{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T00:20:50Z","timestamp":1758846050694,"version":"3.44.0"},"reference-count":22,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,3,1]],"date-time":"2025-03-01T00:00:00Z","timestamp":1740787200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,3,1]],"date-time":"2025-03-01T00:00:00Z","timestamp":1740787200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,1,10]],"date-time":"2025-01-10T00:00:00Z","timestamp":1736467200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["18K08934","22K09226"],"award-info":[{"award-number":["18K08934","22K09226"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Brain Research"],"published-print":{"date-parts":[[2025,3]]},"DOI":"10.1016\/j.brainres.2025.149443","type":"journal-article","created":{"date-parts":[[2025,1,2]],"date-time":"2025-01-02T14:50:31Z","timestamp":1735829431000},"page":"149443","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Identifying the appropriate measurement environment for laser speckle flowmetry of cerebral blood flow in rats"],"prefix":"10.1016","volume":"1850","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-1772-4004","authenticated-orcid":false,"given":"Ryosei","family":"Wakasa","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takahiro","family":"Ono","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5761-1596","authenticated-orcid":false,"given":"Naomoto","family":"Senbokuya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mikiko","family":"Kuwayama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5738-1332","authenticated-orcid":false,"given":"Hiroaki","family":"Shimizu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.brainres.2025.149443_b0005","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1097\/01.WCB.0000122745.72175.D5","article-title":"Laser speckle flowmetry for the study of cerebrovascular physiology in normal and ischemic mouse cortex","volume":"24","author":"Ayata","year":"2004","journal-title":"J. Cereb. Blood Flow Metab."},{"key":"10.1016\/j.brainres.2025.149443_b0010","doi-asserted-by":"crossref","first-page":"1172","DOI":"10.1097\/01.WCB.0000137057.92786.F3","article-title":"Pronounced hypoperfusion during spreading depression in mouse cortex","volume":"24","author":"Ayata","year":"2004","journal-title":"J. Cereb. Blood Flow Metab."},{"issue":"1","key":"10.1016\/j.brainres.2025.149443_b0015","doi-asserted-by":"crossref","DOI":"10.1117\/1.3285504","article-title":"Laser speckle contrast imaging in biomedical optics","volume":"15","author":"Boas","year":"2010","journal-title":"J. Biomed. Opt."},{"issue":"8","key":"10.1016\/j.brainres.2025.149443_b0020","doi-asserted-by":"crossref","DOI":"10.1117\/1.JBO.19.8.086001","article-title":"Imaging depth and multiple scattering in laser speckle contrast imaging","volume":"19","author":"Davis","year":"2014","journal-title":"J. Biomed. Opt."},{"key":"10.1016\/j.brainres.2025.149443_b0025","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1097\/00004647-200103000-00002","article-title":"Dynamic imaging of cerebral blood flow using laser speckle","volume":"21","author":"Dunn","year":"2001","journal-title":"J. Cereb. Blood Flow Metab."},{"key":"10.1016\/j.brainres.2025.149443_b0030","doi-asserted-by":"crossref","first-page":"2938","DOI":"10.1161\/STROKEAHA.110.596379","article-title":"Early protective effect of bone marrow mononuclear cells against ischemic white matter damage through augmentation of cerebral blood flow","volume":"41","author":"Fujita","year":"2010","journal-title":"Stroke"},{"key":"10.1016\/j.brainres.2025.149443_b0035","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1038\/bmt.2012.244","article-title":"Investigation of the freely available easy-to-use software \u2018EZR\u2019 for medical statistics","volume":"48","author":"Kanda","year":"2013","journal-title":"Bone Marrow Transplant."},{"key":"10.1016\/j.brainres.2025.149443_b0040","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/0030-3992(94)90039-6","article-title":"Non-contact laser tissue blood flow measurement using polarization to reduce the specular reflection artefact","volume":"26","author":"Kashima","year":"1994","journal-title":"Opt. Laser Technol."},{"key":"10.1016\/j.brainres.2025.149443_b0045","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1038\/jcbfm.2010.128","article-title":"Distinct spatiotemporal patterns of spreading depolarizations during early infarct evolution: evidence from real-time imaging","volume":"31","author":"Kumagai","year":"2011","journal-title":"J. Cereb. Blood Flow Metab."},{"issue":"8","key":"10.1016\/j.brainres.2025.149443_b0050","doi-asserted-by":"crossref","DOI":"10.1117\/1.3610995","article-title":"Functional laser speckle imaging of cerebral blood flow under hypothermia","volume":"16","author":"Li","year":"2011","journal-title":"J. Biomed. Opt."},{"key":"10.1016\/j.brainres.2025.149443_b0055","doi-asserted-by":"crossref","first-page":"892","DOI":"10.3171\/2018.3.JNS172274","article-title":"A refined model of chronic cerebral hypoperfusion resulting in cognitive impairment and a low mortality rate in rats","volume":"131","author":"Mansour","year":"2019","journal-title":"J. Neurosurg."},{"key":"10.1016\/j.brainres.2025.149443_b0060","doi-asserted-by":"crossref","first-page":"9998","DOI":"10.1073\/pnas.90.21.9998","article-title":"Characterization of functional organization within rat barrel cortex using intrinsic signal optical imaging through a thinned skull","volume":"90","author":"Masino","year":"1993","journal-title":"PNAS"},{"key":"10.1016\/j.brainres.2025.149443_b0065","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1016\/j.expneurol.2011.11.025","article-title":"Cerebral blood flow during reperfusion predicts later brain damage in a mouse and a rat model of neonatal hypoxic\u2013ischemic encephalopathy","volume":"233","author":"Ohshima","year":"2012","journal-title":"Exp. Neurol."},{"issue":"3","key":"10.1016\/j.brainres.2025.149443_b0070","doi-asserted-by":"crossref","first-page":"1975","DOI":"10.1364\/OE.16.001975","article-title":"Robust flow measurement with multi-exposure speckle imaging","volume":"16","author":"Parthasarathy","year":"2008","journal-title":"Opt. Express"},{"key":"10.1016\/j.brainres.2025.149443_b0075","doi-asserted-by":"crossref","DOI":"10.1016\/j.brainres.2023.148231","article-title":"Improving accuracy of cerebral blood flow measurements in laser speckle flowmetry","volume":"1803","author":"Senbokuya","year":"2023","journal-title":"Brain Res."},{"issue":"10","key":"10.1016\/j.brainres.2025.149443_b0080","doi-asserted-by":"crossref","first-page":"2200","DOI":"10.1016\/j.jstrokecerebrovasdis.2015.04.048","article-title":"Visualization of regional cerebral blood flow dynamics during cortical venous occlusion using laser speckle contrast imaging in a rat model","volume":"24","author":"Takeshima","year":"2015","journal-title":"J. Stroke Cerebrovasc. Dis."},{"key":"10.1016\/j.brainres.2025.149443_b0085","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1109\/RBME.2016.2532598","article-title":"Laser speckle imaging to monitor microvascular blood flow: A review","volume":"9","author":"Vaz","year":"2016","journal-title":"IEEE Rev. Biomed. Eng."},{"key":"10.1016\/j.brainres.2025.149443_b0090","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/aa9f3a","article-title":"Effect of static scatterers in laser speckle contrast imaging: An experimental study on correlation and contrast","volume":"63","author":"Vaz","year":"2017","journal-title":"Phys. Med. Biol."},{"key":"10.1016\/j.brainres.2025.149443_b0095","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1038\/sj.jcbfm.9600357","article-title":"Theoretical and experimental optimization of laser speckle contrast imaging for high specificity to brain microcirculation","volume":"27","author":"Wang","year":"2007","journal-title":"J.cereb. Blood Flow Metab."},{"issue":"2","key":"10.1016\/j.brainres.2025.149443_b0100","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1038\/nprot.2009.222","article-title":"Thinned-skull cranial window technique for long-term imaging of the cortex in live mice","volume":"5","author":"Yang","year":"2010","journal-title":"Nat. Protoc."},{"issue":"23","key":"10.1016\/j.brainres.2025.149443_b0105","doi-asserted-by":"crossref","first-page":"3465","DOI":"10.1364\/OL.31.003465","article-title":"Quantitative modeling of laser speckle imaging","volume":"31","author":"Zakharov","year":"2006","journal-title":"Opt. Lett."},{"key":"10.1016\/j.brainres.2025.149443_b0110","doi-asserted-by":"crossref","first-page":"13904","DOI":"10.1364\/OE.17.013904","article-title":"Dynamic laser speckle imaging of cerebral blood flow","volume":"17","author":"Zakharov","year":"2009","journal-title":"Opt. Express"}],"container-title":["Brain Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0006899325000010?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0006899325000010?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,25]],"date-time":"2025-09-25T16:18:41Z","timestamp":1758817121000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0006899325000010"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3]]},"references-count":22,"alternative-id":["S0006899325000010"],"URL":"https:\/\/doi.org\/10.1016\/j.brainres.2025.149443","relation":{},"ISSN":["0006-8993"],"issn-type":[{"type":"print","value":"0006-8993"}],"subject":[],"published":{"date-parts":[[2025,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Identifying the appropriate measurement environment for laser speckle flowmetry of cerebral blood flow in rats","name":"articletitle","label":"Article Title"},{"value":"Brain Research","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.brainres.2025.149443","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Authors. Published by Elsevier B.V.","name":"copyright","label":"Copyright"}],"article-number":"149443"}}