{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T01:22:09Z","timestamp":1767144129677,"version":"build-2238731810"},"reference-count":24,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2023,12,1]],"date-time":"2023-12-01T00:00:00Z","timestamp":1701388800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,10,3]],"date-time":"2023-10-03T00:00:00Z","timestamp":1696291200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["1K01HL150318"],"award-info":[{"award-number":["1K01HL150318"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["bjaopen.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["BJA Open"],"published-print":{"date-parts":[[2023,12]]},"DOI":"10.1016\/j.bjao.2023.100236","type":"journal-article","created":{"date-parts":[[2023,11,2]],"date-time":"2023-11-02T20:39:10Z","timestamp":1698957550000},"page":"100236","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"special_numbering":"C","title":["Validation of a convolutional neural network that reliably identifies electromyographic compound motor action potentials following train-of-four stimulation: an algorithm development experimental study"],"prefix":"10.1016","volume":"8","author":[{"given":"Richard H.","family":"Epstein","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9523-697X","authenticated-orcid":false,"given":"Olivia F.","family":"Perez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ira S.","family":"Hofer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9389-6413","authenticated-orcid":false,"given":"J Ross","family":"Renew","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R\u00e9ka","family":"Nemes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sorin J.","family":"Brull","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.bjao.2023.100236_bib1","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1097\/ALN.0000000000004379","article-title":"American Society of Anesthesiologists practice guidelines for monitoring and antagonism of neuromuscular blockade: a report by the American Society of Anesthesiologists task force on neuromuscular blockade","volume":"138","author":"Thilen","year":"2023","journal-title":"Anesthesiology"},{"key":"10.1016\/j.bjao.2023.100236_bib2","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1097\/EJA.0000000000001769","article-title":"Peri-operative management of neuromuscular blockade: a guideline from the European society of Anaesthesiology and intensive care","volume":"40","author":"Fuchs-Buder","year":"2023","journal-title":"Eur J Anaesthesiol"},{"key":"10.1016\/j.bjao.2023.100236_bib3","doi-asserted-by":"crossref","first-page":"1296","DOI":"10.1093\/bja\/58.11.1296","article-title":"Reappearance of the train-of-four after neuromuscular blockade induced with tubocurarine, vecuronium or atracurium","volume":"58","author":"O'Hara","year":"1986","journal-title":"Br J Anaesth"},{"issue":"Suppl 1","key":"10.1016\/j.bjao.2023.100236_bib4","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1111\/anae.13738","article-title":"Conceptual and technical insights into the basis of neuromuscular monitoring","volume":"72","author":"Naguib","year":"2017","journal-title":"Anaesthesia"},{"key":"10.1016\/j.bjao.2023.100236_bib5","doi-asserted-by":"crossref","first-page":"48","DOI":"10.3109\/03093640309167976","article-title":"The effect of subcutaneous fat on myoelectric signal amplitude and cross-talk","volume":"27","author":"Kuiken","year":"2003","journal-title":"Prosthet Orthot Int"},{"key":"10.1016\/j.bjao.2023.100236_bib6","doi-asserted-by":"crossref","first-page":"1089","DOI":"10.1007\/s12630-015-0433-9","article-title":"Comparison of train-of-four count by anesthesia providers versus TOF-Watch\u00ae SX: a prospective cohort study","volume":"62","author":"Bhananker","year":"2015","journal-title":"Can J Anaesth"},{"key":"10.1016\/j.bjao.2023.100236_bib7","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1016\/j.bja.2020.02.022","article-title":"Counting train-of-four twitch response: comparison of palpation to mechanomyography, acceleromyography, and electromyography","volume":"124","author":"Bowdle","year":"2020","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.bjao.2023.100236_bib8","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1111\/j.1365-2044.1993.tb06947.x","article-title":"The level of neuromuscular block needed to suppress diaphragmatic movement during tracheal suction in patients with raised intracranial pressure: a study with vecuronium and atracurium","volume":"48","author":"Werba","year":"1993","journal-title":"Anaesthesia"},{"key":"10.1016\/j.bjao.2023.100236_bib9","doi-asserted-by":"crossref","first-page":"555","DOI":"10.2991\/ijcis.2017.10.1.38","article-title":"A\u00a0snapshot of image pre-processing for convolutional neural networks: case study of MNIST","volume":"10","author":"Tabik","year":"2017","journal-title":"Int J Comput Intell Syst"},{"key":"10.1016\/j.bjao.2023.100236_bib10","author":"Bossuyt"},{"key":"10.1016\/j.bjao.2023.100236_bib11","series-title":"Annual Meeting of the American Society of Anesthesiologists","first-page":"A2069","article-title":"Electromyographic and acceleromyographic monitoring in restricted arm movement surgical setting: a prospective, randomized trial","author":"Hernandez","year":"2021"},{"key":"10.1016\/j.bjao.2023.100236_bib12","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1097\/ALN.0000000000003896","article-title":"Ipsilateral and simultaneous comparison of responses from acceleromyography- and electromyography-based neuromuscular monitors","volume":"135","author":"Nemes","year":"2021","journal-title":"Anesthesiology"},{"key":"10.1016\/j.bjao.2023.100236_bib13","author":"Chollet"},{"key":"10.1016\/j.bjao.2023.100236_bib14","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1109\/MSP.2012.2211477","article-title":"The MNIST database of handwritten digit images for machine learning research","volume":"29","author":"Deng","year":"2012","journal-title":"IEEE Signal Process Mag"},{"key":"10.1016\/j.bjao.2023.100236_bib15","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1093\/ckj\/sfaa188","article-title":"External validation of prognostic models: what, why, how, when and where?","volume":"14","author":"Ramspek","year":"2021","journal-title":"Clin Kidney J"},{"key":"10.1016\/j.bjao.2023.100236_bib16","series-title":"Anesthesia equipment: principles and Applications","first-page":"297","article-title":"Neuromuscular block monitoring","author":"Brull","year":"1993"},{"key":"10.1016\/j.bjao.2023.100236_bib17","doi-asserted-by":"crossref","first-page":"257","DOI":"10.5201\/ipol.2015.137","article-title":"A\u00a0fast C++ implementation of neural network backpropagation training algorithm: application to Bayesian optimal image demosaicing","volume":"5","author":"Wang","year":"2015","journal-title":"IPOL"},{"key":"10.1016\/j.bjao.2023.100236_bib18","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1097\/00000542-198510000-00015","article-title":"Tactile and visual evaluation of the response to train-of-four nerve stimulation","volume":"63","author":"Viby-Mogensen","year":"1985","journal-title":"Anesthesiology"},{"key":"10.1016\/j.bjao.2023.100236_bib19","doi-asserted-by":"crossref","first-page":"352","DOI":"10.1213\/00000539-199308000-00024","article-title":"Visual and tactile assessment of neuromuscular fade","volume":"77","author":"Brull","year":"1993","journal-title":"Anesth Analg"},{"key":"10.1016\/j.bjao.2023.100236_bib20","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1213\/00000539-198707000-00009","article-title":"Relationship between single twitch depression and train-of-four fade","volume":"66","author":"Power","year":"1987","journal-title":"Anesth Analg"},{"key":"10.1016\/j.bjao.2023.100236_bib21","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1109\/TBME.1987.326069","article-title":"A\u00a0model-based self-adjusting two-phase controller for vecuronium-induced muscle relaxation during anesthesia","volume":"34","author":"Jaklitsch","year":"1987","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1016\/j.bjao.2023.100236_bib22","doi-asserted-by":"crossref","first-page":"1112","DOI":"10.1111\/j.1365-2044.2011.06875.x","article-title":"Clinical evaluation of a simultaneous closed-loop anaesthesia control system for depth of anaesthesia and neuromuscular blockade","volume":"66","author":"Janda","year":"2011","journal-title":"Anaesthesia"},{"key":"10.1016\/j.bjao.2023.100236_bib23","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1097\/ALN.0000000000001409","article-title":"Current status of neuromuscular reversal and monitoring: challenges and opportunities","volume":"126","author":"Brull","year":"2017","journal-title":"Anesthesiology"},{"key":"10.1016\/j.bjao.2023.100236_bib24","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pmed.1001221","article-title":"Reporting and methods in clinical prediction research: a systematic review","volume":"9","author":"Bouwmeester","year":"2012","journal-title":"PLOS Med"}],"updated-by":[{"DOI":"10.1016\/j.bjao.2024.100266","type":"erratum","label":"Erratum","source":"publisher","updated":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T00:00:00Z","timestamp":1709251200000}}],"container-title":["BJA Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2772609623001156?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2772609623001156?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,1,6]],"date-time":"2024-01-06T19:34:13Z","timestamp":1704569653000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2772609623001156"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12]]},"references-count":24,"alternative-id":["S2772609623001156"],"URL":"https:\/\/doi.org\/10.1016\/j.bjao.2023.100236","relation":{},"ISSN":["2772-6096"],"issn-type":[{"value":"2772-6096","type":"print"}],"subject":[],"published":{"date-parts":[[2023,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Validation of a convolutional neural network that reliably identifies electromyographic compound motor action potentials following train-of-four stimulation: an algorithm development experimental study","name":"articletitle","label":"Article Title"},{"value":"BJA Open","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.bjao.2023.100236","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Authors. Published by Elsevier Ltd on behalf of British Journal of Anaesthesia.","name":"copyright","label":"Copyright"}],"article-number":"100236"}}