{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T19:27:07Z","timestamp":1792783627941,"version":"4.5.0"},"reference-count":32,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2013,9,1]],"date-time":"2013-09-01T00:00:00Z","timestamp":1377993600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"name":"McCabe Pilot Award"},{"name":"Penn Center for Musculoskeletal Disorders","award":["NIH\/NIAMS P30AR050950"],"award-info":[{"award-number":["NIH\/NIAMS P30AR050950"]}]}],"content-domain":{"domain":["thebonejournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Bone"],"published-print":{"date-parts":[[2013,9]]},"DOI":"10.1016\/j.bone.2013.05.014","type":"journal-article","created":{"date-parts":[[2013,5,28]],"date-time":"2013-05-28T02:46:25Z","timestamp":1369709185000},"page":"83-90","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":43,"title":["3D image registration is critical to ensure accurate detection of longitudinal changes in trabecular bone density, microstructure, and stiffness measurements in rat tibiae by in vivo microcomputed tomography (\u03bcCT)"],"prefix":"10.1016","volume":"56","author":[{"given":"Shenghui","family":"Lan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shiming","family":"Luo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Beom Kang","family":"Huh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abhishek","family":"Chandra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Allison R.","family":"Altman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ling","family":"Qin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"X. Sherry","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.bone.2013.05.014_bb0005","doi-asserted-by":"crossref","first-page":"1468","DOI":"10.1002\/jbmr.141","article-title":"Guidelines for assessment of bone microstructure in rodents using micro-computed tomography","volume":"25","author":"Bouxsein","year":"2010","journal-title":"J Bone Miner Res"},{"key":"10.1016\/j.bone.2013.05.014_bb0010","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/j.bone.2003.08.012","article-title":"Detecting and tracking local changes in the tibiae of individual rats: a novel method to analyse longitudinal in vivo micro-CT data","volume":"34","author":"Waarsing","year":"2004","journal-title":"Bone"},{"key":"10.1016\/j.bone.2013.05.014_bb0015","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1007\/s00223-007-9084-3","article-title":"Bone degeneration and recovery after early and late bisphosphonate treatment of ovariectomized Wistar rats assessed by in vivo micro-computed tomography","volume":"82","author":"Brouwers","year":"2008","journal-title":"Calcif Tissue Int"},{"key":"10.1016\/j.bone.2013.05.014_bb0020","doi-asserted-by":"crossref","first-page":"1521","DOI":"10.1002\/jor.20913","article-title":"Comparison of bone loss induced by ovariectomy and neurectomy in rats analyzed by in vivo micro-CT","volume":"27","author":"Brouwers","year":"2009","journal-title":"J Orthop Res"},{"key":"10.1016\/j.bone.2013.05.014_bb0025","doi-asserted-by":"crossref","first-page":"1325","DOI":"10.1002\/jor.20439","article-title":"No effects of in vivo micro-CT radiation on structural parameters and bone marrow cells in proximal tibia of Wistar rats detected after eight weekly scans","volume":"25","author":"Brouwers","year":"2007","journal-title":"J Orthop Res"},{"key":"10.1016\/j.bone.2013.05.014_bb0030","doi-asserted-by":"crossref","first-page":"854","DOI":"10.1016\/j.bone.2006.04.017","article-title":"Monitoring individual morphological changes over time in ovariectomized rats by in vivo micro-computed tomography","volume":"39","author":"Boyd","year":"2006","journal-title":"Bone"},{"key":"10.1016\/j.bone.2013.05.014_bb0035","series-title":"Signs of irreversible architectural changes occur early in the development of experimental osteoporosis as assessed by in vivo micro-CT","author":"Campbell","year":"2008"},{"key":"10.1016\/j.bone.2013.05.014_bb0040","doi-asserted-by":"crossref","first-page":"2048","DOI":"10.1359\/jbmr.080808","article-title":"Postpubertal architectural developmental patterns differ between the L3 vertebra and proximal tibia in three inbred strains of mice","volume":"23","author":"Buie","year":"2008","journal-title":"J Bone Miner Res"},{"key":"10.1016\/j.bone.2013.05.014_bb0045","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1002\/jor.20063","article-title":"Bone loss dynamics result in trabecular alignment in aging and ovariectomized rats","volume":"24","author":"Waarsing","year":"2006","journal-title":"J Orthop Res"},{"key":"10.1016\/j.bone.2013.05.014_bb0050","doi-asserted-by":"crossref","first-page":"1340","DOI":"10.1016\/j.bone.2011.08.035","article-title":"Mouse tail vertebrae adapt to cyclic mechanical loading by increasing bone formation rate and decreasing bone resorption rate as shown by time-lapsed in vivo imaging of dynamic bone morphometry","volume":"49","author":"Lambers","year":"2011","journal-title":"Bone"},{"key":"10.1016\/j.bone.2013.05.014_bb0055","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1016\/j.bone.2010.10.007","article-title":"In vivo micro-computed tomography allows direct three-dimensional quantification of both bone formation and bone resorption parameters using time-lapsed imaging","volume":"48","author":"Schulte","year":"2011","journal-title":"Bone"},{"key":"10.1016\/j.bone.2013.05.014_bb0060","doi-asserted-by":"crossref","first-page":"413","DOI":"10.3233\/THC-1998-65-613","article-title":"Assessment of cancellous bone mechanical properties from micro-FE models based on micro-CT, pQCT and MR images","volume":"6","author":"van Rietbergen","year":"1998","journal-title":"Technol Health Care"},{"key":"10.1016\/j.bone.2013.05.014_bb0065","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1146\/annurev.bioeng.3.1.307","article-title":"Biomechanics of trabecular bone","volume":"3","author":"Keaveny","year":"2001","journal-title":"Annu Rev Biomed Eng"},{"key":"10.1016\/j.bone.2013.05.014_bb0070","doi-asserted-by":"crossref","first-page":"1587","DOI":"10.1007\/s10439-006-9168-7","article-title":"Evaluation of three-dimensional image registration methodologies for in vivo micro-computed tomography","volume":"34","author":"Boyd","year":"2006","journal-title":"Ann Biomed Eng"},{"key":"10.1016\/j.bone.2013.05.014_bb0075","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.bone.2009.09.023","article-title":"Reproducibility of bone micro-architecture measurements in rodents by in vivo micro-computed tomography is maximized with three-dimensional image registration","volume":"46","author":"Nishiyama","year":"2010","journal-title":"Bone"},{"key":"10.1016\/j.bone.2013.05.014_bb0080","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1016\/j.bone.2011.05.013","article-title":"MicroCT morphometry analysis of mouse cancellous bone: intra- and inter-system reproducibility","volume":"49","author":"Verdelis","year":"2011","journal-title":"Bone"},{"key":"10.1016\/j.bone.2013.05.014_bb0085","doi-asserted-by":"crossref","first-page":"1286","DOI":"10.1118\/1.3096605","article-title":"Assessment of trabecular bone microarchitecture by two different x-ray microcomputed tomographs: a comparative study of the rat distal tibia using Skyscan and Scanco devices","volume":"36","author":"Bonnet","year":"2009","journal-title":"Med Phys"},{"key":"10.1016\/j.bone.2013.05.014_bb0090","doi-asserted-by":"crossref","first-page":"1375","DOI":"10.1016\/j.bone.2004.09.007","article-title":"The effect of microcomputed tomography scanning and reconstruction voxel size on the accuracy of stereological measurements in human cancellous bone","volume":"35","author":"Kim","year":"2004","journal-title":"Bone"},{"key":"10.1016\/j.bone.2013.05.014_bb0095","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1023\/A:1007958904918","article-title":"Alignment by maximization of mutual information","volume":"24","author":"Viola","year":"1997","journal-title":"Int J Comput Vis"},{"key":"10.1016\/j.bone.2013.05.014_bb0100","series-title":"Information processing in medical imaging","first-page":"263","article-title":"Automated multi-modality image registration based on information theory","author":"Collignon","year":"1995"},{"key":"10.1016\/j.bone.2013.05.014_bb0105","series-title":"Consortium tIS. The ITK software guide","author":"lbanez","year":"2005"},{"key":"10.1016\/j.bone.2013.05.014_bb0110","doi-asserted-by":"crossref","first-page":"746","DOI":"10.1002\/jbmr.92","article-title":"High-resolution peripheral quantitative computed tomography can assess microstructural and mechanical properties of human distal tibial bone","volume":"25","author":"Liu","year":"2010","journal-title":"J Bone Miner Res"},{"key":"10.1016\/j.bone.2013.05.014_bb0115","first-page":"185","article-title":"Is trabecular bone tissue different from cortical bone tissue?","volume":"12","author":"Guo","year":"1997","journal-title":"Forma"},{"key":"10.1016\/j.bone.2013.05.014_bb0120","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1016\/0021-9290(94)90019-1","article-title":"A homogenization sampling procedure for calculating trabecular bone effective stiffness and tissue level stress","volume":"27","author":"Hollister","year":"1994","journal-title":"J Biomech"},{"key":"10.1016\/j.bone.2013.05.014_bb0125","doi-asserted-by":"crossref","first-page":"1203","DOI":"10.1016\/j.bone.2008.01.017","article-title":"Bone strength at the distal radius can be estimated from high-resolution peripheral quantitative computed tomography and the finite element method","volume":"42","author":"Macneil","year":"2008","journal-title":"Bone"},{"key":"10.1016\/j.bone.2013.05.014_bb0130","doi-asserted-by":"crossref","first-page":"2296","DOI":"10.1002\/jbmr.152","article-title":"Abnormal microarchitecture and reduced stiffness at the radius and tibia in postmenopausal women with fractures","volume":"25","author":"Stein","year":"2010","journal-title":"J Bone Miner Res"},{"key":"10.1016\/j.bone.2013.05.014_bb0135","doi-asserted-by":"crossref","first-page":"1161","DOI":"10.1007\/s00198-009-1047-2","article-title":"Assessing forearm fracture risk in postmenopausal women","volume":"21","author":"Melton","year":"2010","journal-title":"Osteoporos Int"},{"key":"10.1016\/j.bone.2013.05.014_bb0140","doi-asserted-by":"crossref","first-page":"1030","DOI":"10.1016\/j.bone.2009.12.015","article-title":"Finite element analysis performed on radius and tibia HR-pQCT images and fragility fractures at all sites in postmenopausal women","volume":"46","author":"Vilayphiou","year":"2010","journal-title":"Bone"},{"key":"10.1016\/j.bone.2013.05.014_bb0145","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1097\/00004728-199707000-00007","article-title":"Comparison and evaluation of retrospective intermodality brain image registration techniques","volume":"21","author":"West","year":"1997","journal-title":"J Comput Assist Tomogr"},{"key":"10.1016\/j.bone.2013.05.014_bb0150","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1016\/j.imavis.2006.08.002","article-title":"Monomodal image registration using mutual information based methods","volume":"26","author":"Gao","year":"2008","journal-title":"Image Vis Comput"},{"key":"10.1016\/j.bone.2013.05.014_bb0155","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1109\/42.774168","article-title":"Registration of stereo and temporal images of the retina","volume":"18","author":"Ritter","year":"1999","journal-title":"IEEE Trans Med Imaging"},{"key":"10.1016\/j.bone.2013.05.014_bb0160","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1109\/42.845176","article-title":"Semiautomatic 3-D image registration as applied to interventional MRI liver cancer treatment","volume":"19","author":"Carrillo","year":"2000","journal-title":"IEEE Trans Med Imaging"}],"container-title":["Bone"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S8756328213001968?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S8756328213001968?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2020,7,27]],"date-time":"2020-07-27T01:45:05Z","timestamp":1595814305000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S8756328213001968"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,9]]},"references-count":32,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2013,9]]}},"alternative-id":["S8756328213001968"],"URL":"https:\/\/doi.org\/10.1016\/j.bone.2013.05.014","relation":{},"ISSN":["8756-3282"],"issn-type":[{"value":"8756-3282","type":"print"}],"subject":[],"published":{"date-parts":[[2013,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"3D image registration is critical to ensure accurate detection of longitudinal changes in trabecular bone density, microstructure, and stiffness measurements in rat tibiae by in vivo microcomputed tomography (\u03bcCT)","name":"articletitle","label":"Article Title"},{"value":"Bone","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.bone.2013.05.014","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2013 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}