{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T07:03:22Z","timestamp":1789196602478,"version":"build-2803163510"},"reference-count":23,"publisher":"Elsevier BV","issue":"28","license":[{"start":{"date-parts":[[2004,12,1]],"date-time":"2004-12-01T00:00:00Z","timestamp":1101859200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2004,12,1]],"date-time":"2004-12-01T00:00:00Z","timestamp":1101859200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Biomaterials"],"published-print":{"date-parts":[[2004,12]]},"DOI":"10.1016\/j.biomaterials.2004.01.064","type":"journal-article","created":{"date-parts":[[2004,3,9]],"date-time":"2004-03-09T08:52:41Z","timestamp":1078822361000},"page":"5913-5920","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":136,"title":["Comparison of metal concentrations in rat tibia tissues with various metallic implants"],"prefix":"10.1016","volume":"25","author":[{"given":"Yoshimitsu","family":"Okazaki","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emiko","family":"Gotoh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takeshi","family":"Manabe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kihei","family":"Kobayashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.biomaterials.2004.01.064_BIB1","doi-asserted-by":"crossref","first-page":"1475","DOI":"10.2106\/00004623-199173100-00005","article-title":"Release and excretion of metal in patients who have a total hip-replacement component made of titanium-base alloy","volume":"73-A","author":"Jacobs","year":"1991","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB2","doi-asserted-by":"crossref","first-page":"1447","DOI":"10.2106\/00004623-199810000-00006","article-title":"Metal release in patients who have had a primary total hip arthroplasty","volume":"80-A","author":"Jacobs","year":"1998","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB3","doi-asserted-by":"crossref","first-page":"347","DOI":"10.2106\/00004623-198870030-00005","article-title":"Metallic wear in failed titanium-alloy total hip replacements","volume":"70-A","author":"Agins","year":"1988","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB4","first-page":"239","article-title":"Nickel-, chrom- and cobalt-concentration in human tissue and body fluids of hip prosthesis patients","volume":"6","author":"Hennig","year":"1992","journal-title":"J Trace Elem Electrolytes Health Dis"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB5","doi-asserted-by":"crossref","first-page":"574","DOI":"10.3109\/17453678308992891","article-title":"Metal determination in organic fluids of patients with stainless steel hip arthroplasty","volume":"54","author":"Pazzaglia","year":"1983","journal-title":"Acta Orthop Scand"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB6","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1002\/jor.1100070302","article-title":"Cobalt, chromium, and nickel concentrations in body fluids of patients with porous-coated knee or hip prostheses","volume":"7","author":"Sunderman","year":"1989","journal-title":"J Orthop Res"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB7","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1097\/00003086-199901000-00021","article-title":"Metal release and excretion from cementless titanium alloy total knee replacements","volume":"358","author":"Jacobs","year":"1999","journal-title":"Clin Orthop Related Res"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB8","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1097\/00003086-199110000-00004","article-title":"Implications of metallic corrosion in total knee arthroplasty","volume":"271","author":"Wapner","year":"1991","journal-title":"Clin Orthop Related Res"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB9","unstructured":"Okazaki Y, Nishimura E. Comparison of metal release from metallic biomaterials in Vitro. Biomaterials, in press."},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB10","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1002\/(SICI)1097-4636(199604)30:4<523::AID-JBM11>3.0.CO;2-I","article-title":"Light and electron microscopic studies of bone-titanium interface in the tibiae of young and mature rats","volume":"30","author":"Murai","year":"1996","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB11","doi-asserted-by":"crossref","first-page":"858","DOI":"10.2186\/jjps.37.858","article-title":"A comparative study of bone tissue reaction to Ti implants in the tibiae between mature and young rats","volume":"37","author":"Murai","year":"1993","journal-title":"J Jpn Prosthodont Soc"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB12","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1016\/S0142-9612(00)00221-0","article-title":"Surface analysis of Ti\u201315Zr\u20134Nb\u20134Ta alloy after implantation in rat tibia","volume":"22","author":"Okazaki","year":"2001","journal-title":"Biomaterials"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB13","doi-asserted-by":"crossref","first-page":"344","DOI":"10.2320\/matertrans1989.38.344","article-title":"Effects of Mo and Pd on corrosion resistance of V-free titanium alloys for medical implants","volume":"38","author":"Okazaki","year":"1997","journal-title":"Mater Trans JIM"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB14","doi-asserted-by":"crossref","first-page":"78","DOI":"10.2320\/matertrans1989.38.78","article-title":"Corrosion resistance of implant alloys in pseudo physiological solution and role of alloying elements in passive films","volume":"38","author":"Okazaki","year":"1997","journal-title":"Mater Trans JIM"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB15","series-title":"Medical applications of titanium and its alloys: the material and biological issues, ASTM STP 1272","first-page":"3","article-title":"Titanium alloys as implant materials","author":"Imam","year":"1996"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB16","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1002\/jbm.820260305","article-title":"The mechanisms of passive dissolution of titanium in a model physiological environment","volume":"26","author":"Healy","year":"1992","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB17","series-title":"Medical applications of titanium and its alloys: the material and biological issues, ASTM STP 1272","first-page":"179","article-title":"Passive dissolution of titanium in biological environments","author":"Healy","year":"1996"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB18","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/0142-9612(80)90016-2","article-title":"Metal ion release after total hip replacement","volume":"1","author":"Dobbs","year":"1980","journal-title":"Biomaterials"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB19","first-page":"158","article-title":"Elution and biocompatibility of titanium in the rabbit tissue","volume":"17","author":"Seki","year":"1992","journal-title":"Dent J Iwate Med Univ"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB20","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1002\/(SICI)1097-4636(199606)31:2<227::AID-JBM9>3.0.CO;2-P","article-title":"Local accumulation of titanium released from a titanium implant in the absence of wear","volume":"31","author":"Bianco","year":"1996","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB21","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1016\/S0901-5027(89)80102-X","article-title":"Metal release from plates used in jaw fracture treatment","volume":"18","author":"Moberg","year":"1989","journal-title":"Int J Oral Maxillofac Surg"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB22","first-page":"839","article-title":"Increased blood cobalt and chromium after total hip replacement","volume":"37","author":"Schaffer","year":"1999","journal-title":"Clin Toxicol"},{"key":"10.1016\/j.biomaterials.2004.01.064_BIB23","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1302\/0301-620X.79B2.0790316","article-title":"Elevated serum cobalt with metal-on-metal articulating surfaces","volume":"79-B","author":"Brodner","year":"1997","journal-title":"J Bone Joint Surg"}],"container-title":["Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S014296120400119X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S014296120400119X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T14:40:16Z","timestamp":1758897616000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S014296120400119X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,12]]},"references-count":23,"journal-issue":{"issue":"28","published-print":{"date-parts":[[2004,12]]}},"alternative-id":["S014296120400119X"],"URL":"https:\/\/doi.org\/10.1016\/j.biomaterials.2004.01.064","relation":{},"ISSN":["0142-9612"],"issn-type":[{"value":"0142-9612","type":"print"}],"subject":[],"published":{"date-parts":[[2004,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of metal concentrations in rat tibia tissues with various metallic implants","name":"articletitle","label":"Article Title"},{"value":"Biomaterials","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.biomaterials.2004.01.064","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"converted-article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2004 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}