{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T14:51:27Z","timestamp":1761663087207},"reference-count":24,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2013,6,1]],"date-time":"2013-06-01T00:00:00Z","timestamp":1370044800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["British Journal of Oral and Maxillofacial Surgery"],"published-print":{"date-parts":[[2013,6]]},"DOI":"10.1016\/j.bjoms.2012.06.007","type":"journal-article","created":{"date-parts":[[2012,7,9]],"date-time":"2012-07-09T05:01:57Z","timestamp":1341810117000},"page":"307-311","source":"Crossref","is-referenced-by-count":9,"title":["Risk factors for breakage of biodegradable plate systems after bilateral sagittal split mandibular setback surgery"],"prefix":"10.1016","volume":"51","author":[{"given":"Izumi","family":"Yoshioka","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kaori","family":"Igawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jyunko","family":"Nagata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maho","family":"Yoshida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takashi","family":"Baba","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takeshi","family":"Ichiki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yudai","family":"Kondoh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koichi","family":"Takamori","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koji","family":"Kashima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sumio","family":"Sakoda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.bjoms.2012.06.007_bib0005","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1097\/00001665-199805000-00005","article-title":"Resorbable fixation of Le Fort I osteotomies","volume":"9","author":"Edwards","year":"1998","journal-title":"J Craniofac Surg"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0010","doi-asserted-by":"crossref","first-page":"2148","DOI":"10.1016\/j.joms.2007.04.010","article-title":"Mechanical strength and stiffness of biodegradable and titanium osteofixation systems","volume":"65","author":"Buijs","year":"2007","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0015","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1097\/00003086-200002000-00026","article-title":"Adverse tissue reactions to bioabsorbable fixation devices","volume":"371","author":"Bostman","year":"2000","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0020","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1302\/0301-620X.72B4.2199452","article-title":"Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers","volume":"72 B","author":"Bostman","year":"1990","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0025","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/0142-9612(95)91092-D","article-title":"Late degradation tissue response to poly(l-lactide) bone plates and screws","volume":"16","author":"Bergsma","year":"1995","journal-title":"Biomaterials"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0030","doi-asserted-by":"crossref","first-page":"666","DOI":"10.1016\/S0278-2391(10)80267-8","article-title":"Foreign body reactions to resorbable poly(l-lactide) bone plates and screws used for the fixation of unstable zygomatic fractures","volume":"51","author":"Bergsma","year":"1993","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0035","doi-asserted-by":"crossref","first-page":"919","DOI":"10.1016\/j.joms.2011.02.136","article-title":"Comparison of material-related complications after bilateral sagittal split mandibular setback surgery: biodegradable versus titanium miniplates","volume":"70","author":"Yoshioka","year":"2012","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0040","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.tripleo.2006.12.016","article-title":"Evaluation of different miniplates in fixation of fractured human mandible with the finite element method","volume":"103","author":"Korkmaz","year":"2007","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0045","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1093\/ejo\/cji029","article-title":"The relationship between temporomandibular joint disc morphology and stress angulation in skeletal Class III patients","volume":"27","author":"Ueki","year":"2005","journal-title":"Eur J Orthod"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0050","first-page":"943","article-title":"The Kostecka osteotomy and its modification","volume":"21","author":"Dal Pont","year":"1966","journal-title":"Riv Ital Stomatol"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0055","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/S0889-5406(96)70161-0","article-title":"Soft tissue and dentoskeletal profile changes associated with maxillary expansion and protraction headgear treatment","volume":"109","author":"Ngan","year":"1996","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0060","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1016\/j.joms.2009.07.020","article-title":"Comparative study between resorbable and nonresorbable plates in orthognathic surgery","volume":"68","author":"Ahn","year":"2010","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0065","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1016\/j.tripleo.2004.04.017","article-title":"Assessment of material- and technique-related complications following sagittal split osteotomies stabilized by biodegradable polylactide screws","volume":"99","author":"Kallela","year":"2005","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0070","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1016\/S0278-2391(98)90461-X","article-title":"A 5-year in vitro and in vivo study of the biodegradation of polylactide plates","volume":"56","author":"Suuronen","year":"1998","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0075","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1053\/joms.2001.19264","article-title":"Minimizing displacement of the proximal segment after bilateral sagittal split ramus osteotomy in asymmetric cases","volume":"59","author":"Yoshida","year":"2001","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0080","doi-asserted-by":"crossref","first-page":"2125","DOI":"10.1016\/j.joms.2007.02.005","article-title":"A method to passively align the sagittal ramus osteotomy segments","volume":"65","author":"Ellis","year":"2007","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0085","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.tripleo.2009.12.049","article-title":"Interferences between mandibular proximal and distal segments in orthognathic surgery for patients with asymmetric mandibular prognathism depending on different osteotomy techniques","volume":"110","author":"Yang","year":"2010","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0090","doi-asserted-by":"crossref","first-page":"2528","DOI":"10.1016\/j.joms.2009.06.022","article-title":"Malocclusions resulting from loss of fixation after sagittal split ramus osteotomies","volume":"67","author":"Ellis","year":"2009","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0095","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1007\/s10006-011-0266-9","article-title":"In vitro biomechanical evaluation of the effect of an additional L-shaped plate on straight or box plate fixation in sagittal split ramus osteotomy using a bioabsorbable plate system","volume":"15","author":"Matsushita","year":"2011","journal-title":"Oral Maxillofac Surg"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0100","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1067\/moe.2002.122160","article-title":"The use of bioabsorbable osteofixation devices in craniomaxillofacial surgery","volume":"94","author":"Peltoniemi","year":"2002","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0105","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1016\/S1010-5182(98)80069-3","article-title":"Biodegradable self-reinforced poly-l\/dl-lactide plates and screws in bimaxillary orthognathic surgery: short term skeletal stability and material related failures","volume":"26","author":"Haers","year":"1998","journal-title":"J Craniomaxillofac Surg"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0110","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1006\/ijom.2003.0510","article-title":"Are there any complications with bioabsorbable fixation devices? A 10 year review in orthognathic surgery","volume":"33","author":"Laine","year":"2004","journal-title":"Int J Oral Maxillofac Surg"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0115","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1016\/j.jcms.2010.01.002","article-title":"Resorbable versus titanium osteosynthesis devices in bilateral sagittal split ramus osteotomy of the mandible \u2013 the results of a two centre randomised clinical study with an eight-year follow-up","volume":"38","author":"Stockmann","year":"2010","journal-title":"J Craniomaxillofac Surg"},{"key":"10.1016\/j.bjoms.2012.06.007_bib0120","doi-asserted-by":"crossref","first-page":"1059","DOI":"10.1016\/j.ijom.2010.07.012","article-title":"Comparison of the stability of bioabsorbable and titanium osteosynthesis materials for rigid internal fixation in orthognathic surgery. A prospective randomized controlled study in 101 patients with 192 osteotomies","volume":"39","author":"Tuovinen","year":"2010","journal-title":"Int J Oral Maxillofac Surg"}],"container-title":["British Journal of Oral and Maxillofacial Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0266435612004548?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0266435612004548?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,6,30]],"date-time":"2019-06-30T18:23:35Z","timestamp":1561919015000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0266435612004548"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,6]]},"references-count":24,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2013,6]]}},"alternative-id":["S0266435612004548"],"URL":"https:\/\/doi.org\/10.1016\/j.bjoms.2012.06.007","relation":{},"ISSN":["0266-4356"],"issn-type":[{"value":"0266-4356","type":"print"}],"subject":[],"published":{"date-parts":[[2013,6]]}}}