{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T22:06:10Z","timestamp":1740175570691,"version":"3.37.3"},"reference-count":16,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2017,1,1]],"date-time":"2017-01-01T00:00:00Z","timestamp":1483228800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,1,6]],"date-time":"2017-01-06T00:00:00Z","timestamp":1483660800000},"content-version":"vor","delay-in-days":5,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["elsevier.es","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Bolet\u00edn M\u00e9dico del Hospital Infantil de M\u00e9xico"],"published-print":{"date-parts":[[2017,1]]},"DOI":"10.1016\/j.bmhimx.2016.10.009","type":"journal-article","created":{"date-parts":[[2017,1,25]],"date-time":"2017-01-25T23:30:33Z","timestamp":1485387033000},"page":"65-69","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Par\u00e1metros de programaci\u00f3n del implante coclear"],"prefix":"10.1016","volume":"74","author":[{"given":"Rosa Isela","family":"Banda Gonz\u00e1lez","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Salvador","family":"Castillo Castillo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Graciela","family":"Roque Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"year":"2009","series-title":"Implante coclear en el paciente pedi\u00e1trico","author":"De la Torre","key":"10.1016\/j.bmhimx.2016.10.009_bib0085"},{"year":"2002","series-title":"Implantes Cocleares","author":"Manrique-Rodr\u00edguez","key":"10.1016\/j.bmhimx.2016.10.009_bib0090"},{"key":"10.1016\/j.bmhimx.2016.10.009_bib0095","unstructured":"World Health Organization [Internet]. WHO: Deafness and hearing loss. Citado 05 de junio 2014. Disponible en: http:\/\/www.who.int\/mediacentre\/factsheets\/fs300\/en\/"},{"key":"10.1016\/j.bmhimx.2016.10.009_bib0100","unstructured":"Estrada MD, Benitez D, Claros P, Claver\u00eda MA, Oros C, Pujol MC. Evaluaci\u00f3n de los implantes cocleares bilaterales en ni\u00f1os. Criterios de indicaci\u00f3n de los implantes cocleares en ni\u00f1os y adultos. Ministerio de Ciencia e Innovaci\u00f3n: Informes de Evaluaci\u00f3n de Tecnolog\u00edas Sanitarias: AIAQS; 2010. Fecha de acceso: 05 de junio 2014. Disponible en: http:\/\/aquas.gencat.cat\/web\/.content\/minisite\/aquas\/publicacions\/2011\/pdf\/implantes_cocleares_pcsns_aiaqs2011.pdf"},{"key":"10.1016\/j.bmhimx.2016.10.009_bib0105","unstructured":"Pedraza-G\u00f3mez MJ, Llorente-Parrado C, Callejo-Velasco D. Implante coclear bilateral en ni\u00f1os: efectividad, seguridad y costes. Situaci\u00f3n en las comunidades aut\u00f3nomas. Madrid: Unidad de Evaluaci\u00f3n de Tecnolog\u00edas Sanitarias (UETS), Agencia La\u00edn Entralgo; 2007. No. reporte: 978-84-451-3073-8."},{"key":"10.1016\/j.bmhimx.2016.10.009_bib0110","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/S0001-6519(08)73254-0","article-title":"Revisi\u00f3n de los criterios audiom\u00e9tricos en el tratamiento de la hipoacusia neurosensorial mediante aud\u00edfonos y pr\u00f3tesis auditivas implantables","volume":"59","author":"Manrique","year":"2008","journal-title":"Acta Otorrinolaringol Esp."},{"key":"10.1016\/j.bmhimx.2016.10.009_bib0115","unstructured":"Cochlear clinical guidance document. Australia: Cochlear Ltd.; 2010. Disponible en: http:\/\/cochlear-cee-training.org\/word-press\/wp-content\/uploads\/2011\/12\/231495_ISS3_EN_CSS_Clinical_Guidance_Document.pdf"},{"key":"10.1016\/j.bmhimx.2016.10.009_bib0120","unstructured":"Advanced Bionics Corporation. New Methodology for Fitting Cochlear Implants. Valencia; 2003."},{"key":"10.1016\/j.bmhimx.2016.10.009_bib0125","unstructured":"Advanced Bionics. Soundwave versi\u00f3n 2.0 Professional Suite [software] 2010. Citado 05 de Junio de 2014. Disponible en: advancedbionics.com\/com\/en\/professionals\/fiting-software.html."},{"key":"10.1016\/j.bmhimx.2016.10.009_bib0130","doi-asserted-by":"crossref","first-page":"302","DOI":"10.3766\/jaaa.23.5.2","article-title":"Optimization of programming parameters in children with the advanced bionics cochlear implant","volume":"23","author":"Baudhuin","year":"2012","journal-title":"J Am Acad Audiol."},{"year":"2010","series-title":"Programing Cochlear Implants","author":"Wolfe","key":"10.1016\/j.bmhimx.2016.10.009_bib0135"},{"key":"10.1016\/j.bmhimx.2016.10.009_bib0140","doi-asserted-by":"crossref","first-page":"2236","DOI":"10.1121\/1.2537501","article-title":"Effects of carrier pulse rate and stimulation site on modulation detection by subjects with cochlear implants","volume":"121","author":"Pfingst","year":"2007","journal-title":"J Acoust Soc Am."},{"key":"10.1016\/j.bmhimx.2016.10.009_bib0145","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.heares.2008.06.010","article-title":"Effects of stimulus manipulation on electrophysiological responses of pediatric cochlear implant users. Part II: rate effects","volume":"244","author":"Davids","year":"2008","journal-title":"Hear Res."},{"key":"10.1016\/j.bmhimx.2016.10.009_bib0150","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/0378-5955(85)90005-X","article-title":"Threshold and loudness functions for pulsatile stimulation of cochlear Implants","volume":"18","author":"Shannon","year":"1985","journal-title":"Hear Res."},{"key":"10.1016\/j.bmhimx.2016.10.009_bib0155","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.heares.2008.06.011","article-title":"Effects of stimulus manipulation on electrophysiological responses in pediatric cochlear implant users. Part I: duration effects","volume":"244","author":"Davids","year":"2008","journal-title":"Hear Res."},{"key":"10.1016\/j.bmhimx.2016.10.009_bib0160","first-page":"213","article-title":"Complicaciones y causas de fallo en cirug\u00eda de implante coclear en pacientes del servicio de otorrinolaringolog\u00eda del Hospital Universitario Cl\u00ednica San Rafael","volume":"39","author":"Jim\u00e9nez","year":"2011","journal-title":"Acta Otorrinolaringol CCC."}],"container-title":["Bolet\u00edn M\u00e9dico del Hospital Infantil de M\u00e9xico"],"original-title":[],"language":"es","link":[{"URL":"http:\/\/api.elsevier.com\/content\/article\/PII:S1665114617300059?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/api.elsevier.com\/content\/article\/PII:S1665114617300059?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,10,18]],"date-time":"2018-10-18T15:46:31Z","timestamp":1539877591000},"score":1,"resource":{"primary":{"URL":"http:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1665114617300059"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1]]},"references-count":16,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017,1]]}},"alternative-id":["S1665114617300059"],"URL":"https:\/\/doi.org\/10.1016\/j.bmhimx.2016.10.009","relation":{},"ISSN":["1665-1146"],"issn-type":[{"type":"print","value":"1665-1146"}],"subject":[],"published":{"date-parts":[[2017,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Par\u00e1metros de programaci\u00f3n del implante coclear","name":"articletitle","label":"Article Title"},{"value":"Bolet\u00edn M\u00e9dico del Hospital Infantil de M\u00e9xico","name":"journaltitle","label":"Journal Title"},{"value":"http:\/\/dx.doi.org\/10.1016\/j.bmhimx.2016.10.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Hospital Infantil de M\u00e9xico Federico G\u00f3mez. Published by Masson Doyma M\u00e9xico S.A.","name":"copyright","label":"Copyright"}]}}