{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T17:11:54Z","timestamp":1790442714572,"version":"4.1.0"},"reference-count":21,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2015,3,1]],"date-time":"2015-03-01T00:00:00Z","timestamp":1425168000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["British Journal of Oral and Maxillofacial Surgery"],"published-print":{"date-parts":[[2015,3]]},"DOI":"10.1016\/j.bjoms.2014.11.010","type":"journal-article","created":{"date-parts":[[2015,1,20]],"date-time":"2015-01-20T14:00:55Z","timestamp":1421762455000},"page":"223-229","source":"Crossref","is-referenced-by-count":25,"title":["Comparison of miniplates and biodegradable plates in reconstruction of the mandible with a fibular free flap"],"prefix":"10.1016","volume":"53","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8702-8169","authenticated-orcid":false,"given":"N.K.","family":"Kim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W.","family":"Nam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H.J.","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.bjoms.2014.11.010_bib0005","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.oraloncology.2009.11.006","article-title":"Contemporary reconstruction of the mandible","volume":"46","author":"Bak","year":"2010","journal-title":"Oral Oncol"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0010","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1016\/S0194-5998(99)70226-3","article-title":"Assessment of plate use for mandibular reconstruction: has changing technology made a difference?","volume":"121","author":"Klotch","year":"1999","journal-title":"Otolaryngol Head Neck Surg"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0015","doi-asserted-by":"crossref","first-page":"1733","DOI":"10.1097\/PRS.0b013e31818a9ac5","article-title":"Comparison of miniplates and reconstruction plates in fibular flap reconstruction of the mandible","volume":"122","author":"Robey","year":"2008","journal-title":"Plast Reconstr Surg"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0020","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1001\/archotol.1995.01890010056010","article-title":"Rigid fixation of vascularized bone grafts in mandibular reconstruction","volume":"121","author":"Futran","year":"1995","journal-title":"Arch Otolaryngol Head Neck Surg"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0025","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/1097-0347(200101)23:1<1::AID-HED1>3.0.CO;2-2","article-title":"Fixation methods in mandibular reconstruction using fibula grafts: a comparative study into the relative strength of three different types of osteosynthesis","volume":"23","author":"Strackee","year":"2001","journal-title":"Head Neck"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0030","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1097\/00006534-199302000-00010","article-title":"Fixation of the vascularized bone graft in mandibular reconstruction","volume":"91","author":"Boyd","year":"1993","journal-title":"Plast Reconstr Surg"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0035","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1097\/00000637-198912000-00005","article-title":"Titanium miniplate fixation in free flap mandible reconstruction","volume":"23","author":"Hidalgo","year":"1989","journal-title":"Ann Plast Surg"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0110","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1002\/hed.10343","article-title":"Comparison of miniplates and reconstruction plates in mandibular reconstruction","volume":"26","author":"Shaw","year":"2004","journal-title":"Head Neck"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0045","first-page":"393","article-title":"Fracture reduction using a biodegradable material, polylactic acid","volume":"29","author":"Cutright","year":"1971","journal-title":"J Oral Surg"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0050","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/j.joms.2005.10.055","article-title":"Resorbable plates for the fixation of mandibular fractures: a prospective study","volume":"65","author":"Laughlin","year":"2007","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0055","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.jcms.2011.01.011","article-title":"Skeletal stability and morbidity with self-reinforced P (L\/DL) LA resorbable osteosynthesis in bimaxillary orthognathic surgery","volume":"40","author":"Moure","year":"2012","journal-title":"J Craniomaxillofac Surg"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0060","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1016\/j.ijom.2010.11.024","article-title":"Biodegradable fixation for craniomaxillofacial surgery: a 10-year experience involving 761 operations and 745 patients","volume":"40","author":"Turvey","year":"2011","journal-title":"Int J Oral Maxillofac Surg"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0065","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.ajodo.2006.04.049","article-title":"Comparison of titanium and resorbable copolymer fixation after Le Fort 1 maxillary impaction","volume":"134","author":"Dhol","year":"2008","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0070","doi-asserted-by":"crossref","first-page":"1080","DOI":"10.1097\/PRS.0b013e31822b6723","article-title":"Use of virtual surgery and stereolithography-guided osteotomy for mandibular reconstruction with the free fibula","volume":"128","author":"Antony","year":"2011","journal-title":"Plast Reconstr Surg"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0075","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1097\/01.prs.0000233211.54505.9a","article-title":"Oromandibular reconstruction using a fibula osteocutaneous free flap: four different \u201cpreplating\u201d techniques","volume":"118","author":"Marchetti","year":"2006","journal-title":"Plast Reconstr Surg"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0080","doi-asserted-by":"crossref","first-page":"2148","DOI":"10.1016\/j.joms.2007.04.010","article-title":"Mechanical strength and stiffness of biodegradable and titanium osteofixation systems","volume":"65","author":"Buijs","year":"2007","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0085","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0901-5027(89)80101-8","article-title":"Stress shielding effect of rigid internal fixation plates on mandibular bone grafts. A photon absorption densitometry and quantitative computerized tomographic evaluation","volume":"18","author":"Kennady","year":"1989","journal-title":"Int J Oral Maxillofac Surg"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0090","doi-asserted-by":"crossref","first-page":"1018","DOI":"10.1097\/00006534-199505000-00010","article-title":"The free flap and plate in oromandibular reconstruction: long-term review and indications","volume":"95","author":"Boyd","year":"1995","journal-title":"Plast Reconstr Surg"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0095","doi-asserted-by":"crossref","first-page":"1336","DOI":"10.1097\/00006534-199710000-00043","article-title":"Complications and toxicities of implantable biomaterials used in facial reconstructive and aesthetic surgery: a comprehensive review of the literature","volume":"100","author":"Rubin","year":"1997","journal-title":"Plast Reconstr Surg"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0100","doi-asserted-by":"crossref","first-page":"1905","DOI":"10.1016\/j.tiv.2010.07.023","article-title":"Titanium ion induces necrosis and sensitivity to lipopolysaccharide in gingival epithelial-like cells","volume":"24","author":"Makihira","year":"2010","journal-title":"Toxicol in vitro"},{"key":"10.1016\/j.bjoms.2014.11.010_bib0105","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/S0901-5027(05)80350-9","article-title":"Ultrastructural findings in soft tissues adjacent to titanium plates used in jaw fracture treatment","volume":"22","author":"Schliephake","year":"1993","journal-title":"Int J Oral Maxillofac Surg"}],"container-title":["British Journal of Oral and Maxillofacial Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0266435614006640?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0266435614006640?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,26]],"date-time":"2018-09-26T01:58:46Z","timestamp":1537927126000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0266435614006640"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,3]]},"references-count":21,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2015,3]]}},"alternative-id":["S0266435614006640"],"URL":"https:\/\/doi.org\/10.1016\/j.bjoms.2014.11.010","relation":{},"ISSN":["0266-4356"],"issn-type":[{"value":"0266-4356","type":"print"}],"subject":[],"published":{"date-parts":[[2015,3]]}}}