{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T09:31:41Z","timestamp":1794043901900,"version":"4.8.0"},"reference-count":28,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2022,5,1]],"date-time":"2022-05-01T00:00:00Z","timestamp":1651363200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,5,1]],"date-time":"2022-05-01T00:00:00Z","timestamp":1651363200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jprasurg.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Plastic, Reconstructive &amp; Aesthetic Surgery"],"published-print":{"date-parts":[[2022,5]]},"DOI":"10.1016\/j.bjps.2021.11.101","type":"journal-article","created":{"date-parts":[[2021,12,3]],"date-time":"2021-12-03T13:11:41Z","timestamp":1638537101000},"page":"1750-1757","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":21,"title":["Accurate reconstruction of bone defects in orbital\u2013maxillary\u2013zygomatic (OMZ) complex with polyetheretherketone (PEEK)"],"prefix":"10.1016","volume":"75","author":[{"given":"Mingming","family":"Lv","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shalva R.","family":"Gvetadze","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8490-0177","authenticated-orcid":false,"given":"Anand","family":"Gupta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jian","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"2","key":"10.1016\/j.bjps.2021.11.101_bib0001","doi-asserted-by":"crossref","first-page":"e127","DOI":"10.1097\/SCS.0000000000005031","article-title":"Application of Three-Dimensional Printing Technology for Improved Orbital-Maxillary-Zygomatic Reconstruction","volume":"30","author":"Xue","year":"2019","journal-title":"J Craniofac Surg"},{"issue":"5","key":"10.1016\/j.bjps.2021.11.101_bib0002","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1055\/s-0034-1395211","article-title":"Orbital reconstruction: prefabricated implants, data transfer, and revision surgery","volume":"30","author":"Bittermann","year":"2014","journal-title":"Facial Plast Surg"},{"issue":"8","key":"10.1016\/j.bjps.2021.11.101_bib0003","doi-asserted-by":"crossref","DOI":"10.1016\/j.joms.2017.03.054","article-title":"Reconstruction of Maxillary and Orbital Floor Defect With Free Fibula Flap and Whole Individualized Titanium Mesh Assisted by Computer Techniques","volume":"75","author":"Fu","year":"2017","journal-title":"J Oral Maxillofac Surg"},{"issue":"4","key":"10.1016\/j.bjps.2021.11.101_bib0004","doi-asserted-by":"crossref","DOI":"10.1016\/j.joms.2018.11.030","article-title":"Single-Unit 3D-Printed Titanium Reconstruction Plate for Maxillary Reconstruction: the Evolution of Surgical Reconstruction for Maxillary Defects-A Case Report and Review of Current Techniques","volume":"77","author":"Melville","year":"2019","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.bjps.2021.11.101_bib0005","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1097\/SCS.0000000000002080","article-title":"Antonyshyn OM patientspecific orbital implants: development and implementation of technology for more accurate orbital reconstruction","volume":"27","author":"Podolsky","year":"2016","journal-title":"J Craniofac Surg"},{"issue":"10","key":"10.1016\/j.bjps.2021.11.101_bib0006","doi-asserted-by":"crossref","DOI":"10.1016\/j.joms.2015.06.171","article-title":"Outcomes of orbital floor reconstruction after extensive maxillectomy using the computer-assisted fabricated individual titanium mesh technique","volume":"73","author":"Zhang","year":"2015","journal-title":"J Oral Maxillofac Surg"},{"issue":"11","key":"10.1016\/j.bjps.2021.11.101_bib0007","doi-asserted-by":"crossref","first-page":"1969","DOI":"10.1016\/j.joms.2013.03.021","article-title":"Single-step resection and reconstruction using patient-specific implants in the treatment of benign cranio-orbital tumors","volume":"71","author":"Gerbino","year":"2013","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.bjps.2021.11.101_bib0008","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1563\/AAID-JOI-D-11-00002","article-title":"PEEK dental implants: a review of the literature","volume":"39","author":"Schwitalla","year":"2013","journal-title":"J Oral Implantol"},{"key":"10.1016\/j.bjps.2021.11.101_bib0009","doi-asserted-by":"crossref","first-page":"4845","DOI":"10.1016\/j.biomaterials.2007.07.013","article-title":"PEEK biomaterials in trauma, orthopedic, and spinal implants","volume":"28","author":"Kurtz","year":"2007","journal-title":"Biomaterials"},{"key":"10.1016\/j.bjps.2021.11.101_bib0010","doi-asserted-by":"crossref","first-page":"3689","DOI":"10.1002\/jbm.a.35480","article-title":"Biomechanical and bioactivity concepts of polyetheretherketone composites for use in orthopedic implants - a review: biomechanical and bioactivity concepts of PEEK","volume":"103","author":"Abdullah","year":"2015","journal-title":"J Biomed Mater Res A"},{"issue":"8","key":"10.1016\/j.bjps.2021.11.101_bib0011","doi-asserted-by":"crossref","first-page":"1752","DOI":"10.1016\/j.joms.2016.12.031","article-title":"Drawer-Like\" Resection and Reconstruction With Titanium Mesh: a Novel Surgical Technique for Treatment of Giant Ossifying Fibroma in the Maxilla","volume":"75","author":"Lv","year":"2017","journal-title":"J Oral Maxillofac Surg"},{"issue":"7","key":"10.1016\/j.bjps.2021.11.101_bib0012","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1016\/j.jcms.2019.03.018","article-title":"The use of patient specific polyetheretherketone implants for reconstruction of maxillofacial deformities","volume":"47","author":"J\u00e4rvinen","year":"2019","journal-title":"J Craniomaxillofac Surg"},{"issue":"1","key":"10.1016\/j.bjps.2021.11.101_bib0013","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1097\/01.scs.0000249359.56417.7e","article-title":"Complex orbito-fronto-temporal reconstruction using computer-designed PEEK implant","volume":"18","author":"Scolozzi","year":"2007","journal-title":"J Craniofac Surg"},{"issue":"11","key":"10.1016\/j.bjps.2021.11.101_bib0014","doi-asserted-by":"crossref","first-page":"1609","DOI":"10.1016\/j.bjps.2018.07.016","article-title":"Custom CAD\/CAM implants for complex craniofacial reconstruction in children: our experience based on 136 cases\u2730","volume":"71","author":"Nguyen","year":"2018","journal-title":"J Plast Reconstr Aesthet Surg"},{"issue":"4","key":"10.1016\/j.bjps.2021.11.101_bib0015","first-page":"3","article-title":"Complex skull defects reconstruction with \u0421\u0410D\/\u0421\u0410\u041c titanium and polyetheretherketone (PEEK) implants. Zh Vopr Neirokhir Im N N","volume":"78","author":"Eolchiyan","year":"2014","journal-title":"Burdenko"},{"issue":"4","key":"10.1016\/j.bjps.2021.11.101_bib0016","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1007\/s11548-010-0476-x","article-title":"3D printing based on imaging data: review of medical applications","volume":"5","author":"Rengier","year":"2010","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"1","key":"10.1016\/j.bjps.2021.11.101_bib0017","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1007\/s10439-016-1668-5","article-title":"3D-Printing Technologies for Craniofacial Rehabilitation, Reconstruction, and Regeneration","volume":"45","author":"Nyberg","year":"2017","journal-title":"Ann Biomed Eng"},{"issue":"3","key":"10.1016\/j.bjps.2021.11.101_bib0018","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1007\/s10006-018-0704-z","article-title":"Use of 3-D printing technologies in craniomaxillofacial surgery: a review","volume":"22","author":"Ghai","year":"2018","journal-title":"Oral Maxillofac Surg"},{"key":"10.1016\/j.bjps.2021.11.101_bib0019","doi-asserted-by":"crossref","DOI":"10.1155\/2018\/4520636","article-title":"Patient-Specific Surgical Implants Made of 3D Printed PEEK: material, Technology, and Scope of Surgical Application","volume":"2018","author":"Honigmann","year":"2018","journal-title":"Biomed Res Int"},{"issue":"1","key":"10.1016\/j.bjps.2021.11.101_bib0020","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1001\/archfaci.11.1.53","article-title":"Use of customized polyetheretherketone (PEEK) implants in the reconstruction of complex maxillofacial defects","volume":"11","author":"Kim","year":"2009","journal-title":"Arch Facial Plast Surg"},{"issue":"6","key":"10.1016\/j.bjps.2021.11.101_bib0021","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.1089\/neu.2011.1794","article-title":"Cranioplasty with customized titanium and PEEK implants in a mechanical stress model","volume":"29","author":"Lethaus","year":"2012","journal-title":"J Neurotrauma"},{"issue":"3","key":"10.1016\/j.bjps.2021.11.101_bib0022","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1016\/j.biomaterials.2005.07.011","article-title":"Polyetheretherketone as a biomaterial for spinal applications","volume":"27","author":"Toth","year":"2006","journal-title":"Biomaterials"},{"issue":"8","key":"10.1016\/j.bjps.2021.11.101_bib0023","doi-asserted-by":"crossref","first-page":"1356","DOI":"10.1016\/j.jcms.2015.06.043","article-title":"Primary and secondary reconstruction of complex craniofacial defects using polyetheretherketone custom-made implants","volume":"43","author":"Gerbino","year":"2015","journal-title":"J Craniomaxillofac Surg"},{"issue":"7","key":"10.1016\/j.bjps.2021.11.101_bib0024","doi-asserted-by":"crossref","first-page":"1232","DOI":"10.1016\/j.jcms.2015.04.028","article-title":"Polyetheretherketone custom-made implants for craniofacial defects: report of 14 cases and review of the literature","volume":"43","author":"Alonso-Rodriguez","year":"2015","journal-title":"J Craniomaxillofac Surg"},{"issue":"2","key":"10.1016\/j.bjps.2021.11.101_bib0025","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.jobcr.2020.01.006","article-title":"Clinical efficacy of peek patient-specific implants in orbital reconstruction","volume":"10","author":"Chepurnyi","year":"2020","journal-title":"J Oral Biol Craniofac Res"},{"issue":"13","key":"10.1016\/j.bjps.2021.11.101_bib0026","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1016\/0142-9612(95)94906-2","article-title":"In vitro biocompatibility testing of polymers for orthopaedic implants using cultured fibroblasts and osteoblasts","volume":"16","author":"Morrison","year":"1995","journal-title":"Biomaterials"},{"issue":"8","key":"10.1016\/j.bjps.2021.11.101_bib0027","doi-asserted-by":"crossref","first-page":"1749","DOI":"10.1016\/S0142-9612(01)00300-3","article-title":"Polyetheretherketone\u2013cytotoxicity and mutagenicity in vitro","volume":"23","author":"Katzer","year":"2002","journal-title":"Biomaterials"},{"issue":"2","key":"10.1016\/j.bjps.2021.11.101_bib0028","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/j.wneu.2014.06.003","article-title":"Comparison of polyetheretherketone and titanium cranioplasty after decompressive craniectomy","volume":"83","author":"Thien","year":"2015","journal-title":"World Neurosurg"}],"container-title":["Journal of Plastic, Reconstructive &amp; Aesthetic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S174868152100646X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S174868152100646X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T20:46:24Z","timestamp":1761684384000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S174868152100646X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5]]},"references-count":28,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022,5]]}},"alternative-id":["S174868152100646X"],"URL":"https:\/\/doi.org\/10.1016\/j.bjps.2021.11.101","relation":{},"ISSN":["1748-6815"],"issn-type":[{"value":"1748-6815","type":"print"}],"subject":[],"published":{"date-parts":[[2022,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Accurate reconstruction of bone defects in orbital\u2013maxillary\u2013zygomatic (OMZ) complex with polyetheretherketone (PEEK)","name":"articletitle","label":"Article Title"},{"value":"Journal of Plastic, Reconstructive & Aesthetic Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.bjps.2021.11.101","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 Published by Elsevier Ltd on behalf of British Association of Plastic, Reconstructive and Aesthetic Surgeons.","name":"copyright","label":"Copyright"}]}}