{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T16:55:22Z","timestamp":1786985722252,"version":"build-2736575974"},"reference-count":16,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2019,5,1]],"date-time":"2019-05-01T00:00:00Z","timestamp":1556668800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,5,1]],"date-time":"2019-05-01T00:00:00Z","timestamp":1556668800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Cardiovascular Revascularization Medicine"],"published-print":{"date-parts":[[2019,5]]},"DOI":"10.1016\/j.carrev.2019.02.016","type":"journal-article","created":{"date-parts":[[2019,2,18]],"date-time":"2019-02-18T02:12:35Z","timestamp":1550455955000},"page":"409-412","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":33,"title":["Adverse Events Associated with the Use of Guide Extension Catheters during Percutaneous Coronary Intervention: Reports from the Manufacturer and User Facility Device Experience (MAUDE) database"],"prefix":"10.1016","volume":"20","author":[{"given":"Yuefeng","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arhum A.","family":"Shah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Evan","family":"Shlofmitz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nauman","family":"Khalid","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anees","family":"Musallam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaffar M.","family":"Khan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Micaela","family":"Iantorno","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deepakraj","family":"Gajanana","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toby","family":"Rogers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hayder","family":"Hashim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nelson L.","family":"Bernardo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ron","family":"Waksman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.carrev.2019.02.016_bb0005","first-page":"208","article-title":"The GuideLiner catheter: a useful tool in the armamentarium of the interventional cardiologist","volume":"10","author":"Boukhris","year":"2015","journal-title":"J Tehran Heart Cent"},{"key":"10.1016\/j.carrev.2019.02.016_bb0010","first-page":"468","article-title":"The efficacy and safety of using extension catheters in complex coronary interventions: a single center experience","volume":"33","author":"Huang","year":"2017","journal-title":"Acta Cardiol Sin"},{"key":"10.1016\/j.carrev.2019.02.016_bb0015","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1016\/j.ihj.2015.04.018","article-title":"A unique complication of the GuideZilla guide extension support catheter and the risk of stent stripping in interventional & endovascular interventions","volume":"67","author":"Waggoner","year":"2015","journal-title":"Indian Heart J"},{"key":"10.1016\/j.carrev.2019.02.016_bb0020","doi-asserted-by":"crossref","first-page":"336","DOI":"10.4244\/EIJV8I3A52","article-title":"Usefulness and safety of the GuideLiner catheter to enhance intubation and support of guide catheters: insights from the Twente GuideLiner registry","volume":"8","author":"de Man","year":"2012","journal-title":"EuroIntervention"},{"key":"10.1016\/j.carrev.2019.02.016_bb0025","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1159\/000369620","article-title":"Usefulness and safety of a guide catheter extension system for the percutaneous treatment of complex coronary lesions by a transradial approach","volume":"24","author":"Garcia-Blas","year":"2015","journal-title":"Med Princ Pract"},{"key":"10.1016\/j.carrev.2019.02.016_bb0030","first-page":"1057","article-title":"Experience and complications associated with use of guide extension catheters in percutaneous coronary intervention","volume":"88","author":"Waterbury","year":"2016","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.carrev.2019.02.016_bb0035","doi-asserted-by":"crossref","DOI":"10.1097\/MD.0000000000008172","article-title":"The safety and feasibility of GuideZilla catheter in complex coronary interventions and an observational study","volume":"96","author":"Ma","year":"2017","journal-title":"Medicine (Baltimore)"},{"key":"10.1016\/j.carrev.2019.02.016_bb0040","first-page":"171","article-title":"Guidezilla extension catheter for percutaneous interventional therapy of complex lesions via a transradial approach: case series from a single-center experience","volume":"25","author":"Chen","year":"2018","journal-title":"Cardiol J"},{"key":"10.1016\/j.carrev.2019.02.016_bb0045","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1097\/GRF.0b013e318161e657","article-title":"Introduction to the MAUDE database","volume":"51","author":"Gurtcheff","year":"2008","journal-title":"Clin Obstet Gynecol"},{"key":"10.1016\/j.carrev.2019.02.016_bb0050","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1016\/j.carrev.2016.06.002","article-title":"Review: stent fracture in the drug-eluting stent era","volume":"17","author":"Omar","year":"2016","journal-title":"Cardiovasc Revasc Med"},{"key":"10.1016\/j.carrev.2019.02.016_bb0055","first-page":"E211","article-title":"Frequency, indications, and outcomes of guide catheter extension use in percutaneous coronary intervention","volume":"27","author":"Duong","year":"2015","journal-title":"J Invasive Cardiol"},{"key":"10.1016\/j.carrev.2019.02.016_bb0060","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1111\/joic.12354","article-title":"Efficacy and safety of the GuideLiner mother-in-child guide catheter extension in percutaneous coronary intervention","volume":"30","author":"Sharma","year":"2017","journal-title":"J Interv Cardiol"},{"key":"10.1016\/j.carrev.2019.02.016_bb0065","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.jsha.2017.09.001","article-title":"The GuideLiner catheter: a supportive tool in percutaneous coronary intervention of chronic total occlusion","volume":"30","author":"Guelker","year":"2018","journal-title":"J Saudi Heart Assoc"},{"key":"10.1016\/j.carrev.2019.02.016_bb0070","doi-asserted-by":"crossref","DOI":"10.1136\/openhrt-2015-000331","volume":"3","author":"Alkhalil","year":"2016","journal-title":"Open Heart"},{"key":"10.1016\/j.carrev.2019.02.016_bb0075","doi-asserted-by":"crossref","first-page":"5444","DOI":"10.1038\/s41598-018-23633-7","article-title":"Early clinical experience with Guidezilla for transradial interventions in China","volume":"8","author":"Ma","year":"2018","journal-title":"Sci Rep"},{"key":"10.1016\/j.carrev.2019.02.016_bb0080","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1007\/s12928-017-0500-y","article-title":"Spontaneous rotation of the monorail-type guide extension support catheter during advancement of a curved guiding catheter: the potential hazard of twisting with the coronary guidewire","volume":"33","author":"Hashimoto","year":"2018","journal-title":"Cardiovasc Interv Ther"}],"container-title":["Cardiovascular Revascularization Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1553838919301496?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1553838919301496?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T10:14:54Z","timestamp":1761560094000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1553838919301496"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5]]},"references-count":16,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2019,5]]}},"alternative-id":["S1553838919301496"],"URL":"https:\/\/doi.org\/10.1016\/j.carrev.2019.02.016","relation":{},"ISSN":["1553-8389"],"issn-type":[{"value":"1553-8389","type":"print"}],"subject":[],"published":{"date-parts":[[2019,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Adverse Events Associated with the Use of Guide Extension Catheters during Percutaneous Coronary Intervention: Reports from the Manufacturer and User Facility Device Experience (MAUDE) database","name":"articletitle","label":"Article Title"},{"value":"Cardiovascular Revascularization Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.carrev.2019.02.016","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}