{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T06:52:48Z","timestamp":1791355968341,"version":"4.3.1"},"reference-count":41,"publisher":"Elsevier BV","issue":"9","license":[{"start":{"date-parts":[[2005,3,1]],"date-time":"2005-03-01T00:00:00Z","timestamp":1109635200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2005,3,1]],"date-time":"2005-03-01T00:00:00Z","timestamp":1109635200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Biomaterials"],"published-print":{"date-parts":[[2005,3]]},"DOI":"10.1016\/j.biomaterials.2004.03.038","type":"journal-article","created":{"date-parts":[[2004,5,30]],"date-time":"2004-05-30T16:56:15Z","timestamp":1085936175000},"page":"1019-1026","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":112,"title":["Screening for symptomatic metal sensitivity: a prospective study of 92 patients undergoing total knee arthroplasty"],"prefix":"10.1016","volume":"26","author":[{"given":"Yasuo","family":"Niki","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideo","family":"Matsumoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshiro","family":"Otani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taku","family":"Yatabe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Makoto","family":"Kondo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fumihiro","family":"Yoshimine","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshiaki","family":"Toyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.biomaterials.2004.03.038_BIB1","series-title":"Biological material and medchanical considerations of joint replacement","first-page":"87","article-title":"Particle disease due to wear of ultrahigh molecular weight polyethylene","author":"Willert","year":"1993"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB2","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1002\/jor.1100130520","article-title":"Human monocyte response to particulate biomaterials generated in vivo and in vitro","volume":"13","author":"Shanbhag","year":"1995","journal-title":"J Orthop Res"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB3","doi-asserted-by":"crossref","first-page":"825","DOI":"10.2106\/00004623-199306000-00004","article-title":"The difference in toxicity and release of bone-resorbing mediators induced by titanium and cobalt-chromium-alloy wear particles","volume":"75","author":"Haynes","year":"1993","journal-title":"J Bone Jt Surg Am"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB4","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1002\/(SICI)1097-4636(19980905)41:3<468::AID-JBM17>3.0.CO;2-E","article-title":"The effects of cobalt chromium upon macrophages","volume":"41","author":"Horowitz","year":"1998","journal-title":"J Biomed Meter Res"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB5","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1054\/arth.2000.6622","article-title":"The effect of particle phagocytosis and metallic wear particles on osteoclast formation and bone resorption in vitro","volume":"15","author":"Neale","year":"2000","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB6","doi-asserted-by":"crossref","first-page":"2233","DOI":"10.1016\/0142-9612(96)00072-5","article-title":"Titanium, chromium and cobalt ions modulate the release of bone-associated cytokines by human monocytes\/macrophages in vitro","volume":"17","author":"Wang","year":"1996","journal-title":"Biomaterials"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB7","doi-asserted-by":"crossref","first-page":"1447","DOI":"10.1016\/S0142-9612(02)00531-8","article-title":"Metal ions induce bone-resorbing cytokine production through the redox pathway in synoviocytes and bone marrow macrophage","volume":"24","author":"Niki","year":"2003","journal-title":"Biomaterials"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB8","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.1016\/S0142-9612(99)00004-6","article-title":"Cytokine release in mononuclear cells of patients with Co\u2013Cr hip prosthesis","volume":"20","author":"Granchi","year":"1999","journal-title":"Biomaterials"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB9","doi-asserted-by":"crossref","first-page":"2459","DOI":"10.4049\/jimmunol.155.5.2459","article-title":"Activation of nuclear factor-\u03baB and gene expression in human endothelial cells by the common haptens nickel and cobalt","volume":"155","author":"Goebeler","year":"1995","journal-title":"J Immunol"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB10","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1111\/j.1600-0625.1993.tb00010.x","article-title":"Mechanisms in allergic contact dermatitis","volume":"2","author":"Becker","year":"1993","journal-title":"Exp Dermatol"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB11","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1111\/1523-1747.ep12372149","article-title":"The molecular basis of metal recognition by T cells","volume":"102","author":"Sinigaglia","year":"1994","journal-title":"J Invest Dermatol"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB12","doi-asserted-by":"crossref","first-page":"57","DOI":"10.3109\/17453678008990769","article-title":"Metal sensitivity in patients with metal-to-plastic total hip arthroplasties","volume":"51","author":"Carlsson","year":"1980","journal-title":"Acta Orthop Scand"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB13","doi-asserted-by":"crossref","first-page":"862","DOI":"10.2106\/00004623-197759070-00004","article-title":"Metal sensitivity before and after total hip arthroplasty","volume":"59","author":"Deutman","year":"1977","journal-title":"J Bone Jt Surg Am"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB14","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1302\/0301-620X.62B4.7430234","article-title":"Metal sensitivity in patients undergoing hip replacement. A prospective study","volume":"62","author":"Rooker","year":"1980","journal-title":"J Bone Jt Surg Br"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB15","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1111\/1523-1747.ep12724164","article-title":"In vitro studies of contact hypersensitivity. Lymphocyte transformation in nickel sensitivity","volume":"60","author":"Millikan","year":"1973","journal-title":"J Invest Dermatol"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB16","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1111\/j.1365-2133.1990.tb08276.x","article-title":"The discrimination between nickel-sensitive and non-nickel-sensitive subjects by an in vitro lymphocyte stimulation test","volume":"122","author":"Everness","year":"1990","journal-title":"Br J Dermatol"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB17","first-page":"475","article-title":"The lymphocytic transformation test (LTT) in the evaluation of intolerance in prosthetic implants","volume":"11","author":"Carando","year":"1985","journal-title":"Ital J Orthop Traumatol"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB18","doi-asserted-by":"crossref","first-page":"1301","DOI":"10.1016\/S0142-9612(99)00235-5","article-title":"Hypersensitivity to metallic biomaterials","volume":"21","author":"Hallab","year":"2000","journal-title":"Biomaterials"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB19","doi-asserted-by":"crossref","first-page":"428","DOI":"10.2106\/00004623-200103000-00017","article-title":"Current concept review; metal sensitivity in patients with orthopaedic implants","volume":"83","author":"Hallab","year":"2001","journal-title":"J Bone Jt Surg Am"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB20","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1111\/j.1600-0536.1993.tb03318.x","article-title":"Nickel, cobalt and chromium in consumer products","volume":"28","author":"Basketter","year":"1993","journal-title":"Contact Dermatitis"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB21","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1111\/j.1600-0536.1993.tb03427.x","article-title":"Nickel sensitivity and the implantation of orthopaedic prosthesis","volume":"28","author":"Gawkrodger","year":"1993","journal-title":"Contact Dermatitis"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB22","first-page":"286","article-title":"Metal specific responses dominate in vitro hypersensitivity reactions in patients with total joint arthroplasy","volume":"28","author":"Hallab","year":"2003","journal-title":"Orthop Trans"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB23","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1097\/00003086-199605000-00009","article-title":"Immune response to synthetic materials. Sensitization of patients receiving orthopaedic implants","volume":"326","author":"Merritt","year":"1996","journal-title":"Clin Orthop"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB24","unstructured":"Niki Y, Matsumoto H, Otani T, Suda Y, Toyoda T, Yoshimine F, Toyama Y. Clinical and immunological evaluation of patients with metal hypersensitivity following total knee arthroplasty. Is metal hypersensitivity a cause of prosthetic loosening? In: Proceeding of 70th Annual Meeting of the American Academy of Orthopaedic Surgeons 2003. p. 409\u201310."},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB25","first-page":"1408","article-title":"Dermatitis due to orthopaedic implants. A review of the literature and report of three cases","volume":"9","author":"Rostoker","year":"1987","journal-title":"J Bone Jt Surg Am"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB26","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1111\/j.1600-0536.1992.tb03259.x","article-title":"Generalized eczema from vitallium osteosynthesis material","volume":"27","author":"Merle","year":"1992","journal-title":"Contact Dermatitis"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB27","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1111\/j.1600-0536.1994.tb02023.x","article-title":"Nickel release from metals, and a case of allergic contact dermatitis from stainless steel","volume":"31","author":"Kanerva","year":"1994","journal-title":"Contact Dermatitis"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB28","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1111\/j.1600-0536.1994.tb00590.x","article-title":"Systemic contact dermatitis from dental crowns","volume":"30","author":"Guimaraens","year":"1994","journal-title":"Contact Dermatitis"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB29","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1111\/j.1600-0536.1992.tb00867.x","article-title":"Pacemaker dermatitis","volume":"26","author":"Buchet","year":"1992","journal-title":"Contact Dermatitis"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB30","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1111\/j.1600-0536.1984.tb00101.x","article-title":"Oral exposure to a nickel-containing dental alloy of persons with hypersensitive skin reactions to nickel","volume":"10","author":"Spiechowicz","year":"1984","journal-title":"Contact Dermatitis"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB31","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1111\/j.1600-0536.1994.tb00568.x","article-title":"Contact dermatitis and adverse oral mucus membrane reactions related to the use of dental prostheses","volume":"30","author":"Vilaplana","year":"1994","journal-title":"Contact Dermatitis"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB32","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1002\/1097-4636(200009)53:5<480::AID-JBM6>3.0.CO;2-B","article-title":"A triple assay technique for the evaluation of metal-induced, delayed-type hypersensitivity responses in patients with or receiving total joint arthroplasty","volume":"53","author":"Hallab","year":"2000","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB33","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1016\/0142-9612(84)90024-3","article-title":"In vivo production of hexavalent chromium","volume":"5","author":"Rogers","year":"1984","journal-title":"Biomaterials"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB34","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1002\/(SICI)1097-4636(199605)31:1<71::AID-JBM9>3.0.CO;2-N","article-title":"Production of monoclonal antibodies to study corrosion products of CO-CR biomaterials","volume":"31","author":"Yang","year":"1996","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB35","first-page":"108","article-title":"Review article Series V. The skin as target for IgE-mediated allergic reactions. Immunologic mechanisms in hypersensitivity reactions to metal ions","volume":"55","author":"Budinger","year":"2000","journal-title":"Allergy"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB36","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1016\/S0167-4889(96)00150-4","article-title":"Redox regulation of the mitogen-activated protein kinase pathway during lymphocyte activation","volume":"1355","author":"Goldstone","year":"1997","journal-title":"Biochim Biophys Acta"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB37","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1016\/0002-9610(80)90323-2","article-title":"Metal allergy and the surgical patient","volume":"139","author":"Mayer","year":"1980","journal-title":"Am J Surg"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB38","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1136\/ard.39.5.476","article-title":"Metal sensitivity causing loosened joint prostheses","volume":"39","author":"Christiansen","year":"1980","journal-title":"Ann Rheum Dis"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB39","first-page":"2","article-title":"Histopathological changes around metal\/metal joints indicate delayed type hypersensitivity. Preliminary results of 14 cases","volume":"9","author":"Willert","year":"2000","journal-title":"Osteologie"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB40","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1097\/00003086-200001000-00017","article-title":"Effect of low friction ion treated femoral heads on polyethylene wear rates","volume":"370","author":"Maruyama","year":"2000","journal-title":"Clin Orthop"},{"key":"10.1016\/j.biomaterials.2004.03.038_BIB41","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1002\/jbm.820210308","article-title":"Ion implantation of surgical Ti-6A1-4V for improved resistance to wear-accelerated corrosion","volume":"21","author":"Buchanan","year":"1987","journal-title":"J Biomed Mater Res"}],"container-title":["Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0142961204002960?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0142961204002960?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T14:41:39Z","timestamp":1758897699000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0142961204002960"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,3]]},"references-count":41,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2005,3]]}},"alternative-id":["S0142961204002960"],"URL":"https:\/\/doi.org\/10.1016\/j.biomaterials.2004.03.038","relation":{},"ISSN":["0142-9612"],"issn-type":[{"value":"0142-9612","type":"print"}],"subject":[],"published":{"date-parts":[[2005,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Screening for symptomatic metal sensitivity: a prospective study of 92 patients undergoing total knee arthroplasty","name":"articletitle","label":"Article Title"},{"value":"Biomaterials","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.biomaterials.2004.03.038","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"converted-article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2004 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}