{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T09:31:25Z","timestamp":1788600685909,"version":"build-2803163510"},"reference-count":87,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2021,12,1]],"date-time":"2021-12-01T00:00:00Z","timestamp":1638316800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,12,1]],"date-time":"2021-12-01T00:00:00Z","timestamp":1638316800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2021,9,20]],"date-time":"2021-09-20T00:00:00Z","timestamp":1632096000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Building and Environment"],"published-print":{"date-parts":[[2021,12]]},"DOI":"10.1016\/j.buildenv.2021.108347","type":"journal-article","created":{"date-parts":[[2021,9,20]],"date-time":"2021-09-20T14:30:05Z","timestamp":1632148205000},"page":"108347","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":39,"special_numbering":"C","title":["Multizonal modeling of SARS-CoV-2 aerosol dispersion in a virtual office building"],"prefix":"10.1016","volume":"206","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2733-695X","authenticated-orcid":false,"given":"Prateek","family":"Shrestha","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jason W.","family":"DeGraw","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mingkan","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaobing","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.buildenv.2021.108347_bib1","doi-asserted-by":"crossref","DOI":"10.1128\/mSphere.00637-20","article-title":"Effectiveness of face masks in preventing airborne transmission of SARS-CoV-2","volume":"5","author":"Ueki","year":"2020","journal-title":"mSphere"},{"key":"10.1016\/j.buildenv.2021.108347_bib2","doi-asserted-by":"crossref","first-page":"140540","DOI":"10.1016\/j.scitotenv.2020.140540","article-title":"SARS-CoV-2 RNA detection in the air and on surfaces in the COVID-19 ward of a hospital in Milan, Italy","volume":"742","author":"Razzini","year":"2020","journal-title":"Sci. Total Environ."},{"key":"10.1016\/j.buildenv.2021.108347_bib3","first-page":"1856","volume":"20","author":"Ahlawat","year":"2020"},{"key":"10.1016\/j.buildenv.2021.108347_bib4","doi-asserted-by":"crossref","first-page":"138401","DOI":"10.1016\/j.scitotenv.2020.138401","article-title":"A field indoor air measurement of SARS-CoV-2 in the patient rooms of the largest hospital in Iran","volume":"725","author":"Faridi","year":"2020","journal-title":"Sci. Total Environ."},{"key":"10.1016\/j.buildenv.2021.108347_bib5","doi-asserted-by":"crossref","first-page":"105794","DOI":"10.1016\/j.envint.2020.105794","article-title":"Estimation of airborne viral emission: quanta emission rate of SARS-CoV-2 for infection risk assessment","volume":"141","author":"Buonanno","year":"2020","journal-title":"Environ. Int."},{"key":"10.1016\/j.buildenv.2021.108347_bib6","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1001\/jama.2020.7603","article-title":"Airborne spread of SARS-CoV-2 and a potential role for air disinfection","volume":"324","author":"Nardell","year":"2020","journal-title":"J. Am. Med. Assoc."},{"key":"10.1016\/j.buildenv.2021.108347_bib7","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1111\/ina.12697","article-title":"Recognizing and controlling airborne transmission of SARS-CoV-2 in indoor environments","volume":"30","author":"Allen","year":"2020","journal-title":"Indoor Air"},{"key":"10.1016\/j.buildenv.2021.108347_bib8","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1038\/s41586-020-2271-3","article-title":"Aerodynamic analysis of SARS-CoV-2 in two Wuhan hospitals","volume":"582","author":"Liu","year":"2020","journal-title":"Nature"},{"key":"10.1016\/j.buildenv.2021.108347_bib9","doi-asserted-by":"crossref","first-page":"109861","DOI":"10.1016\/j.envres.2020.109861","article-title":"Influence of airborne transmission of SARS-CoV-2 on COVID-19 pandemic. A review","volume":"188","author":"Domingo","year":"2020","journal-title":"Environ. Res."},{"key":"10.1016\/j.buildenv.2021.108347_bib10","doi-asserted-by":"crossref","first-page":"109781","DOI":"10.1016\/j.mehy.2020.109781","article-title":"Airborne route and bad use of ventilation systems as non-negligible factors in SARS-CoV-2 transmission","volume":"141","author":"Correia","year":"2020","journal-title":"Med. Hypotheses"},{"key":"10.1016\/j.buildenv.2021.108347_bib11","doi-asserted-by":"crossref","first-page":"911","DOI":"10.4209\/aaqr.2020.04.0158","article-title":"A letter about the airborne transmission of SARS-CoV-2 based on the current evidence","volume":"20","author":"Hadei","year":"2020","journal-title":"Aerosol Air Qual. Res."},{"key":"10.1016\/j.buildenv.2021.108347_bib12","doi-asserted-by":"crossref","first-page":"106918","DOI":"10.1016\/j.buildenv.2020.106918","article-title":"Air purifiers: a supplementary measure to remove airborne SARS-CoV-2","volume":"177","author":"Zhao","year":"2020","journal-title":"Build. Environ."},{"key":"10.1016\/j.buildenv.2021.108347_bib13","doi-asserted-by":"crossref","first-page":"106112","DOI":"10.1016\/j.envint.2020.106112","article-title":"Quantitative assessment of the risk of airborne transmission of SARS-CoV-2 infection: prospective and retrospective applications","volume":"145","author":"Buonanno","year":"2020","journal-title":"Environ. Int."},{"issue":"80","key":"10.1016\/j.buildenv.2021.108347_bib14","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1126\/science.abf0521","article-title":"Airborne transmission of SARS-CoV-2","volume":"370","author":"Prather","year":"2020","journal-title":"Science"},{"key":"10.1016\/j.buildenv.2021.108347_bib15","doi-asserted-by":"crossref","first-page":"11875","DOI":"10.1073\/pnas.2006874117","article-title":"The airborne lifetime of small speech droplets and their potential importance in SARS-CoV-2 transmission","volume":"117","author":"Stadnytskyi","year":"2020","journal-title":"Proc. Natl. Acad. Sci. U.S.A."},{"key":"10.1016\/j.buildenv.2021.108347_bib16","doi-asserted-by":"crossref","first-page":"139178","DOI":"10.1016\/j.scitotenv.2020.139178","article-title":"On airborne transmission and control of SARS-Cov-2","volume":"731","author":"Yao","year":"2020","journal-title":"Sci. Total Environ."},{"key":"10.1016\/j.buildenv.2021.108347_bib17","doi-asserted-by":"crossref","first-page":"105730","DOI":"10.1016\/j.envint.2020.105730","article-title":"Airborne transmission of SARS-CoV-2: the world should face the reality","volume":"139","author":"Morawska","year":"2020","journal-title":"Environ. Int."},{"key":"10.1016\/j.buildenv.2021.108347_bib18","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1001\/jama.2020.12458","article-title":"Airborne transmission of SARS-CoV-2: theoretical considerations and available evidence","volume":"324","author":"Klompas","year":"2020","journal-title":"JAMA, J. Am. Med. Assoc."},{"key":"10.1016\/j.buildenv.2021.108347_bib19","doi-asserted-by":"crossref","first-page":"564","DOI":"10.1093\/infdis\/jiaa334","article-title":"Airborne SARS-CoV-2 is rapidly inactivated by simulated sunlight","volume":"222","author":"Schuit","year":"2020","journal-title":"J. Infect. Dis."},{"key":"10.1016\/j.buildenv.2021.108347_bib20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12199-020-00904-2","article-title":"Environmental factors involved in SARS-CoV-2 transmission: effect and role of indoor environmental quality in the strategy for COVID-19 infection control","volume":"25","author":"Azuma","year":"2020","journal-title":"Environ. Health Prev. Med."},{"key":"10.1016\/j.buildenv.2021.108347_bib21","doi-asserted-by":"crossref","first-page":"105832","DOI":"10.1016\/j.envint.2020.105832","article-title":"How can airborne transmission of COVID-19 indoors be minimised?","volume":"142","author":"Morawska","year":"2020","journal-title":"Environ. Int."},{"key":"10.1016\/j.buildenv.2021.108347_bib22","doi-asserted-by":"crossref","first-page":"106039","DOI":"10.1016\/j.envint.2020.106039","article-title":"Aerosol transmission of SARS-CoV-2? Evidence, prevention and control","volume":"144","author":"Tang","year":"2020","journal-title":"Environ. Int."},{"key":"10.1016\/j.buildenv.2021.108347_bib23","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/j.jhin.2020.12.022","article-title":"Dismantling myths on the airborne transmission of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2)","volume":"110","author":"Tang","year":"2021","journal-title":"J. Hosp. Infect."},{"key":"10.1016\/j.buildenv.2021.108347_bib24","article-title":"Safer singing during the SARS-CoV-2 pandemic: what we know and what we don't","author":"Naunheim","year":"2020","journal-title":"J. Voice"},{"key":"10.1016\/j.buildenv.2021.108347_bib25","article-title":"Aerial transmission of SARS-CoV-2 virus (and pathogens in general) through environmental e-cigarette aerosol","author":"Sussman","year":"2020","journal-title":"MedRxiv"},{"key":"10.1016\/j.buildenv.2021.108347_bib26","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1164\/rccm.202004-1263PP","article-title":"Coughs and sneezes: their role in transmission of respiratory viral infections, including SARS-CoV-2","volume":"202","author":"Dhand","year":"2020","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"10.1016\/j.buildenv.2021.108347_bib27","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/j.jes.2021.01.025","article-title":"Control of exhaled SARS-CoV-2-laden aerosols in the interpersonal breathing microenvironment in a ventilated room with limited space air stability","volume":"108","author":"Deng","year":"2021","journal-title":"J. Environ. Sci."},{"key":"10.1016\/j.buildenv.2021.108347_bib28","doi-asserted-by":"crossref","first-page":"2932","DOI":"10.3390\/ijerph17082932","article-title":"Airborne transmission route of COVID-19: why 2 meters\/6 feet of inter-personal distance could not Be enough","volume":"17","author":"Setti","year":"2020","journal-title":"Int. J. Environ. Res. Publ. Health"},{"key":"10.1016\/j.buildenv.2021.108347_bib29","doi-asserted-by":"crossref","first-page":"110343","DOI":"10.1016\/j.envres.2020.110343","article-title":"The role of air conditioning in the diffusion of Sars-CoV-2 in indoor environments: a first computational fluid dynamic model, based on investigations performed at the Vatican State Children's hospital","volume":"193","author":"Borro","year":"2021","journal-title":"Environ. Res."},{"key":"10.1016\/j.buildenv.2021.108347_bib30","doi-asserted-by":"crossref","DOI":"10.1063\/5.0043934","article-title":"Computer simulation of the SARS-CoV-2 contamination risk in a large dental clinic","volume":"33","author":"Komperda","year":"2021","journal-title":"Phys. Fluids"},{"key":"10.1016\/j.buildenv.2021.108347_bib31","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1016\/j.apm.2021.02.018","article-title":"Modeling airborne pathogen transport and transmission risks of SARS-CoV-2","volume":"95","author":"Ho","year":"2021","journal-title":"Appl. Math. Model."},{"key":"10.1016\/j.buildenv.2021.108347_bib32","doi-asserted-by":"crossref","first-page":"110612","DOI":"10.1016\/j.envres.2020.110612","article-title":"A systematic review of possible airborne transmission of the COVID-19 virus (SARS-CoV-2) in the indoor air environment","volume":"193","author":"Noorimotlagh","year":"2021","journal-title":"Environ. Res."},{"key":"10.1016\/j.buildenv.2021.108347_bib33","doi-asserted-by":"crossref","first-page":"104866","DOI":"10.1016\/j.ssci.2020.104866","article-title":"Modelling aerosol transport and virus exposure with numerical simulations in relation to SARS-CoV-2 transmission by inhalation indoors","volume":"130","author":"Vuorinen","year":"2020","journal-title":"Saf. Sci."},{"key":"10.1016\/j.buildenv.2021.108347_bib34","article-title":"Evidence for probable aerosol transmission of SARS-CoV-2 in a poorly ventilated restaurant","author":"Li","year":"2020","journal-title":"MedRxiv"},{"key":"10.1016\/j.buildenv.2021.108347_bib35","first-page":"107788","article-title":"Probable airborne transmission of SARS-CoV-2 in a poorly ventilated restaurant, Build","volume":"196","author":"Li","year":"2021","journal-title":"Environ. Times"},{"key":"10.1016\/j.buildenv.2021.108347_bib36","doi-asserted-by":"crossref","first-page":"106244","DOI":"10.1016\/j.buildenv.2019.106244","article-title":"Indoor airflow and contaminant transport in a room with coupled displacement ventilation and passive-chilled-beam systems","volume":"161","author":"Shi","year":"2019","journal-title":"Build. Environ."},{"key":"10.1016\/j.buildenv.2021.108347_bib37","series-title":"CONFLATION OF COMPUTATIONAL FLUID DYNAMICS AND BUILDING THERMAL SIMULATION","author":"Negr\u00e3o","year":"1995"},{"key":"10.1016\/j.buildenv.2021.108347_bib38","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1177\/1420326X18810568","article-title":"Challenges of using CFD simulation for the design and online control of ventilation systems","volume":"28","author":"Cao","year":"2019","journal-title":"Indoor Built Environ."},{"key":"10.1016\/j.buildenv.2021.108347_bib39","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1016\/0360-1323(92)90033-L","article-title":"Computational fluid dynamics for building air flow prediction-current status and capabilities","volume":"27","author":"Jones","year":"1992","journal-title":"Build. Environ."},{"key":"10.1016\/j.buildenv.2021.108347_bib40","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1504\/PCFD.2008.021333","article-title":"Numerical study of Indoor Air Quality and thermal comfort under stratum ventilation","volume":"8","author":"Tian","year":"2008","journal-title":"Prog. Comput. Fluid Dynam. Int. J."},{"key":"10.1016\/j.buildenv.2021.108347_bib41","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/0360-1323(89)90018-8","article-title":"Application of computational fluid dynamics in room ventilation","volume":"24","author":"Awbi","year":"1989","journal-title":"Build. Environ."},{"key":"10.1016\/j.buildenv.2021.108347_bib42","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/0378-7788(95)00931-0","article-title":"Evaluation of room air distribution systems using computational fluid dynamics","volume":"23","author":"Gan","year":"1995","journal-title":"Energy Build."},{"key":"10.1016\/j.buildenv.2021.108347_bib43","article-title":"Computational fluid dynamics and room Air movement","volume":"14","author":"Peter Vilhelm","year":"2004","journal-title":"Indoor Air"},{"key":"10.1016\/j.buildenv.2021.108347_bib44","unstructured":"G. Villi, W. Pasut, M. De Carli, Computational Aspects Of Modeling Different Strategies For Kitchen Ventilation: A Comparison Between The Multi-Zone Approach And Cfd Modelling With Reference To Predicted Indoor Pollutant Concentrations, (n.d)."},{"key":"10.1016\/j.buildenv.2021.108347_bib45","series-title":"Coupling of a Multizone Airflow Simulation Program with Computational Fluid Dynamics for Indoor Environmental Analysis","author":"Gao","year":"2002"},{"key":"10.1016\/j.buildenv.2021.108347_bib46","doi-asserted-by":"crossref","first-page":"142593","DOI":"10.1016\/j.scitotenv.2020.142593","article-title":"Multizone airflow and pollution simulations of indoor emission sources","volume":"766","author":"Jose","year":"2021","journal-title":"Sci. Total Environ."},{"key":"10.1016\/j.buildenv.2021.108347_bib47","series-title":"Studying Innovative Concepts By Coupling Simplified: Simulation And Multizone Airflow Model Studying Innovative Concepts By Coupling Simplified Simulation And Multizone Airflow Model","author":"Trocme","year":"2011"},{"key":"10.1016\/j.buildenv.2021.108347_bib48","series-title":"LBNL-49578 ASSESSING MULTIZONE AIRFLOW SIMULATION SOFTWARE ASSESSING MULTIZONE AIRFLOW SIMULATION SOFTWARE","author":"Lorenzetti","year":"2002"},{"key":"10.1016\/j.buildenv.2021.108347_bib49","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/0378-7788(92)90040-N","article-title":"A survey of airflow models for multizone structures","volume":"18","author":"Feustel","year":"1992","journal-title":"Energy Build."},{"key":"10.1016\/j.buildenv.2021.108347_bib50","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/S0378-7788(98)00043-7","article-title":"COMIS-an international multizone air-flow and contaminant transport model","volume":"30","author":"Feustel","year":"1999","journal-title":"Energy Build."},{"key":"10.1016\/j.buildenv.2021.108347_bib51","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1111\/ina.12751","article-title":"Transmission of SARS\u2010CoV\u20102 by inhalation of respiratory aerosol in the Skagit Valley Chorale superspreading event","volume":"31","author":"Miller","year":"2021","journal-title":"Indoor Air"},{"key":"10.1016\/j.buildenv.2021.108347_bib52","doi-asserted-by":"crossref","first-page":"123771","DOI":"10.1016\/j.jhazmat.2020.123771","article-title":"Multi-route transmission potential of SARS-CoV-2 in healthcare facilities","volume":"402","author":"Feng","year":"2021","journal-title":"J. Hazard Mater."},{"key":"10.1016\/j.buildenv.2021.108347_bib53","article-title":"Exposure assessment for airborne transmission of SARS-CoV-2 via breathing, speaking, coughing and sneezing","author":"Schijven","year":"2020","journal-title":"MedRxiv"},{"key":"10.1016\/j.buildenv.2021.108347_bib54","series-title":"Review of infective dose, routes of transmission, and outcome of COVID-19 caused by the SARS-COV2 virus: comparison with other respiratory viruses Running title: COVID-19 infective dose review","author":"Karimzadeh","year":"2020"},{"key":"10.1016\/j.buildenv.2021.108347_bib55","doi-asserted-by":"crossref","first-page":"107617","DOI":"10.1016\/j.buildenv.2021.107617","article-title":"Modelling uncertainty in the relative risk of exposure to the SARS-CoV-2 virus by airborne aerosol transmission in well mixed indoor air","volume":"191","author":"Jones","year":"2021","journal-title":"Build. Environ."},{"key":"10.1016\/j.buildenv.2021.108347_bib56","series-title":"Updated OpenStudio Small and Medium Office Prototype Models (Conference)","author":"Im","year":"2019"},{"key":"10.1016\/j.buildenv.2021.108347_bib57","unstructured":"Commercial Prototype Building Models | Building Energy Codes Program, (n.d.). https:\/\/www.energycodes.gov\/development\/commercial\/prototype_models (accessed May 3, 2021)."},{"key":"10.1016\/j.buildenv.2021.108347_bib58","author":"Dols"},{"key":"10.1016\/j.buildenv.2021.108347_bib59","series-title":"ERDC\/CERL TR-04-25, Analysis of Numerical Models for Dispersion of Chemical\/Biological Agents in Complex Building Environments","author":"Sohn","year":"2004"},{"key":"10.1016\/j.buildenv.2021.108347_bib60","author":"Dutton"},{"key":"10.1016\/j.buildenv.2021.108347_bib61","series-title":"AIAA Pap","article-title":"Contam 3. 2 plume flowfield analysis and contamination prediction computer program: analysis model and experimental verification","author":"Hoffman","year":"1985"},{"key":"10.1016\/j.buildenv.2021.108347_bib62","doi-asserted-by":"crossref","first-page":"1341","DOI":"10.1177\/1420326X19841119","article-title":"Weather-dependent modelling of the indoor radon concentration in two dwellings using CONTAM","volume":"28","author":"Garc\u00eda-Tobar","year":"2019","journal-title":"Indoor Built Environ."},{"key":"10.1016\/j.buildenv.2021.108347_bib63","series-title":"AIAA Pap","article-title":"Experimental investigation OF bipropellant exhaust plume flowfield, heating and contamination, and comparison with the CONTAM computer model predictions","author":"Trinks","year":"1983"},{"key":"10.1016\/j.buildenv.2021.108347_bib64","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.buildenv.2018.06.013","article-title":"Validation and assessment of the CFD-0 module of CONTAM software for airborne contaminant transport simulation in laboratory and hospital applications","volume":"142","author":"Barbosa","year":"2018","journal-title":"Build. Environ."},{"key":"10.1016\/j.buildenv.2021.108347_bib65","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1177\/0143624415619464","article-title":"Using coupled energy, airflow and IAQ software (TRNSYS\/CONTAM) to evaluate building ventilation strategies","volume":"37","author":"Dols","year":"2016","journal-title":"Build. Serv. Eng. Res. Technol. BSER T."},{"key":"10.1016\/j.buildenv.2021.108347_bib66","doi-asserted-by":"crossref","unstructured":"W.S. Dols, S.J. Emmerich, B.J. Polidoro, Coupling the multizone airflow and contaminant transport software CONTAM with EnergyPlus using co-simulation Article History, (n.d.). https:\/\/doi.org\/10.1007\/s12273-016-0279-2.","DOI":"10.1007\/s12273-016-0279-2"},{"key":"10.1016\/j.buildenv.2021.108347_bib67","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1080\/10789669.2010.10390932","article-title":"Using CFD capabilities of CONTAM 3.0 for simulating airflow and contaminant transport in and around buildings","volume":"16","author":"Wang","year":"2010","journal-title":"HVAC R Res."},{"key":"10.1016\/j.buildenv.2021.108347_bib68","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1111\/j.1600-0668.1996.00007.x","article-title":"A comprehensive validation of two airflow models - COMIS and CONTAM","volume":"6","author":"Haghighat","year":"1996","journal-title":"Indoor Air"},{"key":"10.1016\/j.buildenv.2021.108347_bib69","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.buildenv.2012.11.013","article-title":"Multizone modeling of strategies to reduce the spread of airborne infectious agents in healthcare facilities","volume":"60","author":"Emmerich","year":"2013","journal-title":"Build. Environ."},{"key":"10.1016\/j.buildenv.2021.108347_bib70","author":"Ng"},{"key":"10.1016\/j.buildenv.2021.108347_bib71","article-title":"Comparing the respirable aerosol concentrations and particle size distributions generated by singing","author":"Gregson","year":"2020","journal-title":"Speaking and Breathing"},{"key":"10.1016\/j.buildenv.2021.108347_bib72","series-title":"COVID-19 Risks and Precautions for Choirs","year":"2020"},{"key":"10.1016\/j.buildenv.2021.108347_bib73","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0246819","article-title":"Aerosol emission of adolescents voices during speaking, singing and shouting","volume":"16","author":"M\u00fcrbe","year":"2021","journal-title":"PloS One"},{"key":"10.1016\/j.buildenv.2021.108347_bib74","doi-asserted-by":"crossref","DOI":"10.7554\/eLife.57309","article-title":"Sars-cov-2 (Covid-19) by the numbers","volume":"9","author":"Bar-On","year":"2020","journal-title":"Elife"},{"key":"10.1016\/j.buildenv.2021.108347_bib75","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1056\/NEJMoa2001017","article-title":"A novel coronavirus from patients with pneumonia in China, 2019","volume":"382","author":"Zhu","year":"2020","journal-title":"N. Engl. J. Med."},{"key":"10.1016\/j.buildenv.2021.108347_bib76","doi-asserted-by":"crossref","first-page":"9188","DOI":"10.1021\/acsnano.0c05025","article-title":"Filtration efficiencies of nanoscale Aerosol by cloth mask materials used to slow the spread of SARS-CoV-2","volume":"14","author":"Zangmeister","year":"2020","journal-title":"ACS Nano"},{"key":"10.1016\/j.buildenv.2021.108347_bib77","series-title":"Final Report on Evaluation of In-Room Particulate Matter Air Filtration Devices (EPA\/600\/R-08\/012)","author":"Kogan","year":"2008"},{"key":"10.1016\/j.buildenv.2021.108347_bib78","doi-asserted-by":"crossref","first-page":"1362","DOI":"10.1016\/j.buildenv.2008.05.015","article-title":"Estimating the effects of ambient conditions on the performance of UVGI air cleaners","volume":"44","author":"Lau","year":"2009","journal-title":"Build. Environ."},{"key":"10.1016\/j.buildenv.2021.108347_bib79","series-title":"Lamp and In-Duct Device Modeling for UVGI System Performance Prediction","author":"Lau","year":"2009"},{"key":"10.1016\/j.buildenv.2021.108347_bib80","author":"Kowalski"},{"key":"10.1016\/j.buildenv.2021.108347_bib82","unstructured":"Weather Data | EnergyPlus, (n.d.). https:\/\/energyplus.net\/weather (accessed May 3, 2021)."},{"key":"10.1016\/j.buildenv.2021.108347_bib83","first-page":"282","article-title":"Quantifying chemical\/biological event severity with vulnerability-based performance metrics","volume":"117","author":"DeGraw","year":"2011","journal-title":"ASHRAE Trans"},{"key":"10.1016\/j.buildenv.2021.108347_bib84","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1016\/0304-3894(86)85003-8","article-title":"Concentration-time mortality response relationship of irritant and systemically acting vapours and gases","volume":"13","author":"ten Berge","year":"1986","journal-title":"J. Hazard Mater."},{"key":"10.1016\/j.buildenv.2021.108347_bib85","series-title":"The Standards for Ventilation and Indoor Air Quality - ANSI\/ASHRAE Standard 62.1 Ventilation for Acceptable Indoor Air Quality & ANSI\/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality in Residential Buildings","year":"2019"},{"key":"10.1016\/j.buildenv.2021.108347_bib86","unstructured":"CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE, 2018 International Building Code (IBC) | ICC Digital Codes, (n.d.). https:\/\/codes.iccsafe.org\/content\/IBC2018\/chapter-4-special-detailed-requirements-based-on-occupancy-and-use (accessed June 9, 2021)."},{"key":"10.1016\/j.buildenv.2021.108347_bib87","unstructured":"NFPA 101\u00ae: Life Safety Code\u00ae, (n.d.). https:\/\/www.nfpa.org\/codes-and-standards\/all-codes-and-standards\/list-of-codes-and-standards\/detail?code=101 (accessed June 9, 2021)."},{"key":"10.1016\/j.buildenv.2021.108347_bib88","unstructured":"A. Bhatia, Stairwell Pressurization Systems Credit: 5 PDH, n.d. https:\/\/www.cedengineering.com\/userfiles\/Stairwell Pressurization Systems.pdf (accessed June 9, 2021)."}],"container-title":["Building and Environment"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0360132321007447?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0360132321007447?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,6]],"date-time":"2025-10-06T08:53:09Z","timestamp":1759740789000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0360132321007447"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12]]},"references-count":87,"alternative-id":["S0360132321007447"],"URL":"https:\/\/doi.org\/10.1016\/j.buildenv.2021.108347","relation":{},"ISSN":["0360-1323"],"issn-type":[{"value":"0360-1323","type":"print"}],"subject":[],"published":{"date-parts":[[2021,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Multizonal modeling of SARS-CoV-2 aerosol dispersion in a virtual office building","name":"articletitle","label":"Article Title"},{"value":"Building and Environment","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.buildenv.2021.108347","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"108347"}}