{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,6]],"date-time":"2025-11-06T19:47:14Z","timestamp":1762458434144,"version":"3.44.0"},"reference-count":27,"publisher":"Elsevier BV","issue":"30","license":[{"start":{"date-parts":[[2005,10,1]],"date-time":"2005-10-01T00:00:00Z","timestamp":1128124800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2005,10,1]],"date-time":"2005-10-01T00:00:00Z","timestamp":1128124800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Biomaterials"],"published-print":{"date-parts":[[2005,10]]},"DOI":"10.1016\/j.biomaterials.2005.03.022","type":"journal-article","created":{"date-parts":[[2005,6,14]],"date-time":"2005-06-14T07:25:33Z","timestamp":1118733933000},"page":"6034-6040","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":44,"title":["Polyethylene wear particle generation in vivo in an alumina medial pivot total knee prosthesis"],"prefix":"10.1016","volume":"26","author":[{"given":"Yukihide","family":"Minoda","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akio","family":"Kobayashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroyoshi","family":"Iwaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masatsugu","family":"Miyaguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshinori","family":"Kadoya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hirotsugu","family":"Ohashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kunio","family":"Takaoka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.biomaterials.2005.03.022_bib1","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1002\/jbm.820110202","article-title":"Reactions of the articular capsule to wear products of artificial joint prostheses","volume":"11","author":"Willert","year":"1977","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib2","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1002\/jor.1100140318","article-title":"Bone formation and bone resorption in failed total joint arthroplasties: histomorphometric analysis with histochemical and immunohistochemical technique","volume":"14","author":"Kadoya","year":"1996","journal-title":"J Orthop Res"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib3","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1097\/00003086-199707000-00016","article-title":"Wear particulate species and bone loss in failed total joint arthroplasties","volume":"340","author":"Kadoya","year":"1997","journal-title":"Clin Orthop"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib4","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1002\/1097-4636(200101)54:1<12::AID-JBM2>3.0.CO;2-X","article-title":"In situ complement activation by polyethylene wear debris","volume":"54","author":"DeHeer","year":"2001","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib5","first-page":"9","article-title":"Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prosthesis","volume":"74B","author":"Engh","year":"1988","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib6","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1002\/(SICI)1097-4636(199824)43:4<473::AID-JBM16>3.0.CO;2-9","article-title":"Pathologic supracondylar fracture due to osteolytic pseudotumor of knee following cementless total knee replacement","volume":"43","author":"Benevenia","year":"1998","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib7","doi-asserted-by":"crossref","first-page":"890","DOI":"10.1016\/S0883-5403(98)90195-4","article-title":"Assessing activity in joint replacement patients","volume":"13","author":"Zahiri","year":"1998","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib8","unstructured":"Insall JN, Aglietti P, Baldini A, Easley ME. Meniscal-bearing knee replacement. In: Insall JN, Scott WN, editors. Surgery of the Knee, vol. 2, 3rd ed. Philadelphia: Churchill Livingstone; 2001. p. 1717\u201338."},{"key":"10.1016\/j.biomaterials.2005.03.022_bib9","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1097\/01.blo.0000063122.39522.c2","article-title":"Polyethylene wear particles in synovial fluid after total knee arthroplasty","volume":"410","author":"Minoda","year":"2003","journal-title":"Clin Orthop"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib10","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1097\/00003086-199209000-00012","article-title":"Alumina versus polyethylene in total knee arthroplasty","volume":"282","author":"Oonishi","year":"1992","journal-title":"Clin Orthop"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib11","doi-asserted-by":"crossref","first-page":"1626","DOI":"10.2106\/00004623-200011000-00017","article-title":"The Bisurface total knee replacement: a unique design for flexion. Four-to-nine-year follow-up study","volume":"82A","author":"Akagi","year":"2000","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib12","first-page":"801","article-title":"Comparison of the wear propeties of polyethylene plate in total knee prostheses using different femoral component materials","volume":"15","author":"Ueno","year":"2002","journal-title":"Biocermics"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib13","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/jbm.b.30005","article-title":"Characteristics of polyethylene wear particles isolated from synovial fluid after mobile-bearing and posterior-stabilized total knee arthroplasties","volume":"71B","author":"Minoda","year":"2004","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib14","doi-asserted-by":"crossref","first-page":"228","DOI":"10.2106\/00004623-198466020-00010","article-title":"Treatment of primary osteoarthritis of the hip. A comparison of total joint and surface replacement arthroplasty","volume":"66A","author":"Amstutz","year":"1984","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib15","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1002\/jbm.820290118","article-title":"Isolation of predominantly submicron-sized UHMWPE wear particles from periprosthetic tissues","volume":"29","author":"Campbell","year":"1995","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib16","doi-asserted-by":"crossref","first-page":"844","DOI":"10.1302\/0301-620X.79B5.0790844","article-title":"Number of polyethylene particles and osteolysis in total joint replacements. A quantitative study using a tissue-digestion method","volume":"79B","author":"Kobayashi","year":"1997","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib17","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1097\/01.blo.0000063565.90853.a4","article-title":"Fluoroscopic analyses of cruciate-retaining and medial pivot knee implants","volume":"410","author":"Schmidt","year":"2003","journal-title":"Clin Orthop"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib18","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1002\/jbm.820100407","article-title":"Biomechanically induced tissue reactions after Al2O3-ceramic hip joint replacement. Experimental and early clinical results","volume":"10","author":"Griss","year":"1976","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib19","doi-asserted-by":"crossref","first-page":"1688","DOI":"10.2106\/00004623-200111000-00011","article-title":"Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twenty-one-year results","volume":"83A","author":"Urban","year":"2001","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib20","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1302\/0301-620X.85B4.13397","article-title":"Zirconia and alumina ceramics in comparison with stainless-steel heads. Polyethylene wear after a minimum ten-year follow-up","volume":"85B","author":"Hernigou","year":"2003","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib21","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1302\/0301-620X.85B5.13923","article-title":"Effect of alumina femoral heads on polyethylene wear in cemented total hip arthroplasty. Old versus current alumina","volume":"85B","author":"Tanaka","year":"2003","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib22","first-page":"157","article-title":"Cementless alumina ceramic total knee prostheses","volume":"1","author":"Oonishi","year":"1981","journal-title":"Orthop Ceramic Implants"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib23","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1002\/1097-4636(200011)52:2<296::AID-JBM8>3.0.CO;2-9","article-title":"Evaluation of the response of primary human peripheral blood mononuclear phagocytes to challenge with in vitro generated clinically relevant UHMWPE particles of known size and dose","volume":"52","author":"Matthews","year":"2000","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib24","doi-asserted-by":"crossref","first-page":"3535","DOI":"10.1016\/S0142-9612(02)00032-7","article-title":"Diverse cellular and apoptotic responses to variant shapes of UHMWPE particles in a murine model of inflammation","volume":"23","author":"Yang","year":"2002","journal-title":"Biomaterials"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib25","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1016\/S0142-9612(96)00207-4","article-title":"Influence of gamma-irradiation sterilization and temperature on the fracture toughness of ultra-high-molecular-weight polyethylene","volume":"18","author":"Pascaud","year":"1997","journal-title":"Biomaterials"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib26","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1097\/00003086-199811000-00024","article-title":"The impact of sterilization method on wear in knee arthroplasty","volume":"356","author":"Williams","year":"1998","journal-title":"Clin Orthop"},{"key":"10.1016\/j.biomaterials.2005.03.022_bib27","doi-asserted-by":"crossref","first-page":"54","DOI":"10.2106\/00004623-199801000-00010","article-title":"Quantitative assessment of walking activity after total hip or knee replacement","volume":"80A","author":"Schmalzried","year":"1998","journal-title":"J Bone Joint Surg"}],"container-title":["Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0142961205002577?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0142961205002577?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T14:46:36Z","timestamp":1758897996000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0142961205002577"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,10]]},"references-count":27,"journal-issue":{"issue":"30","published-print":{"date-parts":[[2005,10]]}},"alternative-id":["S0142961205002577"],"URL":"https:\/\/doi.org\/10.1016\/j.biomaterials.2005.03.022","relation":{},"ISSN":["0142-9612"],"issn-type":[{"type":"print","value":"0142-9612"}],"subject":[],"published":{"date-parts":[[2005,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Polyethylene wear particle generation in vivo in an alumina medial pivot total knee prosthesis","name":"articletitle","label":"Article Title"},{"value":"Biomaterials","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.biomaterials.2005.03.022","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2005 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}