{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T00:17:41Z","timestamp":1791332261369,"version":"4.3.1"},"reference-count":26,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2015,8,1]],"date-time":"2015-08-01T00:00:00Z","timestamp":1438387200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2015,8,1]],"date-time":"2015-08-01T00:00:00Z","timestamp":1438387200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100003200","name":"MOSTI","doi-asserted-by":"crossref","award":["02-01-05-SF0471"],"award-info":[{"award-number":["02-01-05-SF0471"]}],"id":[{"id":"10.13039\/501100003200","id-type":"DOI","asserted-by":"crossref"}]},{"name":"HIR, UM","award":["A000001-50001"],"award-info":[{"award-number":["A000001-50001"]}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Biosensors and Bioelectronics"],"published-print":{"date-parts":[[2015,8]]},"DOI":"10.1016\/j.bios.2015.03.048","type":"journal-article","created":{"date-parts":[[2015,3,30]],"date-time":"2015-03-30T22:50:25Z","timestamp":1427755825000},"page":"282-288","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":24,"special_numbering":"C","title":["Enzymatic electrochemical detection of epidemic-causing Vibrio cholerae with a disposable oligonucleotide-modified screen-printed bisensor coupled to a dry-reagent-based nucleic acid amplification assay"],"prefix":"10.1016","volume":"70","author":[{"given":"Choo Yee","family":"Yu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Geik Yong","family":"Ang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kok Gan","family":"Chan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kirnpal Kaur","family":"Banga Singh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yean Yean","family":"Chan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.bios.2015.03.048_bib1","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/j.bios.2012.05.019","article-title":"Ambient temperature detection of PCR amplicons with a novel sequence-specific nucleic acid lateral flow biosensor","volume":"38","author":"Ang","year":"2012","journal-title":"Biosens. Bioelectron."},{"issue":"2","key":"10.1016\/j.bios.2015.03.048_bib2","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1002\/j.1460-2075.1995.tb06993.x","article-title":"Genesis of the novel epidemic Vibrio cholerae O139 strain: evidence for horizontal transfer of genes involved in polysaccharide synthesis","volume":"14","author":"Bik","year":"1995","journal-title":"EMBO J."},{"key":"10.1016\/j.bios.2015.03.048_bib3","series-title":"Rational Design of Stable Protein Formulations","first-page":"109","article-title":"Rational design of stable lyophilized protein formulations: theory and practice","author":"Carpenter","year":"2002"},{"key":"10.1016\/j.bios.2015.03.048_bib4","unstructured":"Clark,\u00a0G.S., 1991. Shelf life of medical devices. Food Drug Administration."},{"issue":"12","key":"10.1016\/j.bios.2015.03.048_bib5","doi-asserted-by":"crossref","first-page":"2906","DOI":"10.1016\/j.bios.2006.12.006","article-title":"Evaluation of the analytical performances of avidin-modified carbon sensors based on a mediated horseradish peroxidase enzyme label and their application to the amperometric detection of nucleic acids","volume":"22","author":"Djellouli","year":"2007","journal-title":"Biosens. Bioelectron"},{"issue":"8","key":"10.1016\/j.bios.2015.03.048_bib6","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1016\/j.elecom.2005.05.006","article-title":"Electrochemical genomagnetic assay for the detection of hepatitis B virus DNA in polymerase chain reaction amplicons by using disposable sensor technology","volume":"7","author":"Erdem","year":"2005","journal-title":"Electrochem. Commun."},{"issue":"5","key":"10.1016\/j.bios.2015.03.048_bib7","doi-asserted-by":"crossref","first-page":"1863","DOI":"10.1128\/JCM.42.5.1863-1868.2004","article-title":"Practical considerations in design of internal amplification controls for diagnostic PCR assays","volume":"42","author":"Hoorfar","year":"2004","journal-title":"J. Clin. Microbiol."},{"issue":"11","key":"10.1016\/j.bios.2015.03.048_bib8","doi-asserted-by":"crossref","first-page":"4017","DOI":"10.1073\/pnas.0511325103","article-title":"Rapid, sequence-specific detection of unpurified PCR amplicons via a reusable, electrochemical sensor","volume":"103","author":"Lai","year":"2006","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"10.1016\/j.bios.2015.03.048_bib9","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.bios.2013.03.004","article-title":"A thermostabilized magnetogenosensing assay for DNA sequence-specific detection and quantification of Vibrio cholerae","volume":"47","author":"Low","year":"2013","journal-title":"Biosens. Bioelectron."},{"issue":"6","key":"10.1016\/j.bios.2015.03.048_bib10","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/S0956-5663(03)00256-2","article-title":"Carbon and gold electrodes as electrochemical transducers for DNA hybridisation sensors","volume":"19","author":"Lucarelli","year":"2004","journal-title":"Biosens. Bioelectron."},{"issue":"3","key":"10.1016\/j.bios.2015.03.048_bib11","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1038\/nrmicro841","article-title":"Diagnostics for the developing world","volume":"2","author":"Mabey","year":"2004","journal-title":"Nat. Rev. Microbiol."},{"issue":"2","key":"10.1016\/j.bios.2015.03.048_bib12","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/S0167-7012(02)00018-0","article-title":"A comparison of five methods for extraction of bacterial DNA from human faecal samples","volume":"50","author":"McOrist","year":"2002","journal-title":"J. Microbiol. Methods"},{"issue":"8","key":"10.1016\/j.bios.2015.03.048_bib13","doi-asserted-by":"crossref","first-page":"2390","DOI":"10.1016\/j.bios.2008.12.014","article-title":"PCR-coupled electrochemical sensing of Legionella pneumophila","volume":"24","author":"Miranda-Castro","year":"2009","journal-title":"Biosens. Bioelectron."},{"key":"10.1016\/j.bios.2015.03.048_bib14","series-title":"Molecular Diagnostics: Promises and Possibilities","author":"Mousumi","year":"2010"},{"issue":"4","key":"10.1016\/j.bios.2015.03.048_bib15","doi-asserted-by":"crossref","first-page":"780","DOI":"10.1039\/c0ay00755b","article-title":"Electrochemical genosensors based on PCR strategies for microorganisms detection and quantification","volume":"3","author":"Pedrero","year":"2011","journal-title":"Anal. Methods"},{"issue":"8","key":"10.1016\/j.bios.2015.03.048_bib16","doi-asserted-by":"crossref","first-page":"1062","DOI":"10.1111\/j.1469-0691.2010.03279.x","article-title":"Point-of-care tests for diagnosing infections in the developing world","volume":"16","author":"Peeling","year":"2010","journal-title":"Clin. Microbiol. Infect."},{"issue":"24","key":"10.1016\/j.bios.2015.03.048_bib17","doi-asserted-by":"crossref","first-page":"5163","DOI":"10.1093\/nar\/29.24.5163","article-title":"The effect of surface probe density on DNA hybridization","volume":"29","author":"Peterson","year":"2001","journal-title":"Nucleic Acids Res."},{"issue":"24","key":"10.1016\/j.bios.2015.03.048_bib18","doi-asserted-by":"crossref","first-page":"8609","DOI":"10.1073\/pnas.0501946102","article-title":"Linear-After-The-Exponential (LATE)-PCR: primer design criteria for high yields of specific single-stranded DNA and improved real-time detection","volume":"102","author":"Pierce","year":"2005","journal-title":"Proc. Natl. Acad. Sci. USA"},{"issue":"9","key":"10.1016\/j.bios.2015.03.048_bib19","doi-asserted-by":"crossref","first-page":"1207","DOI":"10.2116\/analsci.22.1207","article-title":"Amperometric immunosensor for the detection of Vibrio cholerae O1 using disposable screen-printed electrodes","volume":"22","author":"Rao","year":"2006","journal-title":"Anal. Sci."},{"issue":"1","key":"10.1016\/j.bios.2015.03.048_bib20","doi-asserted-by":"crossref","first-page":"e1003","DOI":"10.1371\/journal.pntd.0001003","article-title":"The cholera pandemic, still with us after half a century: time to rethink","volume":"5","author":"Ryan","year":"2011","journal-title":"PLoS Negl. Trop. Dis."},{"issue":"9404","key":"10.1016\/j.bios.2015.03.048_bib21","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/S0140-6736(03)15328-7","article-title":"Cholera","volume":"363","author":"Sack","year":"2004","journal-title":"Lancet"},{"key":"10.1016\/j.bios.2015.03.048_bib22","series-title":"Lyophilization of Biopharmaceuticals","first-page":"229","article-title":"The role of water in physical transformations in freeze-dried products","author":"Shamblin","year":"2004"},{"issue":"10","key":"10.1016\/j.bios.2015.03.048_bib23","doi-asserted-by":"crossref","first-page":"1887","DOI":"10.1016\/j.bios.2005.10.027","article-title":"Electrochemical biosensors: towards point-of-care cancer diagnostics","volume":"21","author":"Wang","year":"2006","journal-title":"Biosens. Bioelectron."},{"key":"10.1016\/j.bios.2015.03.048_bib24","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1146\/annurev.bioeng.10.061807.160524","article-title":"Point-of-care diagnostics for global health","volume":"10","author":"Yager","year":"2008","journal-title":"Annu. Rev. Biomed. Eng."},{"issue":"20","key":"10.1016\/j.bios.2015.03.048_bib25","doi-asserted-by":"crossref","first-page":"2019","DOI":"10.1039\/c3cc39144b","article-title":"Multiplex electrochemical genosensor for identifying toxigenic Vibrio cholerae serogroups O1 and O139","volume":"49","author":"Yu","year":"2013","journal-title":"Chem. Commun."},{"issue":"1","key":"10.1016\/j.bios.2015.03.048_bib26","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/j.bios.2011.11.048","article-title":"Label-free and reagentless electrochemical detection of PCR fragments using self-assembled quinone derivative monolayer: application to Mycobacterium tuberculosis","volume":"32","author":"Zhang","year":"2012","journal-title":". Biosens. Bioelectron."}],"container-title":["Biosensors and Bioelectronics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0956566315002006?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0956566315002006?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,17]],"date-time":"2025-10-17T00:14:30Z","timestamp":1760660070000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0956566315002006"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,8]]},"references-count":26,"alternative-id":["S0956566315002006"],"URL":"https:\/\/doi.org\/10.1016\/j.bios.2015.03.048","relation":{},"ISSN":["0956-5663"],"issn-type":[{"value":"0956-5663","type":"print"}],"subject":[],"published":{"date-parts":[[2015,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Enzymatic electrochemical detection of epidemic-causing Vibrio cholerae with a disposable oligonucleotide-modified screen-printed bisensor coupled to a dry-reagent-based nucleic acid amplification assay","name":"articletitle","label":"Article Title"},{"value":"Biosensors and Bioelectronics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.bios.2015.03.048","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}