{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T15:12:25Z","timestamp":1791040345722,"version":"4.1.0"},"reference-count":20,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2004,7,1]],"date-time":"2004-07-01T00:00:00Z","timestamp":1088640000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2004,7,1]],"date-time":"2004-07-01T00:00:00Z","timestamp":1088640000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Biosensors and Bioelectronics"],"published-print":{"date-parts":[[2004,7]]},"DOI":"10.1016\/j.bios.2003.10.018","type":"journal-article","created":{"date-parts":[[2004,3,16]],"date-time":"2004-03-16T05:24:03Z","timestamp":1079414643000},"page":"115-121","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":89,"title":["Simulation of two-dimensional fully developed laminar flow for a magneto-hydrodynamic (MHD) pump"],"prefix":"10.1016","volume":"20","author":[{"given":"Pei-Jen","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chia-Yuan","family":"Chang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ming-Lang","family":"Chang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"12","key":"10.1016\/j.bios.2003.10.018_BIB1","doi-asserted-by":"crossref","first-page":"981","DOI":"10.2355\/isijinternational.29.981","article-title":"Birth and recent activities of electromagnetic processing of materials","volume":"29","author":"Asai","year":"1989","journal-title":"ISIJ Int."},{"key":"10.1016\/j.bios.2003.10.018_BIB2","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/0924-4247(90)85037-5","article-title":"Microfabricated electrohydrodynamic pumps","volume":"21","author":"Bart","year":"1997","journal-title":"Sens. Actuators A"},{"key":"10.1016\/j.bios.2003.10.018_BIB3","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1117\/12.359355","article-title":"Development of a diffuser\/nozzle type micro-pump based on magnetohydrodynamic (MHD) principle","volume":"3877","author":"Heng","year":"1999","journal-title":"Proc. SPIE\u2014Microfluidic Devices Syst. II"},{"key":"10.1016\/j.bios.2003.10.018_BIB4","first-page":"174","article-title":"UV-LIGA microfabrication and test of an ac-type micro-pump based on the magnetohydrodynamic (MHD) principle","volume":"4177","author":"Heng","year":"2000","journal-title":"Proc. SPIE\u2014Microfluidic Dev. Syst. III"},{"key":"10.1016\/j.bios.2003.10.018_BIB5","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1117\/12.341223","article-title":"A lumped-parameter model for a micro-pump based on the magnetohydrodynamic (MHD) principle","volume":"3680","author":"Huang","year":"1999","journal-title":"Proc. SPIE\u2013Design Test Microfabric. MEMS MOEMS"},{"key":"10.1016\/j.bios.2003.10.018_BIB6","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1007\/s005420000068","article-title":"LIGA fabrication and test of a dc type magneto-hydrodynamic (MHD) micro-pump","volume":"6","author":"Huang","year":"2000","journal-title":"Microsyst. Technol."},{"key":"10.1016\/j.bios.2003.10.018_BIB7","doi-asserted-by":"crossref","unstructured":"Hughes, M., Pericleous, K.A., Cross, M., 1995. The numerical modeling of dc electromagnetic pump and brake flow. Appl. Math. Model 19, 713\u2013723.","DOI":"10.1016\/0307-904X(95)00110-6"},{"key":"10.1016\/j.bios.2003.10.018_BIB8","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1016\/S0924-4247(99)00302-7","article-title":"Theoretical and experimental study of MHD micro-pump","volume":"80","author":"Jang","year":"2000","journal-title":"Sens. Actuators A"},{"key":"10.1016\/j.bios.2003.10.018_BIB9","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/S0924-4247(99)00392-1","article-title":"Fabrication and test of a thermo-pneumatic micro-pump with a corrugated p+ diaphragm","volume":"83","author":"Jeong","year":"2000","journal-title":"Sens. Actuators A"},{"key":"10.1016\/j.bios.2003.10.018_BIB10","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/S0925-4005(00)00355-5","article-title":"An ac magnetohydrodynamic micro-pump","volume":"63","author":"Lemoff","year":"2000","journal-title":"Sens. Actuators B"},{"key":"10.1016\/j.bios.2003.10.018_BIB11","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/S0142-727X(98)10043-7","article-title":"Flow characteristics of water in microtubes","volume":"20","author":"Mala","year":"1999","journal-title":"Int. J. Heat Fluid Flow"},{"key":"10.1016\/j.bios.2003.10.018_BIB12","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1088\/0960-1317\/4\/4\/010","article-title":"Electro-osmotic pumping and electrophoretic separations for miniaturized chemical analysis systems","volume":"4","author":"Manz","year":"1994","journal-title":"J. Micromech. Microeng."},{"key":"10.1016\/j.bios.2003.10.018_BIB13","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/S0924-4247(98)00039-9","article-title":"Hybrid-assembled micro dosing system using silicon-based micro-pump\/valve and mass flow sensor","volume":"69","author":"Nguyen","year":"1998","journal-title":"Sens. Actuators A"},{"issue":"2","key":"10.1016\/j.bios.2003.10.018_BIB14","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1109\/84.585794","article-title":"Micromachined flat-walled valveless diffuser pumps","volume":"6","author":"Olsson","year":"1997","journal-title":"J. Microelectromech. Syst."},{"key":"10.1016\/j.bios.2003.10.018_BIB15","first-page":"149","article-title":"Liquid and gas transport in small channels","volume":"19","author":"Pfahler","year":"1990","journal-title":"ASME DSC"},{"key":"10.1016\/j.bios.2003.10.018_BIB16","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1002\/fld.1650110614","article-title":"Finite difference and finite element methods for MHD channel flows","volume":"11","author":"Ramos","year":"1990","journal-title":"Int. J. Num. Methods Fluids"},{"key":"10.1016\/j.bios.2003.10.018_BIB17","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/0924-4247(94)85030-5","article-title":"LIGA micro-pump for gases and liquids","volume":"40","author":"Rapp","year":"1994","journal-title":"Sens. Actuators A"},{"key":"10.1016\/j.bios.2003.10.018_BIB18","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/0924-4247(91)87118-M","article-title":"A micromachined electrohydrodynamic (EHD) pump","volume":"29","author":"Richter","year":"1991","journal-title":"Sens. Actuators A"},{"issue":"2","key":"10.1016\/j.bios.2003.10.018_BIB19","first-page":"1228","article-title":"Numerical simulation of electromagnetic pump flow","volume":"5","author":"Winowich","year":"1987","journal-title":"Numer. Methods Laminar Turbulent Flow"},{"key":"10.1016\/j.bios.2003.10.018_BIB20","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/0924-4247(96)80088-4","article-title":"A bi-directional silicon micro-pump","volume":"50","author":"Zengerle","year":"1995","journal-title":"Sens. Actuators A"}],"container-title":["Biosensors and Bioelectronics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0956566304000624?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0956566304000624?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T18:16:52Z","timestamp":1760638612000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0956566304000624"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,7]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2004,7]]}},"alternative-id":["S0956566304000624"],"URL":"https:\/\/doi.org\/10.1016\/j.bios.2003.10.018","relation":{},"ISSN":["0956-5663"],"issn-type":[{"value":"0956-5663","type":"print"}],"subject":[],"published":{"date-parts":[[2004,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Simulation of two-dimensional fully developed laminar flow for a magneto-hydrodynamic (MHD) pump","name":"articletitle","label":"Article Title"},{"value":"Biosensors and Bioelectronics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.bios.2003.10.018","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"converted-article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2004 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}