{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T22:17:45Z","timestamp":1792275465005,"version":"4.4.0"},"reference-count":37,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2016,1,1]],"date-time":"2016-01-01T00:00:00Z","timestamp":1451606400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2016,1,1]],"date-time":"2016-01-01T00:00:00Z","timestamp":1451606400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["brachyjournal.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Brachytherapy"],"published-print":{"date-parts":[[2016,1]]},"DOI":"10.1016\/j.brachy.2015.09.010","type":"journal-article","created":{"date-parts":[[2015,11,7]],"date-time":"2015-11-07T00:01:15Z","timestamp":1446854475000},"page":"102-111","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":27,"title":["Comparison of dose and catheter optimization algorithms in prostate high-dose-rate brachytherapy"],"prefix":"10.1016","volume":"15","author":[{"given":"Eric","family":"Poulin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicolas","family":"Varfalvy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sylviane","family":"Aubin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0429-6366","authenticated-orcid":false,"given":"Luc","family":"Beaulieu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.brachy.2015.09.010_bib1","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.radonc.2009.08.033","article-title":"Comparison of three radiotherapy modalities on biochemical control and overall survival for the treatment of prostate cancer: a systematic review","volume":"93","author":"Pieters","year":"2009","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2015.09.010_bib2","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1016\/j.ijrobp.2008.05.003","article-title":"An eight-year experience of HDR brachytherapy boost for localized prostate cancer: biopsy and PSA outcome","volume":"73","author":"Bachand","year":"2009","journal-title":"Int J Radiat Oncol"},{"key":"10.1016\/j.brachy.2015.09.010_bib3","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/j.brachy.2014.03.002","article-title":"High-dose-rate brachytherapy as monotherapy for prostate cancer","volume":"13","author":"Demanes","year":"2014","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2015.09.010_bib4","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1016\/j.radonc.2013.09.025","article-title":"High-dose-rate brachytherapy alone given as two or one fraction to patients for locally advanced prostate cancer: acute toxicity","volume":"110","author":"Hoskin","year":"2014","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2015.09.010_bib5","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.radonc.2013.10.015","article-title":"Monotherapeutic high-dose-rate brachytherapy for prostate cancer: a dose reduction trial","volume":"110","author":"Yoshioka","year":"2014","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2015.09.010_bib6","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1016\/j.ijrobp.2009.08.048","article-title":"Phase II trial of combined high-dose-rate brachytherapy and external beam radiotherapy for adenocarcinoma of the prostate: preliminary results of RTOG 0321","volume":"78","author":"Hsu","year":"2010","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2015.09.010_bib7","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1016\/j.brachy.2012.05.003","article-title":"Clinical outcomes of high-dose-rate brachytherapy and external beam radiotherapy in the management of clinically localized prostate cancer","volume":"12","author":"Kotecha","year":"2013","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2015.09.010_bib8","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.brachy.2012.03.002","article-title":"A phantom study to assess accuracy of needle identification in real-time planning of ultrasound-guided high-dose-rate prostate implants","volume":"12","author":"Schmid","year":"2013","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2015.09.010_bib9","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1118\/1.1368127","article-title":"Inverse planning anatomy-based dose optimization for HDR-brachytherapy of the prostate using fast simulated annealing algorithm and dedicated objective function","volume":"28","author":"Lessard","year":"2001","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2015.09.010_bib10","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/j.brachy.2004.05.007","article-title":"Comparison of inverse\u00a0planning simulated annealing and geometrical optimization for prostate high-dose-rate brachytherapy","volume":"3","author":"Hsu","year":"2004","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2015.09.010_bib11","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/S0360-3016(02)02897-3","article-title":"Early clinical experience with anatomy-based inverse planning dose optimization for high-dose-rate boost of the prostate","volume":"54","author":"Lachance","year":"2002","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2015.09.010_bib12","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1016\/j.ijrobp.2008.02.009","article-title":"Anatomy-based inverse planning simulated annealing optimization in high-dose-rate prostate brachytherapy: significant dosimetric advantage over other optimization techniques","volume":"72","author":"Jacob","year":"2008","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2015.09.010_bib13","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.brachy.2007.10.001","article-title":"A comparison of anatomy-based inverse planning with simulated annealing and graphical optimization for high-dose-rate prostate brachytherapy","volume":"7","author":"Morton","year":"2008","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2015.09.010_bib14","doi-asserted-by":"crossref","first-page":"2263","DOI":"10.1088\/0031-9155\/47\/13\/306","article-title":"Multiobjective anatomy-based dose optimization for HDR-brachytherapy with constraint free deterministic algorithms","volume":"47","author":"Milickovic","year":"2002","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.brachy.2015.09.010_bib15","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1088\/0031-9155\/48\/3\/309","article-title":"A hybrid evolutionary algorithm for multi-objective anatomy-based dose optimization in high-dose-rate brachytherapy","volume":"48","author":"Lahanas","year":"2003","journal-title":"Phys Med Biol"},{"issue":"Suppl 2","key":"10.1016\/j.brachy.2015.09.010_bib16","doi-asserted-by":"crossref","first-page":"S29","DOI":"10.1016\/S0167-8140(05)81018-7","article-title":"HIPO: a hybrid inverse treatment planning optimization algorithm in HDR brachytherapy","volume":"76","author":"Karabis","year":"2005","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2015.09.010_bib17","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1007\/s12253-010-9252-z","article-title":"The effect of needle number on the quality of high-dose-rate prostate brachytherapy implants","volume":"16","author":"Fr\u00f6hlich","year":"2010","journal-title":"Pathol Oncol Res"},{"key":"10.1016\/j.brachy.2015.09.010_bib18","doi-asserted-by":"crossref","first-page":"882","DOI":"10.1097\/01.ju.0000169136.55891.21","article-title":"A new model using number of needles and androgen deprivation to predict chronic urinary toxicity for high or low dose rate prostate brachytherapy","volume":"174","author":"Vargas","year":"2005","journal-title":"J Urol"},{"key":"10.1016\/j.brachy.2015.09.010_bib19","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.prro.2013.02.011","article-title":"Dosimetric analysis of radiation therapy oncology group 0321: the importance of urethral dose","volume":"4","author":"Hsu","year":"2014","journal-title":"Pract Radiat Oncol"},{"key":"10.1016\/j.brachy.2015.09.010_bib20","doi-asserted-by":"crossref","first-page":"1392","DOI":"10.1016\/j.ijrobp.2004.01.041","article-title":"Correlating the degree of needle trauma during prostate brachytherapy and the development of acute urinary toxicity","volume":"59","author":"Eapen","year":"2004","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2015.09.010_bib21","doi-asserted-by":"crossref","first-page":"4339","DOI":"10.1118\/1.4728226","article-title":"NPIP: a skew line needle configuration optimization system for HDR brachytherapy","volume":"39","author":"Siauw","year":"2012","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2015.09.010_bib22","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1088\/0031-9155\/58\/4\/1041","article-title":"Mixed integer programming improves comprehensibility and plan quality in inverse optimization of prostate HDR brachytherapy","volume":"58","author":"Gorissen","year":"2013","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.brachy.2015.09.010_bib23","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.brachy.2008.02.236","article-title":"Catheters optimization within inverse planning simulated annealing for high-dose-rate brachytherapy","volume":"7","author":"Ayotte","year":"2008","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2015.09.010_bib24","first-page":"1","article-title":"Heuristics for integrated optimization of catheter positioning and dwell time distribution in prostate HDR brachytherapy","author":"Holm","year":"2013","journal-title":"Ann Oper Res"},{"key":"10.1016\/j.brachy.2015.09.010_bib25","doi-asserted-by":"crossref","first-page":"4198","DOI":"10.1120\/jacmp.v14i4.4198","article-title":"Evaluation of hybrid inverse planning and optimization (HIPO) algorithm for optimization in real-time, high-dose-rate (HDR) brachytherapy for prostate","volume":"14","author":"Pokharel","year":"2013","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.brachy.2015.09.010_bib26","doi-asserted-by":"crossref","first-page":"111724","DOI":"10.1118\/1.4826335","article-title":"Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy","volume":"40","author":"Poulin","year":"2013","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2015.09.010_bib27","series-title":"A Handbook for the optimization and optimization tools in SWIFT Version 3.0 (Oncentra Prostate)","author":"Baltas","year":"2007"},{"key":"10.1016\/j.brachy.2015.09.010_bib28","unstructured":"Giannouli S, Baltas D. Hybrid inverse planning optimization for brachytherapy treatment planning.\u00a02014. Available at: http:\/\/blog.elekta.com\/blog\/2014\/06\/white-paper-on-hipo-in-oncentra-brachy\/."},{"key":"10.1016\/j.brachy.2015.09.010_bib29","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.brachy.2011.09.008","article-title":"American Brachytherapy Society consensus guidelines for high-dose-rate prostate brachytherapy","volume":"11","author":"Yamada","year":"2012","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2015.09.010_bib30","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1016\/j.radonc.2015.02.007","article-title":"Towards real-time 3D ultrasound planning and personalized 3D printing for breast HDR brachytherapy treatment","volume":"114","author":"Poulin","year":"2015","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2015.09.010_bib31","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1118\/1.1646040","article-title":"Update of AAPM Task Group No. 43 Report: a revised AAPM protocol for brachytherapy dose calculations","volume":"31","author":"Rivard","year":"2004","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2015.09.010_bib32","doi-asserted-by":"crossref","first-page":"5055","DOI":"10.1120\/jacmp.v15i6.5055","article-title":"Comparison of IPSA and HIPO inverse planning optimization algorithms for prostate HDR brachytherapy","volume":"15","author":"Panettieri","year":"2014","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.brachy.2015.09.010_bib33","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/j.brachy.2014.09.006","article-title":"A comparison of inverse optimization algorithms for HDR\/PDR prostate brachytherapy treatment planning","volume":"14","author":"Dinkla","year":"2015","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2015.09.010_bib34","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/j.brachy.2009.09.003","article-title":"Prostate gland edema after single-fraction high-dose rate brachytherapy before external beam radiation therapy","volume":"9","author":"Cury","year":"2010","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2015.09.010_bib35","doi-asserted-by":"crossref","first-page":"1227","DOI":"10.1118\/1.4908011","article-title":"Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system","volume":"42","author":"Poulin","year":"2015","journal-title":"Med Phys"},{"issue":"Suppl 1","key":"10.1016\/j.brachy.2015.09.010_bib36","doi-asserted-by":"crossref","first-page":"S126","DOI":"10.1016\/j.brachy.2014.02.439","article-title":"Customized needle guides for inserting non-parallel needle arrangements in prostate HDR brachytherapy: a phantom study","volume":"13","author":"Siauw","year":"2014","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2015.09.010_bib37","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.brachy.2005.10.003","article-title":"Robotically assisted prostate brachytherapy with transrectal ultrasound guidance\u2014Phantom experiments","volume":"5","author":"Fichtinger","year":"2006","journal-title":"Brachytherapy"}],"container-title":["Brachytherapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1538472115005619?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1538472115005619?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T02:09:12Z","timestamp":1761530952000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1538472115005619"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,1]]},"references-count":37,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2016,1]]}},"alternative-id":["S1538472115005619"],"URL":"https:\/\/doi.org\/10.1016\/j.brachy.2015.09.010","relation":{},"ISSN":["1538-4721"],"issn-type":[{"value":"1538-4721","type":"print"}],"subject":[],"published":{"date-parts":[[2016,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of dose and catheter optimization algorithms in prostate high-dose-rate brachytherapy","name":"articletitle","label":"Article Title"},{"value":"Brachytherapy","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.brachy.2015.09.010","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}