{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T08:12:53Z","timestamp":1788423173298,"version":"build-2803163510"},"reference-count":33,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2014,3,1]],"date-time":"2014-03-01T00:00:00Z","timestamp":1393632000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clinica Chimica Acta"],"published-print":{"date-parts":[[2014,3]]},"DOI":"10.1016\/j.cca.2013.12.014","type":"journal-article","created":{"date-parts":[[2013,12,18]],"date-time":"2013-12-18T11:48:00Z","timestamp":1387367280000},"page":"1-8","source":"Crossref","is-referenced-by-count":29,"special_numbering":"C","title":["Influence of analytical bias and imprecision on the number of false positive results using Guideline-Driven Medical Decision Limits"],"prefix":"10.1016","volume":"430","author":[{"given":"Per","family":"Hyltoft Petersen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George G.","family":"Klee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.cca.2013.12.014_bb0005","series-title":"Strategies to set global analytical quality specifications in laboratory medicine","first-page":"475","volume":"59","year":"1999"},{"key":"10.1016\/j.cca.2013.12.014_bb0010","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1080\/00365519950185409","volume":"59","author":"Kenny","year":"1999","journal-title":"Scand J Clin Lab Invest"},{"key":"10.1016\/j.cca.2013.12.014_bb0015","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1007\/s00769-009-0630-8","article-title":"Strategies to set global analytical quality specifications in laboratory medicine: 10years on from the Stockholm consensus conference","volume":"15","author":"Hyltoft Petersen","year":"2010","journal-title":"Accred Qual Assur"},{"key":"10.1016\/j.cca.2013.12.014_bb0020","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1373\/clinchem.2009.133660","article-title":"Establishment of outcome-related analytical performance goals","volume":"56","author":"Klee","year":"2010","journal-title":"Clin Chem"},{"key":"10.1016\/j.cca.2013.12.014_bb0025","unstructured":"Gallaher PM, Mobley RL, Klee GG, Schryver P, preparers. The impact of calibration error in medical decision making. Final report. [Gaithersburg, MD]: National Institute of Standards and Technology, Chemical Science and Technology Laboratory; 2004. Report nr: Planning report04-1. Available at: www.nist.gov\/director\/prog-ofc\/report04\u20131.pdf."},{"key":"10.1016\/j.cca.2013.12.014_bb0030","series-title":"JCGM 200","article-title":"International vocabulary of metrology\u2014basic and general concepts and associated terms (VIM)","author":"BIPM","year":"2012"},{"key":"10.1016\/j.cca.2013.12.014_bb0035","first-page":"589","article-title":"Models for combining random and systematic errors. Assumptions and consequences for different models","volume":"39","author":"Hyltoft Petersen","year":"2001","journal-title":"Clin Chem Lab Med"},{"key":"10.1016\/j.cca.2013.12.014_bb0040","first-page":"416","article-title":"Proposed goals for analytical precision and accuracy in single-point diagnostic testing","volume":"112","author":"Harris","year":"1988","journal-title":"Arch Pathol Lab Med"},{"key":"10.1016\/j.cca.2013.12.014_bb0045","series-title":"JCGM 100","article-title":"Evaluation of measurement data\u2014guide to the expression of uncertainty in measurement GUM","author":"BIPM","year":"2008"},{"key":"10.1016\/j.cca.2013.12.014_bb0050","series-title":"Cost-effective quality control: managing the quality and productivity of analytical processes","author":"Westgard","year":"1986"},{"key":"10.1016\/j.cca.2013.12.014_bb0055","doi-asserted-by":"crossref","first-page":"1334","DOI":"10.1373\/clinchem.2011.165308","article-title":"Gross overestimation of total allowable error based on biological variation","volume":"57","author":"Oosterhuis","year":"2011","journal-title":"Clin Chem"},{"key":"10.1016\/j.cca.2013.12.014_bb0060","doi-asserted-by":"crossref","first-page":"757","DOI":"10.3109\/00365518809088757","article-title":"Analytical goals for the acceptance of common reference intervals for laboratories throughout a geographical area","volume":"48","author":"Gowans","year":"1988","journal-title":"Scand J Clin Lab Invest"},{"key":"10.1016\/j.cca.2013.12.014_bb0065","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1177\/000456320203900601","article-title":"Combination of analytical quality specifications based on biological within- and between-subject variation","volume":"39","author":"Hyltoft Petersen","year":"2002","journal-title":"Ann Clin Biochem"},{"issue":"Suppl. (i)","key":"10.1016\/j.cca.2013.12.014_bb0070","first-page":"S53","article-title":"Basics of estimating measurement uncertainty","volume":"29","author":"White","year":"2008","journal-title":"Clin Biochem Rev"},{"key":"10.1016\/j.cca.2013.12.014_bb0075","doi-asserted-by":"crossref","first-page":"c61","DOI":"10.2337\/dc11-9998","article-title":"Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus","volume":"34","author":"Sacks","year":"2011","journal-title":"Diabetes Care"},{"key":"10.1016\/j.cca.2013.12.014_bb0080","doi-asserted-by":"crossref","first-page":"515","DOI":"10.7326\/0003-4819-124-5-199603010-00012","article-title":"American College of Physicians guidelines for using serum cholesterol, high-density lipoprotein cholesterol, and triglyceride levels as screening tests for preventing coronary heart disease in adults","volume":"124","author":"Garber","year":"1996","journal-title":"Ann Intern Med"},{"key":"10.1016\/j.cca.2013.12.014_bb0085","first-page":"819","article-title":"Analytical performance, reference values and decision limits. A need to differentiate between reference intervals and decision limits and to define analytical quality specifications","volume":"50","author":"Hyltoft Petersen","year":"2012","journal-title":"Clin Chem Lab Med"},{"key":"10.1016\/j.cca.2013.12.014_bb0090","first-page":"374","article-title":"Statistical principles underlying analytical goal-setting in clinical chemistry","volume":"72","author":"Harris","year":"1979","journal-title":"Am J Clin Pathol"},{"key":"10.1016\/j.cca.2013.12.014_bb0095","first-page":"639","article-title":"Approved recommendation (1987) on the theory of reference values. Part 2. Selection of individuals for the production of reference values","volume":"25","author":"PetitClerc","year":"1987","journal-title":"J Clin Chem Clin Biochem"},{"key":"10.1016\/j.cca.2013.12.014_bb0100","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1080\/003655101300133621","article-title":"Plasma glucose reference interval in a low-risk population 2. Impact of the new WHO and ADA recommendations on diagnosis of diabetes mellitus","volume":"61","author":"J\u00f8rgensen","year":"2001","journal-title":"Scand J Clin Lab Invest"},{"key":"10.1016\/j.cca.2013.12.014_bb0105","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1080\/003655101300133630","article-title":"Evaluation of systematic and random factors in measurements of fasting plasma glucose as the basis for analytical quality specifications in the diagnosis of diabetes. 3. Impact of the new WHO and ADA recommendations on diagnosis of diabetes mellitus","volume":"61","author":"Hyltoft Petersen","year":"2001","journal-title":"Scand J Clin Lab Invest"},{"issue":"Suppl. 240","key":"10.1016\/j.cca.2013.12.014_bb0110","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1080\/00365510500236135","article-title":"Consequences of bias and imprecision in measurements of glucose and HbA1c for the diagnosis and prognosis of diabetes mellitus","volume":"65","author":"Hyltoft Petersen","year":"2005","journal-title":"Scand J Clin Lab Invest"},{"key":"10.1016\/j.cca.2013.12.014_bb0115","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1177\/193229680900300306","article-title":"A review of the challenges in measuring haemoglobin A1c","volume":"3","author":"Weykamp","year":"2009","journal-title":"J Diabetes Sci Technol"},{"key":"10.1016\/j.cca.2013.12.014_bb0120","doi-asserted-by":"crossref","first-page":"1271","DOI":"10.1089\/dia.2011.0106","volume":"13","author":"Nordin","year":"2011","journal-title":"Diabetes Tecnol Ther"},{"key":"10.1016\/j.cca.2013.12.014_bb0125","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1080\/003655102764654349","article-title":"Upper reference limit, analytical quality specifications and clinical use of haemoglobin A1C","volume":"62","author":"J\u00f8rgensen","year":"2002","journal-title":"Scand J Clin Lab Invest"},{"key":"10.1016\/j.cca.2013.12.014_bb0130","doi-asserted-by":"crossref","first-page":"1501","DOI":"10.1515\/CCLM.2011.233","article-title":"Within-subject biological variation of glucose and HbA1c in healthy persons and in type 1 diabetes patients","volume":"49","author":"Carlsen","year":"2011","journal-title":"Clin Chem Lab Med"},{"issue":"8","key":"10.1016\/j.cca.2013.12.014_bb0135","doi-asserted-by":"crossref","first-page":"1602","DOI":"10.1373\/clinchem.2006.069369","article-title":"Reference change values for brain natriuretic peptides revisited","volume":"52","author":"Fokkema","year":"2006","journal-title":"Clin Chem"},{"key":"10.1016\/j.cca.2013.12.014_bb0140","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1504\/IJRAM.2005.007177","article-title":"The impact of variability in the risk of disease exemplified by diagnosing diabetes mellitus based on ADA and WHO criteria as gold standard","volume":"5","author":"J\u00f8rgensen","year":"2005","journal-title":"Int J Risk Assess Manag"},{"key":"10.1016\/j.cca.2013.12.014_bb0145","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1080\/00365519950185229","article-title":"Current databases on biological variation: pros, cons and progress","volume":"59","author":"Ric\u00f3s","year":"1999","journal-title":"Scand J Clin Lab Invest"},{"key":"10.1016\/j.cca.2013.12.014_bb0150","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1016\/S0140-6736(95)91748-9","article-title":"Comparing methods of measurements: why plotting difference against standard method is misleading","volume":"346","author":"Bland","year":"1995","journal-title":"Lancet"},{"key":"10.1016\/j.cca.2013.12.014_bb0155","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1093\/clinchem\/46.4.551","article-title":"Seasonal and biological variation of blood concentrations of total cholesterol, dehydroepiandrosterone sulphate, Haemoglobin A1c, IgA, prolactin and free testosterone in healthy women","volume":"46","author":"Garde","year":"2000","journal-title":"Clin Chem"},{"key":"10.1016\/j.cca.2013.12.014_bb0160","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1373\/clinchem.2008.114694","article-title":"Cutpoints in clinical chemistry: time for fundamental reassessment","volume":"55","author":"Vickers","year":"2009","journal-title":"Clin Chem"},{"key":"10.1016\/j.cca.2013.12.014_bb0165","doi-asserted-by":"crossref","first-page":"1005","DOI":"10.1007\/s00432-013-1411-7","article-title":"Serum HER-2: sensitivity, specificity, and predictive values for detecting metastatic recurrence in breast cancer patients","volume":"139","author":"S\u00f8rensen","year":"2013","journal-title":"J Cancer Res Clin Oncol"}],"container-title":["Clinica Chimica Acta"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0009898113005093?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0009898113005093?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2020,8,12]],"date-time":"2020-08-12T11:20:08Z","timestamp":1597231208000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0009898113005093"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,3]]},"references-count":33,"alternative-id":["S0009898113005093"],"URL":"https:\/\/doi.org\/10.1016\/j.cca.2013.12.014","relation":{},"ISSN":["0009-8981"],"issn-type":[{"value":"0009-8981","type":"print"}],"subject":[],"published":{"date-parts":[[2014,3]]}}}