{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T18:45:47Z","timestamp":1790275547386,"version":"4.1.0"},"reference-count":43,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2018,5,1]],"date-time":"2018-05-01T00:00:00Z","timestamp":1525132800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,5,1]],"date-time":"2018-05-01T00:00:00Z","timestamp":1525132800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100002347","name":"Bundesministerium f\u00fcr Bildung und Forschung","doi-asserted-by":"publisher","award":["03FH012I3"],"award-info":[{"award-number":["03FH012I3"]}],"id":[{"id":"10.13039\/501100002347","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Biosensors and Bioelectronics"],"published-print":{"date-parts":[[2018,5]]},"DOI":"10.1016\/j.bios.2017.12.045","type":"journal-article","created":{"date-parts":[[2017,12,27]],"date-time":"2017-12-27T13:18:43Z","timestamp":1514380723000},"page":"87-94","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":21,"special_numbering":"C","title":["Spore-based biosensor to monitor the microbicidal efficacy of gaseous hydrogen peroxide sterilization processes"],"prefix":"10.1016","volume":"104","author":[{"given":"Jan","family":"Oberl\u00e4nder","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marlena","family":"Mayer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anton","family":"Greeff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Keusgen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael J.","family":"Sch\u00f6ning","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.bios.2017.12.045_bib1","series-title":"Food Microbiology","year":"2008"},{"issue":"1","key":"10.1016\/j.bios.2017.12.045_bib2","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1205\/096030803765208670","volume":"81","author":"Ansari","year":"2003","journal-title":"Food Bioprod. Process."},{"key":"10.1016\/j.bios.2017.12.045_bib3","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.electacta.2017.04.157","volume":"241","author":"Arreola","year":"2017","journal-title":"Electrochim. Acta"},{"issue":"7","key":"10.1016\/j.bios.2017.12.045_bib4","doi-asserted-by":"crossref","first-page":"74004","DOI":"10.1088\/0960-1317\/22\/7\/074004","volume":"22","author":"Aydemir","year":"2012","journal-title":"J. Micromech. Microeng."},{"key":"10.1016\/j.bios.2017.12.045_bib5","doi-asserted-by":"crossref","unstructured":"Bianchi, E., Rollo, E., Kilchenmann, S., Bellati, F.M., Accastelli, E., Guiducci, C., 2012. Detecting particles flowing through interdigitated 3D microelectrodes. In: Proceedings of Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2012. San Diego, California, USA, Aug. 28 - Sept. 1, 2012. IEEE, Piscataway, NJ, pp. 5002\u20135005.","DOI":"10.1109\/EMBC.2012.6347116"},{"issue":"2","key":"10.1016\/j.bios.2017.12.045_bib6","doi-asserted-by":"crossref","first-page":"22001","DOI":"10.1088\/1361-6501\/28\/2\/022001","volume":"28","author":"Blue","year":"2017","journal-title":"Meas. Sci. Technol."},{"key":"10.1016\/j.bios.2017.12.045_bib7","series-title":"Long-Life Products. Heat-Treated, Aseptically Packed: A Guide to Quality","author":"Bockelmann","year":"1998"},{"issue":"1\u20132","key":"10.1016\/j.bios.2017.12.045_bib8","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/S0027-5107(99)00004-4","volume":"424","author":"Cadet","year":"1999","journal-title":"Mutat. Res."},{"issue":"3","key":"10.1016\/j.bios.2017.12.045_bib9","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1128\/jcm.7.3.265-272.1978","volume":"7","author":"Cady","year":"1978","journal-title":"J. Clin. Microbiol."},{"key":"10.1016\/j.bios.2017.12.045_bib10","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/j.sna.2014.09.003","volume":"219","author":"Carminati","year":"2014","journal-title":"Sens. Actuators, A"},{"issue":"2","key":"10.1016\/j.bios.2017.12.045_bib11","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1002\/pts.2770050206","volume":"5","author":"Cerny","year":"1992","journal-title":"Packag. Technol. Sci."},{"key":"10.1016\/j.bios.2017.12.045_bib12","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1016\/j.snb.2015.01.108","volume":"211","author":"Couniot","year":"2015","journal-title":"Sens. Actuators, B"},{"issue":"4","key":"10.1016\/j.bios.2017.12.045_bib13","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1109\/TPS.2006.877739","volume":"34","author":"Deng","year":"2006","journal-title":"IEEE Trans. Plasma Sci."},{"issue":"10","key":"10.1016\/j.bios.2017.12.045_bib14","doi-asserted-by":"crossref","first-page":"2108","DOI":"10.1093\/jac\/dkq308","volume":"65","author":"Finnegan","year":"2010","journal-title":"J. Antimicrob. Chemother."},{"key":"10.1016\/j.bios.2017.12.045_bib15","unstructured":"Food and Drug Administration, 2001. Guide to Inspections of Aseptic Processing and Packaging for the Food Industry."},{"issue":"1","key":"10.1016\/j.bios.2017.12.045_bib16","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/S1369-8001(02)00057-4","volume":"5","author":"Franz","year":"2002","journal-title":"Mat. Sci. Semicon. Proc."},{"issue":"1\u20132","key":"10.1016\/j.bios.2017.12.045_bib17","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/S0925-4005(98)00128-2","volume":"49","author":"Gerwen","year":"1998","journal-title":"Sens. Actuators, B"},{"key":"10.1016\/j.bios.2017.12.045_bib18","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1146\/annurev.micro.61.080706.093224","volume":"61","author":"Henriques","year":"2007","journal-title":"Annu. Rev. Microbiol."},{"issue":"2","key":"10.1016\/j.bios.2017.12.045_bib19","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/j.snb.2010.01.058","volume":"154","author":"Kirchner","year":"2011","journal-title":"Sens. Actuators, B"},{"key":"10.1016\/j.bios.2017.12.045_bib20","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.snb.2011.01.032","volume":"170","author":"Kirchner","year":"2012","journal-title":"Sens. Actuators, B"},{"issue":"2","key":"10.1016\/j.bios.2017.12.045_bib21","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1016\/j.foodcont.2012.11.048","volume":"31","author":"Kirchner","year":"2013","journal-title":"Food Control"},{"issue":"4","key":"10.1016\/j.bios.2017.12.045_bib22","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1128\/AEM.03010-15","volume":"82","author":"Leggett","year":"2015","journal-title":"Appl. Environ. Microbiol."},{"issue":"5","key":"10.1016\/j.bios.2017.12.045_bib23","doi-asserted-by":"crossref","first-page":"1555","DOI":"10.1007\/s00216-008-1970-7","volume":"391","author":"Lisdat","year":"2008","journal-title":"Anal. Bioanal. Chem."},{"key":"10.1016\/j.bios.2017.12.045_bib24","series-title":"New Biocides Development. The Combined Approach of Chemistry and Microbiology","first-page":"292","article-title":"Peroxygens and other forms of oxygen: their use for effective cleaning, disinfection, and sterilization","author":"McDonnell","year":"2007"},{"key":"10.1016\/j.bios.2017.12.045_bib25","series-title":"PATAI'S Chemistry of Functional Groups","first-page":"1","article-title":"The use of hydrogen peroxide for disinfection and sterilization applications","author":"McDonnell","year":"2009"},{"issue":"4","key":"10.1016\/j.bios.2017.12.045_bib26","doi-asserted-by":"crossref","first-page":"308","DOI":"10.3390\/s6040308","volume":"6","author":"N\u00e4ther","year":"2006","journal-title":"Sensors"},{"key":"10.1016\/j.bios.2017.12.045_bib27","unstructured":"Neogen Food Safety, 2017. National food laboratory aseptic validation medium, product information. \u3008www.neogen.com\u3009 (accessed 12 September 2017)."},{"issue":"6","key":"10.1016\/j.bios.2017.12.045_bib28","doi-asserted-by":"crossref","first-page":"1299","DOI":"10.1002\/pssa.201431900","volume":"212","author":"Oberl\u00e4nder","year":"2015","journal-title":"Phys. Status Solidi A"},{"issue":"10","key":"10.1016\/j.bios.2017.12.045_bib29","doi-asserted-by":"crossref","first-page":"26115","DOI":"10.3390\/s151026115","volume":"15","author":"Oberl\u00e4nder","year":"2015","journal-title":"Sensors"},{"key":"10.1016\/j.bios.2017.12.045_bib30","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.electacta.2015.06.126","volume":"183","author":"Oberl\u00e4nder","year":"2015","journal-title":"Electrochim. Acta"},{"issue":"6","key":"10.1016\/j.bios.2017.12.045_bib31","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1111\/j.1472-765X.1989.tb00337.x","volume":"9","author":"Owens","year":"1989","journal-title":"Lett. Appl. Microbiol."},{"issue":"2","key":"10.1016\/j.bios.2017.12.045_bib32","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1128\/AEM.66.2.620-626.2000","volume":"66","author":"Riesenman","year":"2000","journal-title":"Appl. Environ. Microbiol."},{"issue":"10","key":"10.1016\/j.bios.2017.12.045_bib33","doi-asserted-by":"crossref","first-page":"3418","DOI":"10.1128\/aem.59.10.3418-3423.1993","volume":"59","author":"Setlow","year":"1993","journal-title":"Appl. Environ. Microbiol."},{"issue":"3","key":"10.1016\/j.bios.2017.12.045_bib34","doi-asserted-by":"crossref","first-page":"514","DOI":"10.1111\/j.1365-2672.2005.02736.x","volume":"101","author":"Setlow","year":"2006","journal-title":"J. Appl. Microbiol."},{"issue":"5","key":"10.1016\/j.bios.2017.12.045_bib35","doi-asserted-by":"crossref","first-page":"731","DOI":"10.3892\/etm.2010.136","volume":"1","author":"Shintani","year":"2010","journal-title":"Exp. Ther. Med."},{"issue":"3","key":"10.1016\/j.bios.2017.12.045_bib36","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1111\/j.1365-2672.1996.tb03215.x","volume":"80","author":"Silley","year":"1996","journal-title":"J. Appl. Bacteriol."},{"key":"10.1016\/j.bios.2017.12.045_bib37","series-title":"Food and Packaging Interactions: Developed from a Symposium Sponsored by the Division of Agricultural and Food Chemistry at the 193rd Meeting of the American Chemical Society, Denver, Colorado, April 5\u201310, 1987","first-page":"94","article-title":"Overview of sterilization methods for aseptic packaging materials","author":"Toledo","year":"1988"},{"issue":"4","key":"10.1016\/j.bios.2017.12.045_bib38","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1128\/am.26.4.592-597.1973","volume":"26","author":"Toledo","year":"1973","journal-title":"Appl. Microbiol."},{"key":"10.1016\/j.bios.2017.12.045_bib39","unstructured":"Verband Deutscher Maschinen- und Anlagenbau e.V. (VDMA), 2008. VDMA-Fachverbandsschriften 6, 1\u201316."},{"key":"10.1016\/j.bios.2017.12.045_bib40","unstructured":"Wallen, S.E., 1976.\u00a0Sporicidal action of hydrogen peroxide. Wallen, S.E., 1976. Sporicidal action of hydrogen peroxide. Ph.D. Thesis, Ames, IA, USA., Ames, IA, USA."},{"issue":"4","key":"10.1016\/j.bios.2017.12.045_bib41","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1046\/j.1365-2672.2000.01015.x","volume":"88","author":"Warriner","year":"2000","journal-title":"J. Appl. Microbiol."},{"issue":"1","key":"10.1016\/j.bios.2017.12.045_bib42","doi-asserted-by":"crossref","first-page":"37","DOI":"10.5194\/jsss-4-37-2015","volume":"4","author":"Weiss","year":"2015","journal-title":"J. Sens. Sens. Syst."},{"issue":"1\u20133","key":"10.1016\/j.bios.2017.12.045_bib43","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/S0924-4247(01)00542-8","volume":"92","author":"York","year":"2001","journal-title":"Sens. Actuators, A"}],"container-title":["Biosensors and Bioelectronics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0956566317308503?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0956566317308503?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,17]],"date-time":"2025-10-17T00:43:10Z","timestamp":1760661790000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0956566317308503"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,5]]},"references-count":43,"alternative-id":["S0956566317308503"],"URL":"https:\/\/doi.org\/10.1016\/j.bios.2017.12.045","relation":{},"ISSN":["0956-5663"],"issn-type":[{"value":"0956-5663","type":"print"}],"subject":[],"published":{"date-parts":[[2018,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Spore-based biosensor to monitor the microbicidal efficacy of gaseous hydrogen peroxide sterilization processes","name":"articletitle","label":"Article Title"},{"value":"Biosensors and Bioelectronics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.bios.2017.12.045","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}