{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T12:30:24Z","timestamp":1763037024676},"reference-count":16,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2016,8,1]],"date-time":"2016-08-01T00:00:00Z","timestamp":1470009600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2016,8,6]],"date-time":"2016-08-06T00:00:00Z","timestamp":1470441600000},"content-version":"vor","delay-in-days":5,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Biomedical Journal"],"published-print":{"date-parts":[[2016,8]]},"DOI":"10.1016\/j.bj.2015.12.004","type":"journal-article","created":{"date-parts":[[2016,10,1]],"date-time":"2016-10-01T01:56:49Z","timestamp":1475287009000},"page":"283-288","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"title":["Non-imaging assisted insertion of un-cuffed, non-tunneled internal jugular venous catheters for hemodialysis: Safety and utility in modern day world"],"prefix":"10.1016","volume":"39","author":[{"given":"Manish","family":"Rathi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Venkata Siva Tez","family":"Pinnamaneni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vinay","family":"Sakhuja","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.bj.2015.12.004_bib1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1046\/j.1523-1755.1999.00512.x","article-title":"The hemodialysis catheter conundrum: hate living with them, but can't live without them","volume":"56","author":"Schwab","year":"1999","journal-title":"Kidney Int"},{"key":"10.1016\/j.bj.2015.12.004_bib2","first-page":"208","article-title":"Referral pattern of patients with end-stage renal disease at a public sector hospital and its impact on outcome","volume":"24","author":"Parameswaran","year":"2011","journal-title":"Natl Med J India"},{"key":"10.1016\/j.bj.2015.12.004_bib3","doi-asserted-by":"crossref","first-page":"S248","DOI":"10.1053\/j.ajkd.2006.04.040","article-title":"National Kidney Foundation: KDOQI clinical practice guidelines for vascular access","volume":"48","year":"2006","journal-title":"Am J Kidney Dis"},{"issue":"Suppl.","key":"10.1016\/j.bj.2015.12.004_bib4","first-page":"1","article-title":"KDIGO clinical practice guideline for acute kidney injury","volume":"2","author":"Kidney Disease: Improving Global Outcomes (KDIGO) Acute Kidney Injury Work Group","year":"2012","journal-title":"Kidney Int"},{"key":"10.1016\/j.bj.2015.12.004_bib5","doi-asserted-by":"crossref","first-page":"1249","DOI":"10.1086\/320001","article-title":"Guidelines for the management of intravascular catheter-related infections","volume":"32","author":"Mermel","year":"2001","journal-title":"Clin Infect Dis"},{"key":"10.1016\/j.bj.2015.12.004_bib6","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1086\/599376","article-title":"Clinical practice guidelines for the diagnosis and management of intravascular catheter-related infection: 2009 Update by the Infectious Diseases Society of America","volume":"49","author":"Mermel","year":"2009","journal-title":"Clin Infect Dis"},{"key":"10.1016\/j.bj.2015.12.004_bib7","doi-asserted-by":"crossref","first-page":"3219","DOI":"10.1093\/ndt\/gfn261","article-title":"Vascular access use and outcomes: an international perspective from the dialysis outcomes and practice patterns study","volume":"23","author":"Ethier","year":"2008","journal-title":"Nephrol Dial Transplant"},{"key":"10.1016\/j.bj.2015.12.004_bib8","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1093\/ndt\/13.1.134","article-title":"Anatomical variation of the internal jugular vein and its impact on temporary haemodialysis vascular access: an ultrasonographic survey in uraemic patients","volume":"13","author":"Lin","year":"1998","journal-title":"Nephrol Dial Transplant"},{"key":"10.1016\/j.bj.2015.12.004_bib9","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1159\/000184523","article-title":"Morbidity and mortality of central venous catheter hemodialysis: a review of 10 years' experience","volume":"47","author":"Vanholder","year":"1987","journal-title":"Nephron"},{"key":"10.1016\/j.bj.2015.12.004_bib10","doi-asserted-by":"crossref","first-page":"1234","DOI":"10.1093\/ndt\/12.6.1234","article-title":"Ultrasound-guided cannulation versus the landmark-guided technique for acute haemodialysis access","volume":"12","author":"Farrell","year":"1997","journal-title":"Nephrol Dial Transplant"},{"key":"10.1016\/j.bj.2015.12.004_bib11","unstructured":"National Institute for Clinical Excellence. NICE technology appraisal guidance No 49: http:\/\/publications.nice.org.uk\/guidance-on-the-use-of-ultrasound-locating-devices-for-placing-central-venous-catheters-ta49\/guidance [last accessed on 12.12.13]."},{"key":"10.1016\/j.bj.2015.12.004_bib12","doi-asserted-by":"crossref","first-page":"2940","DOI":"10.1093\/ndt\/gft297","article-title":"A European Renal Best Practice (ERBP) position statement on the kidney disease improving global outcomes (KDIGO) clinical practice guidelines on acute kidney injury: part 2: renal replacement therapy","volume":"28","author":"J\u00f6rres","year":"2013","journal-title":"Nephrol Dial Transplant"},{"key":"10.1016\/j.bj.2015.12.004_bib13","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1046\/j.1523-1755.1999.0550031081.x","article-title":"Septicemia in dialysis patients: incidence, risk factors, and prognosis","volume":"55","author":"Powe","year":"1999","journal-title":"Kidney Int"},{"key":"10.1016\/j.bj.2015.12.004_bib14","doi-asserted-by":"crossref","first-page":"1710","DOI":"10.1093\/ndt\/14.7.1710","article-title":"Outcome and complications of temporary haemodialysis catheters","volume":"14","author":"Kairaitis","year":"1999","journal-title":"Nephrol Dial Transplant"},{"key":"10.1016\/j.bj.2015.12.004_bib15","doi-asserted-by":"crossref","first-page":"2543","DOI":"10.1046\/j.1523-1755.2000.00439.x","article-title":"Risk of bacteremia from temporary hemodialysis catheters by site of insertion and duration of use: a prospective study","volume":"58","author":"Oliver","year":"2000","journal-title":"Kidney Int"},{"key":"10.1016\/j.bj.2015.12.004_bib16","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1046\/j.1440-1797.2003.00139.x","article-title":"Acute vascular access catheters for haemodialysis: complications limiting technique survival","volume":"8","author":"Jefferys","year":"2003","journal-title":"Nephrology"}],"container-title":["Biomedical Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2319417016301792?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2319417016301792?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,8]],"date-time":"2018-09-08T01:21:55Z","timestamp":1536369715000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2319417016301792"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,8]]},"references-count":16,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2016,8]]}},"alternative-id":["S2319417016301792"],"URL":"https:\/\/doi.org\/10.1016\/j.bj.2015.12.004","relation":{},"ISSN":["2319-4170"],"issn-type":[{"value":"2319-4170","type":"print"}],"subject":[],"published":{"date-parts":[[2016,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Non-imaging assisted insertion of un-cuffed, non-tunneled internal jugular venous catheters for hemodialysis: Safety and utility in modern day world","name":"articletitle","label":"Article Title"},{"value":"Biomedical Journal","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.bj.2015.12.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Chang Gung University. Publishing services by Elsevier B.V.","name":"copyright","label":"Copyright"}]}}