{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T21:58:06Z","timestamp":1790114286312,"version":"4.0.1"},"reference-count":24,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,8,1]],"date-time":"2024-08-01T00:00:00Z","timestamp":1722470400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,8,1]],"date-time":"2024-08-01T00:00:00Z","timestamp":1722470400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,7,16]],"date-time":"2024-07-16T00:00:00Z","timestamp":1721088000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinica Chimica Acta"],"published-print":{"date-parts":[[2024,8]]},"DOI":"10.1016\/j.cca.2024.119877","type":"journal-article","created":{"date-parts":[[2024,7,16]],"date-time":"2024-07-16T23:45:47Z","timestamp":1721173547000},"page":"119877","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":9,"special_numbering":"C","title":["A novel approach to therapeutic drug monitoring of Ciclosporin in pediatric renal transplant recipients using volumetric absorptive microsampling (VAMS) \u2013 Teaching old dog new tricks"],"prefix":"10.1016","volume":"562","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4833-8532","authenticated-orcid":false,"given":"Arkadiusz","family":"Kocur","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bart\u0142omiej","family":"Kot","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mateusz","family":"Moczulski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Agnieszka","family":"Czajkowska","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacek","family":"Rubik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maciej","family":"Sierakowski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomasz","family":"Pawi\u0144ski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.cca.2024.119877_b0005","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1097\/FTD.0b013e3181c0eecb","article-title":"Pharmacodynamic monitoring of calcineurin inhibition therapy: principles, performance, and perspectives","volume":"32","author":"van Rossum","year":"2010","journal-title":"Ther. Drug Monit."},{"issue":"2 Suppl","key":"10.1016\/j.cca.2024.119877_b0010","doi-asserted-by":"crossref","first-page":"430S","DOI":"10.1016\/j.transproceed.2004.01.025","article-title":"Therapeutic drug monitoring of cyclosporine","volume":"36","author":"Midtvedt","year":"2004","journal-title":"Transpl. Proc."},{"issue":"2","key":"10.1016\/j.cca.2024.119877_b0015","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1097\/FTD.0000000000000269","volume":"38","author":"Seger","year":"2016","journal-title":"Ther. Drug Monit."},{"issue":"1046","key":"10.1016\/j.cca.2024.119877_b0020","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.aca.2018.09.004","article-title":"Tutorial: volumetric absorptive microsampling (VAMS)","volume":"10","author":"Protti","year":"2019","journal-title":"Anal. Chim. Acta."},{"issue":"182","key":"10.1016\/j.cca.2024.119877_b0025","article-title":"Opportunities and obstacles for microsampling techniques in bioanalysis: special focus on DBS and VAMS","volume":"15","author":"Londhe","year":"2020","journal-title":"J. Pharm. Biomed. Anal."},{"issue":"1","key":"10.1016\/j.cca.2024.119877_b0030","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1097\/FTD.0000000000001019","article-title":"Results from a proficiency testing pilot for immunosuppressant microsampling assays","volume":"45","author":"Veenhof","year":"2023","journal-title":"Ther. Drug Monit."},{"issue":"2","key":"10.1016\/j.cca.2024.119877_b0035","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1373\/jalm.2018.028126","article-title":"Feasibility of immunosuppressant drug monitoring by a microsampling device","volume":"4","author":"Gruzdys","year":"2019","journal-title":"J. Appl. Lab. Med."},{"issue":"1","key":"10.1016\/j.cca.2024.119877_b0040","doi-asserted-by":"crossref","first-page":"681","DOI":"10.3390\/ijms24010681","article-title":"Volumetric absorptive microsampling in therapeutic drug monitoring of immunosuppressive drugs-from sampling and analytical issues to clinical application","volume":"24","author":"Kocur","year":"2022","journal-title":"Int. J. Mol. Sci."},{"issue":"4","key":"10.1016\/j.cca.2024.119877_b0045","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1097\/FTD.0000000000000643","article-title":"Official international association for therapeutic drug monitoring and clinical toxicology guideline: development and validation of dried blood spot-based methods for therapeutic drug monitoring","volume":"41","author":"Capiau","year":"2019","journal-title":"Ther. Drug Monit."},{"key":"10.1016\/j.cca.2024.119877_b0050","unstructured":"European Medicines Agency information page. EMA. ICH M10 on bioanalytical method validation\u2014scientific guideline 2019. https:\/\/www.ema.europa.eu\/en\/ich-m10-bioanalytical-method-validation-scientific-guideline (Accessed 22 May 2024)."},{"issue":"165","key":"10.1016\/j.cca.2024.119877_b0055","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1016\/j.jpba.2018.12.030","article-title":"Bioanalytical method validation: new FDA guidance vs. EMA guideline. Better or worse?","volume":"20","author":"Kaza","year":"2019","journal-title":"J. Pharm. Biomed. Anal."},{"issue":"1","key":"10.1016\/j.cca.2024.119877_b0060","doi-asserted-by":"crossref","first-page":"49","DOI":"10.11613\/BM.2011.010","article-title":"Comparison of methods: passing and Bablok regression","volume":"21","author":"Bili\u0107-Zulle","year":"2011","journal-title":"Biochem. Med. (Zagreb)."},{"issue":"2","key":"10.1016\/j.cca.2024.119877_b0065","doi-asserted-by":"crossref","first-page":"141","DOI":"10.11613\/BM.2015.015","article-title":"Understanding Bland Altman analysis","volume":"25","author":"Giavarina","year":"2015","journal-title":"Biochem. Med. (Zagreb)."},{"issue":"4","key":"10.1016\/j.cca.2024.119877_b0070","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1016\/j.clinbiochem.2004.11.007","article-title":"Matrix effects: the Achilles heel of quantitative high-performance liquid chromatography\u2013electrospray\u2013tandem mass spectrometry","volume":"38","author":"Taylor","year":"2005","journal-title":"Clin. Biochem."},{"issue":"23","key":"10.1016\/j.cca.2024.119877_b0075","doi-asserted-by":"crossref","first-page":"1839","DOI":"10.4155\/bio-2017-0214","article-title":"Matrix effects and application of matrix effect factor","volume":"9","author":"Zhou","year":"2017","journal-title":"Bioanalysis."},{"key":"10.1016\/j.cca.2024.119877_b0080","unstructured":"Siemens Healthcare Diagnostics. Dimension Clinical Chemistry Systems - Ciclosporine Assay Manual. https:\/\/www.siemens-healthineers.com\/en-us\/clinical-specialities\/organ-transplant\/cyclosporine-assays\/csa-csae-assays (Accessed 22 May 2024)."},{"issue":"3","key":"10.1016\/j.cca.2024.119877_b0085","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1093\/jalm\/jfaa005","article-title":"Volumetric microsampling of capillary blood spot vs whole blood sampling for therapeutic drug monitoring of tacrolimus and cyclosporin a: accuracy and patient satisfaction","volume":"5","author":"Mbughuni","year":"2020","journal-title":"J. Appl. Lab. Med."},{"issue":"6","key":"10.1016\/j.cca.2024.119877_b0090","doi-asserted-by":"crossref","first-page":"495","DOI":"10.4155\/bio-2018-0312","article-title":"A volumetric absorptive microsampling LC-MS\/MS method for five immunosuppressants and their hematocrit effects","volume":"11","author":"Koster","year":"2019","journal-title":"Bioanalysis."},{"issue":"1242","key":"10.1016\/j.cca.2024.119877_b0095","article-title":"Liquid chromatography-tandem mass spectrometry for therapeutic drug monitoring of immunosuppressants and creatinine from a single dried blood spot using the Capitainer\u00ae qDBS device","volume":"15","author":"Deprez","year":"2023","journal-title":"Anal. Chim. Acta."},{"issue":"11","key":"10.1016\/j.cca.2024.119877_b0100","doi-asserted-by":"crossref","first-page":"4854","DOI":"10.1111\/bcp.15433","article-title":"Volumetric microsampling for simultaneous remote immunosuppressant and kidney function monitoring in outpatient kidney transplant recipients","volume":"88","author":"Zwart","year":"2022","journal-title":"Br. J. Clin. Pharmacol."},{"issue":"189","key":"10.1016\/j.cca.2024.119877_b0105","article-title":"Volumetric Absorptive Microsampling (VAMS) for assaying immunosuppressants from venous whole blood by LC-MS\/MS using a novel atmospheric pressure ionization probe (UniSpray\u2122)","volume":"10","author":"Paniagua-Gonz\u00e1lez","year":"2020","journal-title":"J. Pharm. Biomed. Anal."},{"issue":"7","key":"10.1016\/j.cca.2024.119877_b0110","doi-asserted-by":"crossref","first-page":"1962","DOI":"10.3390\/biomedicines11071962","article-title":"Biological fluid microsampling for therapeutic drug monitoring: a narrative review","volume":"11","author":"Cafaro","year":"2023","journal-title":"Biomedicines."},{"issue":"6","key":"10.1016\/j.cca.2024.119877_b0115","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.4155\/bio.10.58","article-title":"LC-MS\/MS for immunosuppressant therapeutic drug monitoring","volume":"2","author":"Sallustio","year":"2010","journal-title":"Bioanalysis."},{"issue":"7","key":"10.1016\/j.cca.2024.119877_b0120","doi-asserted-by":"crossref","first-page":"1327","DOI":"10.1007\/s00216-007-1320-1","article-title":"Current role of LC-MS in therapeutic drug monitoring","volume":"388","author":"Saint-Marcoux","year":"2007","journal-title":"Anal. Bioanal. Chem."}],"container-title":["Clinica Chimica Acta"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0009898124021302?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0009898124021302?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,8,13]],"date-time":"2024-08-13T12:52:05Z","timestamp":1723553525000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0009898124021302"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8]]},"references-count":24,"alternative-id":["S0009898124021302"],"URL":"https:\/\/doi.org\/10.1016\/j.cca.2024.119877","relation":{},"ISSN":["0009-8981"],"issn-type":[{"value":"0009-8981","type":"print"}],"subject":[],"published":{"date-parts":[[2024,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A novel approach to therapeutic drug monitoring of Ciclosporin in pediatric renal transplant recipients using volumetric absorptive microsampling (VAMS) \u2013 Teaching old dog new tricks","name":"articletitle","label":"Article Title"},{"value":"Clinica Chimica Acta","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.cca.2024.119877","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Author(s). Published by Elsevier B.V.","name":"copyright","label":"Copyright"}],"article-number":"119877"}}