{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T14:33:59Z","timestamp":1773671639617,"version":"3.50.1"},"reference-count":34,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2016,9,1]],"date-time":"2016-09-01T00:00:00Z","timestamp":1472688000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2016,9,1]],"date-time":"2016-09-01T00:00:00Z","timestamp":1472688000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["brachyjournal.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Brachytherapy"],"published-print":{"date-parts":[[2016,9]]},"DOI":"10.1016\/j.brachy.2016.06.004","type":"journal-article","created":{"date-parts":[[2016,7,27]],"date-time":"2016-07-27T17:37:28Z","timestamp":1469641048000},"page":"562-569","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":9,"title":["Clinical feasibility of interstitial brachytherapy using a \u201chybrid\u201d applicator combining uterine tandem and interstitial metal needles based on CT for locally advanced cervical cancer"],"prefix":"10.1016","volume":"15","author":[{"given":"Zhong-Shan","family":"Liu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jie","family":"Guo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xia","family":"Lin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hong-Yong","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ling","family":"Qiu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiao-Jun","family":"Ren","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yun-Feng","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bing-Ya","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tie-Jun","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.brachy.2016.06.004_bib1","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/0360-3016(94)90148-1","article-title":"The relationship between brachytherapy dose and outcome in patients with bulky endocervical tumors treated with radiation alone","volume":"28","author":"Eifel","year":"1994","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2016.06.004_bib2","doi-asserted-by":"crossref","first-page":"1144","DOI":"10.1056\/NEJM199904153401502","article-title":"Concurrent cisplatin-based radiotherapy and chemotherapy for locally advanced cervical cancer","volume":"340","author":"Rose","year":"1999","journal-title":"N Engl J Med"},{"key":"10.1016\/j.brachy.2016.06.004_bib3","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1056\/NEJM199904153401501","article-title":"Pelvic radiation with concurrent chemotherapy compared with pelvic and para-aortic radiation for high-risk cervical cancer","volume":"340","author":"Morris","year":"1999","journal-title":"N Engl J Med"},{"key":"10.1016\/j.brachy.2016.06.004_bib4","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/j.ijrobp.2013.11.011","article-title":"Curative radiation therapy for locally advanced cervical cancer: Brachytherapy is NOT optional","volume":"88","author":"Tanderup","year":"2014","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2016.06.004_bib5","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1016\/j.brachy.2003.06.001","article-title":"Radiography-based treatment planning compared with computed tomography (CT)-based treatment planning for intracavitary brachytherapy in cancer of the cervix: Analysis of dose-volume histograms","volume":"2","author":"Kim","year":"2003","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2016.06.004_bib6","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1016\/j.brachy.2004.07.001","article-title":"Is simulation necessary for each high-dose-rate tandem and ovoid insertion in carcinoma of the cervix?","volume":"3","author":"Jones","year":"2004","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2016.06.004_bib7","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/j.ijrobp.2005.06.015","article-title":"CT-guided intracavitary radiotherapy for cervical cancer: Comparison of conventional point A plan with clinical target volume-based three-dimensional plan using dose-volume parameters","volume":"64","author":"Shin","year":"2006","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2016.06.004_bib8","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1016\/j.radonc.2010.10.002","article-title":"3D CT-based high-dose-rate brachytherapy for cervical cancer: Clinical impact on late rectal bleeding and local control","volume":"97","author":"Kang","year":"2010","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2016.06.004_bib9","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.radonc.2011.07.012","article-title":"Clinical outcome of protocol based image (MRI) guided adaptive brachytherapy combined with 3D conformal radiotherapy with or without chemotherapy in patients with locally advanced cervical cancer","volume":"100","author":"Potter","year":"2011","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2016.06.004_bib10","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1016\/j.radonc.2012.04.007","article-title":"Impact of 3d image-based PDR brachytherapy on outcome of patients treated for cervix carcinoma in France: Results of the French STIC prospective study","volume":"103","author":"Charra-Brunaud","year":"2012","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2016.06.004_bib11","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.radonc.2004.12.015","article-title":"Recommendations from gynaecological (GYN) GEC-ESTRO working group (i): Concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV","volume":"74","author":"Haie-Meder","year":"2005","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2016.06.004_bib12","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.radonc.2005.11.014","article-title":"Recommendations from gynaecological (GYN) GEC ESTRO working group (ii): Concepts and terms in 3D image-based treatment planning in cervix cancer brachytherapy-3D dose volume parameters and aspects of 3D image-based anatomy, radiation physics, radiobiology","volume":"78","author":"Potter","year":"2006","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2016.06.004_bib13","doi-asserted-by":"crossref","first-page":"901","DOI":"10.1016\/j.ijrobp.2005.02.040","article-title":"Dose and volume parameters for MRI-based treatment planning in intracavitary brachytherapy for cervical cancer","volume":"62","author":"Kirisits","year":"2005","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2016.06.004_bib14","doi-asserted-by":"crossref","first-page":"756","DOI":"10.1016\/j.ijrobp.2007.10.032","article-title":"MRI-guided 3d optimization significantly improves DVH parameters of pulsed-dose-rate brachytherapy in locally advanced cervical cancer","volume":"71","author":"Lindegaard","year":"2008","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2016.06.004_bib15","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1148\/radiology.189.2.8210395","article-title":"Cervical cancer: Application of MR imaging in radiation therapy","volume":"189","author":"Mayr","year":"1993","journal-title":"Radiology"},{"key":"10.1016\/j.brachy.2016.06.004_bib16","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1016\/j.ijrobp.2015.03.010","article-title":"Image-based brachytherapy for the treatment of cervical Cancer","volume":"92","author":"Harkenrider","year":"2015","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2016.06.004_bib17","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1016\/j.ijrobp.2014.06.005","article-title":"Comparison and consensus guidelines for delineation of clinical target volume for CT- and MR-based brachytherapy in locally advanced cervical cancer","volume":"90","author":"Viswanathan","year":"2014","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2016.06.004_bib18","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/j.ijrobp.2006.12.021","article-title":"Computed tomography versus magnetic resonance imaging-based contouring in cervical cancer brachytherapy: Results of a prospective trial and preliminary guidelines for standardized contours","volume":"68","author":"Viswanathan","year":"2007","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2016.06.004_bib19","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1016\/j.ijrobp.2006.01.036","article-title":"The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer: Design, application, treatment planning, and dosimetric results","volume":"65","author":"Kirisits","year":"2006","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2016.06.004_bib20","doi-asserted-by":"crossref","first-page":"1424","DOI":"10.1016\/j.ijrobp.2011.04.044","article-title":"Clinical use of the Utrecht applicator for combined intracavitary\/interstitial brachytherapy treatment in locally advanced cervical cancer","volume":"82","author":"Nomden","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2016.06.004_bib21","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1269\/jrr.10091","article-title":"Intracavitary combined with CT-guided interstitial brachytherapy for locally advanced uterine cervical cancer: Introduction of the technique and a case presentation","volume":"52","author":"Wakatsuki","year":"2011","journal-title":"J Radiat Res"},{"key":"10.1016\/j.brachy.2016.06.004_bib22","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.ijgo.2009.02.009","article-title":"Revised FIGO staging for carcinoma of the cervix","volume":"105","author":"Pecorelli","year":"2009","journal-title":"Int J Gynaecol Obstet"},{"key":"10.1016\/j.brachy.2016.06.004_bib23","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1016\/0360-3016(84)90016-6","article-title":"A multiple-site perineal applicator (MUPIT) for treatment of prostatic, anorectal, and gynecologic malignancies","volume":"10","author":"Martinez","year":"1984","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2016.06.004_bib24","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1016\/S0360-3016(96)00373-2","article-title":"CT-guided interstitial implantation of gynecologic malignancies","volume":"36","author":"Erickson","year":"1996","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2016.06.004_bib25","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1016\/S0360-3016(01)02691-8","article-title":"A comparison between tandem and ovoids and interstitial gynecologic template brachytherapy dosimetry using a hypothetical computer model","volume":"52","author":"Hsu","year":"2002","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2016.06.004_bib26","doi-asserted-by":"crossref","first-page":"S51","DOI":"10.1016\/j.brachy.2010.02.071","article-title":"New Vienna applicator design for distal parametrial disease in cervical cancer","volume":"9","author":"Berger","year":"2010","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2016.06.004_bib27","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/j.radonc.2013.01.010","article-title":"Clinical feasibility of combined intracavitary\/interstitial brachytherapy in locally advanced cervical cancer employing MRI with a tandem\/ring applicator in situ and virtual preplanning of the interstitial component","volume":"107","author":"Fokdal","year":"2013","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2016.06.004_bib28","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/j.brachy.2012.01.004","article-title":"Counterpoint: Time to retire the parametrial boost","volume":"11","author":"Lindegaard","year":"2012","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2016.06.004_bib29","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1016\/j.brachy.2011.07.002","article-title":"American brachytherapy society consensus guidelines for locally advanced carcinoma of the cervix. Part II: High-dose-rate brachytherapy","volume":"11","author":"Viswanathan","year":"2012","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2016.06.004_bib30","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.ijrobp.2008.10.033","article-title":"Dose-volume histogram parameters and local tumor control in magnetic resonance image-guided cervical cancer brachytherapy","volume":"75","author":"Dimopoulos","year":"2009","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2016.06.004_bib31","doi-asserted-by":"crossref","first-page":"1446","DOI":"10.1016\/j.ijrobp.2007.02.009","article-title":"Computed tomography-based high-dose-rate intracavitary brachytherapy for uterine cervical cancer: Preliminary demonstration of correlation between dose-volume parameters and rectal mucosal changes observed by flexible sigmoidoscopy","volume":"68","author":"Koom","year":"2007","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2016.06.004_bib32","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1016\/j.radonc.2010.05.005","article-title":"Dose volume parameter d2cc does not correlate with vaginal side effects in individual patients with cervical cancer treated within a defined treatment protocol with very high brachytherapy doses","volume":"97","author":"Fidarova","year":"2010","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2016.06.004_bib33","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1016\/j.radonc.2012.04.008","article-title":"Impact of dosimetric and clinical parameters on clinical side effects in cervix cancer patients treated with 3d pulse-dose-rate intracavitary brachytherapy","volume":"103","author":"Levitchi","year":"2012","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2016.06.004_bib34","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.ijrobp.2006.04.041","article-title":"The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer: Clinical feasibility and preliminary results","volume":"66","author":"Dimopoulos","year":"2006","journal-title":"Int J Radiat Oncol Biol Phys"}],"container-title":["Brachytherapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1538472116304950?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1538472116304950?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T02:10:13Z","timestamp":1761531013000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1538472116304950"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,9]]},"references-count":34,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2016,9]]}},"alternative-id":["S1538472116304950"],"URL":"https:\/\/doi.org\/10.1016\/j.brachy.2016.06.004","relation":{},"ISSN":["1538-4721"],"issn-type":[{"value":"1538-4721","type":"print"}],"subject":[],"published":{"date-parts":[[2016,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Clinical feasibility of interstitial brachytherapy using a \u201chybrid\u201d applicator combining uterine tandem and interstitial metal needles based on CT for locally advanced cervical cancer","name":"articletitle","label":"Article Title"},{"value":"Brachytherapy","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.brachy.2016.06.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}