{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T23:54:28Z","timestamp":1782431668782,"version":"3.54.5"},"reference-count":40,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2013,11,1]],"date-time":"2013-11-01T00:00:00Z","timestamp":1383264000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2013,11,1]],"date-time":"2013-11-01T00:00:00Z","timestamp":1383264000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["brachyjournal.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Brachytherapy"],"published-print":{"date-parts":[[2013,11]]},"DOI":"10.1016\/j.brachy.2013.04.009","type":"journal-article","created":{"date-parts":[[2013,7,11]],"date-time":"2013-07-11T10:00:58Z","timestamp":1373536858000},"page":"637-644","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":7,"title":["Dosimetric comparison of optimization methods for multichannel intracavitary brachytherapy for superficial vaginal tumors"],"prefix":"10.1016","volume":"12","author":[{"given":"Carminia","family":"Lapuz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claire","family":"Dempsey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anne","family":"Capp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter C.","family":"O\u2019Brien","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.brachy.2013.04.009_bib1","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1002\/1097-0142(19870801)60:3<419::AID-CNCR2820600323>3.0.CO;2-A","article-title":"Isolated vaginal recurrences of endometrial adenocarcinoma and their management","volume":"60","author":"Greven","year":"1987","journal-title":"Cancer"},{"key":"10.1016\/j.brachy.2013.04.009_bib2","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1016\/0360-3016(88)90111-3","article-title":"The salvage of recurrent endometrial carcinoma in the vagina and pelvis","volume":"15","author":"Poulsen","year":"1988","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2013.04.009_bib3","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1006\/gyno.1997.4752","article-title":"Isolated vaginal recurrences in endometrial carcinoma: Treatment results using high-dose-rate intracavitary brachytherapy and external beam radiotherapy","volume":"66","author":"Pai","year":"1997","journal-title":"Gynecol Oncol"},{"key":"10.1016\/j.brachy.2013.04.009_bib4","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1006\/gyno.1997.4722","article-title":"Perineal template interstitial brachytherapy salvage for recurrent endometrial adenocarcinoma metastatic to the vagina","volume":"66","author":"Nag","year":"1997","journal-title":"Gynecol Oncol"},{"key":"10.1016\/j.brachy.2013.04.009_bib5","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1016\/S0360-3016(97)00576-2","article-title":"Outcome of treatment of upper third vaginal recurrences of cervical and endometrial carcinomas with interstitial brachytherapy","volume":"40","author":"Charra","year":"1998","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2013.04.009_bib6","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1006\/gyno.1999.5487","article-title":"Interstitial brachytherapy for vaginal recurrences of endometrial carcinoma","volume":"74","author":"Tewari","year":"1999","journal-title":"Gynecol Oncol"},{"key":"10.1016\/j.brachy.2013.04.009_bib7","doi-asserted-by":"crossref","first-page":"1153","DOI":"10.1016\/S0360-3016(02)03019-5","article-title":"Interstitial brachytherapy for salvage treatment of vaginal recurrences in previously unirradiated endometrial cancer patients","volume":"54","author":"Nag","year":"2002","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2013.04.009_bib8","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/S0167-8140(02)00212-8","article-title":"Outcome after salvage radiotherapy (brachytherapy\u00a0+\/- external) in patients with a vaginal recurrence from endometrial carcinomas","volume":"65","author":"Hasbini","year":"2002","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2013.04.009_bib9","doi-asserted-by":"crossref","first-page":"1366","DOI":"10.1016\/S0360-3016(03)00414-0","article-title":"Definitive radiotherapy for patients with isolated vaginal recurrence of endometrial carcinoma after hysterectomy","volume":"56","author":"Jhingran","year":"2003","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2013.04.009_bib10","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/j.ygyno.2005.11.004","article-title":"Salvage treatment with high-dose-rate brachytherapy for isolated vaginal endometrial cancer recurrence","volume":"101","author":"Petignat","year":"2006","journal-title":"Gynecol Oncol"},{"key":"10.1016\/j.brachy.2013.04.009_bib11","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1186\/1748-717X-3-7","article-title":"High-dose rate brachytherapy (HDRB) for primary or recurrent cancer in the vagina","volume":"3","author":"Beriwal","year":"2008","journal-title":"Radiat Oncol"},{"key":"10.1016\/j.brachy.2013.04.009_bib12","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/j.brachy.2011.05.005","article-title":"Three-dimensional image-based high-dose-rate interstitial brachytherapy for vaginal cancer","volume":"11","author":"Beriwal","year":"2012","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2013.04.009_bib13","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1016\/S0360-3016(00)00689-1","article-title":"The American Brachytherapy Society recommendations for high-dose-rate brachytherapy for carcinoma of the endometrium","volume":"48","author":"Nag","year":"2000","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2013.04.009_bib14","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.brachy.2011.06.008","article-title":"American Brachytherapy Society consensus guidelines for interstitial brachytherapy for vaginal cancer","volume":"11","author":"Beriwal","year":"2012","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2013.04.009_bib15","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/S0360-3016(98)00453-2","article-title":"The use and advantages of a multichannel vaginal cylinder in high-dose-rate brachytherapy","volume":"44","author":"Demanes","year":"1999","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2013.04.009_bib16","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/j.radonc.2003.11.006","article-title":"Multi-channel intracavitary vaginal brachytherapy using three-dimensional optimization of source geometry","volume":"70","author":"Tanderup","year":"2004","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2013.04.009_bib17","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1016\/S0360-3016(96)00572-X","article-title":"A simple, inexpensive applicator for irradiation of localized areas of the vagina with intracavitary brachytherapy","volume":"37","author":"Amdur","year":"1997","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2013.04.009_bib18","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.brachy.2011.08.005","article-title":"American Brachytherapy Society consensus guidelines for adjuvant vaginal cuff brachytherapy after hysterectomy","volume":"11","author":"Small","year":"2012","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2013.04.009_bib19","series-title":"Gynecologic radiation therapy novel approaches to image-guidance and management","first-page":"239","article-title":"Postoperative vaginal cylinder brachytherapy in an era of 3D imaging","author":"Holloway","year":"2011"},{"key":"10.1016\/j.brachy.2013.04.009_bib20","unstructured":"Nucletron Oncentra\u00ae Brachy v4.1, Physics and algorithms manual (192.739ENG06). Veenendaal: Nucletron B.V., an Elekta Company."},{"key":"10.1016\/j.brachy.2013.04.009_bib21","doi-asserted-by":"crossref","first-page":"1243","DOI":"10.1016\/S0360-3016(02)03802-6","article-title":"Inverse planning for interstitial gynecologic template brachytherapy: Truly anatomy-based planning","volume":"54","author":"Lessard","year":"2002","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2013.04.009_bib22","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/j.brachy.2004.05.007","article-title":"Comparison of inverse planning simulated annealing and geometrical optimization for prostate high-dose-rate brachytherapy","volume":"3","author":"Hsu","year":"2004","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2013.04.009_bib23","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.brachy.2007.10.001","article-title":"A comparison of anatomy-based inverse planning with simulated annealing and graphical optimization for high-dose-rate prostate brachytherapy","volume":"7","author":"Morton","year":"2008","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2013.04.009_bib24","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1016\/j.brachy.2010.08.011","article-title":"Comparison of IPSA with dose-point optimization and manual optimization for interstitial template brachytherapy for gynecologic cancers","volume":"10","author":"Jamema","year":"2011","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2013.04.009_bib25","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/j.radonc.2009.10.004","article-title":"New inverse planning technology for image-guided cervical cancer brachytherapy: Description and evaluation within a clinical frame","volume":"93","author":"Trnkova","year":"2009","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2013.04.009_bib26","unstructured":"Miami Vaginal Applicator Set \u00ae User Manual (090.601ENG03). Veenendaal: Nucletron B.V., an Elekta Company."},{"key":"10.1016\/j.brachy.2013.04.009_bib27","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/j.brachy.2011.06.005","article-title":"Inverse-planned gynecologic high-dose-rate interstitial brachytherapy: Clinical outcomes and dose-volume histogram analysis","volume":"11","author":"Thibault","year":"2012","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2013.04.009_bib28","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.radonc.2005.11.014","article-title":"Recommendations from gynaecological (GYN) GEC ESTRO working group (II): Concepts and terms in 3D image-based treatment planning in cervix cancer brachytherapy-3D dose volume parameters and aspects of 3D image-based anatomy, radiation physics, radiobiology","volume":"78","author":"Potter","year":"2006","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2013.04.009_bib29","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1118\/1.596152","article-title":"A dose homogeneity index for evaluating 192Ir interstitial breast implants","volume":"15","author":"Wu","year":"1988","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2013.04.009_bib30","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1016\/S0360-3016(96)00601-3","article-title":"A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: Application to the prostate","volume":"37","author":"van't Riet","year":"1997","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2013.04.009_bib31","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/S0360-3016(97)00732-3","article-title":"A conformal index (COIN) to evaluate implant quality and dose specification in brachytherapy","volume":"40","author":"Baltas","year":"1998","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2013.04.009_bib32","doi-asserted-by":"crossref","first-page":"2263","DOI":"10.1088\/0031-9155\/47\/13\/306","article-title":"Multiobjective anatomy-based dose optimization for HDR-brachytherapy with constraint free deterministic algorithms","volume":"47","author":"Milickovic","year":"2002","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.brachy.2013.04.009_bib33","doi-asserted-by":"crossref","first-page":"163","DOI":"10.5114\/jcb.2010.19497","article-title":"A detailed dosimetric comparison between manual and inverse plans in HDR intracavitary\/interstitial cervical cancer brachytherapy","volume":"2","author":"Trnkova","year":"2010","journal-title":"J Contemp Brachytherapy"},{"key":"10.1016\/j.brachy.2013.04.009_bib34","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.1016\/j.ijrobp.2006.11.021","article-title":"Uncertainties in assessment of the vaginal dose for intracavitary brachytherapy of cervical cancer using a tandem-ring applicator","volume":"67","author":"Berger","year":"2007","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2013.04.009_bib35","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/S0167-8140(02)00384-5","article-title":"The irradiation tolerance dose of the proximal vagina","volume":"67","author":"Au","year":"2003","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2013.04.009_bib36","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1016\/j.radonc.2010.05.005","article-title":"Dose volume parameter D2cc does not correlate with vaginal side effects in individual patients with cervical cancer treated within a defined treatment protocol with very high brachytherapy doses","volume":"97","author":"Fidarova","year":"2010","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2013.04.009_bib37","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1016\/S0360-3016(99)00330-2","article-title":"A simple method of obtaining equivalent doses for use in HDR brachytherapy","volume":"46","author":"Nag","year":"2000","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2013.04.009_bib38","doi-asserted-by":"crossref","first-page":"S259","DOI":"10.1016\/S0167-8140(11)70759-9","article-title":"Dosimetry of single, multi-channel intracavitary and interstitial HDR brachytherapy using 3D inverse planning","volume":"99","author":"Dempsey","year":"2011","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2013.04.009_bib39","doi-asserted-by":"crossref","first-page":"1880","DOI":"10.1016\/j.ijrobp.2011.03.049","article-title":"Treatment of locally advanced vaginal cancer with radiochemotherapy and magnetic resonance image-guided adaptive brachytherapy: Dose-volume parameters and first clinical results","volume":"82","author":"Dimopoulos","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2013.04.009_bib40","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/j.ijrobp.2006.04.037","article-title":"Magnetic resonance-guided interstitial therapy for vaginal recurrence of endometrial cancer","volume":"66","author":"Viswanathan","year":"2006","journal-title":"Int J Radiat Oncol Biol Phys"}],"container-title":["Brachytherapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1538472113002766?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1538472113002766?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T02:07:08Z","timestamp":1761530828000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1538472113002766"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,11]]},"references-count":40,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2013,11]]}},"alternative-id":["S1538472113002766"],"URL":"https:\/\/doi.org\/10.1016\/j.brachy.2013.04.009","relation":{},"ISSN":["1538-4721"],"issn-type":[{"value":"1538-4721","type":"print"}],"subject":[],"published":{"date-parts":[[2013,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Dosimetric comparison of optimization methods for multichannel intracavitary brachytherapy for superficial vaginal tumors","name":"articletitle","label":"Article Title"},{"value":"Brachytherapy","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.brachy.2013.04.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2013 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}