{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T23:47:33Z","timestamp":1787788053514,"version":"build-2784847793"},"reference-count":129,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T00:00:00Z","timestamp":1777420800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["bjanaesthesia.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["British Journal of Anaesthesia"],"published-print":{"date-parts":[[2026,7]]},"DOI":"10.1016\/j.bja.2026.04.045","type":"journal-article","created":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T19:54:29Z","timestamp":1780430069000},"page":"39-54","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"title":["Agreement of minimally invasive pulse wave analysis with pulmonary artery and transpulmonary thermodilution cardiac output measurements in perioperative and intensive care medicine: a systematic review and meta-analysis"],"prefix":"10.1016","volume":"137","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4415-9956","authenticated-orcid":false,"given":"Moritz","family":"Flick","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-6215-179X","authenticated-orcid":false,"given":"Dominik X.","family":"M\u00fcller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8240-3812","authenticated-orcid":false,"given":"Alina","family":"Bergholz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pawel","family":"Sierzputowski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6307-8388","authenticated-orcid":false,"given":"Michael","family":"Eichlseder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rami","family":"Saad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9179-9588","authenticated-orcid":false,"given":"Gillis","family":"Greiwe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8107-6952","authenticated-orcid":false,"given":"Karim","family":"Kouz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Hapfelmeier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6619-0722","authenticated-orcid":false,"given":"Bernd","family":"Saugel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.bja.2026.04.045_bib1","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1097\/EJA.0000000000002174","article-title":"Intra-operative haemodynamic monitoring and management of adults having noncardiac surgery: a statement from the European Society of Anaesthesiology and Intensive Care","volume":"42","author":"Saugel","year":"2025","journal-title":"Eur J Anaesthesiol"},{"key":"10.1016\/j.bja.2026.04.045_bib2","doi-asserted-by":"crossref","first-page":"1971","DOI":"10.1007\/s00134-025-08137-z","article-title":"ESICM guidelines on circulatory shock and hemodynamic monitoring 2025","volume":"51","author":"Monnet","year":"2025","journal-title":"Intensive Care Med"},{"key":"10.1016\/j.bja.2026.04.045_bib3","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1016\/j.bja.2022.07.056","article-title":"Endotypes of intraoperative hypotension during major abdominal surgery: a retrospective machine learning analysis of an observational cohort study","volume":"130","author":"Kouz","year":"2023","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.bja.2026.04.045_bib4","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.bja.2024.10.048","article-title":"Deep learning model to identify and validate hypotension endotypes in surgical and critically ill patients","volume":"134","author":"Jian","year":"2025","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.bja.2026.04.045_bib5","doi-asserted-by":"crossref","first-page":"1726","DOI":"10.1056\/NEJMra1208943","article-title":"Circulatory shock","volume":"369","author":"Vincent","year":"2013","journal-title":"N Engl J Med"},{"key":"10.1016\/j.bja.2026.04.045_bib6","first-page":"165","article-title":"Cardiac output monitoring: how to choose the optimal method for the individual patient","volume":"24","author":"Saugel","year":"2018","journal-title":"Curr Opin Crit Care"},{"key":"10.1016\/j.bja.2026.04.045_bib7","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1007\/s10877-021-00662-8","article-title":"The contemporary pulmonary artery catheter. Part 1: placement and waveform analysis","volume":"36","author":"Bootsma","year":"2022","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib8","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s10877-021-00673-5","article-title":"The contemporary pulmonary artery catheter. Part 2: measurements, limitations, and clinical applications","volume":"36","author":"Bootsma","year":"2022","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib9","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1007\/s10877-012-9378-5","article-title":"The transpulmonary thermodilution technique","volume":"26","author":"Sakka","year":"2012","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib10","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.1007\/s00134-016-4375-7","article-title":"Less invasive hemodynamic monitoring in critically ill patients","volume":"42","author":"Teboul","year":"2016","journal-title":"Intensive Care Med"},{"key":"10.1016\/j.bja.2026.04.045_bib11","doi-asserted-by":"crossref","first-page":"1638","DOI":"10.1097\/CCM.0000000000005213","article-title":"Hemodynamic monitoring and support","volume":"49","author":"Vincent","year":"2021","journal-title":"Crit Care Med"},{"key":"10.1016\/j.bja.2026.04.045_bib12","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1007\/s10877-024-01161-2","article-title":"Haemodynamic monitoring during noncardiac surgery: past, present, and future","volume":"38","author":"Kouz","year":"2024","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib13","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1097\/ALN.0000000000003553","article-title":"Pulse wave analysis to estimate cardiac output","volume":"134","author":"Kouz","year":"2021","journal-title":"Anesthesiology"},{"key":"10.1016\/j.bja.2026.04.045_bib14","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.bja.2020.09.049","article-title":"Cardiac output estimation using pulse wave analysis-physiology, algorithms, and technologies: a narrative review","volume":"126","author":"Saugel","year":"2021","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.bja.2026.04.045_bib15","first-page":"215","article-title":"Pulse wave analysis: basic concepts and clinical application in intensive care medicine","volume":"29","author":"Thomsen","year":"2023","journal-title":"Curr Opin Crit Care"},{"key":"10.1016\/j.bja.2026.04.045_bib16","doi-asserted-by":"crossref","DOI":"10.1097\/EA9.0000000000000017","article-title":"Haemodynamic monitoring and management in patients having noncardiac surgery: a survey among members of the European Society of Anaesthesiology and Intensive Care","volume":"2","author":"Flick","year":"2023","journal-title":"Eur J Anaesthesiol Intensive Care"},{"key":"10.1016\/j.bja.2026.04.045_bib17","doi-asserted-by":"crossref","first-page":"1795","DOI":"10.1007\/s00134-014-3525-z","article-title":"Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine","volume":"40","author":"Cecconi","year":"2014","journal-title":"Intensive Care Med"},{"key":"10.1016\/j.bja.2026.04.045_bib18","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1186\/s13054-025-05589-z","article-title":"Not all pulse contour algorithms are created equal","volume":"29","author":"Michard","year":"2025","journal-title":"Crit Care"},{"key":"10.1016\/j.bja.2026.04.045_bib19","doi-asserted-by":"crossref","first-page":"1220","DOI":"10.1097\/ALN.0b013e3181ee3130","article-title":"Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision","volume":"113","author":"Peyton","year":"2010","journal-title":"Anesthesiology"},{"key":"10.1016\/j.bja.2026.04.045_bib20","doi-asserted-by":"crossref","first-page":"W65","DOI":"10.7326\/0003-4819-151-4-200908180-00136","article-title":"The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration","volume":"151","author":"Liberati","year":"2009","journal-title":"Ann Intern Med"},{"key":"10.1016\/j.bja.2026.04.045_bib21","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1097\/ALN.0000000000005559","article-title":"Statistical analysis and reporting of cardiac output method comparison studies (COMPARE) statement","volume":"143","author":"Saugel","year":"2025","journal-title":"Anesthesiology"},{"key":"10.1016\/j.bja.2026.04.045_bib22","doi-asserted-by":"crossref","first-page":"529","DOI":"10.7326\/0003-4819-155-8-201110180-00009","article-title":"QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies","volume":"155","author":"Whiting","year":"2011","journal-title":"Ann Intern Med"},{"key":"10.1016\/j.bja.2026.04.045_bib23","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1093\/bja\/aew461","article-title":"Accuracy and precision of non-invasive cardiac output monitoring devices in perioperative medicine: a systematic review and meta-analysis","volume":"118","author":"Joosten","year":"2017","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.bja.2026.04.045_bib24","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.bja.2020.03.013","article-title":"Continuous noninvasive pulse wave analysis using finger cuff technologies for arterial blood pressure and cardiac output monitoring in perioperative and intensive care medicine: a systematic review and meta-analysis","volume":"125","author":"Saugel","year":"2020","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.bja.2026.04.045_bib25","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1186\/s13054-021-03523-7","article-title":"Agreement between continuous and intermittent pulmonary artery thermodilution for cardiac output measurement in perioperative and intensive care medicine: a systematic review and meta-analysis","volume":"25","author":"Kouz","year":"2021","journal-title":"Crit Care"},{"key":"10.1016\/j.bja.2026.04.045_bib26","doi-asserted-by":"crossref","first-page":"750","DOI":"10.1093\/bja\/aew094","article-title":"Methodology of method comparison studies evaluating the validity of cardiac output monitors: a stepwise approach and checklist","volume":"116","author":"Montenij","year":"2016","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.bja.2026.04.045_bib27","doi-asserted-by":"crossref","first-page":"3621","DOI":"10.1002\/sim.7352","article-title":"A framework for the meta-analysis of Bland-Altman studies based on a limits of agreement approach","volume":"36","author":"Tipton","year":"2017","journal-title":"Stat Med"},{"key":"10.1016\/j.bja.2026.04.045_bib28","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/0197-2456(86)90046-2","article-title":"Meta-analysis in clinical trials","volume":"7","author":"DerSimonian","year":"1986","journal-title":"Control Clin Trials"},{"key":"10.1016\/j.bja.2026.04.045_bib29","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1136\/ebmental-2019-300117","article-title":"How to perform a meta-analysis with R: a practical tutorial","volume":"22","author":"Balduzzi","year":"2019","journal-title":"Evid Based Mental Health"},{"key":"10.1016\/j.bja.2026.04.045_bib30","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1053\/j.jvca.2009.09.019","article-title":"Cardiac index validation using the pressure recording analytic method in unstable patients","volume":"24","author":"Zangrillo","year":"2010","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.bja.2026.04.045_bib31","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1097\/EJA.0b013e3283333a92","article-title":"Cardiac output derived from arterial pressure waveform analysis without calibration vs. thermodilution in septic shock: evolving accuracy of software versions","volume":"27","author":"Slagt","year":"2010","journal-title":"Eur J Anaesthesiol"},{"key":"10.1016\/j.bja.2026.04.045_bib32","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1053\/j.jvca.2009.06.003","article-title":"Uncalibrated radial and femoral arterial pressure waveform analysis for continuous cardiac output measurement: an evaluation in cardiac surgery patients","volume":"24","author":"Hofer","year":"2010","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.bja.2026.04.045_bib33","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1177\/0310057X1003800211","article-title":"Assessment of a cardiac output device using arterial pulse waveform analysis, Vigileo, in cardiac surgery compared to pulmonary arterial thermodilution","volume":"38","author":"Hamm","year":"2010","journal-title":"Anaesth Intensive Care"},{"key":"10.1016\/j.bja.2026.04.045_bib34","first-page":"1010","article-title":"A prospective study of the accuracy and precision of continuous cardiac output monitoring devices as compared to intermittent thermodilution","volume":"76","author":"Cecconi","year":"2010","journal-title":"Minerva Anestesiol"},{"key":"10.1016\/j.bja.2026.04.045_bib35","doi-asserted-by":"crossref","DOI":"10.1186\/cc9335","article-title":"Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters","volume":"14","author":"Hadian","year":"2010","journal-title":"Crit Care"},{"key":"10.1016\/j.bja.2026.04.045_bib36","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1053\/j.jvca.2009.05.029","article-title":"Validity of an arterial pressure waveform analysis device: does the puncture site play a role in the agreement with intermittent pulmonary artery catheter thermodilution measurements?","volume":"24","author":"Schramm","year":"2010","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.bja.2026.04.045_bib37","first-page":"PR1","article-title":"Comparison of arterial pressure cardiac output monitoring with transpulmonary thermodilution in septic patients","volume":"16","author":"Boettger","year":"2010","journal-title":"Med Sci Monit"},{"key":"10.1016\/j.bja.2026.04.045_bib38","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1002\/lt.22056","article-title":"Comparison of calibrated and uncalibrated arterial pressure-based cardiac output monitors during orthotopic liver transplantation","volume":"16","author":"Krejci","year":"2010","journal-title":"Liver Transpl"},{"key":"10.1016\/j.bja.2026.04.045_bib39","doi-asserted-by":"crossref","DOI":"10.1186\/cc9058","article-title":"Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices","volume":"14","author":"Monnet","year":"2010","journal-title":"Crit Care"},{"key":"10.1016\/j.bja.2026.04.045_bib40","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1053\/j.jvca.2010.02.006","article-title":"Comparison of uncalibrated arterial pressure waveform analysis with continuous thermodilution cardiac output measurements in patients undergoing elective off-pump coronary artery bypass surgery","volume":"24","author":"Jeong","year":"2010","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.bja.2026.04.045_bib41","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1007\/s00134-010-2098-8","article-title":"Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients","volume":"37","author":"De Backer","year":"2011","journal-title":"Intensive Care Med"},{"key":"10.1016\/j.bja.2026.04.045_bib42","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1093\/bja\/aer030","article-title":"Comparison of two methods for cardiac output measurement in critically ill patients","volume":"106","author":"Saraceni","year":"2011","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.bja.2026.04.045_bib43","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1093\/bja\/aer170","article-title":"Uncalibrated arterial pressure waveform analysis for cardiac output monitoring is biased by low peripheral resistance in patients with intracranial haemorrhage","volume":"107","author":"Junttila","year":"2011","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.bja.2026.04.045_bib44","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1093\/bja\/aer123","article-title":"Comparison between an uncalibrated pulse contour method and thermodilution technique for cardiac output estimation in septic patients","volume":"107","author":"Franchi","year":"2011","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.bja.2026.04.045_bib45","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1213\/ANE.0b013e31822401b2","article-title":"Evaluation of a new software version of the FloTrac\/Vigileo (version 3.02) and a comparison with previous data in cirrhotic patients undergoing liver transplant surgery","volume":"113","author":"Biancofiore","year":"2011","journal-title":"Anesth Analg"},{"key":"10.1016\/j.bja.2026.04.045_bib46","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1093\/bja\/aeq372","article-title":"Lack of agreement between pulmonary arterial thermodilution cardiac output and the pressure recording analytical method in postoperative cardiac surgery patients","volume":"106","author":"Paarmann","year":"2011","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.bja.2026.04.045_bib47","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1007\/s00540-010-1087-y","article-title":"Accuracy of arterial pressure waveform analysis for cardiac output measurement in comparison with thermodilution methods in patients undergoing living donor liver transplantation","volume":"25","author":"Akiyoshi","year":"2011","journal-title":"J Anesth"},{"key":"10.1016\/j.bja.2026.04.045_bib48","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1053\/j.jvca.2010.07.001","article-title":"Uncalibrated arterial pulse cardiac output measurements in patients with moderately abnormal left ventricular function","volume":"25","author":"Vetrugno","year":"2011","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.bja.2026.04.045_bib49","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1016\/j.resuscitation.2010.12.015","article-title":"Comparison of non-calibrated pulse-contour analysis with continuous thermodilution for cardiac output assessment in patients with induced hypothermia after cardiac arrest","volume":"82","author":"Haenggi","year":"2011","journal-title":"Resuscitation"},{"key":"10.1016\/j.bja.2026.04.045_bib50","doi-asserted-by":"crossref","first-page":"R76","DOI":"10.1186\/cc10065","article-title":"Uncalibrated pulse power analysis fails to reliably measure cardiac output in patients undergoing coronary artery bypass surgery","volume":"15","author":"Broch","year":"2011","journal-title":"Crit Care"},{"key":"10.1016\/j.bja.2026.04.045_bib51","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1093\/bja\/aer066","article-title":"Performance of cardiac output measurement derived from arterial pressure waveform analysis in patients requiring high-dose vasopressor therapy","volume":"106","author":"Metzelder","year":"2011","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.bja.2026.04.045_bib52","doi-asserted-by":"crossref","first-page":"1389","DOI":"10.1213\/ANE.0b013e318230b2de","article-title":"An uncalibrated pulse contour method to measure cardiac output during aortic counterpulsation","volume":"113","author":"Scolletta","year":"2011","journal-title":"Anesth Analg"},{"key":"10.1016\/j.bja.2026.04.045_bib53","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1510\/icvts.2010.264234","article-title":"Continuous cardiac output monitoring with an uncalibrated pulse contour method in patients supported with mechanical pulsatile assist device","volume":"13","author":"Scolletta","year":"2011","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"10.1016\/j.bja.2026.04.045_bib54","doi-asserted-by":"crossref","first-page":"1014","DOI":"10.1177\/0310057X1103900606","article-title":"A comparison of three minimally invasive cardiac output devices with thermodilution in elective cardiac surgery","volume":"39","author":"Phan","year":"2011","journal-title":"Anaesth Intensive Care"},{"key":"10.1016\/j.bja.2026.04.045_bib55","doi-asserted-by":"crossref","first-page":"237","DOI":"10.4097\/kjae.2011.60.4.237","article-title":"The uncalibrated pulse contour cardiac output during off-pump coronary bypass surgery: performance in patients with a low cardiac output status and a reduced left ventricular function","volume":"60","author":"Jo","year":"2011","journal-title":"Korean J Anesthesiol"},{"key":"10.1016\/j.bja.2026.04.045_bib56","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1016\/j.transproceed.2011.12.036","article-title":"Cardiac output derived from arterial pressure waveform analysis in patients undergoing liver transplantation: validity of a third-generation device","volume":"44","author":"Su","year":"2012","journal-title":"Transplant Proc"},{"key":"10.1016\/j.bja.2026.04.045_bib57","first-page":"2099","article-title":"Application of intraoperative arterial pressure-based cardiac output monitoring for patients undergoing coronary artery bypass grafting surgery","volume":"125","author":"Lu","year":"2012","journal-title":"Chin Med J (Engl)"},{"key":"10.1016\/j.bja.2026.04.045_bib58","doi-asserted-by":"crossref","first-page":"451081","DOI":"10.1100\/2012\/451081","article-title":"A comparison of third-generation semi-invasive arterial waveform analysis with thermodilution in patients undergoing coronary surgery","volume":"2012","author":"Broch","year":"2012","journal-title":"Sci World J"},{"key":"10.1016\/j.bja.2026.04.045_bib59","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1007\/s10877-012-9341-5","article-title":"Arterial pressure waveform derived cardiac output FloTrac\/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output","volume":"26","author":"Vasdev","year":"2012","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib60","doi-asserted-by":"crossref","first-page":"99","DOI":"10.4103\/2152-7806.100195","article-title":"Performance of third-generation FloTrac\/Vigileo system during hyperdynamic therapy for delayed cerebral ischemia after subarachnoid hemorrhage","volume":"3","author":"Mutoh","year":"2012","journal-title":"Surg Neurol Int"},{"key":"10.1016\/j.bja.2026.04.045_bib61","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1093\/bja\/aer491","article-title":"Third-generation FloTrac\/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients","volume":"108","author":"Monnet","year":"2012","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.bja.2026.04.045_bib62","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1016\/j.transproceed.2011.12.045","article-title":"Cardiac output derived from arterial pressure waveform analysis: validation of the third-generation software in patients undergoing orthotopic liver transplantation","volume":"44","author":"Tsai","year":"2012","journal-title":"Transplant Proc"},{"key":"10.1016\/j.bja.2026.04.045_bib63","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1007\/s10877-012-9410-9","article-title":"Cardiac output measured by uncalibrated arterial pressure waveform analysis by recently released software version 3.02 versus thermodilution in septic shock","volume":"27","author":"Slagt","year":"2013","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib64","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1213\/ANE.0b013e31827fe77e","article-title":"The influence of prone positioning on the accuracy of calibrated and uncalibrated pulse contour-derived cardiac index measurements","volume":"116","author":"Grensemann","year":"2013","journal-title":"Anesth Analg"},{"key":"10.1016\/j.bja.2026.04.045_bib65","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1093\/bja\/aet022","article-title":"Systemic vascular resistance has an impact on the reliability of the Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes","volume":"111","author":"Suehiro","year":"2013","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.bja.2026.04.045_bib66","doi-asserted-by":"crossref","first-page":"1108","DOI":"10.1053\/j.jvca.2013.02.016","article-title":"Cardiac index assessment by the pressure recording analytic method in critically ill unstable patients after cardiac surgery","volume":"27","author":"Barile","year":"2013","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.bja.2026.04.045_bib67","doi-asserted-by":"crossref","first-page":"1122","DOI":"10.1053\/j.jvca.2013.03.008","article-title":"Ability of the third-generation FloTrac\/Vigileo software to track changes in cardiac output in cardiac surgery patients: a polar plot approach","volume":"27","author":"Desebbe","year":"2013","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.bja.2026.04.045_bib68","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1007\/s10877-013-9431-z","article-title":"Cardiac output monitoring in septic shock: evaluation of the third-generation Flotrac-Vigileo","volume":"27","author":"Marqu\u00e9","year":"2013","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib69","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1007\/s10877-013-9481-2","article-title":"The impact of systemic vascular resistance on the accuracy of the FloTrac\/Vigileo\u2122 system in the perioperative period of cardiac surgery: a prospective observational comparison study","volume":"27","author":"Sotomi","year":"2013","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib70","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1016\/j.jcrc.2013.11.003","article-title":"Thermodilution vs pressure recording analytical method in hemodynamic stabilized patients","volume":"29","author":"Donati","year":"2014","journal-title":"J Crit Care"},{"key":"10.1016\/j.bja.2026.04.045_bib71","doi-asserted-by":"crossref","first-page":"1024","DOI":"10.1093\/bja\/aet489","article-title":"Validation of cardiac output monitoring based on uncalibrated pulse contour analysis vs transpulmonary thermodilution during off-pump coronary artery bypass grafting","volume":"112","author":"Smetkin","year":"2014","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.bja.2026.04.045_bib72","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1053\/j.jvca.2013.12.027","article-title":"Uncalibrated continuous cardiac output measurement in liver transplant patients: LiDCOrapid system versus pulmonary artery catheter","volume":"28","author":"Costa","year":"2014","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"Suppl. 1","key":"10.1016\/j.bja.2026.04.045_bib73","first-page":"S55","article-title":"Clinical validation of pulse contour and pulse wave transit time-based continuous cardiac output analyses in Thai patients undergoing cardiac surgery","volume":"97","author":"Wacharasint","year":"2014","journal-title":"J Med Assoc Thai"},{"key":"10.1016\/j.bja.2026.04.045_bib74","first-page":"314","article-title":"Validation of cardiac output studies from the Mostcare compared to a pulmonary artery catheter in septic patients","volume":"80","author":"Gopal","year":"2014","journal-title":"Minerva Anestesiol"},{"key":"10.1016\/j.bja.2026.04.045_bib75","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1097\/EJA.0000000000000173","article-title":"Calibrated versus uncalibrated arterial pressure waveform analysis in monitoring cardiac output with transpulmonary thermodilution in patients with severe sepsis and septic shock: an observational study","volume":"32","author":"Slagt","year":"2015","journal-title":"Eur J Anaesthesiol"},{"key":"10.1016\/j.bja.2026.04.045_bib76","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1053\/j.jvca.2014.07.022","article-title":"Improved performance of the fourth-generation FloTrac\/Vigileo system for tracking cardiac output changes","volume":"29","author":"Suehiro","year":"2015","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.bja.2026.04.045_bib77","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1097\/EJA.0000000000000160","article-title":"Arterial pressure waveform analysis versus thermodilution cardiac output measurement during open abdominal aortic aneurysm repair: a prospective observational study","volume":"32","author":"Montenij","year":"2015","journal-title":"Eur J Anaesthesiol"},{"key":"10.1016\/j.bja.2026.04.045_bib78","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1186\/s12871-015-0153-2","article-title":"Accuracy of an autocalibrated pulse contour analysis in cardiac surgery patients: a bi-center clinical trial","volume":"15","author":"Broch","year":"2015","journal-title":"BMC Anesthesiol"},{"key":"10.1016\/j.bja.2026.04.045_bib79","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1093\/bja\/aeu375","article-title":"Comparison of pulse contour analysis by Pulsioflex and Vigileo to measure and track changes of cardiac output in critically ill patients","volume":"114","author":"Monnet","year":"2015","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.bja.2026.04.045_bib80","doi-asserted-by":"crossref","first-page":"1170","DOI":"10.1016\/j.transproceed.2015.12.070","article-title":"Cardiac output assessed by the fourth-generation arterial waveform analysis system is unreliable in liver transplant recipients","volume":"48","author":"Shih","year":"2016","journal-title":"Transplant Proc"},{"key":"10.1016\/j.bja.2026.04.045_bib81","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1177\/0885066614530085","article-title":"Two methods of hemodynamic and volume status assessment in critically ill patients: a study of disagreement","volume":"31","author":"Eiferman","year":"2016","journal-title":"J Intensive Care Med"},{"key":"10.1016\/j.bja.2026.04.045_bib82","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1177\/0310057X1604400407","article-title":"Comparison of PulsioFlex\u00ae uncalibrated pulse contour method and a modified Fick principle with transpulmonary thermodilution measurements in critically ill patients","volume":"44","author":"Grensemann","year":"2016","journal-title":"Anaesth Intensive Care"},{"key":"10.1016\/j.bja.2026.04.045_bib83","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1053\/j.jvca.2015.07.022","article-title":"Accuracy, precision, and trending ability of uncalibrated arterial pressure waveform analysis of cardiac output in patients with impaired left ventricular function: a prospective, observational study","volume":"30","author":"Montenij","year":"2016","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.bja.2026.04.045_bib84","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1007\/s10877-015-9672-0","article-title":"Continuous cardiac output measurement by un-calibrated pulse wave analysis and pulmonary artery catheter in patients with septic shock","volume":"30","author":"Ganter","year":"2016","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib85","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1007\/s10877-015-9741-4","article-title":"Comparison of an advanced minimally invasive cardiac output monitoring with a continuous invasive cardiac output monitoring during lung transplantation","volume":"30","author":"Tomasi","year":"2016","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib86","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1007\/s10877-015-9772-x","article-title":"Comparison of the ability of two continuous cardiac output monitors to measure trends in cardiac output: estimated continuous cardiac output measured by modified pulse wave transit time and an arterial pulse contour-based cardiac output device","volume":"30","author":"Terada","year":"2016","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib87","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1007\/s10877-015-9784-6","volume":"30","author":"Cho","year":"2016","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib88","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1186\/s12871-017-0334-2","article-title":"The value of arterial pressure waveform cardiac output measurements in the radial and femoral artery in major cardiac surgery patients","volume":"17","author":"van Drumpt","year":"2017","journal-title":"BMC Anesthesiol"},{"key":"10.1016\/j.bja.2026.04.045_bib89","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1097\/EJA.0000000000000699","article-title":"Validation of radial artery-based uncalibrated pulse contour method (PulsioFlex) in critically ill patients: a observational study","volume":"34","author":"Grensemann","year":"2017","journal-title":"Eur J Anaesthesiol"},{"key":"10.1016\/j.bja.2026.04.045_bib90","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1007\/s10877-016-9896-7","article-title":"Reliability of cardiac output measurements using LiDCOrapid \u2122 and FloTrac\/Vigileo\u2122 across broad ranges of cardiac output values","volume":"31","author":"Asamoto","year":"2017","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib91","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1213\/ANE.0000000000001591","article-title":"Impact of systemic vascular resistance on the accuracy of the Pulsioflex device","volume":"124","author":"Biais","year":"2017","journal-title":"Anesth Analg"},{"key":"10.1016\/j.bja.2026.04.045_bib92","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1007\/s10877-016-9840-x","article-title":"Agreement in hemodynamic monitoring during orthotopic liver transplantation: a comparison of FloTrac\/Vigileo at two monitoring sites with pulmonary artery catheter thermodilution","volume":"31","author":"Lee","year":"2017","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib93","first-page":"89","article-title":"Assessment of method agreement between two minimally invasive hemodynamic measurements in septic shock patients on high doses of vasopressor drugs. A preliminary study","volume":"24","author":"Antal","year":"2017","journal-title":"Rom J Anaesth Intensive Care"},{"key":"10.1016\/j.bja.2026.04.045_bib94","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1007\/s10877-017-9983-4","article-title":"Cross-comparisons of trending accuracies of continuous cardiac-output measurements: pulse contour analysis, bioreactance, and pulmonary-artery catheter","volume":"32","author":"Lamia","year":"2018","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib95","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1053\/j.jvca.2017.09.006","article-title":"Accuracy, precision, and trending of 4 pulse wave analysis techniques in the postoperative period","volume":"32","author":"Geisen","year":"2018","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.bja.2026.04.045_bib96","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1007\/s10877-017-0071-6","article-title":"Evaluation of the use of the fourth version FloTrac system in cardiac output measurement before and after cardiopulmonary bypass","volume":"32","author":"Lin","year":"2018","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib97","doi-asserted-by":"crossref","first-page":"1230","DOI":"10.1053\/j.jvca.2018.09.015","article-title":"Accuracy and trending ability of the fourth-generation FloTrac\/EV1000 system in patients with severe aortic valve stenosis before and after surgical valve replacement","volume":"33","author":"Eisenried","year":"2019","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.bja.2026.04.045_bib98","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1007\/s10877-018-0217-1","article-title":"The accuracy and trending ability of cardiac index measured by the fourth-generation FloTrac\/Vigileo system\u2122 and the Fick method in cardiac surgery patients","volume":"33","author":"Maeda","year":"2019","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib99","doi-asserted-by":"crossref","first-page":"953","DOI":"10.1053\/j.jvca.2018.06.017","article-title":"Evaluation of the fourth-generation FloTrac\/Vigileo system in comparison with the intermittent bolus thermodilution method in patients undergoing cardiac surgery","volume":"33","author":"Kusaka","year":"2019","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.bja.2026.04.045_bib100","doi-asserted-by":"crossref","first-page":"860","DOI":"10.3906\/sag-1909-58","article-title":"Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients","volume":"50","author":"Khwannimit","year":"2020","journal-title":"Turk J Med Sci"},{"key":"10.1016\/j.bja.2026.04.045_bib101","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1007\/s10877-019-00375-z","volume":"34","author":"Saugel","year":"2020","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib102","doi-asserted-by":"crossref","first-page":"920","DOI":"10.1097\/EJA.0000000000001227","article-title":"Cardiac output estimation by pulse wave analysis using the pressure recording analytical method and intermittent pulmonary artery thermodilution: a method comparison study after off-pump coronary artery bypass surgery","volume":"37","author":"Greiwe","year":"2020","journal-title":"Eur J Anaesthesiol"},{"key":"10.1016\/j.bja.2026.04.045_bib103","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1007\/s10877-019-00374-0","volume":"34","author":"Greiwe","year":"2020","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib104","doi-asserted-by":"crossref","first-page":"120","DOI":"10.4097\/kja.20202","article-title":"Four different methods of measuring cardiac index during cytoreductive surgery and hyperthermic intraperitoneal chemotherapy","volume":"74","author":"Heijne","year":"2021","journal-title":"Korean J Anesthesiol"},{"key":"10.1016\/j.bja.2026.04.045_bib105","doi-asserted-by":"crossref","first-page":"514","DOI":"10.1053\/j.jvca.2020.03.048","article-title":"Comparing the mutual interchangeability of ECOM, FloTrac\/Vigileo, 3D-TEE, and ITD-PAC cardiac output measuring systems in coronary artery bypass grafting","volume":"35","author":"Milam","year":"2021","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.bja.2026.04.045_bib106","doi-asserted-by":"crossref","first-page":"213","DOI":"10.3390\/jcm10020213","article-title":"Cardiac output evaluation on septic shock patients: comparison between calibrated and uncalibrated devices during vasopressor therapy","volume":"10","author":"Persona","year":"2021","journal-title":"J Clin Med"},{"key":"10.1016\/j.bja.2026.04.045_bib107","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1186\/s12871-021-01415-5","article-title":"Comparison of accuracy of two uncalibrated pulse contour cardiac output monitors in off-pump coronary artery bypass surgery patients using pulmonary artery catheter-thermodilution as a reference","volume":"21","author":"Mukkamala","year":"2021","journal-title":"BMC Anesthesiol"},{"key":"10.1016\/j.bja.2026.04.045_bib108","doi-asserted-by":"crossref","first-page":"2446","DOI":"10.1053\/j.jvca.2021.11.039","article-title":"Reliability of bioreactance and pulse-power analysis in measuring cardiac index in patients undergoing cardiac surgery with cardiopulmonary bypass","volume":"36","author":"Ylikauma","year":"2022","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.bja.2026.04.045_bib109","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1007\/s10877-021-00721-0","article-title":"Bioreactance and fourth-generation pulse contour methods in monitoring cardiac index during off-pump coronary artery bypass surgery","volume":"36","author":"Ylikauma","year":"2022","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib110","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-022-14988-z","article-title":"Agreement between continuous cardiac output measured by the fourth-generation FloTrac\/Vigileo system and a pulmonary artery catheter in adult liver transplantation","volume":"12","author":"Murata","year":"2022","journal-title":"Sci Rep"},{"key":"10.1016\/j.bja.2026.04.045_bib111","doi-asserted-by":"crossref","first-page":"1377","DOI":"10.1053\/j.jvca.2023.04.003","article-title":"Prospective evaluation of a multibeat analysis cardiac index estimation in patients with cardiogenic shock","volume":"37","author":"Kee","year":"2023","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.bja.2026.04.045_bib112","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1007\/s10877-022-00924-z","article-title":"Agreement between cardiac output estimation by multi-beat analysis of arterial blood pressure waveforms and continuous thermodilution in post cardiac surgery intensive care unit patients","volume":"37","author":"Khanna","year":"2023","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib113","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1007\/s00380-022-02177-x","article-title":"Validation of cardiac output estimation using the fourth-generation FloTrac\/EV1000\u2122 system in patients undergoing robotic-assisted off-pump coronary artery bypass surgery","volume":"38","author":"Wu","year":"2023","journal-title":"Heart Vessels"},{"key":"10.1016\/j.bja.2026.04.045_bib114","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1186\/s13019-023-02128-1","article-title":"Study of the accuracy of a radial arterial pressure waveform cardiac output measurement device after cardiac surgery","volume":"18","author":"Ordo\u00f1ez-Rufat","year":"2023","journal-title":"J Cardiothorac Surg"},{"key":"10.1016\/j.bja.2026.04.045_bib115","doi-asserted-by":"crossref","first-page":"1143","DOI":"10.1053\/j.jvca.2023.03.019","article-title":"Accuracy of cardiac output measured by fourth-generation FloTrac and LiDCOrapid, and their characteristics regarding systemic vascular resistance in patients undergoing cardiac surgery","volume":"37","author":"Takei","year":"2023","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.bja.2026.04.045_bib116","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1186\/s12871-023-01988-3","article-title":"Reliability of bioreactance and pulse power analysis in measuring cardiac index during cytoreductive abdominal surgery with hyperthermic intraperitoneal chemotherapy (HIPEC)","volume":"23","author":"Ylikauma","year":"2023","journal-title":"BMC Anesthesiol"},{"key":"10.1016\/j.bja.2026.04.045_bib117","first-page":"1484","article-title":"Reliability of bioreactance and pulse-power analysis in measuring cardiac index during open abdominal aortic surgery","volume":"38","author":"Ronkainen","year":"2024","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1016\/j.bja.2026.04.045_bib118","doi-asserted-by":"crossref","DOI":"10.1111\/aas.70077","article-title":"Fourth generation FloTrac software pulse contour analysis for measuring and trending cardiac output: a method comparison study","volume":"69","author":"Dinesen","year":"2025","journal-title":"Acta Anaesthesiol Scand"},{"key":"10.1016\/j.bja.2026.04.045_bib119","doi-asserted-by":"crossref","first-page":"735","DOI":"10.3349\/ymj.2019.60.8.735","article-title":"Accuracy and efficacy of impedance cardiography as a non-invasive cardiac function monitor","volume":"60","author":"Kim","year":"2019","journal-title":"Yonsei Med J"},{"key":"10.1016\/j.bja.2026.04.045_bib120","doi-asserted-by":"crossref","first-page":"6093","DOI":"10.3390\/jcm11206093","article-title":"Comparison between fourth-generation FloTrac\/Vigileo system and continuous thermodilution technique for cardiac output estimation after time adjustment during off-pump coronary artery bypass graft surgery: a retrospective cohort study","volume":"11","author":"Oh","year":"2022","journal-title":"J Clin Med"},{"key":"10.1016\/j.bja.2026.04.045_bib121","doi-asserted-by":"crossref","first-page":"135","DOI":"10.5152\/TJAR.2021.1356","article-title":"Correlation of cardiac output by arterial contour-derived cardiac output monitor versus pulmonary artery catheter in liver transplant: experience at an Indian center","volume":"50","author":"Halemani","year":"2022","journal-title":"Turk J Anaesthesiol Reanim"},{"key":"10.1016\/j.bja.2026.04.045_bib122","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1023\/A:1009982611386","article-title":"A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques","volume":"15","author":"Critchley","year":"1999","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib123","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1097\/EJA.0000000000001469","article-title":"Agreement between continuous noninvasive finger cuff-derived and invasive arterial blood pressure measurements: effect of data sampling and data processing","volume":"38","author":"Flick","year":"2021","journal-title":"Eur J Anaesthesiol"},{"key":"10.1016\/j.bja.2026.04.045_bib124","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1186\/s13054-017-1739-5","article-title":"Transpulmonary thermodilution: advantages and limits","volume":"21","author":"Monnet","year":"2017","journal-title":"Crit Care"},{"key":"10.1016\/j.bja.2026.04.045_bib125","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1186\/cc7129","article-title":"Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies--with specific reference to the measurement of cardiac output","volume":"13","author":"Cecconi","year":"2009","journal-title":"Crit Care"},{"key":"10.1016\/j.bja.2026.04.045_bib126","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1007\/s10877-015-9711-x","article-title":"Cardiac output method comparison studies: the relation of the precision of agreement and the precision of method","volume":"30","author":"Hapfelmeier","year":"2016","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.bja.2026.04.045_bib127","article-title":"Cardiac output-guided haemodynamic therapy for patients undergoing major gastrointestinal surgery: OPTIMISE II randomised clinical trial","volume":"387","year":"2024","journal-title":"BMJ"},{"key":"10.1016\/j.bja.2026.04.045_bib128","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1016\/j.bja.2024.03.040","article-title":"Cardiac index-guided therapy to maintain optimised postinduction cardiac index in high-risk patients having major open abdominal surgery: the multicentre randomised iPEGASUS trial","volume":"133","author":"Funcke","year":"2024","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.bja.2026.04.045_bib129","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1016\/j.bja.2021.10.046","article-title":"Goal-directed haemodynamic therapy during general anaesthesia for noncardiac surgery: a systematic review and meta-analysis","volume":"128","author":"Jessen","year":"2022","journal-title":"Br J Anaesth"}],"container-title":["British Journal of Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0007091226003296?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0007091226003296?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T13:32:43Z","timestamp":1786714363000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0007091226003296"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":129,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,7]]}},"alternative-id":["S0007091226003296"],"URL":"https:\/\/doi.org\/10.1016\/j.bja.2026.04.045","relation":{},"ISSN":["0007-0912"],"issn-type":[{"value":"0007-0912","type":"print"}],"subject":[],"published":{"date-parts":[[2026,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Agreement of minimally invasive pulse wave analysis with pulmonary artery and transpulmonary thermodilution cardiac output measurements in perioperative and intensive care medicine: a systematic review and meta-analysis","name":"articletitle","label":"Article Title"},{"value":"British Journal of Anaesthesia","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.bja.2026.04.045","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Author(s). Published by Elsevier Ltd on behalf of British Journal of Anaesthesia.","name":"copyright","label":"Copyright"}]}}