{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,20]],"date-time":"2026-01-20T00:54:51Z","timestamp":1768870491894,"version":"3.49.0"},"reference-count":16,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["brachyjournal.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Brachytherapy"],"published-print":{"date-parts":[[2018,1]]},"DOI":"10.1016\/j.brachy.2017.01.013","type":"journal-article","created":{"date-parts":[[2017,3,7]],"date-time":"2017-03-07T03:02:58Z","timestamp":1488855778000},"page":"24-30","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["An evaluation of our experience in position verification of catheters used for interstitial high-dose-rate brachytherapy of solitary bladder tumors"],"prefix":"10.1016","volume":"17","author":[{"given":"S.J.E.A.","family":"Bus","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N.G.","family":"Leus","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.J.","family":"Oosterveld","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.P.R.","family":"Van Gellekom","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.J.M.","family":"van de Loop","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E.M.","family":"van der Steen-Banasik","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.brachy.2017.01.013_bib1","doi-asserted-by":"crossref","first-page":"622","DOI":"10.1016\/S0360-3016(02)02739-6","article-title":"Saving bladders with brachytherapy: implantation technique and results","volume":"53","author":"Van der Steen-Banasik","year":"2002","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2017.01.013_bib2","doi-asserted-by":"crossref","first-page":"1439","DOI":"10.1016\/j.ijrobp.2016.03.029","article-title":"The Curie-Da Vinci connection: 5-years\u2019 experience with laparoscopic (Robot-Assisted) implantation for high-dose-rate brachytherapy of solitary T2 bladder tumors","volume":"95","author":"Van der Steen-Banasik","year":"2016","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2017.01.013_bib3","doi-asserted-by":"crossref","first-page":"313","DOI":"10.5114\/jcb.2014.45492","article-title":"Interstitial brachytherapy for bladder cancer with the aid of laparoscopy","volume":"6","author":"Nap-van Klinken","year":"2014","journal-title":"J Contemp Brachyther"},{"key":"10.1016\/j.brachy.2017.01.013_bib4","article-title":"GEC-ESTRO\/ACROP recommendations for performing bladder-sparing treatment with brachytherapy for muscle-invasive bladder carcinoma","author":"Pieters","year":"2016","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2017.01.013_bib5","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/0360-3016(91)90149-X","article-title":"Quantitative assessment of interstitial implants","volume":"20","author":"Saw","year":"1991","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2017.01.013_bib6","series-title":"Brachytherapy from radium to optimization","first-page":"300","article-title":"Evaluation and optimization of interstitial brachytherapy dose distribution","author":"Meertens","year":"1994"},{"key":"10.1016\/j.brachy.2017.01.013_bib7","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.radonc.2013.11.002","article-title":"Review of clinical brachytherapy uncertainties: analysis guidelines of GEC-ESTRO and the AAPM","volume":"110","author":"Kirisits","year":"2014","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2017.01.013_bib8","doi-asserted-by":"crossref","first-page":"1063","DOI":"10.1016\/j.ijrobp.2003.08.020","article-title":"Analysis of serial CT scans to assess template and catheter movement in prostate HDR brachytherapy","volume":"58","author":"Mullokandov","year":"2004","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2017.01.013_bib9","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1016\/S0360-3016(99)00477-0","article-title":"Needle displacement during HDR brachytherapy in the treatment of prostate cancer","volume":"46","author":"Damore","year":"2000","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2017.01.013_bib10","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1016\/S0167-8140(03)00203-2","article-title":"High dose rate afterloading brachytherapy for prostate cancer: catheter and gland movement between fractions","volume":"68","author":"Hoskin","year":"2003","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2017.01.013_bib11","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1016\/j.radonc.2011.08.004","article-title":"Prostate HDR brachytherapy catheter displacement between planning and treatment delivery","volume":"101","author":"Whitaker","year":"2011","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2017.01.013_bib12","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1016\/j.brachy.2010.11.007","article-title":"Use of cone-beam imaging to correct for catheter displacement in high dose-rate prostate brachytherapy","volume":"10","author":"Holly","year":"2011","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2017.01.013_bib13","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1016\/j.radonc.2009.09.015","article-title":"Justification for inter-fraction correction of catheter movement in fractionated high dose-rate brachytherapy treatment of prostate cancer","volume":"93","author":"Simnor","year":"2009","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2017.01.013_bib14","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1016\/j.radonc.2010.12.009","article-title":"HDR monotherapy for prostate cancer: a simulation study to determine the effect of catheter displacement on target coverage and normal tissue irradiation","volume":"98","author":"Kolkman-Deurloo","year":"2011","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2017.01.013_bib15","doi-asserted-by":"crossref","first-page":"e617","DOI":"10.1016\/j.ijrobp.2011.11.018","article-title":"Quality assurance of multifractionated pelvic interstitial brachytherapy for postoperative recurrences of cervical cancers: a prospective study","volume":"82","author":"Shukla","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2017.01.013_bib16","doi-asserted-by":"crossref","first-page":"93","DOI":"10.5114\/jcb.2010.16919","article-title":"Positional variation of applicators during low dose rate intracavitary brachytherapy for cervical cancer: a prospective study","volume":"2","author":"Koushik","year":"2010","journal-title":"J Contemp Brachyther"}],"container-title":["Brachytherapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1538472117300193?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1538472117300193?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T02:12:28Z","timestamp":1761531148000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1538472117300193"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1]]},"references-count":16,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,1]]}},"alternative-id":["S1538472117300193"],"URL":"https:\/\/doi.org\/10.1016\/j.brachy.2017.01.013","relation":{},"ISSN":["1538-4721"],"issn-type":[{"value":"1538-4721","type":"print"}],"subject":[],"published":{"date-parts":[[2018,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"An evaluation of our experience in position verification of catheters used for interstitial high-dose-rate brachytherapy of solitary bladder tumors","name":"articletitle","label":"Article Title"},{"value":"Brachytherapy","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.brachy.2017.01.013","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}