{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T11:39:10Z","timestamp":1792841950929,"version":"4.5.0"},"reference-count":51,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["brachyjournal.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Brachytherapy"],"published-print":{"date-parts":[[2026,11]]},"DOI":"10.1016\/j.brachy.2026.07.176","type":"journal-article","created":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T11:21:27Z","timestamp":1788780087000},"page":"1049-1059","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Dosimetric comparison of HDR Co-60 and Ir-192 brachytherapy sources by model-based dose calculation algorithms and its clinical implication in different brachytherapy sites and techniques"],"prefix":"10.1016","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8583-8157","authenticated-orcid":false,"given":"Raghavendra","family":"Hajare","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rohit Avinash","family":"Vadgaonkar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taushiful","family":"Hoque","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Atyant Kumar","family":"Hota","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2913-2149","authenticated-orcid":false,"given":"Sreelakshmi","family":"K K","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kiriti","family":"Chiriki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raviteja","family":"Miriyala","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2815-8083","authenticated-orcid":false,"given":"Christian","family":"Kirisits","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Umesh","family":"Mahantshetty","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.brachy.2026.07.176_bib0001","first-page":"1","article-title":"International conference on advances in radiation oncology (ICARO): outcomes of an IAEA meeting","volume":"6","author":"Salminen","year":"2011","journal-title":"Rad Oncol"},{"key":"10.1016\/j.brachy.2026.07.176_bib0002","doi-asserted-by":"crossref","first-page":"132","DOI":"10.4103\/0019-509X.180856","article-title":"Resolving the brachytherapy challenges with government funded hospital","volume":"53","author":"Nikam","year":"2016","journal-title":"Indian J Cancer"},{"key":"10.1016\/j.brachy.2026.07.176_bib0003","doi-asserted-by":"crossref","first-page":"199","DOI":"10.5114\/jcb.2011.26471","article-title":"Comparison of 60 Co and 192 Ir sources in HDR brachytherapy","volume":"3","author":"Strohmaier","year":"2011","journal-title":"J Contemp Brachyther"},{"key":"10.1016\/j.brachy.2026.07.176_bib0004","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1007\/s00066-008-1684-y","article-title":"Comparison of 60cobalt and 192iridium sources in high dose rate afterloading brachytherapy","volume":"184","author":"Richter","year":"2008","journal-title":"Strahlenther Onkol"},{"key":"10.1016\/j.brachy.2026.07.176_bib0005","doi-asserted-by":"crossref","first-page":"52","DOI":"10.5114\/jcb.2012.27952","article-title":"Treatment planning study of the 3D dosimetric differences between Co-60 and Ir-192 sources in high dose rate (HDR) brachytherapy for cervix cancer","volume":"4","author":"Palmer","year":"2012","journal-title":"J Contemp Brachyther"},{"key":"10.1016\/j.brachy.2026.07.176_bib0006","doi-asserted-by":"crossref","first-page":"4749","DOI":"10.3390\/cancers14194749","article-title":"Comparative analysis of 60co and 192ir sources in high dose rate brachytherapy for cervical cancer","volume":"14","author":"Wen","year":"2022","journal-title":"Cancers"},{"key":"10.1016\/j.brachy.2026.07.176_bib0007","doi-asserted-by":"crossref","first-page":"1426","DOI":"10.1016\/j.apradiso.2009.02.066","article-title":"A comparison of dose distributions of HDR intracavitary brachytherapy using different sources and treatment planning systems","volume":"67","author":"Park","year":"2009","journal-title":"Appl Rad Isotop"},{"key":"10.1016\/j.brachy.2026.07.176_bib0008","doi-asserted-by":"crossref","first-page":"73","DOI":"10.5114\/jcb.2018.74327","article-title":"A comparative assessment of inhomogeneity and finite patient dimension effects in 60 Co and 192 Ir high-dose-rate brachytherapy","volume":"10","author":"Fotina","year":"2018","journal-title":"J Contemp Brachyther"},{"key":"10.1016\/j.brachy.2026.07.176_bib0009","doi-asserted-by":"crossref","first-page":"1409","DOI":"10.1007\/s12094-017-1670-x","article-title":"Gynecological brachytherapy for postoperative endometrial cancer: dosimetric analysis (Ir-192 vs Co-60)","volume":"19","author":"Tormo Ferrero","year":"2017","journal-title":"Clin Transl Oncol"},{"key":"10.1016\/j.brachy.2026.07.176_bib0010","doi-asserted-by":"crossref","first-page":"191","DOI":"10.4103\/jcrt.JCRT_199_19","article-title":"Estimation and comparison of integral dose to target and organs at risk in three-dimensional computed tomography image-based treatment planning of carcinoma uterine cervix with two high-dose-rate brachytherapy sources: 60: Co and: 192: Ir","volume":"17","author":"Yadav","year":"2021","journal-title":"J Cancer Res Therapeut"},{"issue":"5","key":"10.1016\/j.brachy.2026.07.176_bib0011","doi-asserted-by":"crossref","first-page":"e86","DOI":"10.3802\/jgo.2018.29.e86","article-title":"Treatment outcomes of high-dose-rate intracavitary brachytherapy for cervical cancer: a comparison of Ir-192 versus Co-60 sources","volume":"29","author":"Tantivatana","year":"2018","journal-title":"Journal of Gynecologic Oncology"},{"key":"10.1016\/j.brachy.2026.07.176_bib0012","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/j.rpor.2016.01.003","article-title":"Dosimetric analysis of Co-60 source based high dose rate (HDR) brachytherapy: a case series of ten patients with carcinoma of the uterine cervix","volume":"21","author":"Gurjar","year":"2016","journal-title":"Rep Pract Oncol Radiother"},{"key":"10.1016\/j.brachy.2026.07.176_bib0013","doi-asserted-by":"crossref","first-page":"219","DOI":"10.4103\/0971-6203.103608","article-title":"Dosimetric comparison between the microSelectron HDR 192Ir v2 source and the BEBIG 60Co source for HDR brachytherapy using the EGSnrc Monte Carlo transport code","volume":"37","author":"Islam","year":"2012","journal-title":"J Med Phys"},{"key":"10.1016\/j.brachy.2026.07.176_bib0014","doi-asserted-by":"crossref","DOI":"10.1016\/j.radphyschem.2022.110148","article-title":"Determination of variation in dosimetric parameters of treatment planning with Co-60 and Ir-192 sources in high dose rate brachytherapy of cervical carcinoma","volume":"196","author":"Srivastava","year":"2022","journal-title":"Rad Phys Chem"},{"key":"10.1016\/j.brachy.2026.07.176_bib0015","doi-asserted-by":"crossref","DOI":"10.1088\/2057-1976\/ac1c52","article-title":"High dose rate 192Ir versus high dose rate 60Co brachytherapy: an overview of systematic reviews of clinical responses of gynecological cancers from 1984 to 2020","volume":"7","author":"Abtahi","year":"2021","journal-title":"Biomed Phys Eng Express"},{"key":"10.1016\/j.brachy.2026.07.176_bib0016","doi-asserted-by":"crossref","first-page":"141","DOI":"10.5114\/jcb.2023.126238","article-title":"Dosimetric comparison between microSelectron iridium-192 and flexi cobalt-60 sources in high-dose-rate brachytherapy using Geant4 Monte Carlo code","volume":"15","author":"Gebremariam","year":"2023","journal-title":"J Contemp Brachyther"},{"key":"10.1016\/j.brachy.2026.07.176_bib0017","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1118\/1.595297","article-title":"Some theoretical derivations relating to the tissue dosimetry of brachytherapy nuclides, with particular reference to iodine-125","volume":"10","author":"Dale","year":"1983","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2026.07.176_bib0018","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1118\/1.597811","article-title":"Measurement and calculation of the dose at large distances from brachytherapy sources: Cs-137, Ir-192, and Co-60","volume":"23","author":"Venselaar","year":"1996","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2026.07.176_bib0019","doi-asserted-by":"crossref","first-page":"5263","DOI":"10.1118\/1.3002312","article-title":"On the use of HDR source with the MammoSite\u00ae Radiation Therapy System","volume":"35","author":"Baltas","year":"2008","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2026.07.176_bib0020","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1016\/j.rpor.2016.03.005","article-title":"Study of the dosimetric differences between Ir and Co sources of high dose rate brachytherapy for breast interstitial implant","volume":"21","author":"Sinnatamby","year":"2016","journal-title":"Rep Pract Oncol Radiother"},{"key":"10.1016\/j.brachy.2026.07.176_bib0021","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1118\/1.1646040","article-title":"Update of AAPM Task Group No. 43 Report: a revised AAPM protocol for brachytherapy dose calculations","volume":"31","author":"Rivard","year":"2004","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2026.07.176_bib0022","doi-asserted-by":"crossref","first-page":"6208","DOI":"10.1118\/1.4747264","article-title":"Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: current status and recommendations for clinical implementation","volume":"39","author":"Beaulieu","year":"2012","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2026.07.176_bib0023","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1017\/S1460396919000220","article-title":"Evaluation of BrachyDose Monte Carlo code for HDR brachytherapy: dose comparison against Acuros\u00ae BV and TG-43 algorithms","volume":"19","author":"Dagli","year":"2020","journal-title":"J Radiother Pract"},{"key":"10.1016\/j.brachy.2026.07.176_bib0024","doi-asserted-by":"crossref","first-page":"939","DOI":"10.1016\/j.brachy.2015.08.003","article-title":"Validation of the Oncentra Brachy Advanced Collapsed cone Engine for a commercial 192Ir source using heterogeneous geometries","volume":"14","author":"Ma","year":"2015","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2026.07.176_bib0025","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1002\/pro6.1170","article-title":"Dosimetric comparison of AcurosBV with AAPM TG43 dose calculation formalism in cervical intraductal high-dose-rate brachytherapy using three different applicators","volume":"6","author":"Bi","year":"2022","journal-title":"Precis Rad Oncol"},{"key":"10.1016\/j.brachy.2026.07.176_bib0026","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1007\/s13246-021-01029-8","article-title":"A review of dosimetric impact of implementation of model-based dose calculation algorithms (MBDCAs) for HDR brachytherapy","volume":"44","author":"Yousif","year":"2021","journal-title":"Phys Eng Sci Med"},{"key":"10.1016\/j.brachy.2026.07.176_bib0027","doi-asserted-by":"crossref","first-page":"143","DOI":"10.5114\/jcb.2016.59352","article-title":"Impact of heterogeneity-corrected dose calculation using a grid-based Boltzmann solver on breast and cervix cancer brachytherapy","volume":"8","author":"Hofbauer","year":"2016","journal-title":"J Contemp Brachyther"},{"key":"10.1016\/j.brachy.2026.07.176_bib0028","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1093\/jrr\/rrx081","article-title":"Impact of a commercially available model-based dose calculation algorithm on treatment planning of high-dose-rate brachytherapy in patients with cervical cancer","volume":"59","author":"Abe","year":"2018","journal-title":"J Rad Res"},{"key":"10.1016\/j.brachy.2026.07.176_bib0029","doi-asserted-by":"crossref","DOI":"10.1118\/1.4770275","article-title":"Dosimetric accuracy of a deterministic radiation transport based 192Ir brachytherapy treatment planning system. Part III. Comparison to Monte Carlo simulation in voxelized anatomical computational models","volume":"40","author":"Zourari","year":"2013","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2026.07.176_bib0030","first-page":"5475","article-title":"Performance evaluation of a collapsed cone dose calculation algorithm for HDR Ir-192 of APBI treatments","volume":"44","author":"Terribilini","year":"2017","journal-title":"MedPhys"},{"key":"10.1016\/j.brachy.2026.07.176_bib0031","doi-asserted-by":"crossref","first-page":"273","DOI":"10.5114\/jcb.2015.54052","article-title":"Dosimetric comparison of Acuros TM BV with AAPM TG43 dose calculation formalism in breast interstitial high-dose-rate brachytherapy with the use of metal catheters","volume":"7","author":"Sinnatamby","year":"2015","journal-title":"J Contemp Brachyther"},{"key":"10.1016\/j.brachy.2026.07.176_bib0032","doi-asserted-by":"crossref","first-page":"669","DOI":"10.1016\/j.ejmp.2015.05.010","article-title":"A retrospective dosimetric comparison of TG43 and a commercially available MBDCA for an APBI brachytherapy patient cohort","volume":"31","author":"Zourari","year":"2015","journal-title":"Phys Med"},{"key":"10.1016\/j.brachy.2026.07.176_bib0033","doi-asserted-by":"crossref","first-page":"1200","DOI":"10.1016\/j.ijrobp.2021.02.034","article-title":"Characterization of dosimetric differences in strut-adjusted volume implant treatment plans calculated with TG-43 formalism and a model-based dose calculation algorithm","volume":"110","author":"Mazur","year":"2021","journal-title":"Int J Rad Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2026.07.176_bib0034","doi-asserted-by":"crossref","first-page":"1520","DOI":"10.1016\/j.ijrobp.2016.03.033","article-title":"Comparison of dose distributions with TG-43 and collapsed cone convolution algorithms applied to accelerated partial breast irradiation patient plans","volume":"95","author":"Thrower","year":"2016","journal-title":"Int J Rad Oncol Biol Phys"},{"key":"10.1016\/j.brachy.2026.07.176_bib0035","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1016\/j.brachy.2020.11.013","article-title":"Comparison of TG43 and Hounsfield Unit\u2013based TG186 brachytherapy dose metrics in Oncentra Brachy for 100 patients receiving interstitial partial breast irradiation","volume":"20","author":"Howie","year":"2021","journal-title":"Brachytherapy"},{"key":"10.1016\/j.brachy.2026.07.176_bib0036","series-title":"Oncentra Brachy v4.6 physics and algorithms for: 170730 Oncentra external beam Oncentra brachy","year":"2018"},{"key":"10.1016\/j.brachy.2026.07.176_bib0037","doi-asserted-by":"crossref","first-page":"34","DOI":"10.5114\/jcb.2012.27950","article-title":"Monte Carlo dosimetric study of the Flexisource Co-60 high dose rate source","volume":"4","author":"Vijande","year":"2012","journal-title":"J Contemp Brachyther"},{"key":"10.1016\/j.brachy.2026.07.176_bib0038","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1016\/j.apradiso.2018.02.016","article-title":"A Monte Carlo investigation of the dose distribution for 60Co high dose rate brachytherapy source in water and in different media","volume":"136","author":"Badry","year":"2018","journal-title":"Appl Rad Isotopes"},{"key":"10.1016\/j.brachy.2026.07.176_bib0039","doi-asserted-by":"crossref","DOI":"10.1118\/1.4791647","article-title":"Calculated organ doses using Monte Carlo simulations in a reference male phantom undergoing HDR brachytherapy applied to localized prostate carcinoma","volume":"40","author":"Candela-Juan","year":"2013","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2026.07.176_bib0040","doi-asserted-by":"crossref","first-page":"4426","DOI":"10.1002\/mp.12335","article-title":"Comparison of 192Ir, 169Yb, and 60Co high-dose rate brachytherapy sources for skin cancer treatment","volume":"44","author":"Safigholi","year":"2017","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2026.07.176_bib0041","doi-asserted-by":"crossref","first-page":"4578","DOI":"10.1118\/1.2388154","article-title":"A dosimetric study on the Ir 192 high dose rate Flexisource","volume":"33","author":"Granero","year":"2006","journal-title":"Med Phys"},{"key":"10.1016\/j.brachy.2026.07.176_bib0042","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1016\/j.radonc.2021.05.010","article-title":"IBS-GEC ESTRO-ABS recommendations for CT based contouring in image guided adaptive brachytherapy for cervical cancer","volume":"160","author":"Mahantshetty","year":"2021","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2026.07.176_bib0043","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1016\/j.radonc.2010.01.014","volume":"94","author":"Polg\u00e1r","year":"2010","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2026.07.176_bib0044","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.radonc.2015.12.006","article-title":"Recommendations from GEC ESTRO Breast Cancer Working Group (II): target definition and target delineation for accelerated or boost partial breast irradiation using multicatheter interstitial brachytherapy after breast conserving open cavity surgery","volume":"118","author":"Major","year":"2016","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.brachy.2026.07.176_bib0045","doi-asserted-by":"crossref","first-page":"501","DOI":"10.5114\/jcb.2020.100385","article-title":"Brachytherapy in head and neck malignancies: Indian Brachytherapy Society (IBS) recommendations and guidelines","volume":"12","author":"Bhalavat","year":"2020","journal-title":"J Contemp Brachyther"},{"key":"10.1016\/j.brachy.2026.07.176_bib0046","first-page":"33","article-title":"The Paris system in interstitial radiation therapy","volume":"17","author":"Pierquin","year":"1978","journal-title":"Acta Radiol"},{"key":"10.1016\/j.brachy.2026.07.176_bib0047","volume":"13","year":"2013"},{"key":"10.1016\/j.brachy.2026.07.176_bib0048","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1186\/s13014-022-02170-8","article-title":"Radiobiological and dosimetric comparison of 60Co versus 192Ir high-dose-rate intracavitary-interstitial brachytherapy for cervical cancer","volume":"17","author":"Wen","year":"2022","journal-title":"Rad Oncol"},{"key":"10.1016\/j.brachy.2026.07.176_bib0049","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1007\/s12194-017-0418-1","article-title":"Assessment of dose uniformity around high dose rate 192 Ir and 60 Co stepping sources","volume":"10","author":"Farhood","year":"2017","journal-title":"Radiol Phys Technol"},{"key":"10.1016\/j.brachy.2026.07.176_bib0050","doi-asserted-by":"crossref","first-page":"232","DOI":"10.5114\/jcb.2013.39444","article-title":"Head and neck 192 Ir HDR-brachytherapy dosimetry using a grid-based Boltzmann solver","volume":"5","author":"Siebert","year":"2013","journal-title":"J Contemp Brachyther"},{"key":"10.1016\/j.brachy.2026.07.176_bib0051","doi-asserted-by":"crossref","first-page":"S146","DOI":"10.1016\/j.brachy.2016.04.257","article-title":"Assessment of volumetric dose differences between calculations performed with the advanced collapsed cone engine (ACE) for the model-based dose calculation method (TG-186), TG-43, and Monte Carlo","volume":"15","author":"Han","year":"2016","journal-title":"Brachytherapy"}],"container-title":["Brachytherapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1538472126002825?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1538472126002825?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T11:33:31Z","timestamp":1792841611000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1538472126002825"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,11]]},"references-count":51,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026,11]]}},"alternative-id":["S1538472126002825"],"URL":"https:\/\/doi.org\/10.1016\/j.brachy.2026.07.176","relation":{},"ISSN":["1538-4721"],"issn-type":[{"value":"1538-4721","type":"print"}],"subject":[],"published":{"date-parts":[[2026,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Dosimetric comparison of HDR Co-60 and Ir-192 brachytherapy sources by model-based dose calculation algorithms and its clinical implication in different brachytherapy sites and techniques","name":"articletitle","label":"Article Title"},{"value":"Brachytherapy","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.brachy.2026.07.176","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 American Brachytherapy Society. Published by Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}