{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,17]],"date-time":"2026-05-17T08:32:07Z","timestamp":1779006727873,"version":"3.51.4"},"reference-count":29,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2015,11,1]],"date-time":"2015-11-01T00:00:00Z","timestamp":1446336000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2015,11,1]],"date-time":"2015-11-01T00:00:00Z","timestamp":1446336000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["brachyjournal.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Brachytherapy"],"published-print":{"date-parts":[[2015,11]]},"DOI":"10.1016\/j.brachy.2015.04.011","type":"journal-article","created":{"date-parts":[[2015,6,6]],"date-time":"2015-06-06T19:31:16Z","timestamp":1433619076000},"page":"889-897","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":21,"title":["Assessing changes to the brachytherapy target for cervical cancer using a single MRI and serial ultrasound"],"prefix":"10.1016","volume":"14","author":[{"given":"Sylvia","family":"van Dyk","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Srinivas","family":"Kondalsamy-Chennakesavan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michal","family":"Schneider","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Bernshaw","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kailash","family":"Narayan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.brachy.2015.04.011_bib1","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/0167-8140(96)01746-X","article-title":"Changes in applicator position with fractionated high dose rate gynaecological brachytherapy","volume":"40","author":"Hoskin","year":"1996","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2015.04.011_bib2","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1016\/j.brachy.2004.07.001","article-title":"Is simulation necessary for each high-dose-rate tandem and ovoid insertion in carcinoma of the cervix?","volume":"3","author":"Jones","year":"2004","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2015.04.011_bib3","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1016\/j.ijrobp.2014.06.005","article-title":"Comparison and consensus guidelines for delineation of clinical target volume for CT- and MR-based brachytherapy in locally advanced cervical cancer","volume":"90","author":"Viswanathan","year":"2014","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2015.04.011_bib4","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.radonc.2004.12.015","article-title":"Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group (I): Concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV","volume":"74","author":"Haie-Meder","year":"2005","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2015.04.011_bib5","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.radonc.2005.11.014","article-title":"Recommendations from gynaecological (GYN) GEC ESTRO working group (II): Concepts and terms in 3D image-based treatment planning in cervix cancer brachytherapy\u20143D dose volume parameters and aspects of 3D image-based anatomy, radiation physics, radiobiology","volume":"78","author":"Potter","year":"2006","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2015.04.011_bib6","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/j.clon.2008.12.001","article-title":"Clinical impact of computed tomography-based image-guided brachytherapy for cervix cancer using the tandem-ring applicator\u2014The Addenbrooke's experience","volume":"21","author":"Tan","year":"2009","journal-title":"Clin Oncol"},{"key":"10.1016\/j.brachy.2015.04.011_bib7","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.radonc.2011.07.012","article-title":"Clinical outcome of protocol based image (MRI) guided adaptive brachytherapy combined with 3D conformal radiotherapy with or without chemotherapy in patients with locally advanced cervical cancer","volume":"100","author":"P\u00f6tter","year":"2011","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2015.04.011_bib8","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1016\/j.radonc.2012.04.007","article-title":"Impact of 3D image-based PDR brachytherapy on outcome of patients treated for cervix carcinoma in France: Results of the French STIC prospective study","volume":"103","author":"Charra-Brunaud","year":"2012","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2015.04.011_bib9","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.radonc.2006.10.016","article-title":"Uncertainties when using only one MRI-based treatment plan for subsequent high-dose-rate tandem and ring applications in brachytherapy of cervix cancer","volume":"81","author":"Kirisits","year":"2006","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2015.04.011_bib10","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/j.ijrobp.2006.12.021","article-title":"Computed tomography versus magnetic resonance imaging-based contouring in cervical cancer brachytherapy: Results of a prospective trial and preliminary guidelines for standardized contours","volume":"68","author":"Viswanathan","year":"2007","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2015.04.011_bib11","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1016\/j.clon.2009.03.007","article-title":"Single magnetic resonance imaging vs magnetic resonance imaging\/computed tomography planning in cervical cancer brachytherapy","volume":"21","author":"Beriwal","year":"2009","journal-title":"Clin Oncol"},{"key":"10.1016\/j.brachy.2015.04.011_bib12","doi-asserted-by":"crossref","first-page":"860","DOI":"10.1016\/j.ijrobp.2013.12.004","article-title":"Comparison of measurements of the uterus and cervix obtained by magnetic resonance and transabdominal ultrasound imaging to identify the brachytherapy target in patients with cervix cancer","volume":"88","author":"van Dyk","year":"2014","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2015.04.011_bib13","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1016\/j.ijrobp.2008.10.057","article-title":"Conformal brachytherapy planning for cervical cancer using transabdominal ultrasound","volume":"75","author":"van Dyk","year":"2009","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2015.04.011_bib14","doi-asserted-by":"crossref","first-page":"307","DOI":"10.2307\/2987937","article-title":"Measurement in medicine: The analysis of method comparison studies","volume":"32","author":"Altman","year":"1983","journal-title":"Statistician"},{"key":"10.1016\/j.brachy.2015.04.011_bib15","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1002\/uog.122","article-title":"Applying the right statistics: Analyses of measurement studies","volume":"22","author":"Bland","year":"2003","journal-title":"Ultrasound Obstet Gynecol"},{"key":"10.1016\/j.brachy.2015.04.011_bib16","unstructured":"Motulsky H. Graphpad statistics guide. Available at: http:\/\/graphpad.com\/guides\/prism\/6\/statistics\/index.htm?bland-altman_results.htm. Accessed January 2015."},{"key":"10.1016\/j.brachy.2015.04.011_bib17","doi-asserted-by":"crossref","first-page":"1005","DOI":"10.2307\/2532694","article-title":"Adjusted P-values for simultaneous inference","volume":"48","author":"Wright","year":"1992","journal-title":"Biometrics"},{"key":"10.1016\/j.brachy.2015.04.011_bib18","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.radonc.2013.01.006","article-title":"Critical structure movement in cervix brachytherapy","volume":"107","author":"Anderson","year":"2013","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2015.04.011_bib19","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.radonc.2013.01.011","article-title":"Inter-application variation of dose and spatial location of volumes of OARs during MR image based cervix brachytherapy","volume":"107","author":"Jamema","year":"2013","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2015.04.011_bib20","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.radonc.2012.11.006","article-title":"Feasibility of applying a single treatment plan for both fractions in PDR image guided brachytherapy in cervix cancer","volume":"107","author":"Mohamed","year":"2013","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2015.04.011_bib21","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1016\/j.radonc.2014.08.010","article-title":"Intra-fraction uncertainties of MRI guided brachytherapy in patients with cervical cancer","volume":"112","author":"Nomden","year":"2014","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2015.04.011_bib22","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1016\/j.brachy.2014.05.016","article-title":"Evaluation of intrafraction motion of the organs at risk in image-based brachytherapy of cervical cancer","volume":"13","author":"Simha","year":"2014","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2015.04.011_bib23","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.brachy.2007.12.003","article-title":"Image-guided cervix high-dose-rate brachytherapy treatment planning: Does custom computed tomography planning for each insertion provide better conformal avoidance of organs at risk?","volume":"7","author":"Davidson","year":"2008","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2015.04.011_bib24","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1007\/s00066-009-1918-7","article-title":"MRI assessment of cervical cancer for adaptive radiotherapy","volume":"185","author":"Dimopoulos","year":"2009","journal-title":"Strahlenther Onkol"},{"key":"10.1016\/j.brachy.2015.04.011_bib25","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.radonc.2008.06.010","article-title":"Consequences of random and systematic reconstruction uncertainties in 3D image based brachytherapy in cervical cancer","volume":"89","author":"Tanderup","year":"2008","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2015.04.011_bib26","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.radonc.2013.02.015","article-title":"Uncertainty analysis for 3D image-based cervix cancer brachytherapy by repetitive MR imaging: Assessment of DVH-variations between two HDR fractions within one applicator insertion and their clinical relevance","volume":"107","author":"Lang","year":"2013","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2015.04.011_bib27","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/S0167-8140(01)00352-8","article-title":"Variations of intracavitary applicator geometry during multiple HDR brachytherapy insertions in carcinoma cervix and its influence on reporting as per ICRU report 38","volume":"60","author":"Datta","year":"2001","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2015.04.011_bib28","doi-asserted-by":"crossref","first-page":"113","DOI":"10.3349\/ymj.2004.45.1.113","article-title":"Use of the rectal retractor to reduce the rectal dose in high dose rate intracavitary brachytherapy for a carcinoma of the uterine cervix","volume":"45","author":"Lee","year":"2004","journal-title":"Yonsei Med J"},{"key":"10.1016\/j.brachy.2015.04.011_bib29","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1016\/j.ijrobp.2007.06.048","article-title":"Effect of bladder distension on dose distribution of intracavitary brachytherapy for cervical cancer: Three-dimensional computed tomography plan evaluation","volume":"70","author":"Cengiz","year":"2008","journal-title":"Int J Radiat Oncol Biol Phys"}],"container-title":["Brachytherapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1538472115004742?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1538472115004742?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T02:08:40Z","timestamp":1761530920000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1538472115004742"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,11]]},"references-count":29,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2015,11]]}},"alternative-id":["S1538472115004742"],"URL":"https:\/\/doi.org\/10.1016\/j.brachy.2015.04.011","relation":{},"ISSN":["1538-4721"],"issn-type":[{"value":"1538-4721","type":"print"}],"subject":[],"published":{"date-parts":[[2015,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Assessing changes to the brachytherapy target for cervical cancer using a single MRI and serial ultrasound","name":"articletitle","label":"Article Title"},{"value":"Brachytherapy","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.brachy.2015.04.011","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Crown copyright \u00a9 2015 Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}