{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,20]],"date-time":"2026-09-20T05:33:39Z","timestamp":1789882419502,"version":"4.0.1"},"reference-count":45,"publisher":"Elsevier BV","issue":"12","license":[{"start":{"date-parts":[[2011,4,1]],"date-time":"2011-04-01T00:00:00Z","timestamp":1301616000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2011,4,1]],"date-time":"2011-04-01T00:00:00Z","timestamp":1301616000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Biomaterials"],"published-print":{"date-parts":[[2011,4]]},"DOI":"10.1016\/j.biomaterials.2011.01.047","type":"journal-article","created":{"date-parts":[[2011,2,10]],"date-time":"2011-02-10T06:04:59Z","timestamp":1297317899000},"page":"3158-3165","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":17,"title":["A perfluoropolyether corneal inlay for the correction of refractive error"],"prefix":"10.1016","volume":"32","author":[{"given":"Margaret D.M.","family":"Evans","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruby K.","family":"Prakasam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pravin K.","family":"Vaddavalli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timothy C.","family":"Hughes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Warren","family":"Knower","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John S.","family":"Wilkie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keith M.","family":"McLean","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Graham","family":"Johnson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gail A.","family":"McFarland","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruo Zhong","family":"Xie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deborah F.","family":"Sweeney","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.biomaterials.2011.01.047_bib1","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.clae.2005.10.006","article-title":"Factors influencing patient choice of refractive surgery or contact lenses and choice of centre","volume":"29","author":"Gupta","year":"2006","journal-title":"Cont Lens Anterior Eye"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib2","doi-asserted-by":"crossref","first-page":"1357","DOI":"10.1016\/S0161-6420(98)98012-5","article-title":"Laser in situ keratomileusis versus photorefractive keratectomy: an update on indications and safety","volume":"105","author":"Azar","year":"1998","journal-title":"Ophthalmology"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib3","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1016\/S0886-3350(01)01177-4","article-title":"Comparison of photorefractive keratectomy, astigmatic PRK, laser in situ keratomiluesis, and astigmatic LASIK in the treatment of myopia","volume":"28","author":"Van Gelder","year":"2002","journal-title":"J\u00a0Cataract Refract Surg"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib4","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1016\/S0039-6257(04)00135-3","article-title":"Evolution, techniques, clinical outcomes and pathophysiology of LASEK: Review of the literature","volume":"49","author":"Taneri","year":"2004","journal-title":"Surv Ophthalmol"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib5","doi-asserted-by":"crossref","first-page":"2041","DOI":"10.1016\/j.jcrs.2007.07.026","article-title":"Laser in situ keratomileusis versus surface ablation: visual outcomes and complications","volume":"33","author":"Ghadhfan","year":"2007","journal-title":"J\u00a0Cataract Refract Surg"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib6","doi-asserted-by":"crossref","first-page":"1111","DOI":"10.1016\/j.ophtha.2006.08.052","article-title":"One year clinical results after Epi-LASIK for myopia","volume":"114","author":"Katsanevaki","year":"2007","journal-title":"Ophthalmology"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib7","first-page":"216","article-title":"Design principles of synthetic corneal inlays and onlays","volume":"25","author":"Hughes","year":"2001","journal-title":"Mater Forum"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib8","series-title":"Biomaterials and regenerative medicine in ophthalmology","first-page":"65","article-title":"Synthetic corneal implants","author":"Evans","year":"2010"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib9","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1016\/S0002-9394(14)77762-1","article-title":"Specular microscopy of corneal epithelium after epikeratophakia","volume":"103","author":"Rao","year":"1987","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib10","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/S0002-9394(14)73980-7","article-title":"Clinical and histopathologic changes in the host cornea after epikeratophakia for keratoconus","volume":"114","author":"Rodrigues","year":"1992","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib11","doi-asserted-by":"crossref","first-page":"3311","DOI":"10.1167\/iovs.05-1647","article-title":"Construction of a complete rabbit cornea substitute using a fibrin-agarose scaffold","volume":"47","author":"Alaminos","year":"2006","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"9","key":"10.1016\/j.biomaterials.2011.01.047_bib12","doi-asserted-by":"crossref","first-page":"1147","DOI":"10.1016\/j.biomaterials.2007.11.011","article-title":"Recombinant human collagen for tissue engineered corneal substitutes","volume":"29","author":"Liu","year":"2008","journal-title":"Biomaterials"},{"issue":"2","key":"10.1016\/j.biomaterials.2011.01.047_bib13","first-page":"46","article-title":"A\u00a0biosynthetic alternative to human donor tissue for inducing corneal regeneration: 24-month follow-up of a phase 1 clinical study","volume":"25","author":"Fagerholm","year":"2010","journal-title":"Sci Transl Med"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib14","first-page":"332","article-title":"The correction of refractive errors with polysulfone corneal inlays","volume":"104","author":"Choyce","year":"1985","journal-title":"Trans Ophthalmol Soc UK"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib15","series-title":"Refractive corneal surgery","first-page":"549","article-title":"Polysulfone intracorneal lenses","author":"Lindstrom","year":"1986"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib16","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/S0886-3350(13)80945-5","article-title":"Assessment of the long-term corneal response to hydrogel intrastromal lenses implanted in monkey eyes for up to five years","volume":"19","author":"McDonald","year":"1993","journal-title":"J\u00a0Cataract Refract Surg"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib17","unstructured":"Lang AJ, Icenogle T, Franz S, Vatz A, Holliday K, Schneider N, et\u00a0al. Clinical Efficacy of the PRESBYLENS\u00ae Intracorneal Inlay for the Correction of Presbyopia. ARVO Annual Meeting 2008;Program number 3353; Poster number A171."},{"issue":"8","key":"10.1016\/j.biomaterials.2011.01.047_bib18","doi-asserted-by":"crossref","first-page":"1455","DOI":"10.1016\/j.ophtha.2009.05.019","article-title":"Hydrogel intracorneal inlays for the correction of hyperopia: outcomes and complicatins after 5 years of follow-up","volume":"116","author":"Mulet","year":"2009","journal-title":"Ophthalmology"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib19","article-title":"Treating presbyopia from inside the cornea","author":"Bethke","year":"2007","journal-title":"Rev Ophthalmol News"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib20","first-page":"1","article-title":"Refractive surgical correction of presbyopia with Acufocus small aperture corneal inlay: two year follow-up","volume":"28","author":"Seyeddain","year":"2010","journal-title":"J\u00a0Refract Surg"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib21","article-title":"Corneal inlays: a surgical correction of presbyopia","author":"Kymionis","year":"2007","journal-title":"Cataract and refractive surgery today"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib22","unstructured":"Meijs GF, Laycock BG, Griffiths MC, Cheong E, Steele JG, Johnson G. Cell growth substrate polymer. US Patent No. 5994133, 1996."},{"key":"10.1016\/j.biomaterials.2011.01.047_bib23","unstructured":"Chaouk H, Meijs GF, Laycock BG. Process for manufacture of a porous polymer from a mixture. US Patent No. 6015609, 2000."},{"issue":"1","key":"10.1016\/j.biomaterials.2011.01.047_bib24","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1111\/j.1444-0938.2007.00198.x","article-title":"Synthetic corneal inlays","volume":"91","author":"Sweeney","year":"2008","journal-title":"Clin Exp Optom"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib25","unstructured":"Hughes TC, Chan GYC. Polymer having charged units. Patent No. WO\/2003\/097711, 2003."},{"key":"10.1016\/j.biomaterials.2011.01.047_bib26","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1016\/j.biomaterials.2005.08.005","article-title":"Approaches to improving the biocompatibility of porous perfluropolyethers for ophthalmic applications","volume":"27","author":"Chan","year":"2006","journal-title":"Biomaterials"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib27","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1167\/iovs.05-0872","article-title":"Two-year preclinical testing of perfluoropolyether as a corneal inlay","volume":"47","author":"Xie","year":"2006","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib28","unstructured":"Prakasam RK, Sweeney DF, Vaddavalli PK, Evans MDM, Hughes TC, Xie R-Z, et\u00a0al. Development of corneal iron rings with corneal inlays. International Society for Contact Lens Research Annual Meeting; Whistler, Canada; August 2007."},{"key":"10.1016\/j.biomaterials.2011.01.047_bib29","doi-asserted-by":"crossref","first-page":"1657","DOI":"10.1016\/j.jcrs.2005.08.057","article-title":"Correction of hyperopia by intracorneal lenses - two-year follow-up","volume":"32","author":"Ismail","year":"2006","journal-title":"J\u00a0Cataract Refract Surg"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib30","series-title":"The cornea and sclera","author":"Maurice","year":"1984"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib31","first-page":"231","article-title":"Development and roles of collagenous matrices in the embryonic avian cornea","volume":"17","author":"Linsenmayer","year":"1998","journal-title":"Prog Ret Eye Res"},{"issue":"2","key":"10.1016\/j.biomaterials.2011.01.047_bib32","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1167\/iovs.02-0838","article-title":"The corneal stroma is endowed with a significant number of resident dendritic cells","volume":"44","author":"Hamrah","year":"2003","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"4","key":"10.1016\/j.biomaterials.2011.01.047_bib33","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1634\/stemcells.2004-0291","article-title":"CD34+ corneal stromal cells are bone marrow-derived and express hemopoietic stem cell markers","volume":"23","author":"Sosnov\u00e1","year":"2005","journal-title":"Stem Cells"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib34","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1159\/000099254","article-title":"Corneal antigen-presenting cells","volume":"92","author":"Hamrah","year":"2007","journal-title":"Chem Immunol Allergy"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib35","doi-asserted-by":"crossref","first-page":"433","DOI":"10.3928\/1081-597X-20050901-04","article-title":"Cohesive tensile strength of human LASIK wounds with histologic, ultrastructural, and clinical correlations","volume":"21","author":"Schmack","year":"2005","journal-title":"J\u00a0Refract Surg"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib36","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1097\/01.ico.0000142110.37166.71","article-title":"Pathologic findings in postmortem corneas after successful laser in situ keratomileusis","volume":"24","author":"Kramer","year":"2005","journal-title":"Cornea"},{"issue":"46","key":"10.1016\/j.biomaterials.2011.01.047_bib37","doi-asserted-by":"crossref","first-page":"45629","DOI":"10.1074\/jbc.M303292200","article-title":"Keratocyte phenotype mediates proteoglycan structure: a role for fibroblasts in corneal fibrosis","volume":"278","author":"Funderburgh","year":"2003","journal-title":"J\u00a0Biol Chem"},{"issue":"17","key":"10.1016\/j.biomaterials.2011.01.047_bib38","doi-asserted-by":"crossref","first-page":"12475","DOI":"10.1074\/jbc.M609280200","article-title":"A\u00a0rapid transient increase in hyaluronan synthase-2 mRNA initiates secretion of hyaluronan by corneal keratocytes in response to transforming growth factor beta","volume":"282","author":"Guo","year":"2007","journal-title":"J\u00a0Biol Chem"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib39","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1097\/00003226-200405000-00021","article-title":"Morphologic characteristics of lamellar channel deposits in the human eye: a case report","volume":"23","author":"Twa","year":"2004","journal-title":"Cornea"},{"issue":"1","key":"10.1016\/j.biomaterials.2011.01.047_bib40","first-page":"S90","article-title":"Biomechanical and wound healing characteristics of corneas after excimer laser keratorefractive surgery: is there a difference between advanced surface ablation and sub-Bowman\u2019s keratomileusis?","volume":"24","author":"Dawson","year":"2008","journal-title":"J\u00a0Refract Surg"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib41","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1097\/00003226-200303000-00014","article-title":"Histologic evaluation of corneal stroma in rabbits after intrastromal corneal ring implantation","volume":"22","author":"Twa","year":"2003","journal-title":"Cornea"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib42","series-title":"Corneo-Plastic surgery","first-page":"197","article-title":"Nutritional aspects of corneal grafts and prostheses","author":"Maurice","year":"1969"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib43","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.3109\/02713689008997577","article-title":"Modeling glucose distribution in the cornea","volume":"9","author":"McCarey","year":"1990","journal-title":"Curr Eye Res"},{"key":"10.1016\/j.biomaterials.2011.01.047_bib44","doi-asserted-by":"crossref","first-page":"2152","DOI":"10.1016\/j.jcrs.2004.02.093","article-title":"PermaVision intracorneal lens for the correction of hyperopia","volume":"30","author":"Michieletto","year":"2004","journal-title":"J\u00a0Cat Refract Surg"},{"issue":"2","key":"10.1016\/j.biomaterials.2011.01.047_bib45","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.jcrs.2007.10.011","article-title":"Corneal intrastromal implantation surgery for the treatment of moderate and high myopia","volume":"34","author":"Daxer","year":"2008","journal-title":"J\u00a0Cataract Refract Surg"}],"container-title":["Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0142961211000731?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0142961211000731?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T15:25:37Z","timestamp":1758900337000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0142961211000731"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,4]]},"references-count":45,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2011,4]]}},"alternative-id":["S0142961211000731"],"URL":"https:\/\/doi.org\/10.1016\/j.biomaterials.2011.01.047","relation":{},"ISSN":["0142-9612"],"issn-type":[{"value":"0142-9612","type":"print"}],"subject":[],"published":{"date-parts":[[2011,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A perfluoropolyether corneal inlay for the correction of refractive error","name":"articletitle","label":"Article Title"},{"value":"Biomaterials","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.biomaterials.2011.01.047","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Crown copyright \u00a9 2011 Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}