{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T19:16:28Z","timestamp":1780341388071,"version":"3.54.1"},"reference-count":23,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,3,1]],"date-time":"2025-03-01T00:00:00Z","timestamp":1740787200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,3,1]],"date-time":"2025-03-01T00:00:00Z","timestamp":1740787200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,6,19]],"date-time":"2024-06-19T00:00:00Z","timestamp":1718755200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Cardiovascular Revascularization Medicine"],"published-print":{"date-parts":[[2025,3]]},"DOI":"10.1016\/j.carrev.2024.06.011","type":"journal-article","created":{"date-parts":[[2024,6,19]],"date-time":"2024-06-19T07:13:59Z","timestamp":1718781239000},"page":"23-30","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"special_numbering":"C","title":["Haemodynamic and clinical outcomes at 5\u00a0years according to predicted prosthesis-patient mismatch after transcatheter aortic valve replacement"],"prefix":"10.1016","volume":"72","author":[{"given":"Yoichi","family":"Sugiyama","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hirokazu","family":"Miyashita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomoki","family":"Ochiai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koki","family":"Shishido","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mikko","family":"Jalanko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Futoshi","family":"Yamanaka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tommi","family":"V\u00e4h\u00e4silta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigeru","family":"Saito","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mika","family":"Laine","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Noriaki","family":"Moriyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.carrev.2024.06.011_bb0005","doi-asserted-by":"crossref","first-page":"1131","DOI":"10.1016\/S0735-1097(00)00859-7","article-title":"Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention","volume":"36","author":"Pibarot","year":"2000","journal-title":"J Am Coll Cardiol"},{"issue":"1014\u201322","key":"10.1016\/j.carrev.2024.06.011_bb0010","article-title":"Prosthesis-patient mismatch in high-risk patients with severe aortic stenosis: a randomized trial of a self-expanding prosthesis","volume":"151","author":"Zorn","year":"2016","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.carrev.2024.06.011_bb0015","doi-asserted-by":"crossref","first-page":"2701","DOI":"10.1016\/j.jacc.2018.09.001","article-title":"Prosthesis-patient mismatch in patients undergoing Transcatheter aortic valve replacement: from the STS\/ACC TVT registry","volume":"72","author":"Herrmann","year":"2018","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.carrev.2024.06.011_bb0020","doi-asserted-by":"crossref","first-page":"1323","DOI":"10.1016\/j.jacc.2014.06.1195","article-title":"Incidence and sequelae of prosthesis-patient mismatch in transcatheter versus surgical valve replacement in high-risk patients with severe aortic stenosis: a PARTNER trial cohort--a analysis","volume":"64","author":"Pibarot","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.carrev.2024.06.011_bb0025","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/j.jcmg.2018.10.020","article-title":"Imaging for predicting and assessing prosthesis-patient mismatch after aortic valve replacement","volume":"12","author":"Pibarot","year":"2019","journal-title":"JACC Cardiovasc Imaging"},{"key":"10.1016\/j.carrev.2024.06.011_bb0030","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.jacc.2005.05.100","article-title":"Flow-dependent changes in Doppler-derived aortic valve effective orifice area are real and not due to artifact","volume":"47","author":"Kadem","year":"2006","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.carrev.2024.06.011_bb0035","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1093\/ehjci\/jeaa235","article-title":"Reclassification of prosthesis-patient mismatch after transcatheter aortic valve replacement using predicted vs. measured indexed effective orifice area","volume":"22","author":"Ternacle","year":"2021","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"10.1016\/j.carrev.2024.06.011_bb0040","doi-asserted-by":"crossref","first-page":"1466","DOI":"10.1016\/j.jcin.2021.03.069","article-title":"Prosthesis-patient mismatch after aortic valve replacement in the PARTNER 2 trial and registry","volume":"14","author":"Ternacle","year":"2021","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.carrev.2024.06.011_bb0045","doi-asserted-by":"crossref","first-page":"746","DOI":"10.4244\/EIJ-D-23-00456","article-title":"Long-term outcomes of measured and predicted prosthesis-patient mismatch following transcatheter aortic valve replacement","volume":"19","author":"Tomii","year":"2023","journal-title":"EuroIntervention"},{"key":"10.1016\/j.carrev.2024.06.011_bb0050","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.jcmg.2018.04.010","article-title":"Comprehensive echocardiographic assessment of Normal Transcatheter valve function","volume":"12","author":"Hahn","year":"2019","journal-title":"JACC Cardiovasc Imaging"},{"key":"10.1016\/j.carrev.2024.06.011_bb0055","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1093\/ehjci\/jew025","volume":"17","author":"Lancellotti","year":"2016","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"10.1016\/j.carrev.2024.06.011_bb0060","doi-asserted-by":"crossref","first-page":"S45","DOI":"10.1093\/ejcts\/ezs533","article-title":"Valve academic research consortium (VARC)-2. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the valve academic research Consortium-2 consensus document (VARC-2)","volume":"42","author":"Kappetein","year":"2012","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.carrev.2024.06.011_bb0065","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/j.amjcard.2022.04.037","article-title":"Device failure in bicuspid aortic stenosis following Transcatheter aortic valve implantation","volume":"176","author":"Moriyama","year":"2022","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.carrev.2024.06.011_bb0070","doi-asserted-by":"crossref","first-page":"3599","DOI":"10.1093\/eurheartj\/ehab368","article-title":"ESC Scientific Document Group. 2021 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure","volume":"42","author":"McDonagh","year":"2021","journal-title":"Eur Heart J"},{"key":"10.1016\/j.carrev.2024.06.011_bb0075","first-page":"e895","article-title":"2022 AHA\/ACC\/HFSA guideline for the Management of Heart Failure: a report of the American College of Cardiology\/American Heart Association joint committee on clinical practice guidelines","volume":"145","author":"Heidenreich","year":"2022","journal-title":"Circulation"},{"key":"10.1016\/j.carrev.2024.06.011_bb0080","doi-asserted-by":"crossref","first-page":"1518","DOI":"10.1093\/eurheartj\/ehs003","article-title":"The impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years","volume":"33","author":"Head","year":"2012","journal-title":"Eur Heart J"},{"key":"10.1016\/j.carrev.2024.06.011_bb0085","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.athoracsur.2018.01.090","article-title":"The incidence and consequence of prosthesis-patient mismatch after surgical aortic valve replacement","volume":"106","author":"Fallon","year":"2018","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.carrev.2024.06.011_bb0090","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1016\/j.jcin.2018.01.273","article-title":"OCEAN-TAVI investigators. Incidence, predictors, and clinical impact of prosthesis-patient mismatch following Transcatheter aortic valve replacement in Asian patients: the OCEAN-TAVI registry","volume":"11","author":"Miyasaka","year":"2018","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.carrev.2024.06.011_bb0095","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/j.amjcard.2010.02.036","article-title":"Prosthesis-patient mismatch after transcatheter aortic valve implantation with the medtronic CoreValve system in patients with aortic stenosis","volume":"106","author":"Tzikas","year":"2010","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.carrev.2024.06.011_bb0100","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.jcmg.2022.10.013","article-title":"Prosthesis-patient mismatch after TAVR: the new flow of information","volume":"16","author":"Sengupta","year":"2023","journal-title":"JACC Cardiovasc Imaging"},{"key":"10.1016\/j.carrev.2024.06.011_bb0105","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jcmg.2022.05.010","article-title":"Clinical and echocardiographic characteristics of flow-based classification following balloon-expandable Transcatheter heart valve in PARTNER trials","volume":"16","author":"Akinmolayemi","year":"2023","journal-title":"JACC Cardiovasc Imaging"},{"key":"10.1016\/j.carrev.2024.06.011_bb0110","doi-asserted-by":"crossref","first-page":"1910","DOI":"10.1016\/j.jacc.2011.08.027","article-title":"Hemodynamic and clinical impact of prosthesis-patient mismatch after transcatheter aortic valve implantation","volume":"58","author":"Ewe","year":"2011","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.carrev.2024.06.011_bb0115","doi-asserted-by":"crossref","first-page":"2446","DOI":"10.1016\/j.jacc.2020.03.042","article-title":"Regression of left ventricular mass after transcatheter aortic valve replacement: the PARTNER trials and registries","volume":"75","author":"Chau","year":"2020","journal-title":"J Am Coll Cardiol"}],"container-title":["Cardiovascular Revascularization Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1553838924005414?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1553838924005414?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,3,18]],"date-time":"2025-03-18T07:40:49Z","timestamp":1742283649000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1553838924005414"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3]]},"references-count":23,"alternative-id":["S1553838924005414"],"URL":"https:\/\/doi.org\/10.1016\/j.carrev.2024.06.011","relation":{},"ISSN":["1553-8389"],"issn-type":[{"value":"1553-8389","type":"print"}],"subject":[],"published":{"date-parts":[[2025,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Haemodynamic and clinical outcomes at 5\u00a0years according to predicted prosthesis-patient mismatch after transcatheter aortic valve replacement","name":"articletitle","label":"Article Title"},{"value":"Cardiovascular Revascularization Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.carrev.2024.06.011","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Author(s). Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}