{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T00:39:24Z","timestamp":1776818364808,"version":"3.51.2"},"reference-count":28,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T00:00:00Z","timestamp":1761004800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["brachyjournal.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Brachytherapy"],"published-print":{"date-parts":[[2026,5]]},"DOI":"10.1016\/j.brachy.2025.10.003","type":"journal-article","created":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T03:03:39Z","timestamp":1775444619000},"page":"455-464","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["An integrated endotracheal brachytherapy system: Engineering validation and dosimetric advantages"],"prefix":"10.1016","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-8143-1927","authenticated-orcid":false,"given":"Jerome","family":"Jean-Joseph","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christoph","family":"Westerhausen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Florian","family":"Gerheuser","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tilman","family":"Janzen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Georg","family":"Stueben","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria","family":"Neu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nikolaos","family":"Balagiannis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.brachy.2025.10.003_bib0001","doi-asserted-by":"crossref","first-page":"18","DOI":"10.21037\/med-22-65","article-title":"Airway stenting for central airway obstruction: a review","volume":"7","author":"Sabath","year":"2023","journal-title":"Mediastinum"},{"issue":"6","key":"10.1016\/j.brachy.2025.10.003_bib0002","doi-asserted-by":"crossref","first-page":"1473","DOI":"10.1378\/chest.11-2005","article-title":"Respiratory infections increase the risk of granulation tissue formation following airway stenting in patients with malignant airway obstruction","volume":"141","author":"Ost","year":"2012","journal-title":"Chest"},{"key":"10.1016\/j.brachy.2025.10.003_bib0003","doi-asserted-by":"crossref","first-page":"39","DOI":"10.4103\/2156-7514.119021","article-title":"Adenoid cystic carcinoma of the upper trachea: a rare neoplasm","volume":"3","author":"Choudhury","year":"2013","journal-title":"J Clin Imaging Sci"},{"key":"10.1016\/j.brachy.2025.10.003_bib0004","series-title":"AJCC cancer staging manual","author":"Amin","year":"2017"},{"key":"10.1016\/j.brachy.2025.10.003_bib0005","doi-asserted-by":"crossref","unstructured":"Fritz, P. et al. A new applicator, positionable to the center of tracheobronchial lumen for HDR-IR-192-afterloading of tracheobronchial tumors International Journal of Radiation Oncology, Biology, Physics, Vol. 20, no. 5, 1061\u20131066","DOI":"10.1016\/0360-3016(91)90205-I"},{"key":"10.1016\/j.brachy.2025.10.003_sbref0006","series-title":"Handbook of brachytherapy","first-page":"731","article-title":"GEC-ESTRO bronchus cancer","author":"Gerbaulet","year":"2017"},{"key":"10.1016\/j.brachy.2025.10.003_bib0007","doi-asserted-by":"crossref","DOI":"10.1063\/5.0202322","article-title":"3D reconstruction from CT images utilizing the open-source tool","volume":"3094","author":"Shiaa","year":"2024","journal-title":"AIP Conf Proc"},{"key":"10.1016\/j.brachy.2025.10.003_bib0008","doi-asserted-by":"crossref","first-page":"1402","DOI":"10.1111\/anae.12026","article-title":"Size matters: choosing the right tracheal tube","volume":"67","author":"Mir","year":"2012","journal-title":"Anaesthesia"},{"key":"10.1016\/j.brachy.2025.10.003_bib0009","doi-asserted-by":"crossref","DOI":"10.3389\/fsurg.2023.1125997","article-title":"Post-intubation iatrogenic tracheobronchial injuries: the state of art","volume":"10","author":"Passera","year":"2023","journal-title":"Front Surg"},{"key":"10.1016\/j.brachy.2025.10.003_bib0010","series-title":"Technical Data Sheet no. 2001403 Rev 01 [Internet]","article-title":"Dental LT Clear Resin","year":"2020"},{"key":"10.1016\/j.brachy.2025.10.003_bib0011","series-title":"Reduced Order Methods for Modeling and Computational Reduction","first-page":"235","article-title":"Model order reduction in fluid dynamics: challenges and perspectives","author":"Lassila","year":"2014"},{"key":"10.1016\/j.brachy.2025.10.003_bib0012","series-title":"22nd AIAA Computational Fluid Dynamics Conference","article-title":"Tetrahedral-mesh simulation of turbulent flows with the space-time conservative schemes","author":"Chang","year":"2015"},{"key":"10.1016\/j.brachy.2025.10.003_bib0013","series-title":"Proceedings of the 31st International Conference on Nuclear Engineering","article-title":"Study of compressible flow in pipes containing mesh structures","author":"Xu","year":"2024"},{"key":"10.1016\/j.brachy.2025.10.003_bib0014","series-title":"Computational fluid dynamics","first-page":"15","article-title":"Navier-Stokes equations","author":"Kollmann","year":"2024"},{"issue":"2","key":"10.1016\/j.brachy.2025.10.003_bib0015","first-page":"209","article-title":"Evaluation of the tracheal stenosis effects on airway resistance and work of breathing using computational fluid dynamics","volume":"22","author":"Monjezi","year":"2023","journal-title":"Tanaffos"},{"key":"10.1016\/j.brachy.2025.10.003_bib0016","volume":"13485","year":"2016"},{"key":"10.1016\/j.brachy.2025.10.003_bib0017","volume":"14971","year":"2019"},{"key":"10.1016\/j.brachy.2025.10.003_bib0018","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1186\/s12938-022-01054-y","article-title":"Investigation on forced vibration characteristics of Nitinol tracheal stent","volume":"21","author":"Bao","year":"2022","journal-title":"Biomed Eng Online"},{"issue":"12","key":"10.1016\/j.brachy.2025.10.003_bib0019","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1002\/acm2.13063","article-title":"Development of an HDR-BT QA tool for source position verification","volume":"21","author":"Kumazaki","year":"2020","journal-title":"J Appl Clin Med Phys"},{"issue":"1","key":"10.1016\/j.brachy.2025.10.003_bib0020","doi-asserted-by":"crossref","first-page":"33","DOI":"10.5114\/jcb.2025.147780","article-title":"Auxetic solution for enhanced esophageal brachytherapy applicator","volume":"17","author":"Jean-Joseph","year":"2025","journal-title":"J Contemp Brachytherapy"},{"issue":"18","key":"10.1016\/j.brachy.2025.10.003_bib0021","doi-asserted-by":"crossref","first-page":"1301","DOI":"10.1056\/NEJM200005043421801","article-title":"Ventilation with lower TV as compared with traditional TV for acute lung injury and the acute respiratory distress syndrome","volume":"342","author":"Brower","year":"2000","journal-title":"N Engl J Med"},{"issue":"7","key":"10.1016\/j.brachy.2025.10.003_bib0022","first-page":"856","article-title":"The effect of PEEP on pulmonary vascular resistance depends on lung recruitability in ARDS patients","volume":"210","author":"Borlino","year":"2024","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1016\/j.brachy.2025.10.003_bib0023","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1007\/978-3-319-19387-8_113","article-title":"Impact of inhomogeneity corrected dose calculation of clinical brachytherapy sites","volume":"51","author":"Jamema","year":"2015","journal-title":"IFMBE Proc"},{"issue":"2","key":"10.1016\/j.brachy.2025.10.003_bib0024","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1159\/000479225","article-title":"Advanced tracheal adenoid cystic carcinoma with thyroid invasion mimicking thyroid cancer treated with definitive radiation: case report and review of the literature","volume":"10","author":"Al Khatib","year":"2017","journal-title":"Case Rep Oncol"},{"key":"10.1016\/j.brachy.2025.10.003_bib0025","unstructured":"European Parliament and Council. Regulation (EU) 2017\/745 on medical devices. Off J Eur Union. 2017; L 117:1\u2013175"},{"key":"10.1016\/j.brachy.2025.10.003_bib0026","series-title":"Off J Eur Union","first-page":"1","article-title":"Regulation (EU) 2024\/1689 laying down harmonised rules on artificial intelligence (Artificial Intelligence Act)","year":"2024"},{"key":"10.1016\/j.brachy.2025.10.003_bib0027","unstructured":"European Parliament and Council. Directive (EU) 2019\/904 on the reduction of the impact of certain plastic products on the environment. Off J Eur Union. 2019; L 155:1\u201319."},{"issue":"11","key":"10.1016\/j.brachy.2025.10.003_bib0028","article-title":"Development and validation of the Augsburg Nasopharyngeal applicator: enhancing efficacy in Nasal route brachytherapy","volume":"10","author":"Jean-Joseph","year":"2025","journal-title":"Adv Radiat Oncol"}],"container-title":["Brachytherapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1538472125003241?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1538472125003241?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T23:44:08Z","timestamp":1776815048000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1538472125003241"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5]]},"references-count":28,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,5]]}},"alternative-id":["S1538472125003241"],"URL":"https:\/\/doi.org\/10.1016\/j.brachy.2025.10.003","relation":{},"ISSN":["1538-4721"],"issn-type":[{"value":"1538-4721","type":"print"}],"subject":[],"published":{"date-parts":[[2026,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"An integrated endotracheal brachytherapy system: Engineering validation and dosimetric advantages","name":"articletitle","label":"Article Title"},{"value":"Brachytherapy","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.brachy.2025.10.003","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Authors. Published by Elsevier Inc. on behalf of American Brachytherapy Society.","name":"copyright","label":"Copyright"}]}}