{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T04:18:39Z","timestamp":1791260319091,"version":"4.1.0"},"reference-count":30,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2015,2,1]],"date-time":"2015-02-01T00:00:00Z","timestamp":1422748800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2015,2,1]],"date-time":"2015-02-01T00:00:00Z","timestamp":1422748800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Biosensors and Bioelectronics"],"published-print":{"date-parts":[[2015,2]]},"DOI":"10.1016\/j.bios.2014.09.076","type":"journal-article","created":{"date-parts":[[2014,10,3]],"date-time":"2014-10-03T18:54:05Z","timestamp":1412362445000},"page":"625-632","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":52,"special_numbering":"C","title":["A miniature porous aluminum oxide-based flow-cell for online water quality monitoring using bacterial sensor cells"],"prefix":"10.1016","volume":"64","author":[{"given":"Sharon","family":"Yagur-Kroll","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erik","family":"Schreuder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Colin J.","family":"Ingham","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ren\u00e9","family":"Heideman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rachel","family":"Rosen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shimshon","family":"Belkin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"7","key":"10.1016\/j.bios.2014.09.076_bib1","doi-asserted-by":"crossref","first-page":"2730","DOI":"10.1128\/AEM.64.7.2730-2735.1998","article-title":"A chromosomally based tod-luxcdabewhole-cell reporter for benzene, toluene, ethybenzene, and xylene (BTEX) sensing","volume":"64","author":"Applegate","year":"1998","journal-title":"Appl. Environ. Microbiol."},{"issue":"3","key":"10.1016\/j.bios.2014.09.076_bib2","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/S1369-5274(03)00059-6","article-title":"Microbial whole-cell sensing systems of environmental pollutants","volume":"6","author":"Belkin","year":"2003","journal-title":"Curr. Opin. Microbiol."},{"issue":"4","key":"10.1016\/j.bios.2014.09.076_bib3","doi-asserted-by":"crossref","first-page":"337","DOI":"10.3109\/07388551.2010.532767","article-title":"Whole-cell biochips for bio-sensing: integration of live cells and inanimate surfaces","volume":"31","author":"Ben-Yoav","year":"2011","journal-title":"Crit. Rev. Biotechnol."},{"key":"10.1016\/j.bios.2014.09.076_bib4","first-page":"161","article-title":"Genetically Engineered Bacteria for Genotoxicity Assessment. Biosensors for Environmental Monitoring of Aquatic Systems","volume":"5J","author":"Biran","year":"2009"},{"issue":"14","key":"10.1016\/j.bios.2014.09.076_bib5","doi-asserted-by":"crossref","first-page":"2369","DOI":"10.1039\/c1lc20274j","article-title":"Development of a microfluidics biosensor for agarose-bead immobilized Escherichia coli bioreporter cells for arsenite detection in aqueous samples","volume":"11","author":"Buffi","year":"2011","journal-title":"Lab Chip"},{"issue":"4","key":"10.1016\/j.bios.2014.09.076_bib6","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.1007\/s00216-010-4354-8","article-title":"A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part II: technical development and proof of concept of the biosensor","volume":"400","author":"Charrier","year":"2011","journal-title":"Anal. Bioanal. Chem."},{"issue":"3","key":"10.1016\/j.bios.2014.09.076_bib7","doi-asserted-by":"crossref","first-page":"927","DOI":"10.1128\/AEM.01372-09","article-title":"Direct-imaging-based quantification of bacillus cereus ATCC 14579 population heterogeneity at a low incubation temperature","volume":"76","author":"den Besten","year":"2010","journal-title":"Appl. Environ. Microbiol."},{"issue":"6","key":"10.1016\/j.bios.2014.09.076_bib8","doi-asserted-by":"crossref","first-page":"e11008","DOI":"10.1371\/journal.pone.0011008","article-title":"Simplified automated image analysis for detection and phenotyping of mycobacterium tuberculosis on porous supports by monitoring growing microcolonies","volume":"5","author":"den Hertog","year":"2010","journal-title":"PLoS ONE"},{"issue":"19","key":"10.1016\/j.bios.2014.09.076_bib9","doi-asserted-by":"crossref","first-page":"8536","DOI":"10.1021\/es202465c","article-title":"Online Monitoring of Water Toxicity by Use of Bioluminescent Reporter Bacterial Biochips","volume":"45","author":"Elad","year":"2011","journal-title":"Environ. Sci. Technol."},{"issue":"11","key":"10.1016\/j.bios.2014.09.076_bib10","doi-asserted-by":"crossref","first-page":"3782","DOI":"10.1016\/j.watres.2013.04.011","article-title":"Broad spectrum detection and \u201cbarcoding\u201d of water pollutants by a genome-wide bacterial sensor array","volume":"47","author":"Elad","year":"2013","journal-title":"Water Res."},{"issue":"2","key":"10.1016\/j.bios.2014.09.076_bib11","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1111\/j.1751-7915.2007.00021.x","article-title":"Microbial whole-cell arrays","volume":"1","author":"Elad","year":"2008","journal-title":"Microb. Biotechnol."},{"issue":"1","key":"10.1016\/j.bios.2014.09.076_bib12","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.snb.2009.08.024","article-title":"Flow-through real time bacterial biosensor for toxic compounds in water","volume":"142","author":"Eltzov","year":"2009","journal-title":"Sens. Actuators B: Chem."},{"issue":"1","key":"10.1016\/j.bios.2014.09.076_bib13","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1021\/es970442j","article-title":"New online biomonitoring system for gammarus pulex (L.) (Crustacea): in situ test below a copper effluent in south Sweden","volume":"32","author":"Gerhardt","year":"1998","journal-title":"Environ. Sci. Technol."},{"issue":"9","key":"10.1016\/j.bios.2014.09.076_bib14","doi-asserted-by":"crossref","first-page":"2263","DOI":"10.1897\/05-486R1.1","article-title":"In situ on-line toxicity biomonitoring in water: Recent developments","volume":"25","author":"Gerhardt","year":"2006","journal-title":"Environ. Toxicol. Chem."},{"issue":"3","key":"10.1016\/j.bios.2014.09.076_bib15","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1002\/elsc.200620132","article-title":"A Dual-color bacterial reporter strain for the detection of toxic and genotoxic effects","volume":"6","author":"Hever","year":"2006","journal-title":"Eng. Life Sci."},{"issue":"2","key":"10.1016\/j.bios.2014.09.076_bib16","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1016\/j.snb.2006.06.033","article-title":"Technological conception of an optical biosensor with a disposable card for use with bioluminescent bacteria","volume":"122","author":"Horry","year":"2007","journal-title":"Sensors and Actuators B: Chemical"},{"issue":"11","key":"10.1016\/j.bios.2014.09.076_bib17","doi-asserted-by":"crossref","first-page":"1410","DOI":"10.1039\/b925796a","article-title":"High-resolution microcontact printing and transfer of massive arrays of microorganisms on planar and compartmentalized nanoporous aluminium oxide","volume":"10","author":"Ingham","year":"2010","journal-title":"Lab on a Chip"},{"issue":"46","key":"10.1016\/j.bios.2014.09.076_bib18","doi-asserted-by":"crossref","first-page":"18217","DOI":"10.1073\/pnas.0701693104","article-title":"The micro-Petri dish, a million-well growth chip for the culture and high-throughput screening of microorganisms","volume":"104","author":"Ingham","year":"2007","journal-title":"Proceedings of the National Academy of Sciences"},{"issue":"5","key":"10.1016\/j.bios.2014.09.076_bib19","doi-asserted-by":"crossref","first-page":"1089","DOI":"10.1016\/j.biotechadv.2011.08.005","article-title":"Where bio meets nano: The many uses for nanoporous aluminum oxide in biotechnology","volume":"30","author":"Ingham","year":"2012","journal-title":"Biotechnology Advances"},{"issue":"9\u201310","key":"10.1016\/j.bios.2014.09.076_bib20","doi-asserted-by":"crossref","first-page":"2223","DOI":"10.1016\/j.bios.2006.10.038","article-title":"An oxidative stress-specific bacterial cell array chip for toxicity analysis","volume":"22","author":"Lee","year":"2007","journal-title":"Biosensors and Bioelectronics"},{"issue":"1-4","key":"10.1016\/j.bios.2014.09.076_bib21","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1007\/s11270-009-9978-y","article-title":"Lead Bioavailability in Soil and Soil Components","volume":"202","author":"Magrisso","year":"2009","journal-title":"Water, Air, and Soil Pollution"},{"issue":"1","key":"10.1016\/j.bios.2014.09.076_bib22","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1039\/C0LC00243G","article-title":"A printed nanolitre-scale bacterial sensor array","volume":"11","author":"Melamed","year":"2011","journal-title":"Lab on a Chip"},{"issue":"4","key":"10.1016\/j.bios.2014.09.076_bib23","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1111\/j.1751-7915.2012.00333.x","article-title":"A bacterial reporter panel for the detection and classification of antibiotic substances","volume":"5","author":"Melamed","year":"2012","journal-title":"Microbial Biotechnology"},{"issue":"11","key":"10.1016\/j.bios.2014.09.076_bib24","doi-asserted-by":"crossref","first-page":"1243","DOI":"10.1094\/MPMI.2000.13.11.1243","article-title":"Improved gfp and inaZ Broad-Host-Range Promoter-Probe Vectors","volume":"13","author":"Miller","year":"2000","journal-title":"Molecular Plant-Microbe Interactions"},{"key":"10.1016\/j.bios.2014.09.076_bib25","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1007\/s00128-001-0018-x","article-title":"Long-term operation of an automated fish biomonitoring system for continuous effluent acute toxicity surveillance","volume":"66","author":"Shedd","year":"2001","journal-title":"Bull. Environ. Contam. Toxicol"},{"issue":"19","key":"10.1016\/j.bios.2014.09.076_bib26","doi-asserted-by":"crossref","first-page":"7625","DOI":"10.1021\/es050992e","article-title":"Bacterial Bioassay for Rapid and Accurate Analysis of Arsenic in Highly Variable Groundwater Samples","volume":"39","author":"Trang","year":"2005","journal-title":"Environmental Science & Technology"},{"issue":"7","key":"10.1016\/j.bios.2014.09.076_bib27","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1038\/nrmicro2392","article-title":"Where microbiology meets microengineering: design and applications of reporter bacteria","volume":"8","author":"van der Meer","year":"2010","journal-title":"Nat Rev Micro"},{"issue":"3","key":"10.1016\/j.bios.2014.09.076_bib28","doi-asserted-by":"crossref","first-page":"1006","DOI":"10.1128\/AEM.64.3.1006-1012.1998","article-title":"Development and Testing of a Bacterial Biosensor for Toluene-Based Environmental Contaminants","volume":"64","author":"Willardson","year":"1998","journal-title":"Applied and Environmental Microbiology"},{"key":"10.1016\/j.bios.2014.09.076_bib29","first-page":"1","article-title":"Escherichia coli bioreporters for the detection of 2.4-dinitrotoluene and 2.4.6-trinitrotoluene","author":"Yagur-Kroll","year":"2013","journal-title":"Applied Microbiology and Biotechnology"},{"issue":"8","key":"10.1016\/j.bios.2014.09.076_bib30","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1038\/nmeth895","article-title":"A comprehensive library of fluorescent transcriptional reporters for Escherichia coli","volume":"3","author":"Zaslaver","year":"2006","journal-title":"Nat Meth"}],"container-title":["Biosensors and Bioelectronics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0956566314007635?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0956566314007635?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,17]],"date-time":"2025-10-17T00:16:34Z","timestamp":1760660194000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0956566314007635"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,2]]},"references-count":30,"alternative-id":["S0956566314007635"],"URL":"https:\/\/doi.org\/10.1016\/j.bios.2014.09.076","relation":{},"ISSN":["0956-5663"],"issn-type":[{"value":"0956-5663","type":"print"}],"subject":[],"published":{"date-parts":[[2015,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A miniature porous aluminum oxide-based flow-cell for online water quality monitoring using bacterial sensor cells","name":"articletitle","label":"Article Title"},{"value":"Biosensors and Bioelectronics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.bios.2014.09.076","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}