{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,4]],"date-time":"2026-07-04T16:20:08Z","timestamp":1783182008217,"version":"3.54.6"},"reference-count":22,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T00:00:00Z","timestamp":1778716800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100007636","name":"Deutsche Bundesstiftung Umwelt","doi-asserted-by":"publisher","award":["37145\/01"],"award-info":[{"award-number":["37145\/01"]}],"id":[{"id":"10.13039\/100007636","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Biosensors and Bioelectronics"],"published-print":{"date-parts":[[2026,9]]},"DOI":"10.1016\/j.bios.2026.118805","type":"journal-article","created":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T11:24:35Z","timestamp":1778757875000},"page":"118805","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["A field-deployable immunofluorescence chip for adenovirus monitoring in groundwater systems"],"prefix":"10.1016","volume":"308","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6997-6907","authenticated-orcid":false,"given":"Mobarok","family":"Hossain","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nele","family":"Hastreiter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Vienken","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"Wegmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dirk","family":"Roggenbuck","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Irina","family":"Engelhardt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.bios.2026.118805_bib1","doi-asserted-by":"crossref","first-page":"808","DOI":"10.1016\/j.bios.2015.07.047","article-title":"SPRi-based adenovirus detection using a surrogate antibody method","volume":"74","author":"Abadian","year":"2015","journal-title":"Biosens. Bioelectron."},{"issue":"21","key":"10.1016\/j.bios.2026.118805_bib2","doi-asserted-by":"crossref","first-page":"17555","DOI":"10.1021\/acsomega.1c07022","article-title":"Development of a rapid immuno-based screening assay for the detection of adenovirus in eye infections","volume":"7","author":"Aloraij","year":"2022","journal-title":"ACS Omega"},{"issue":"11","key":"10.1016\/j.bios.2026.118805_bib3","doi-asserted-by":"crossref","first-page":"8733","DOI":"10.3390\/cimb45110549","article-title":"An analysis of the biotin\u2013(strept) avidin system in immunoassays: interference and mitigation strategies","volume":"45","author":"Balzer","year":"2023","journal-title":"Curr. Issues Mol. Biol."},{"issue":"1","key":"10.1016\/j.bios.2026.118805_bib4","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/rmv.2154","article-title":"Microfluidic devices for detection of RNA viruses","volume":"31","author":"Basiri","year":"2021","journal-title":"Rev. Med. Virol."},{"issue":"6","key":"10.1016\/j.bios.2026.118805_bib5","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0218686","article-title":"Antibody conjugation to carboxyl-modified microspheres through N-hydroxysuccinimide chemistry for automated immunoassay applications: a general procedure","volume":"14","author":"Carl","year":"2019","journal-title":"PLoS One"},{"key":"10.1016\/j.bios.2026.118805_bib6","doi-asserted-by":"crossref","DOI":"10.3389\/fmolb.2021.637559","article-title":"Virus detection: a review of the current and emerging molecular and immunological methods","volume":"8","author":"Cassedy","year":"2021","journal-title":"Front. Mol. Biosci."},{"issue":"107","key":"10.1016\/j.bios.2026.118805_bib7","doi-asserted-by":"crossref","DOI":"10.3791\/52646","article-title":"EPA method 1615. Measurement of enterovirus and norovirus occurrence in water by culture and RT-qPCR. Part III. Virus detection by RT-qPCR","author":"Fout","year":"2016","journal-title":"J. Vis. Exp."},{"issue":"6","key":"10.1016\/j.bios.2026.118805_bib8","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1016\/j.ijheh.2011.07.014","article-title":"Methods to detect infectious human enteric viruses in environmental water samples","volume":"214","author":"Hamza","year":"2011","journal-title":"Int. J. Hyg Environ. Health"},{"issue":"1","key":"10.1016\/j.bios.2026.118805_bib9","doi-asserted-by":"crossref","DOI":"10.1177\/03000605231223083","article-title":"A multiplex recombinase polymerase amplification assay combined with CRISPR\/Cas12a for the detection of respiratory syncytial virus and respiratory adenovirus","volume":"52","author":"Hongdan","year":"2024","journal-title":"J. Int. Med. Res."},{"issue":"6","key":"10.1016\/j.bios.2026.118805_bib10","doi-asserted-by":"crossref","first-page":"3131","DOI":"10.1128\/AEM.71.6.3131-3136.2005","article-title":"Quantitative real-time PCR assays for detection of human adenoviruses and identification of serotypes 40 and 41","volume":"71","author":"Jothikumar","year":"2005","journal-title":"Appl. Environ. Microbiol."},{"key":"10.1016\/j.bios.2026.118805_bib11","series-title":"Calibrating Biosensors in flow-through set-ups: Studies with Glucose Optrodes","first-page":"331","author":"Kivirand","year":"2013"},{"key":"10.1016\/j.bios.2026.118805_bib12","doi-asserted-by":"crossref","DOI":"10.1016\/j.advwatres.2023.104389","article-title":"Numerical investigations to identify environmental factors for field-scale reactive transport of pathogens at riverbank filtration sites","volume":"173","author":"Knabe","year":"2023","journal-title":"Adv. Water Resour."},{"issue":"5","key":"10.1016\/j.bios.2026.118805_bib13","doi-asserted-by":"crossref","first-page":"1442","DOI":"10.1128\/AEM.01937-09","article-title":"Detection of infectious adenoviruses in environmental waters by fluorescence-activated cell sorting assay","volume":"76","author":"Li","year":"2010","journal-title":"Appl. Environ. Microbiol."},{"issue":"1\u20132","key":"10.1016\/j.bios.2026.118805_bib14","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.jviromet.2013.07.009","article-title":"Development of a quantitative immunocapture real-time PCR assay for detecting structurally intact adenoviral particles in water","volume":"194","author":"Ogorzaly","year":"2013","journal-title":"J. Virol. Methods"},{"issue":"20","key":"10.1016\/j.bios.2026.118805_bib15","doi-asserted-by":"crossref","first-page":"4400","DOI":"10.1039\/D3LC00441D","article-title":"LoCKAmp: lab-on-PCB technology for < 3 minute virus genetic detection","volume":"23","author":"Papamatthaiou","year":"2023","journal-title":"Lab Chip"},{"issue":"39","key":"10.1016\/j.bios.2026.118805_bib16","doi-asserted-by":"crossref","DOI":"10.1126\/sciadv.abh2848","article-title":"Direct detection of human adenovirus or SARS-CoV-2 with ability to inform infectivity using DNA aptamer-nanopore sensors","volume":"7","author":"Peinetti","year":"2021","journal-title":"Sci. Adv."},{"key":"10.1016\/j.bios.2026.118805_bib17","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.watres.2016.03.042","article-title":"Technical aspects of using human adenovirus as a viral water quality indicator","volume":"96","author":"Rames","year":"2016","journal-title":"Water Res."},{"issue":"1","key":"10.1016\/j.bios.2026.118805_bib18","article-title":"Molecular and immunological diagnostic techniques of medical viruses","volume":"2020","author":"Reta","year":"2020","journal-title":"Int. J. Microbiol."},{"issue":"8","key":"10.1016\/j.bios.2026.118805_bib19","doi-asserted-by":"crossref","first-page":"1190","DOI":"10.3390\/v16081190","article-title":"Development of a diagnostic microfluidic chip for SARS-CoV-2 detection in saliva and nasopharyngeal samples","volume":"16","author":"Sharma","year":"2024","journal-title":"Viruses"},{"issue":"4","key":"10.1016\/j.bios.2026.118805_bib20","doi-asserted-by":"crossref","DOI":"10.1002\/adpr.202000150","article-title":"On\u2010chip optical detection of viruses: a review","volume":"2","author":"Shi","year":"2021","journal-title":"Adv. Photonic. Res."},{"issue":"20","key":"10.1016\/j.bios.2026.118805_bib21","doi-asserted-by":"crossref","first-page":"4972","DOI":"10.3390\/molecules29204972","article-title":"Advances in virus detection techniques based on recombinant polymerase amplification","volume":"29","author":"Wu","year":"2024","journal-title":"Molecules"},{"issue":"15","key":"10.1016\/j.bios.2026.118805_bib22","doi-asserted-by":"crossref","first-page":"6830","DOI":"10.3390\/s23156830","article-title":"Improvement of sensitivity and speed of virus sensing technologies using nm-and \u03bcm-Scale components","volume":"23","author":"Yasuura","year":"2023","journal-title":"Sensors"}],"container-title":["Biosensors and Bioelectronics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0956566326004379?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0956566326004379?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,7,4]],"date-time":"2026-07-04T16:03:57Z","timestamp":1783181037000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0956566326004379"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9]]},"references-count":22,"alternative-id":["S0956566326004379"],"URL":"https:\/\/doi.org\/10.1016\/j.bios.2026.118805","relation":{},"ISSN":["0956-5663"],"issn-type":[{"value":"0956-5663","type":"print"}],"subject":[],"published":{"date-parts":[[2026,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A field-deployable immunofluorescence chip for adenovirus monitoring in groundwater systems","name":"articletitle","label":"Article Title"},{"value":"Biosensors and Bioelectronics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.bios.2026.118805","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier B.V.","name":"copyright","label":"Copyright"}],"article-number":"118805"}}