key":"10.1016\/j.bioelechem.2024.108681_b0130","doi-asserted-by":"crossref","DOI":"10.1016\/j.aca.2021.338749","article-title":"Polymer-dispersed reduced graphene oxide nanosheets and prussian blue modified biosensor for amperometric detection of sarcosine","volume":"1175","author":"Rajarathinam","year":"2021","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.bioelechem.2024.108681_b0135","doi-asserted-by":"crossref","first-page":"7911","DOI":"10.20964\/2017.08.40","article-title":"A label-free electrochemical immunosensor for anti-mullerian hormone detection on graphene-au nanocomposite","volume":"12","author":"Li","year":"2017","journal-title":"Int. J. Electrochem. Sci"},{"key":"10.1016\/j.bioelechem.2024.108681_b0140","doi-asserted-by":"crossref","first-page":"103","DOI":"10.3390\/chemosensors11020103","article-title":"Nanocomposite-based electrochemical sensors for Neurotransmitters detection in neurodegenerative diseases","volume":"11","author":"Rajarathinam","year":"2023","journal-title":"Chemosensors"},{"key":"10.1016\/j.bioelechem.2024.108681_b0145","doi-asserted-by":"crossref","DOI":"10.1016\/j.talanta.2020.121561","article-title":"Label-free anti-m\u00fcllerian hormone sensor based on polyaniline micellar modified electrode","volume":"222","author":"Yukird","year":"2021","journal-title":"Talanta"},{"key":"10.1016\/j.bioelechem.2024.108681_b0150","doi-asserted-by":"crossref","first-page":"1644","DOI":"10.1039\/C7AN02050C","article-title":"A novel reduced graphene oxide\/molybdenum disulfide\/polyaniline nanocomposite-based electrochemical aptasensor for detection of aflatoxin B 1","volume":"143","author":"Geleta","year":"2018","journal-title":"Analyst"},{"key":"10.1016\/j.bioelechem.2024.108681_b0155","doi-asserted-by":"crossref","first-page":"8264","DOI":"10.1039\/C5CP06830D","article-title":"Conducting polymer based electrochemical biosensors","volume":"18","author":"Aydemir","year":"2016","journal-title":"Phys. Chem. Chem. Phys."},{"key":"10.1016\/j.bioelechem.2024.108681_b0160","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1038\/ncomms1067","article-title":"Reduced graphene oxide by chemical graphitization","volume":"1","author":"Moon","year":"2010","journal-title":"Nat. Commun."},{"key":"10.1016\/j.bioelechem.2024.108681_b0165","doi-asserted-by":"crossref","first-page":"1592","DOI":"10.1021\/acsnano.7b08161","article-title":"Three-dimensional network architecture with hybrid nanocarbon composites supporting few-layer MoS2 for lithium and sodium storage","volume":"12","author":"Hu","year":"2018","journal-title":"ACS Nano"},{"key":"10.1016\/j.bioelechem.2024.108681_b0170","doi-asserted-by":"crossref","first-page":"6420","DOI":"10.1039\/C5NR00585J","article-title":"Carbon nanomaterial-based electrochemical biosensors: an overview","volume":"7","author":"Wang","year":"2015","journal-title":"Nanoscale"},{"key":"10.1016\/j.bioelechem.2024.108681_b0175","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.jelechem.2017.04.018","article-title":"Electrochemical determination of dopamine and acetaminophen using activated graphene-nafion modified glassy carbon electrode","volume":"794","author":"Kim","year":"2017","journal-title":"J. Electroanal. Chem."},{"key":"10.1016\/j.bioelechem.2024.108681_b0180","doi-asserted-by":"crossref","first-page":"2997","DOI":"10.1039\/C8RA09511F","article-title":"Electrochemical sensor based on a three dimensional nanostructured MoS 2 nanosphere-PANI\/reduced graphene oxide composite for simultaneous detection of ascorbic acid, dopamine, and uric acid","volume":"9","author":"Li","year":"2019","journal-title":"RSC Adv."},{"key":"10.1016\/j.bioelechem.2024.108681_b0185","doi-asserted-by":"crossref","first-page":"2922","DOI":"10.1007\/s12035-018-1231-5","article-title":"Biliverdin reductase-a mediates the beneficial effects of intranasal insulin in Alzheimer disease","volume":"56","author":"Barone","year":"2019","journal-title":"Mol. Neurobiol."},{"key":"10.1016\/j.bioelechem.2024.108681_b0190","doi-asserted-by":"crossref","first-page":"1228","DOI":"10.1039\/b801743c","article-title":"Covalent immobilization of antibodies on electrochemically functionalized carbon surfaces","volume":"32","author":"Dauphas","year":"2008","journal-title":"New J. Chem."},{"key":"10.1016\/j.bioelechem.2024.108681_b0195","doi-asserted-by":"crossref","first-page":"8778","DOI":"10.1039\/C8RA09577A","article-title":"A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors","volume":"9","author":"Krishnan","year":"2019","journal-title":"RSC Adv."},{"key":"10.1016\/j.bioelechem.2024.108681_b0200","doi-asserted-by":"crossref","first-page":"1934","DOI":"10.1007\/s11814-013-0117-5","article-title":"A comparative study on antibody immobilization strategies onto solid surface","volume":"30","author":"Lee","year":"2013","journal-title":"Korean J. Chem. Eng."},{"key":"10.1016\/j.bioelechem.2024.108681_b0205","article-title":"Ultrahigh sensitive graphene oxide\/conducting polymer composite based biosensor for cholesterol and bilirubin detection","volume":"13","author":"Kumar","year":"2023","journal-title":"Biosens. Bioelectron. X"},{"key":"10.1016\/j.bioelechem.2024.108681_b0210","doi-asserted-by":"crossref","first-page":"12797","DOI":"10.1038\/s41598-021-92099-x","article-title":"Electro-oxidation of formoterol fumarate on the surface of novel poly (thiazole yellow-G) layered multi-walled carbon nanotube paste electrode","volume":"11","author":"Hareesha","year":"2021","journal-title":"Sci. Rep."},{"key":"10.1016\/j.bioelechem.2024.108681_b0215","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1016\/S1452-3981(23)15315-6","article-title":"Sensitive voltammetric determination of dopamine at salicylic acid and TX-100, SDS, CTAB modified carbon paste electrode","volume":"5","author":"Manjunatha","year":"2010","journal-title":"Int. J. Electrochem. Sci."},{"key":"10.1016\/j.bioelechem.2024.108681_b0220","doi-asserted-by":"crossref","first-page":"662","DOI":"10.1016\/S1452-3981(23)15172-8","article-title":"Electrochemical studies of dopamine at eperisone and cetyl trimethyl ammonium bromide surfactant modified carbon paste electrode: a cyclic voltammetric study","volume":"4","author":"Manjunatha","year":"2009","journal-title":"Int. J. Electrochem. Sci."},{"key":"10.1016\/j.bioelechem.2024.108681_b0225","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.bios.2011.09.038","article-title":"Electrochemical biosensor based on graphene oxide\u2013Au nanoclusters composites for l-cysteine analysis","volume":"31","author":"Ge","year":"2012","journal-title":"Biosens. Bioelectron."},{"key":"10.1016\/j.bioelechem.2024.108681_b0230","doi-asserted-by":"crossref","unstructured":"S.R. 6 (2016) 34587. Kim, Hyeong-U[1] H.-U. Kim, H.Y. Kim, A. Kulkarni, C. Ahn, Y. Jin, Y. Kim, K.-N. Lee, M.-H. Lee, T. Kim, A sensitive electrochemical sensor for in vitro detection of parathyroid hormone based on a MoS2-graphene composite, H.Y. Kim, A. Kulkarni, C. Ahn, Y. Jin, Y. Kim, K.-N. Lee, M.-H. Lee, T. Kim, A sensitive electrochemical sensor for in vitro detection of parathyroid hormone based on a MoS2-graphene composite, Sci. Rep. 6 (2016) 34587.","DOI":"10.1038\/srep34587"},{"key":"10.1016\/j.bioelechem.2024.108681_b0235","article-title":"Voltammetric analysis of antihistamine drug cetirizine and paracetamol at poly (L-leucine) layered carbon nanotube paste electrode","volume":"24","author":"Pushpanjali","year":"2021","journal-title":"Surf. Interfaces"},{"key":"10.1016\/j.bioelechem.2024.108681_b0240","doi-asserted-by":"crossref","first-page":"750","DOI":"10.1134\/S0020441220050139","article-title":"Optimized voltammetric experiment for the determination of phloroglucinol at surfactant modified carbon nanotube paste electrode, instruments","volume":"63","author":"Tigari","year":"2020","journal-title":"Exp. Tech."},{"key":"10.1016\/j.bioelechem.2024.108681_b0245","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1016\/j.bios.2017.11.002","article-title":"Label-free electrochemical DNA biosensor for guanine and adenine by ds-DNA\/poly (L-cysteine)\/Fe3O4 nanoparticles-graphene oxide nanocomposite modified electrode","volume":"102","author":"Arvand","year":"2018","journal-title":"Biosens. Bioelectron."},{"key":"10.1016\/j.bioelechem.2024.108681_b0250","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1016\/j.apsusc.2017.01.024","article-title":"Development of glucose biosensors based on plasma polymerization-assisted nanocomposites of polyaniline, tin oxide, and three-dimensional reduced graphene oxide","volume":"401","author":"Wu","year":"2017","journal-title":"Appl. Surf. Sci."},{"key":"10.1016\/j.bioelechem.2024.108681_b0255","doi-asserted-by":"crossref","first-page":"1180","DOI":"10.3390\/nano9081180","article-title":"Structural characterization of graphene oxide: Surface functional groups and fractionated oxidative debris","volume":"9","author":"Aliyev","year":"2019","journal-title":"Nanomaterials"},{"key":"10.1016\/j.bioelechem.2024.108681_b0260","doi-asserted-by":"crossref","first-page":"900","DOI":"10.1039\/B917752C","article-title":"Noncovalent DNA decorations of graphene oxide and reduced graphene oxide toward water-soluble metal\u2013carbon hybrid nanostructures via self-assembly","volume":"20","author":"Liu","year":"2010","journal-title":"J. Mater. Chem."},{"key":"10.1016\/j.bioelechem.2024.108681_b0265","doi-asserted-by":"crossref","first-page":"1332","DOI":"10.1039\/C3TA13688D","article-title":"Iodide-mediated room temperature reduction of graphene oxide: a rapid chemical route for the synthesis of a bifunctional electrocatalyst","volume":"2","author":"Das","year":"2014","journal-title":"J. Mater. Chem. A"},{"key":"10.1016\/j.bioelechem.2024.108681_b0270","first-page":"74","article-title":"Controlled synthesis, characterization and reduction of graphene oxide: a convenient method for large scale production","volume":"4","author":"Emiru","year":"2017","journal-title":"Egypt. J. Basic Appl. Sci."},{"key":"10.1016\/j.bioelechem.2024.108681_b0275","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1016\/j.pnsc.2015.10.004","article-title":"Influence of graphene microstructures on electrochemical performance for supercapacitors","volume":"25","author":"Gong","year":"2015","journal-title":"Prog. Nat. Sci. Mater. Int."},{"key":"10.1016\/j.bioelechem.2024.108681_b0280","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1556-276X-6-551","article-title":"Preparation of pt ag alloy nanoisland\/graphene hybrid composites and its high stability and catalytic activity in methanol electro-oxidation","volume":"6","author":"Feng","year":"2011","journal-title":"Nanoscale Res. Lett."},{"key":"10.1016\/j.bioelechem.2024.108681_b0285","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.carbon.2012.10.013","article-title":"The chemical and structural analysis of graphene oxide with different degrees of oxidation","volume":"53","author":"Krishnamoorthy","year":"2013","journal-title":"Carbon n. y."},{"key":"10.1016\/j.bioelechem.2024.108681_b0290","doi-asserted-by":"crossref","DOI":"10.1016\/j.ijbiomac.2023.127903","article-title":"Glutamate oxidase sheets-prussian blue grafted amperometric biosensor for the real time monitoring of glutamate release from primary cortical neurons","volume":"254","author":"Rajarathinam","year":"2024","journal-title":"Int. J. Biol. Macromol."},{"key":"10.1016\/j.bioelechem.2024.108681_b0295","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1039\/D1LC00910A","article-title":"A sample-to-answer electrochemical biosensor system for biomarker detection","volume":"22","author":"Kikkeri","year":"2022","journal-title":"Lab Chip"},{"key":"10.1016\/j.bioelechem.2024.108681_b0300","doi-asserted-by":"crossref","first-page":"e0266769","DOI":"10.1371\/journal.pone.0266769","article-title":"A low-cost, open-source centrifuge adaptor for separating large volume clinical blood samples","volume":"17","author":"Haque","year":"2022","journal-title":"PLoS One"}],"container-title":["Bioelectrochemistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1567539424000434?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1567539424000434?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,5,21]],"date-time":"2024-05-21T07:23:24Z","timestamp":1716276204000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1567539424000434"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8]]},"references-count":60,"alternative-id":["S1567539424000434"],"URL":"https:\/\/doi.org\/10.1016\/j.bioelechem.2024.108681","relation":{},"ISSN":["1567-5394"],"issn-type":[{"value":"1567-5394","type":"print"}],"subject":[],"published":{"date-parts":[[2024,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Label-Free detection of Poly-Cystic Ovarian Syndrome using a highly conductive 2-D rGO\/MoS2\/PANI nanocomposite based immunosensor","name":"articletitle","label":"Article Title"},{"value":"Bioelectrochemistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.bioelechem.2024.108681","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}],"article-number":"108681"}}