{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T19:04:54Z","timestamp":1782932694131,"version":"3.54.5"},"reference-count":44,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T00:00:00Z","timestamp":1746057600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T00:00:00Z","timestamp":1746057600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100015375","name":"The Affiliated Hospital of Southwest Medical University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100015375","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100014895","name":"Southwest Medical University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100014895","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["brachyjournal.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Brachytherapy"],"published-print":{"date-parts":[[2025,5]]},"DOI":"10.1016\/j.brachy.2024.12.007","type":"journal-article","created":{"date-parts":[[2025,1,31]],"date-time":"2025-01-31T11:52:57Z","timestamp":1738324377000},"page":"371-378","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Quality control study of cervical cancer interstitial brachytherapy treatment plans using statistical process control"],"prefix":"10.1016","volume":"24","author":[{"given":"Xiao","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiangxiang","family":"Shi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huaiwen","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4877-9343","authenticated-orcid":false,"given":"Haowen","family":"Pang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.brachy.2024.12.007_bib0001","doi-asserted-by":"crossref","first-page":"733","DOI":"10.2460\/javma.258.7.733","article-title":"Introduction to statistical quality control","volume":"258","author":"Freeman","year":"2021","journal-title":"J Am Vet Med Assoc"},{"key":"10.1016\/j.brachy.2024.12.007_bib0002","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1080\/10408363.2022.2088685","article-title":"Technical quality assurance and quality control for medical laboratories: a review and proposal of a new concept to obtain integrated and validated QA\/QC plans","volume":"59","author":"van Rossum","year":"2022","journal-title":"Crit Rev Clin Lab Sci"},{"key":"10.1016\/j.brachy.2024.12.007_bib0003","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1093\/ajcp\/aqy162","article-title":"Establishing commonsense-based statistical quality control practices","volume":"151","author":"Yago","year":"2019","journal-title":"Am J Clin Pathol"},{"key":"10.1016\/j.brachy.2024.12.007_bib0004","doi-asserted-by":"crossref","first-page":"1368","DOI":"10.1002\/mp.15458","article-title":"Knowledge-based quality control of organ delineations in radiation therapy","volume":"49","author":"Nourzadeh","year":"2022","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2024.12.007_bib0005","doi-asserted-by":"crossref","first-page":"2777","DOI":"10.1118\/1.2001209","article-title":"Statistical process control for radiotherapy quality assurance[J]","volume":"32","author":"Pawlicki","year":"2005","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2024.12.007_bib0006","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/s11864-018-0564-7","article-title":"Quality control of radiation delivery for lower gastrointestinal cancers","volume":"19","author":"Jain","year":"2018","journal-title":"Curr Treat Options Oncol"},{"key":"10.1016\/j.brachy.2024.12.007_bib0007","doi-asserted-by":"crossref","first-page":"e168","DOI":"10.1002\/mp.13445","article-title":"Radiation therapy quality assurance tasks and tools: The many roles of machine learning","volume":"47","author":"Kalet","year":"2020","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2024.12.007_bib0008","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1016\/j.canrad.2021.05.004","article-title":"Improving intensity-modulated radiation therapy quality assurance by adopting statistical process control","volume":"26","author":"Cui","year":"2022","journal-title":"Cancer Radiother"},{"key":"10.1016\/j.brachy.2024.12.007_bib0009","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1016\/j.cali.2010.04.004","article-title":"El control estad\u00edstico de proceso puede ayudar a prevenir los errores de tratamiento sin aumentar los costes en radioterapia [Statistical Process Control (SPC) can help prevent treatment errors without increasing costs in radiotherapy]","volume":"25","author":"Govindarajan","year":"2010","journal-title":"Rev Calid Asist"},{"key":"10.1016\/j.brachy.2024.12.007_bib0010","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1111\/j.1365-2753.2009.01213.x","article-title":"Statistical process control as a tool for controlling operating room performance: Retrospective analysis and benchmarking","volume":"16","author":"Chen","year":"2010","journal-title":"J Eval Clin Pract"},{"key":"10.1016\/j.brachy.2024.12.007_bib0011","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20170289","article-title":"Predicting the dose absorbed by organs at risk during intensity modulated radiation therapy for nasopharyngeal carcinoma","volume":"91","author":"Pang","year":"2018","journal-title":"Br J Radiol"},{"key":"10.1016\/j.brachy.2024.12.007_bib0012","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1002\/acm2.12331","article-title":"A quality control method for intensity-modulated radiation therapy planning based on generalized equivalent uniform dose","volume":"19","author":"Pang","year":"2018","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.brachy.2024.12.007_bib0013","doi-asserted-by":"crossref","first-page":"2760","DOI":"10.1002\/mp.13526","article-title":"Knowledge-based planning for intensity-modulated radiation therapy: a review of data-driven approaches","volume":"46","author":"Ge","year":"2019","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2024.12.007_bib0014","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1186\/s12885-023-10875-6","article-title":"Dose prediction of organs at risk in patients with cervical cancer receiving brachytherapy using needle insertion based on a neural network method","volume":"23","author":"Zhang","year":"2023","journal-title":"BMC Cancer"},{"key":"10.1016\/j.brachy.2024.12.007_bib0015","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.radonc.2022.02.022","article-title":"Multi-center analysis of machine-learning predicted dose parameters in brachytherapy for cervical cancer[J]","volume":"170","author":"Reijtenbagh","year":"2022","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2024.12.007_bib0016","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/j.radonc.2017.01.012","article-title":"Cross-institutional knowledge-based planning (KBP) implementation and its performance comparison to auto-planning engine (APE)","volume":"123","author":"Wu","year":"2017","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2024.12.007_bib0017","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1186\/s12885-023-10875-6","article-title":"Dose prediction of organs at risk in patients with cervical cancer receiving brachytherapy using needle insertion based on a neural network method","volume":"23","author":"Zhang","year":"2023","journal-title":"BMC Cancer"},{"issue":"8","key":"10.1016\/j.brachy.2024.12.007_bib0018","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1002\/acm2.12917","article-title":"Predictive quality assurance of a linear accelerator based on the machine performance check application using statistical process control and ARIMA forecast modeling","volume":"21","author":"Puyati","year":"2020","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.brachy.2024.12.007_bib0019","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/j.radonc.2018.01.006","article-title":"Review of the patient positioning reproducibility in head-and-neck radiotherapy using statistical process control","volume":"127","author":"Moore","year":"2018","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2024.12.007_bib0020","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejmp.2023.102651","article-title":"Moving towards process-based radiotherapy quality assurance using statistical process control","volume":"112","author":"Raveendran","year":"2023","journal-title":"Phys Med"},{"key":"10.1016\/j.brachy.2024.12.007_bib0021","doi-asserted-by":"crossref","first-page":"1811","DOI":"10.1002\/mp.12859","article-title":"Image-guided radiotherapy quality control: sstatistical process control using image similarity metrics","volume":"45","author":"Shiraishi","year":"2018","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2024.12.007_bib0022","doi-asserted-by":"crossref","first-page":"4694","DOI":"10.1002\/mp.14399","article-title":"Statistical process control and process capability analysis for non-normal volumetric modulated arc therapy patient-specific quality assurance processes","volume":"47","author":"Xiao","year":"2020","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2024.12.007_bib0023","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1016\/j.ejmp.2021.08.007","article-title":"Performance assessment of surface-guided radiation therapy and patient setup in head-and-neck and breast cancer patients based on statistical process control","volume":"89","author":"Li","year":"2021","journal-title":"Phys Med"},{"issue":"3","key":"10.1016\/j.brachy.2024.12.007_bib0024","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1002\/acm2.12547","article-title":"A multi-institutional evaluation of machine performance check system on treatment beam output and symmetry using statistical process control","volume":"20","author":"Binny","year":"2019","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.brachy.2024.12.007_bib0025","article-title":"Automated contouring and statistical process control for plan quality in a breast clinical trial","volume":"28","author":"Baroudi","year":"2023","journal-title":"Phys Imaging Radiat Oncol"},{"key":"10.1016\/j.brachy.2024.12.007_bib0026","doi-asserted-by":"crossref","first-page":"102651","DOI":"10.1016\/j.ejmp.2023.102651","article-title":"Moving towards process-based radiotherapy quality assurance using statistical process control","volume":"112","author":"Raveendran","year":"2023","journal-title":"Phys Med"},{"key":"10.1016\/j.brachy.2024.12.007_bib0027","doi-asserted-by":"crossref","first-page":"828","DOI":"10.1016\/j.ijrobp.2012.05.016","article-title":"Quality control of high-dose-rate brachytherapy: Treatment delivery analysis using statistical process control","volume":"85","author":"Able","year":"2013","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2024.12.007_bib0028","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1016\/j.brachy.2011.07.002","article-title":"The American brachy\u2011therapy society treatment recommendations for locally advanced carci\u2011noma of the cervix Part II: High dose-rate brachytherapy","volume":"11","author":"Viswanathan","year":"2012","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2024.12.007_bib0029","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1002\/acm2.13195","article-title":"Comparison of two inverse planning algorithms for cervical cancer brachytherapy","volume":"22","author":"Fu","year":"2021","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.brachy.2024.12.007_bib0030","doi-asserted-by":"crossref","first-page":"354","DOI":"10.5114\/jcb.2022.119513","article-title":"Control charts for evaluation of quality of low-dose-rate brachytherapy for prostate cancer","volume":"14","author":"Nasser","year":"2022","journal-title":"J Contemp Brachyther"},{"key":"10.1016\/j.brachy.2024.12.007_bib0031","doi-asserted-by":"crossref","first-page":"2118","DOI":"10.1002\/mp.14795","article-title":"Treatment plan quality control using multivariate control charts","volume":"48","author":"Roy","year":"2021","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2024.12.007_bib0032","first-page":"347","article-title":"Basic process capability indices: An expository review","volume":"76","author":"Anis","year":"2008","journal-title":"IntStat Rev"},{"key":"10.1016\/j.brachy.2024.12.007_bib0033","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1080\/08982110008962614","article-title":"Capability indices for non-normal data[J]","volume":"12","author":"McCormack","year":"2000","journal-title":"Qual Engineering"},{"key":"10.1016\/j.brachy.2024.12.007_bib0034","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.brachy.2018.08.007","article-title":"Comparison of two iodine-125 brachytherapy implant techniques for the treatment of lung tumor: Preplanning and intraoperative planning","volume":"18","author":"Li","year":"2019","journal-title":"Brachytherapy"},{"issue":"6","key":"10.1016\/j.brachy.2024.12.007_bib0035","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1016\/j.brachy.2024.06.004","article-title":"Comparison of 3D-printed multichannel non-co-planar vaginal applicators and single-channel vaginal applicators for brachytherapy with positive or close surgical margins in cervical cancer","volume":"23","author":"Feng","year":"2024","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2024.12.007_bib0036","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1016\/j.canrad.2022.10.006","article-title":"Plan quality score to evaluate the dwell time deviation restricted inverse planning by simulated annealing and graphically optimized treatment plans for template based interstitial brachytherapy","volume":"27","author":"Mondal","year":"2023","journal-title":"Cancer Radiother"},{"key":"10.1016\/j.brachy.2024.12.007_bib0037","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.brachy.2011.07.003","article-title":"American brachytherapy society cervical cancer recommendations committee. American Brachytherapy Society consensus guidelines for locally advanced carcinoma of the cervix. Part I: General principles[J]","volume":"11","author":"Viswanathan","year":"2012","journal-title":"Brachytherapy,"},{"key":"10.1016\/j.brachy.2024.12.007_bib0038","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1016\/j.ijrobp.2006.01.036","article-title":"The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer: Design, application, treatment planning, and dosimetric results","volume":"65","author":"Kirisits","year":"2006","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2024.12.007_bib0039","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/j.radonc.2014.11.045","article-title":"Impact of treatment time and dose escalation on local control in locally advanced cervical cancer treated by chemoradiation and image-guided pulsed-dose rate adaptive brachytherapy","volume":"114","author":"Mazeron","year":"2015","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2024.12.007_bib0040","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1016\/j.ijrobp.2014.10.053","article-title":"MRI-guided high-dose-rate intracavitary brachytherapy for treatment of cervical cancer: The University of Pitts\u2011burgh experience","volume":"91","author":"Gill","year":"2015","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2024.12.007_bib0041","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1016\/j.ijrobp.2014.11.014","article-title":"Evaluation of a knowledge-based planning solution for head and neck cancer","volume":"91","author":"Tol","year":"2015","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2024.12.007_bib0042","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.meddos.2020.12.002","article-title":"Why all radiotherapy planning studies are wrong but some are useful","volume":"46","author":"Eaton","year":"2021","journal-title":"Med Dosim"},{"key":"10.1016\/j.brachy.2024.12.007_bib0043","doi-asserted-by":"crossref","first-page":"733","DOI":"10.2460\/javma.258.7.733","article-title":"Introduction to statistical quality control","volume":"258","author":"Freeman","year":"2021","journal-title":"J Am Vet Med Assoc"},{"key":"10.1016\/j.brachy.2024.12.007_bib0044","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1016\/j.radonc.2011.11.016","article-title":"Control chart analysis of data from a multicenter monitor unit verification study","volume":"102","author":"Nordstr\u00f6m","year":"2012","journal-title":"Radiother Oncol"}],"container-title":["Brachytherapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1538472125000054?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1538472125000054?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T21:08:52Z","timestamp":1762549732000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1538472125000054"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5]]},"references-count":44,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,5]]}},"alternative-id":["S1538472125000054"],"URL":"https:\/\/doi.org\/10.1016\/j.brachy.2024.12.007","relation":{},"ISSN":["1538-4721"],"issn-type":[{"value":"1538-4721","type":"print"}],"subject":[],"published":{"date-parts":[[2025,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Quality control study of cervical cancer interstitial brachytherapy treatment plans using statistical process control","name":"articletitle","label":"Article Title"},{"value":"Brachytherapy","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.brachy.2024.12.007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 American Brachytherapy Society. Published by Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}